Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(15)2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39125473

RESUMO

BACKGROUND: Suspicious tumors of the lung require specific staging, intraoperative detection, and histological confirmation. We performed an intrathoracic, intraoperative contrast-enhanced ultrasound (Io-CEUS) for characterization of lung cancer. METHODS: Retrospective analysis of prospectively collected data on the application of Io-CEUS in thoracic surgery for patients with operable lung cancer. Analysis of the preoperative chest CT scan and FDG-PET/CT findings regarding criteria of malignancy. Immediately before lung resection, the intrathoracic Io-CEUS was performed with a contrast-enabled T-probe (6-9 MHz-L3-9i-D) on a high-performance ultrasound machine (Loqic E9, GE). In addition to intraoperative B-mode, color-coded Doppler sonography (CCDS), or power Doppler (macrovascularization) of the lung tumor, contrast enhancement (Io-CEUS) was used after venous application of 2.4-5 mL sulfur hexafluoride (SonoVue, Bracco, Italy) for dynamic recording of microvascularization. The primary endpoint was the characterization of operable lung cancer with Io-CEUS. Secondly, the results of Io-CEUS were compared with the preoperative staging. RESULTS: The study included 18 patients with operable lung cancer, who received Io-CEUS during minimally invasive thoracic surgery immediately prior to lung resection. In the chest CT scan, the mean size of the lung tumors was 2.54 cm (extension of 0.7-4.5 cm). The mean SUV in the FDG-PET/CT was 7.6 (1.2-16.9). All lung cancers were detected using B-mode and power Doppler confirmed macrovascularization (100%) of the tumors. In addition, Io-CEUS showed an early wash-in with marginal and mostly simultaneous central contrast enhancement. CONCLUSIONS: The intrathoracic application of Io-CEUS demonstrated a peripheral and simultaneous central contrast enhancement in the early phase, which seems to be characteristic of lung cancer. In comparison to preoperative imaging, Io-CEUS was on par with the detection of malignancy and offers an additional tool for the intraoperative assessment of lung cancer before resection.

2.
Cancers (Basel) ; 15(15)2023 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-37568670

RESUMO

BACKGROUND: The intraoperative detection of solitary pulmonary nodules (SPNs) continues to be a major challenge, especially in minimally invasive video-assisted thoracic surgery (VATS). The location, size, and intraoperative frozen section result of SPNs are decisive regarding the extent of lung resection. This feasibility study investigates the technical applicability of intraoperative contrast-enhanced ultrasonography (Io-CEUS) in minimally invasive thoracic surgery. METHODS: In this prospective, monocentric clinical feasibility study, n = 30 patients who underwent Io-CEUS during elective minimally invasive lung resection for SPNs between October 2021 and February 2023. The primary endpoint was the technical feasibility of Io-CEUS during VATS. Secondary endpoints were defined as the detection and characterization of SPNs. RESULTS: In all patients (female, n = 13; mean age, 63 ± 8.6 years) Io-CEUS could be performed without problems during VATS. All SPNs were detected by Io-CEUS (100%). SPNs had a mean size of 2.2 cm (0.5-4.5 cm) and a mean distance to the lung surface of 2.0 cm (0-6.4 cm). B-mode, colour-coded Doppler sonography, and contrast-enhanced ultrasound were used to characterize all tumours intraoperatively. Significant differences were found, especially in vascularization as well as in contrast agent behaviour, depending on the tumour entity. After successful lung resection, a pathologic examination confirmed the presence of lung carcinomas (n = 17), lung metastases (n = 10), and benign lung tumours (n = 3). CONCLUSIONS: The technical feasibility of Io-CEUS was confirmed in VATS before resection regarding the detection of suspicious SPNs. In particular, the use of Doppler sonography and contrast agent kinetics revealed intraoperative specific aspects depending on the tumour entity. Further studies on Io-CEUS and the application of an endoscopic probe for VATS will follow.

3.
Clin Hemorheol Microcirc ; 85(1): 87-92, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37599526

RESUMO

AIM: To apply intraoperative ultrasound (IO-US) for the first time using a laparascopic probe to detect malignancy-susceptible solitary pulmonary nodules (SPN) and assess macrovascularization using color-coded doppler sonography or power doppler. Description of technical feasibility. METHODS: Technical description on intrathoracic endoscopic ultrasound. A positive ethics vote from the local ethics committee and written patient consent were available. Intraoperative ultrasound was performed using a laparascopic probe (Lap 13-4cs, Mindray) on the T9 ultrasound machine (Mindray, China). B-scan was used to detect the SPN. Color-coded doppler sonography (CCS) and power doppler were used to assess macrovascularization. Primary end point was the description of the technical performance of the Io-US. Secondary endpoints were the functions of Io-US in characterizing SPN. RESULTS: Io-US was successfully applied using (n = 2) cases in video-assisted thoracic surgery. All SPN were successfully detected intraoperatively with the intrathoracically placed laparascopy probe using B-mode and examined using CCS or power Doppler (100%). Resection was sonography-guided with marking of the tumor area in all cases without complications. Histological workup revealed malignancy in both cases. CONCLUSION: Intrathoracic application of laparascopically guided Io-US was technically feasible. In addition to B-mode detection, Io-US using power doppler and color-coded doppler sonography provided initial evidence for characterization of SPN based on macrovascularization.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA