Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Cardiol ; 364: 72-76, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35738415

RESUMO

BACKGROUND: Patients hospitalized for heart failure (HF) are at high risk for post-discharge events. Although transition from intravenous to oral diuretics for ≥24 h is commonly practiced to reduce post-discharge risk, evidence supporting this strategy is limited. We investigated the impact of this practice on 30 day post-discharge outcomes following HF hospitalization at our institution. METHODS: Retrospective chart review of patients hospitalized with a primary HF diagnosis, discharged on oral diuretic, and followed at our institution. Admission, in-hospital, and pre-discharge characteristics of patients discharged with ≥24-h observation were compared to those of patients observed for <24-h on oral diuretics. Differences between groups in composite 30 day all-cause mortality and rehospitalization, each component, and HF rehospitalization were assessed. RESULTS: Of 285 patients meeting entry criteria, 178 received oral diuretics ≥24 h prior to discharge and 107 were discharged <24 h after transitioning to oral diuretics. Baseline characteristics were similar between groups. Patients with ≥24 h observation on oral diuretics had longer in-hospital stays and greater weight and net volume loss than those observed <24 h. Patients receiving oral diuretics for <24 h were more likely to have had neurohormonal drugs and diuretic dose changed within 24-h of discharge. Oral diuretic treatment for ≥24 h failed to reduce any study endpoint. CONCLUSIONS: Transitioning patients to oral diuretics for ≥24 h prior to discharge following HF hospitalization failed to improve 30-day outcomes. These results question this strategy for all patients hospitalized for worsening HF.


Assuntos
Diuréticos , Insuficiência Cardíaca , Assistência ao Convalescente , Diuréticos/uso terapêutico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Hospitalização , Humanos , Alta do Paciente , Estudos Retrospectivos
2.
Talanta ; 94: 320-7, 2012 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-22608455

RESUMO

The two main goals of the analytical method described herein were to (1) use principal component analysis (PCA), hierarchical clustering (HCA) and K-nearest neighbors (KNN) to determine the feedstock source of blends of biodiesel and conventional diesel (feedstocks were two sources of soy, two strains of jatropha, and a local feedstock) and (2) use a partial least squares (PLS) model built specifically for each feedstock to determine the percent composition of the blend. The chemometric models were built using training sets composed of total ion current chromatograms from gas chromatography-quadrupole mass spectrometry (GC-qMS) using a polar column. The models were used to semi-automatically determine feedstock and blend percent composition of independent test set samples. The PLS predictions for jatropha blends had RMSEC=0.6, RMSECV=1.2, and RMSEP=1.4. The PLS predictions for soy blends had RMSEC=0.5, RMSECV=0.8, and RMSEP=1.2. The average relative error in predicted test set sample compositions was 5% for jatropha blends and 4% for soy blends.


Assuntos
Biocombustíveis , Glycine max/química , Jatropha/química , Cromatografia Gasosa-Espectrometria de Massas , Gasolina , Análise dos Mínimos Quadrados , Análise de Componente Principal
3.
Talanta ; 83(4): 1254-9, 2011 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-21215861

RESUMO

The percent composition of blends of biodiesel and conventional diesel from a variety of retail sources were modeled and predicted using partial least squares (PLS) analysis applied to gas chromatography-total-ion-current mass spectrometry (GC-TIC), gas chromatography-mass spectrometry (GC-MS), comprehensive two-dimensional gas chromatography-total-ion-current mass spectrometry (GCxGC-TIC) and comprehensive two-dimensional gas chromatography-mass spectrometry (GCxGC-MS) separations of the blends. In all four cases, the PLS predictions for a test set of chromatograms were plotted versus the actual blend percent composition. The GC-TIC plot produced a best-fit line with slope=0.773 and y-intercept=2.89, and the average percent error of prediction was 12.0%. The GC-MS plot produced a best-fit line with slope=0.864 and y-intercept=1.72, and the average percent error of prediction was improved to 6.89%. The GCxGC-TIC plot produced a best-fit line with slope=0.983 and y-intercept=0.680, and the average percent error was slightly improved to 6.16%. The GCxGC-MS plot produced a best-fit line with slope=0.980 and y-intercept=0.620, and the average percent error was 6.12%. The GCxGC models performed best presumably due to the multidimensional advantage of higher dimensional instrumentation providing more chemical selectivity. All the PLS models used 3 latent variables. The chemical components that differentiate the blend percent compositions are reported.


Assuntos
Biocombustíveis/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Gasolina/análise , Calibragem , Fracionamento Químico , Análise dos Mínimos Quadrados
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...