Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Clin Ophthalmol ; 18: 1515-1523, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38827770

RESUMO

Purpose: To report our experience of performing immediate sequential bilateral cataract surgery (ISBCS) in patients with visually significant cataracts and reduced preoperative corrected distance visual acuity (CDVA). Methods: Data of patients who underwent ISBCS for visually significant cataracts and had preoperative CDVA ≤20/32 (≤0.2 logMAR) in each eye were retrospectively reviewed. Refractive and visual outcomes were evaluated for the last available postoperative visit. Intraoperative and serious postoperative adverse events occurring within the first three months of surgery were reviewed. Results: A total of 1335 patients (2670 eyes) were included in the analysis, with a mean age of 71.9 ± 9.5 years. On the last visit, 50.2% and 89.1% of eyes achieved uncorrected distance visual acuity (UDVA) ≥20/20 (0.0 logMAR) and ≥20/32 (0.2 logMAR), respectively. Of all eyes, 83.8% were within ±0.50D, and 96.4% were within ±1.00 D of emmetropia. Ten patients had postoperative bilateral ametropia of more than 1.00D in each eye, but eight of them still achieved binocular UDVA ≥20/40. Intraoperative events occurred in 14 eyes of 13 patients (per-eye incidence: 0.524% or 1 in 191 eyes). A total of 86 postoperative adverse events occurred in 80 eyes of 53 patients (per-eye incidence 2.996% or 1 in 33 eyes), of which cystoid macular edema was the most common. Only three eyes had CDVA reduced by more than two Snellen lines compared to preoperative CDVA, two of which were not related to cataract surgery. There was no patient with bilateral CDVA loss. Conclusion: In our cohort of patients with visually significant cataracts, ISBCS resulted in good refractive predictability and a low incidence of serious adverse events.

2.
Clin Ophthalmol ; 18: 1157-1169, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38707771

RESUMO

Purpose: To compare the outcomes of the Tecnis Eyhance ICB00 IOL, designed to enhance intermediate vision, to a conventional Tecnis Monofocal ZCB00 IOL. Methods: This retrospective analysis compared two cohorts of patients undergoing lens replacement surgery with bilateral implantation of the Tecnis ICB00 or the Tecnis ZCB00 IOL (383 patients in each group). Monocular and binocular uncorrected distance (UDVA), intermediate (UIVA; 66cm), and near (UNVA; 40cm) visual acuities, refractive predictability, and patient-reported outcomes were compared. A sub-analysis of patients with the Eyhance IOL was performed to compare patients who achieved bilateral emmetropia to those with mini-monovision. One-month postoperative outcomes were analyzed. Results: Both groups had comparable UDVA outcomes. On average, both monocular and binocular UIVAs were approximately one Snellen line better in patients implanted with Eyhance IOL (monocular UIVA: ICB00 0.23 ± 0.18 logMAR, ZCB00 0.33 ± 0.19 logMAR; binocular UIVA: ICB00 0.18 ± 0.18 logMAR, ZCB00 0.26 ± 0.20 logMAR, p < 0.01). Likewise, the mean UNVA was also one Snellen line better with the ICB00 model (monocular UNVA: ICB00 0.51 ± 0.20 logMAR, ZCB00 0.61 ± 0.18 logMAR; binocular UNVA: ICB00 0.42 ± 0.19 logMAR, ZCB00 0.51 ± 0.22 logMAR, p < 0.01). There was no difference between the two groups in overall satisfaction or visual phenomena. A subgroup of patients who achieved mini-monovision with Eyhance IOL had, on average, one Snellen line better UIVA and UNVA compared to patients with bilateral emmetropia. Conclusion: Patients receiving the enhanced monofocal IOL had better intermediate and near vision compared to those receiving the conventional monofocal IOL, with similar levels of patient-reported photic phenomena in both groups.

3.
BMC Ophthalmol ; 24(1): 142, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38549055

RESUMO

BACKGROUND: Incorporation of the rapid advances in ophthalmologic surgical and diagnostic techniques inherent in the field poses a challenge to residency training programs. This study investigates exposure to new technologies during residency and perception of its impact on practice patterns. METHODS: Ophthalmology residents at various training levels and practicing ophthalmologists who had completed their training were invited to participate in a survey study assessing exposure to various technologies in residency and in practice. Data collection occurred from December 2022 to June 2023. Descriptive statistics were performed. RESULTS: The study received 132 unique responses, including 63 ophthalmology residents and 69 practicing ophthalmologists. 65.2% (n = 45) of practicing ophthalmologists and 47.6% (n = 30) of current residents reported discussion/training on newly developed products on the market (e.g. premium IOLS, MIGS), was "minimally discussed but not emphasized" or "not discussed at all" in residency. 55.1% (n = 38) of practicing ophthalmologists reported that exposure to new technologies during residency did influence types of technologies employed during practice. The majority resident physicians reported enjoying being trained on newer technology and feeling more prepared for future changes in the field (95.2%, n = 60) and felt that having industry partnerships in residency enhances education and training (90.5%, n = 57). CONCLUSIONS: Considering how to maximize exposure to newer technologies/devices during residency training is important, and may contribute to training more confident, adaptable surgeons, who are more likely to critically consider new technologies and adopt promising ones into their future clinical practice.


Assuntos
Internato e Residência , Oftalmologistas , Oftalmologia , Humanos , Educação de Pós-Graduação em Medicina , Oftalmologistas/educação , Competência Clínica , Oftalmologia/educação , Inquéritos e Questionários
4.
Clin Ophthalmol ; 18: 605-612, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38435374

RESUMO

Purpose: To examine the effect of preoperative angle kappa on patient-reported outcomes after multifocal lens placement during cataract surgery and determine if it is an effective measure for preoperative patients screening for multifocal lens placement. Setting: Private refractive surgery clinics. Design: Retrospective cohort study. Methods: All patients undergoing bilateral cataract or refractive lens exchange surgery with a target of emmetropia between 2013 and 2017 at Optical Express (Glasgow, UK) with multifocal lens placement for whom preoperative angle kappa measurement and a postoperative month 1 patient-reported outcomes measures were available were included. Results: A total of 1368 patients were identified. Median preoperative angle kappa was 0.41mm with an interquartile range of 0.30mm to 0.53mm. Preoperative angle kappa did not have a significant association with patient-reported satisfaction with vision (correlation coefficient 0.15, 95% confidence interval -0.081 to 0.39, P = 0.20) nor with patient-reported photic phenomena (P > 0.09 for all comparisons). A receiver-operator characteristic analysis did not yield a viable cutoff predictive of patient-reported satisfaction. Conclusion: Angle kappa was not predictive of patient-reported satisfaction in this study. This study did not find evidence that it should be used as a screening test for patients considering multifocal intraocular lens placement.

5.
J Cataract Refract Surg ; 50(6): 591-598, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350162

RESUMO

PURPOSE: To assess the effect of residual sphere on vision and satisfaction in pseudophakic patients. SETTING: Private clinics, United Kingdom. DESIGN: Retrospective case series. METHODS: A multivariate model evaluated the effect of 1-month residual sphere on outcomes of pseudophakic patients. Odds ratios (ORs) were calculated to assess the relative risk of not achieving ≥20/20 monocular uncorrected distance visual acuity (UDVA), ≥20/50 uncorrected near visual acuity (UNVA), and not being satisfied with vision. ORs were assessed for residual sphere -1.00 to +1.00 diopter (D) in quarter-diopter steps, using 0.00 D as a reference. RESULTS: The analysis included 38 828 multifocal and 11 571 monofocal intraocular lenses (IOLs). The residual myopic sphere ≤-0.25 D and hyperopic sphere ≥+0.50 D had a clinically meaningful effect on UDVA. Although monofocal IOLs had an improvement in UNVA with every additional 0.25 D of myopia, the change in ORs with increasing myopia was not significant for multifocal IOLs. The mean improvement in UNVA comparing eyes with 0.00 D and -1.00 D sphere was 0.26 logMAR for monofocal and 0.03 logMAR for multifocal IOLs. Low near-addition IOLs had a slightly higher gain in UNVA with increasing myopia, but the gain was not as substantial as with monofocal IOLs. The effect of ametropia on satisfaction was more pronounced for multifocal IOLs. For every 0.25 D of residual myopia, there was >25% increase in dissatisfied patients. CONCLUSIONS: Although myopia improved UNVA in eyes with monofocal IOL, multifocal IOLs did not benefit from residual myopia. Multifocal IOL patients desiring distance vision should be targeted closest to emmetropia, even if it means targeting slight hyperopia.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Lentes Intraoculares Multifocais , Satisfação do Paciente , Facoemulsificação , Pseudofacia , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Estudos Retrospectivos , Pseudofacia/fisiopatologia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Miopia/fisiopatologia , Hiperopia/fisiopatologia , Refração Ocular/fisiologia
6.
J Cataract Refract Surg ; 50(3): 306-311, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38381619

RESUMO

A 78-year-old woman with an ocular history of cataract surgery with a diffractive intraocular lens (IOL) in each eye has developed fluctuating vision, greater in the right eye than the left eye, after 4 years. She has a history of inactive central serous retinopathy and a vision potential of 20/25 + 2 in the right eye and 20/25 in the left eye. She has well-controlled diabetes, hypertension, and hypercholesterolemia. She has enjoyed her spectacle independence for some time and wishes to have her vision restored. On examination, her uncorrected distance visual acuity (UDVA) was 20/50 in the right eye and 20/25 in the left eye and her uncorrected near visual acuity (UNVA) was J3 in the right eye and J1 in the left eye. Intraocular pressures (IOPs) measured 22 mm Hg in the right eye and 18 mm Hg in the left eye. Pupils had limited reactivity with irregularity in the right eye but no obvious relative afferent pupillary defect. Motility and confrontation visual fields were unremarkable in both eyes. Retinal acuity meter was 20/20 in both eyes, and manifest refraction was plano -1.25 × 105 20/40, J3 in the right eye and +0.50 × 20/25, J1 in the left eye. Pertinent findings on slitlamp examination included temporal iris atrophy and transillumination defects greater in the right eye than the left eye, peripupillary pseudoexfoliative changes in both eyes, significant inferior subluxation of a diffractive 3-piece posterior chamber IOL in the capsular bag with lens-pitting peripherally and few central, moderate pseudophacodonesis, and an open posterior capsule in the right eye. In the left eye, she had mild inferior subluxation of a single-piece acrylic diffractive IOL in the capsular bag with moderate pseudophacodonesis and an open posterior capsule (Figure 1JOURNAL/jcrs/04.03/02158034-202403000-00019/figure1/v/2024-02-20T193212Z/r/image-tiff). All other anterior segment findings were unremarkable. On dilated posterior examination, she had a cup-to-disc ratio of 0.50 in the right eye and 0.65 in the left eye without edema hemorrhage or pallor. There were attenuated vessels in both eyes, posterior vitreous detachment in both eyes, and a few small drusen peripherally in both eyes. There was retinal pigment epithelium irregularity and dropout parafoveal in the right eye and subfoveal in the left eye (Figure 2). There was no evidence of macular edema, subretinal fluid, choroidal thickening, or neovascular membranes. The periphery was unremarkable in both eyes.JOURNAL/jcrs/04.03/02158034-202403000-00019/figure2/v/2024-02-20T193212Z/r/image-tiff What testing would you obtain preoperatively to help guide your decision-making? How would you counsel the patient regarding comorbid conditions and expectations?


Assuntos
Extração de Catarata , Lentes Intraoculares , Humanos , Feminino , Idoso , Implante de Lente Intraocular , Motivação , Acuidade Visual
7.
Ophthalmology ; 131(3): 383-392, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38149945

RESUMO

PURPOSE: To review the published literature evaluating the visual and refractive outcomes and rotational stability of eyes implanted with toric monofocal intraocular lenses (IOLs) for the correction of keratometric astigmatism during cataract surgery and to compare those outcomes with outcomes of eyes implanted with nontoric monofocal IOLs and other astigmatism management methods performed during cataract surgery. This assessment was restricted to the toric IOLs available in the United States. METHODS: A literature search of English-language publications in the PubMed database was last conducted in July 2022. The search identified 906 potentially relevant citations, and after review of the abstracts, 63 were selected for full-text review. Twenty-one studies ultimately were determined to be relevant to the assessment criteria and were selected for inclusion. The panel methodologist assigned each a level of evidence rating; 12 studies were rated level I and 9 studies were rated level II. RESULTS: Eyes implanted with toric IOLs showed excellent postoperative uncorrected distance visual acuity (UCDVA), reduction of postoperative refractive astigmatism, and good rotational stability. Uncorrected distance visual acuity was better and postoperative cylinder was lower with toric IOLs, regardless of manufacturer, when compared with nontoric monofocal IOLs. Correcting pre-existing astigmatism with toric IOLs was more effective and predictable than using corneal relaxing incisions (CRIs), especially in the presence of higher magnitudes of astigmatism. CONCLUSIONS: Toric monofocal IOLs are effective in neutralizing pre-existing corneal astigmatism at the time of cataract surgery and result in better UCDVA and significant reductions in postoperative refractive astigmatism compared with nontoric monofocal IOLs. Toric IOLs result in better astigmatic correction than CRIs, particularly at high magnitudes of astigmatism. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Astigmatismo , Catarata , Lentes Intraoculares , Oftalmologia , Facoemulsificação , Humanos , Astigmatismo/cirurgia , Implante de Lente Intraocular , Desenho de Prótese , Refração Ocular
8.
Clin Ophthalmol ; 17: 3579-3590, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38026600

RESUMO

Purpose: To compare refractive, visual, and patient-reported outcomes associated with a 1st generation wavefront-guided (WFG) treatment with those associated with a 3rd generation WFG treatment. Patients and Methods: This retrospective study included patients who underwent femtosecond laser-assisted in situ keratomileusis (LASIK) for myopia/myopic astigmatism. Two random stratified samples of patients who underwent either 1stgeneration (WaveScan, Johnson & Johnson Vision, Santa Ana, CA) or 3rd generation (iDesign 2.0, Johnson & Johnson Vision, Santa Ana, CA) treatment matched on preoperative refraction were compared (4290 eyes of 2145 patients in each group). One-month postoperative visual, refractive, and patient-reported outcomes were analyzed. Refractive and monocular visual acuity analyses were performed using one random eye of each patient. Results: The percentage of eyes achieving 20/20 or better uncorrected vision was 91.3% (1958/2145) in the 1st generation group and 95.9% (2056/2145) in the 3rd generation group (p<0.01). Binocularly, the percentage of patients with 20/20 or better UDVA was 97.0% (2080/2145) and 99.2% (2127/2145) in the 1st and 3rd generation groups, respectively (p<0.01). The mean postoperative MSE was -0.01 ± 0.33 D in the 1st generation group and +0.19 ± 0.33 D in the 3rd generation group (p<0.01). Postoperative refractive astigmatism had a mean value of -0.20 ± 0.26 D and -0.18 ± 0.24 D in the 1st and 3rd generation groups, respectively (p<0.01). The mean correction index of refractive astigmatism was 1.09 ± 0.53 in the 1st generation group and 1.02 ± 0.38 in the 3rd generation group, p<0.01. The overall percentage of patients satisfied with vision was 92.8% (1991/2145 patients) in the 1st generation group and 97.3% (2087/2145 patients) in the 3rd generation group (p<0.01). Conclusion: For the majority of postoperative variables, there were significant differences between 1st and 3rd generation treatments. The 3rd generation treatments had better visual acuity outcomes and higher patient satisfaction.

9.
Clin Ophthalmol ; 17: 3419-3427, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38026603

RESUMO

Purpose: To evaluate early clinical outcomes and adverse events (AEs) in cataract patients following implantation of a monofocal hydrophobic acrylic IOL with a new optimized non-constant aberration-correcting design (CT LUCIA 621P). Methods: This retrospective study included patients with visually significant cataracts who underwent implantation of the CT LUCIA 621P IOL. Refraction, corrected (CDVA) and uncorrected (UDVA) visual acuity of the last available visit were used in the analysis. Intraoperative and postoperative AEs of the cohort were reviewed. Results: A total of 191 eyes of 133 patients with the mean age of 70.2±11.2 years were included in this study. The mean follow-up time of the last available visit was 1.7±1.3 months. The mean postoperative monocular UDVA was 0.09±0.16 logMAR (≈20/25), and 74.9% (143/191) eyes achieved ≥20/25 UDVA. The percentage of eyes with manifest spherical equivalent (MSE) within ±0.50D and ±1.00D of emmetropia was 84.8% (162/191) and 98.4% (188/191), respectively. Linear regression of attempted vs achieved MSE showed a tight relationship, with the coefficient of determination close to 1 (R2=0.99), indicating a very predictable refractive correction. The reported AEs were those typically expected after cataract surgery. There were no AEs related to intraoperative manipulation with the IOL/injector or to postoperative stability of the IOL in the capsular bag. No eye lost ≥2 lines of CDVA. Conclusion: The implantation of CT LUCIA 621P resulted in good refractive predictability and visual outcomes. No IOL-related adverse events were reported.

10.
Am J Ophthalmol Case Rep ; 31: 101864, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37427094

RESUMO

Purpose: To describe the application of the light adjustable lens (LAL) using an intrascleral haptic fixation (ISHF) technique for the correction of aphakia and post-operative refractive error. Observation: The LAL was placed using a modified trocar-based ISHF technique for visual rehabilitation following removal of bilateral cataracts in a patient with ectopia lentis. She ultimately obtained an excellent refractive outcome after adjustment with micro-monovision. Conclusions and Importance: Secondary intraocular lens placement has a much higher risk of residual ametropia than traditional in-the-bag lens placement. The ISHF technique with the LAL presents a solution for eliminating postoperative refractive error in patients requiring scleral-fixated lenses.

11.
Ophthalmology ; 130(9): 924-936, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37086858

RESUMO

PURPOSE: To evaluate outcomes and the incidence of adverse events (AEs) in patients who underwent bilateral same-day refractive lens exchange (RLE). DESIGN: Retrospective case series. PARTICIPANTS: Patients of a private intraocular surgery provider in the United Kingdom who underwent RLE in both eyes on the same day with treatment dates between March 2018 and December 2021. METHODS: Clinical outcomes and AEs were collected for a continuous cohort of patients undergoing bilateral same-day RLE (in the absence of visually significant cataracts) or had mild cataracts (corrected visual acuity ≥ 20/40). One-month clinical outcomes were analyzed. MAIN OUTCOME MEASURES: Refractive outcomes and visual acuity, intraoperative and postoperative AEs, and secondary surgical interventions recorded within the first month after surgery. RESULTS: A total of 17 330 patients (34 660 eyes) were included in the analysis. Of these, 28 827 eyes received a multifocal intraocular lens (IOL), and 5833 eyes had a monofocal IOL. The percentage of eyes within ±0.50 diopters (D) of intended refraction was 85.5% and 86.2% for monofocal and multifocal IOL eyes, respectively. There was a total of 55 intraoperative AEs recorded in 55 eyes of 54 patients (per-eye incidence: 0.159%). Posterior capsule tear was the most common intraoperative event occurring in 37 eyes (0.107%). The number of AEs recorded within the first postoperative month was 267, occurring in 263 eyes of 177 patients (per-eye incidence: 0.759%). These included cystoid macular edema (CME) (172 eyes; 0.496%), significant corneal edema (28 eyes; 0.081%), persistent inflammation (27 eyes; 0.078%), significantly raised intraocular pressure (27 eyes; 0.078%), toxic anterior segment syndrome (8 eyes; 0.023%), wound leak (3 eyes; 0.009%), retinal detachment (1 eye; 0.003%), and retinal tear (1 eye; 0.003%). There were 56 secondary surgical interventions recorded within the first month of surgery, occurring in 54 eyes of 47 patients (per-eye incidence: 0.156%). The most common secondary intervention was the rotation of a misaligned toric IOL (24 eyes; 0.069%). CONCLUSIONS: Elective same-day bilateral RLE had a low incidence of serious AEs, and high refractive predictability. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Estudos Retrospectivos , Implante de Lente Intraocular , Acuidade Visual , Refração Ocular , Lentes Intraoculares/efeitos adversos , Facoemulsificação/efeitos adversos
12.
Clin Ophthalmol ; 17: 725-734, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36895950

RESUMO

Purpose: We evaluate the treatment effect of OC-01 (varenicline solution) nasal spray (VNS) in dry eye disease (DED) subjects from two randomized trials who self-reported autoimmune disease (AID). Patients and Methods: Post hoc subgroup analysis of subjects reporting a history of AID from the integrated OC-01 VNS 0.03 or 0.06 mg and vehicle control (VC) treatment groups of the ONSET-1 and ONSET-2 trials. Mean change in Schirmer test with anesthesia score (STS, mm) and Eye Dryness Score (EDS) from baseline to 28 days was compared between OC-01 VNS and VC groups. Consistency of treatment effect in subjects with and without AID was evaluated using treatment-subgroup interaction terms in ANCOVA models for mean changes from baseline STS and EDS, and in a logistic regression model for proportion achieving ≥10 mm STS improvement. Results: Of the 891 participants, 31 reported comorbid AID. In all models, the treatment-subgroup interaction terms were not significant (p>0.05), indicating consistency of therapeutic effect of OC-01 VNS in subjects with and without AID. In subjects with AID, the treatment difference for STS was 11.8 mm and -9.3 for EDS and difference for proportion of subjects with ≥10 mm STS improvement was 61.1%. The most common adverse event was sneeze (82-84%), graded as mild by 98% of subjects. Conclusion: OC-01 VNS demonstrated consistency in improving both tear production and patient-reported symptoms in subjects with AID, consistent with pivotal ONSET-1 and 2 trial results. Further investigation is warranted, and results may further support use of OC-01 VNS for DED in AID patients.

13.
Ophthalmology ; 130(1): 87-98, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36207168

RESUMO

OBJECTIVE: To evaluate current best practices for postoperative photorefractive keratectomy (PRK) pain control. METHODS: Literature searches in the PubMed database were last conducted in October 2021 and were restricted to publications in English. This search identified 219 citations, of which 84 were reviewed in full text for their relevance to the scope of this assessment. Fifty-one articles met the criteria for inclusion; 16 studies were rated level I, 33 studies were rated level II, and 2 studies were rated level III. RESULTS: Systemic opioid and nonsteroidal anti-inflammatory drugs (NSAIDs); topical NSAIDs; postoperative cold patches; bandage soft contact lenses (BCLs), notably senofilcon A contact lenses; and topical anesthetics were demonstrated to offer significantly better pain control than comparison treatments. Some other commonly reported pain mitigation interventions such as systemic gabapentinoids, chilled intraoperative balanced salt solution (BSS) irrigation, cycloplegia, and specific surface ablation technique strategies offered limited improvement in pain control over control treatments. CONCLUSIONS: Systemic NSAIDs and opioid medications, topical NSAIDs, cold patches, BCLs, and topical anesthetics have been shown to provide improved pain control over alternative strategies and allow PRK-associated pain to be more tolerable for patients.


Assuntos
Lentes de Contato Hidrofílicas , Oftalmologia , Ceratectomia Fotorrefrativa , Humanos , Anestésicos Locais , Analgésicos Opioides/uso terapêutico , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/prevenção & controle , Anti-Inflamatórios não Esteroides/uso terapêutico , Lasers de Excimer/uso terapêutico
14.
Ophthalmology ; 129(12): e159-e160, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36182589
15.
Clin Ophthalmol ; 16: 2531-2543, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35974904

RESUMO

Purpose: To evaluate clinical and subjective outcomes of a segmented bifocal IOL with a 2.0 D near addition. Patients and Methods: Retrospective analyses of patients who had undergone refractive lens exchange with bilateral implantation of the SBL-2 IOL (Lenstec, Inc., Christ Church, Barbados) were performed. The number of patients included in the study was 389 (778 eyes). Refractive, visual and patient-reported outcomes were presented for the last available visit (mean follow-up 2.05 ± 1.33 months). Results: The percentage of eyes within ±0.50D and ±1.00D of emmetropia was 82.5% (642/778) and 97.8% (761/778), respectively. The mean uncorrected intermediate visual acuity (66 cm) of the last available visit was 0.08 ± 0.15 logMAR monocularly and 0.04 ± 0.14 logMAR binocularly. The mean monocular and binocular uncorrected near visual acuity (40 cm) were 0.30 ± 0.15 logMAR and 0.24 ± 0.14 logMAR, respectively. Of all patients, 97.2% (378/389) claimed never to use any correction for distance vision, while 93.1% (362/389) of patients did not require any correction for near vision. The mean scores for visual phenomena (on the scale from 1 - no difficulty to 7 - severe difficulty) were 1.8 ± 1.3, 1.7 ± 1.2, 1.7 ± 1.2 and 1.6 ± 1.2 for glare, halo, starburst, and ghosting/double vision, respectively. Conclusion: Despite the lower near addition of SBL-2 segmented bifocal IOL, patients achieved reasonable rates of spectacle independence and a low incidence of visual phenomena.

17.
Ophthalmology ; 129(8): 946-954, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35570159

RESUMO

PURPOSE: To evaluate refractive outcomes, safety, and cost-effectiveness of femtosecond laser-assisted cataract surgery (FLACS) compared with phacoemulsification cataract surgery (PCS). METHODS: A PubMed search of FLACS was conducted in August 2020. A total of 727 abstracts were reviewed and 33 were selected for full-text review. Twelve articles met inclusion criteria and were included in this assessment. The panel methodologist assigned a level of evidence rating of I to all 12 studies. RESULTS: No significant differences were found in mean uncorrected distance visual acuity, best-corrected distance visual acuity, or the percentage of eyes within ± 0.5 and ± 1 diopter of intended refractive target between FLACS and PCS. Intraoperative and postoperative complication rates were similar between the 2 groups, and most studies showed no difference in endothelial cell loss between FLACS and PCS at various time points between 1 and 6 months. In large randomized controlled studies in the United Kingdom and France, FLACS was less cost-effective than PCS. CONCLUSIONS: Both FLACS and PCS have similar excellent safety and refractive outcomes. At this time, one technique is not superior to the other, but economic analyses performed in some populations have shown that FLACS is less cost-effective.


Assuntos
Extração de Catarata , Catarata , Terapia a Laser , Oftalmologia , Facoemulsificação , Extração de Catarata/métodos , Humanos , Terapia a Laser/métodos , Lasers , Facoemulsificação/métodos
18.
J Med Internet Res ; 24(7): e27310, 2022 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-35537041

RESUMO

BACKGROUND: Studies suggest diurnal patterns of occurrence of some eye conditions. Leveraging new information sources such as web-based search data to learn more about such patterns could improve the understanding of patients' eye-related conditions and well-being, better inform timing of clinical and remote eye care, and improve precision when targeting web-based public health campaigns toward underserved populations. OBJECTIVE: To investigate our hypothesis that the public is likely to consistently search about different ophthalmologic conditions at different hours of the day or days of week, we conducted an observational study using search data for terms related to ophthalmologic conditions such as conjunctivitis. We assessed whether search volumes reflected diurnal or day-of-week patterns and if those patterns were distinct from each other. METHODS: We designed a study to analyze and compare hourly search data for eye-related and control search terms, using time series regression models with trend and periodicity terms to remove outliers and then estimate diurnal effects. We planned a Google Trends setting, extracting data from 10 US states for the entire year of 2018. The exposure was internet search, and the participants were populations who searched through Google's search engine using our chosen study terms. Our main outcome measures included cyclical hourly and day-of-week web-based search patterns. For statistical analyses, we considered P<.001 to be statistically significant. RESULTS: Distinct diurnal (P<.001 for all search terms) and day-of-week search patterns for eye-related terms were observed but with differing peak time periods and cyclic strengths. Some diurnal patterns represented those reported from prior clinical studies. Of the eye-related terms, "pink eye" showed the largest diurnal amplitude-to-mean ratios. Stronger signal was restricted to and peaked in mornings, and amplitude was higher on weekdays. By contrast, "dry eyes" had a higher amplitude diurnal pattern on weekends, with stronger signal occurring over a broader evening-to-morning period and peaking in early morning. CONCLUSIONS: The frequency of web-based searches for various eye conditions can show cyclic patterns according to time of the day or week. Further studies to understand the reasons for these variations may help supplement the current clinical understanding of ophthalmologic symptom presentation and improve the timeliness of patient messaging and care interventions.


Assuntos
Conjuntivite , Oftalmopatias , Oftalmopatias/diagnóstico , Humanos , Infodemiologia , Internet , Ferramenta de Busca
19.
J Ophthalmic Inflamm Infect ; 12(1): 5, 2022 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-35119525

RESUMO

PURPOSE: To describe a case series of combined Boston Type 1 Keratoprosthesis with pars plana vitrectomy, silicone oil placement, and fluocinolone acetonide intravitreal 0.59 mg implant (RETISERT®), and report its safety and efficacy in preventing phthisis bulbi in patients with uveitis-associated hypotony and concurrent corneal edema. FINDINGS: A retrospective review of patients with chronic uveitis, corneal decompensation and concurrent hypotony who underwent the combined approach described here between 2015 and 2020 was conducted. Three patients were treated using the combined approach. Post-operative recovery was unremarkable in all cases and the patients' corneal condition remained stable on follow up. No patient developed phthisis, retroprosthetic membrane, or infectious endophthalmitis. Average intraocular pressure one year after intervention was 2.7 to 6.4 mmHg higher compared to a year prior. CONCLUSIONS: The approach described is potentially safe and effective in preventing phthisis and membrane formation in uveitis-associated hypotony and keratopathy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...