Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Diabetes Metab ; 47(3): 101206, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33152550

RESUMO

Automated closed-loop (CL) insulin therapy has come of age. This major technological advance is expected to significantly improve the quality of care for adults, adolescents and children with type 1 diabetes. To improve access to this innovation for both patients and healthcare professionals (HCPs), and to promote adherence to its requirements in terms of safety, regulations, ethics and practice, the French Diabetes Society (SFD) brought together a French Working Group of experts to discuss the current practical consensus. The result is the present statement describing the indications for CL therapy with emphasis on the idea that treatment expectations must be clearly defined in advance. Specifications for expert care centres in charge of initiating the treatment were also proposed. Great importance was also attached to the crucial place of high-quality training for patients and healthcare professionals. Long-term follow-up should collect not only metabolic and clinical results, but also indicators related to psychosocial and human factors. Overall, this national consensus statement aims to promote the introduction of marketed CL devices into standard clinical practice.


Assuntos
Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Insulina , Adolescente , Adulto , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , França , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem
2.
Diabetes Metab ; 44(1): 61-72, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29174479

RESUMO

The use by diabetes patients of real-time continuous interstitial glucose monitoring (CGM) or the FreeStyle Libre® (FSL) flash glucose monitoring (FGM) system is becoming widespread and has changed diabetic practice. The working group bringing together a number of French experts has proposed the present practical consensus. Training of professionals and patient education are crucial for the success of CGM. Also, institutional recommendations must pay particular attention to the indications for and reimbursement of CGM devices in populations at risk of hypoglycaemia. The rules of good practice for CGM are the precursors of those that need to be enacted, given the oncoming emergence of artificial pancreas devices. It is necessary to have software combining user-friendliness, multiplatform usage and average glucose profile (AGP) presentation, while integrating glucose and insulin data as well as events. Expression of CGM data must strive for standardization that facilitates patient phenotyping and their follow-up, while integrating indicators of variability. The introduction of CGM involves a transformation of treatment support, rendering it longer and more complex as it also includes specific educational and technical dimensions. This complexity must be taken into account in discussions of organization of diabetes care.


Assuntos
Automonitorização da Glicemia , Educação de Pacientes como Assunto , Guias de Prática Clínica como Assunto , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/terapia , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/terapia , França , Humanos , Estudos Retrospectivos
3.
Diabetes Metab ; 41(6): 498-508, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26260529

RESUMO

AIM: The benefits of retrospective continuous glucose monitoring (retroCGM) recording have been widely explored in clinical studies, and many diabetes physicians routinely use this examination. However, the method of interpretation of CGM recordings has never been precisely described. METHOD: An expert French panel of physicians met for two days to discuss several aspects of retroCGM use and to produce a position statement. RESULTS: The guidelines cover the indications for retroCGM, the general organization and practical implementation of CGM recordings, a description of the different devices available and guidelines for the interpretation of retroCGM recordings. CONCLUSION: This consensus document should help clinicians in the proper use of retroCGM.


Assuntos
Automonitorização da Glicemia , Glicemia/análise , Diabetes Mellitus , Humanos
5.
Diabetes Metab ; 37 Suppl 4: S85-93, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22208717

RESUMO

This review discusses the most recent developments in insulin pump technology. The benefits of the insulin pump to patients with type 1 diabetes are recognized both for its metabolic effectiveness and its positive effects on quality of life. The current pumps are reliable, small and light, and are becoming more and more sophisticated. Nevertheless, there remain practical and psychological constraints for the patient. However, recent patch-pump advances should simplify the technical aspects of pump treatment and enhance patient comfort. Another advance combines the insulin pump with a glucose sensor. Such a combination is logical for optimizing pump use and, to that end, developing an automated or 'closed-loop'system that permits the delivery of subcutaneous insulin adjusted according to measured levels of subcutaneous glucose. Finally, implanted insulin pumps have proven their worth not only because of their simple use, but also for their contribution in the artificial pancreas project. Indeed, the prompt response with intraperitoneal administration of insulin makes it of interest for use in a closed-loop system.


Assuntos
Glicemia/metabolismo , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Bombas de Infusão Implantáveis/tendências , Sistemas de Infusão de Insulina/tendências , Análise de Variância , Glicemia/efeitos dos fármacos , Feminino , Humanos , Masculino , Qualidade de Vida
6.
Diabetes Metab ; 32(5 Pt 1): 427-32, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17110897

RESUMO

AIM: The purpose of this national multicenter prospective study by the French EVADIAC group was to investigate the possibility that continuous intraperitoneal insulin infusion using an implanted pump (CIpii) increases the risk of autoimmune disease in type 1 diabetic patients as it increased anti-insulin immunogenicity. METHODS: Prevalence of clinical (Hashimoto's disease, hyperthyroidism, gastric atrophic disease and vitiligo) and subclinical (presence of anti-thyroperoxidase antibodies, anti-intrinsic factor antibodies, abnormal TSH levels) autoimmune diseases was estimated by comparing two groups of patients already treated by either CIpii (n=154) or external pump (CSII) (n=121) for an average of 6 years. Incidence of autoimmune disease was determined by comparing the same measurements one year after inclusion. RESULTS: No significant difference was observed for the total prevalence of clinical and subclinical auto-immune thyroid and gastric di-seases (35.6% and 3.2% respectively in the CIpii group versus 40.4% and 2.6% in the CSII group). No significant difference for the incidence of clinical and subclinical auto-immune diseases was observed: 7.2% and 0% in CIpii and 7.3% and 1.7% in CSII. CONCLUSION: As previously shown AIA (anti-insulin antibodies) levels were higher in CIpii than in CSII (32.9% vs 20.2%, P<0.0001) but no correlation was observed with either clinical or subclinical autoimmune disease. This large-scale study eliminates the possibility that CIpii increases the risk of autoimmune disease.


Assuntos
Doenças Autoimunes/epidemiologia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/imunologia , Sistemas de Infusão de Insulina/efeitos adversos , Adulto , Autoanticorpos/sangue , Feminino , Doença de Hashimoto/epidemiologia , Humanos , Incidência , Masculino , Prevalência , Vitiligo/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...