1.
Otol Neurotol ; 33(5): 745-50, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22664904

RESUMO

OBJECTIVES: This study aimed to evaluate the possibility of predicting radiologically the scalar localization of a 31.5-mm-long, free-fitting electrode carrier for cochlear implantation, using conventional planar computed tomography. STUDY DESIGN: A cross-sectional human temporal bone study was conducted. SETTING: Twenty human temporal bones were acquired postmortem and implanted with 31.5-mm-long electrode carriers. Ten of these were implanted into the scala tympani using the round window approach, whereas the other 10 electrodes were inserted into the scala vestibuli by cochleostomy. Computed tomography was then performed, and 2 experienced blinded radiologists evaluated the intracochlear position of the array. MAIN OUTCOME MEASURE: The estimated position of the electrode carrier was described using a 5-point scale. After sectioning and histologic investigation, the results of the radiologic and histologic investigations were compared. RESULTS: In 17 of 20 cases, it was possible to estimate the correct position of the electrode carrier within the basal turn of the cochlea by means of computed tomography. As the insertion angles widened beyond 360 degrees, it became increasing difficult for the radiologists to correctly determine the position of the electrode carrier. CONCLUSION: The comparison of our temporal bone experiment results with the computed tomography results revealed the difficulty of assessing the correct position of intracochlear electrodes. Scalar localization of deeply inserted electrode carriers cannot be precisely determined by means of computed tomography.


Assuntos
Implante Coclear/métodos , Rampa do Tímpano/cirurgia , Rampa do Vestíbulo/cirurgia , Osso Temporal/cirurgia , Implantes Cocleares , Estudos Transversais , Humanos , Radiografia , Rampa do Tímpano/diagnóstico por imagem , Rampa do Vestíbulo/diagnóstico por imagem , Osso Temporal/diagnóstico por imagem
2.
J Thorac Imaging ; 27(6): 376-81, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22487993

RESUMO

PURPOSE: To investigate pulmonary arterial (PA) enhancement, image noise, and artifacts related to breathing and heart motion in patients with suspected pulmonary embolism. MATERIALS AND METHODS: Seventy-six consecutive patients underwent computed tomographic pulmonary angiography (CTPA) in dual-source high-pitch mode (pitch 3.0, 100 kV, 180 mAs, 50 mL contrast material) without breathing commands. PA enhancement, image noise, signal to noise ratio, overall image quality, incidence of total or partial interruption of the contrast column in the PAs, and heart motion-related and breathing-related artifacts of the diaphragm and pulmonary structures were recorded. RESULTS: Mean central and peripheral PA attenuation was 404 ± 104 and 453 ± 119 HU; mean image noise was 11 ± 2 HU; mean examination time was 0.67 ± 0.09 s; and mean dose-length product was 142 ± 31 mGy cm. There were no motion artifacts of the diaphragm or pulmonary vessels related to breathing or heart motion. There was no case of partial or total interruption of the contrast column in the PA tree. No examination was rated nondiagnostic. CONCLUSIONS: High-pitch dual-source CTPA in freely breathing patients effectively produces images that are free of artifacts related to breathing and cardiac motion. Hence, Valsalva-related artifacts can be eliminated using this technique.


Assuntos
Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Respiração , Razão Sinal-Ruído , Adulto Jovem
3.
Eur Radiol ; 22(1): 129-37, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21915607

RESUMO

OBJECTIVE: To investigate the feasibility, image quality and radiation dose for high-pitch dual-source CT angiography (CTA) of the whole aorta without ECG synchronisation. METHODS: Each group of 40 patients underwent CTA either on a 16-slice (group 1) or dual-source CT device with conventional single-source (group 2) or high-pitch mode with a pitch of 3.0 (group 3). The presence of motion or stair-step artefacts of the thoracic aorta was independently assessed by two readers. RESULTS: Subjective and objective scoring of motion and artefacts were significantly reduced in the high-pitch examination protocol (p < 0.05). The imaging length was not significantly different, but the imaging time was significantly (p < 0.001) shorter in the high-pitch group (12.2 vs. 7.4 vs. 1.7 s for groups 1, 2 and 3). The ascending aorta and the coronary ostia were reliably evaluable in all patients of group 3 without motion artefacts as well. CONCLUSION: High-pitch dual-source CT angiography of the whole aorta is feasible in unselected patients. As a significant advantage over regular pitch protocols, motion-free imaging of the aorta is possible without ECG synchronisation. Thus, this CT mode bears potential to become a standard CT protocol before trans-catheter aortic valve implantation (TAVI).


Assuntos
Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Artefatos , Angiografia Coronária , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/fisiopatologia , Doenças da Aorta/fisiopatologia , Angiografia Coronária/métodos , Estudos de Viabilidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
4.
Eur J Radiol ; 81(10): 2887-91, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22019597

RESUMO

PURPOSE: To compare test bolus and bolus tracking for the determination of scan delay of high-pitch dual-source CT pulmonary angiography in patients with suspected pulmonary embolism using 50 ml of contrast material. MATERIALS AND METHODS: Data of 80 consecutive patients referred for CT pulmonary angiography were evaluated. All scans were performed on a 128-channel dual-source CT scanner with a high-pitch protocol (pitch 3.0, 100 kV, 180 mAs). Contrast enhancement was achieved by injecting 50 ml of iomeprol followed by a saline chaser of 50 ml injected at a rate of 4 ml/s. The scan delay was determined using either the test bolus (n=40) or bolus tracking (n=40) technique. Test bolus required another 15 ml CM to determine time to peak enhancement of the contrast bolus within the pulmonary trunk. Attenuation profiles in the pulmonary trunk and on segmental level as well as in the ascending aorta were measured to evaluate the timing techniques. Additionally, overall image quality was evaluated. RESULTS: In all patients an adequate and homogeneous contrast enhancement of more than 250 HU was achieved in the pulmonary arteries. No statistically significant difference between test bolus and bolus tracking was found regarding attenuation of the pulmonary arteries or overall image quality. However, using bolus tracking 15 ml CM less was injected. CONCLUSION: A homogeneous opacification of the pulmonary arteries and sufficient image quality can be achieved with both the bolus tracking and test bolus techniques with significant lower contrast doses compared to conventional contrast material injection protocols.


Assuntos
Angiografia/métodos , Meios de Contraste/administração & dosagem , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Eur J Radiol ; 79(2): e128-32, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21640536

RESUMO

PURPOSE: To determine the difference in radiation dose between non-enhanced (NECT) and contrast-enhanced (CECT) chest CT examinations contributed by contrast material with different scanner generations with automatic exposure control (AEC). METHODS & MATERIALS: Each 42 adult patients received a NECT and CECT of the chest in one session on a 16-, 64- or 128-slice CT scanner with the same scan protocol settings. However, AEC technology (Care Dose 4D, Siemens) underwent upgrades in each of the three scanner generations. DLP, CTDIvol and image noise were compared. RESULTS: Although absolute differences in image noise were very small and ranged between 10 and 13 HU for NECT and CECT in median, the differences in image noise and dose (DLP: 16-slice:+2.8%; 64-slice:+3.9%; 128-slice:+5.6%) between NECT and CECT were statistically significant in all groups. Image noise and dose parameters were significantly lower in the most recent 128-slice CT generation for both NECT and CECT (DLP: 16-slice:+35.5-39.2%; 64-slice:+6.8-8.5%). CONCLUSION: The presence of contrast material lead to an increase in dose for chest examinations in three CT generations with AEC. Although image noise values were significantly higher for CECT, the absolute differences were in a range of 3 HU. This can be regarded as negligible, thus indicating that AEC is able to fulfill its purpose of maintaining image quality. However, technological developments lead to a significant reduction of dose and image noise with the latest CT generation.


Assuntos
Meios de Contraste/administração & dosagem , Iopamidol/análogos & derivados , Doses de Radiação , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Iopamidol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Torácica/instrumentação , Estudos Retrospectivos , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X/instrumentação
6.
Eur Radiol ; 21(10): 2139-47, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21614614

RESUMO

OBJECTIVE: To compare dose and image quality of 64-slice, first and second generation dual-energy CT (DECT) for CT pulmonary angiography (CTPA). METHODS: Totally 120 patients, 30 in each group, underwent CTPA on a first generation (group 1: single-energy, 120 kV/145 mAs; group 2: DE, 140/80 kV, 70/350 mAs) or second generation dual-source DECT device (group 3: DE, 100/Sn140 kV, 120/102 mAs; group 4: DE, 80/Sn140 kV, 202/86 mAs). CTDIvol, DLP, background noise (BN), thorax diameter and attenuation in the pulmonary trunk were compared. RESULTS: Thorax diameter and attenuation in the pulmonary trunk did not differ significantly (p > 0.4 and >0.19) between the groups. Mean CTDIvol and DLP were significantly lower (p < 0.003) in group 4 (6.2 ± 1.6 mGy/170 ± 41 mGycm) compared to group 1 (8.5 ± 2.6 mGy/235 ± 117 mGycm), group 2 (9.2 ± 3.3 mGy/224 ± 122 mGycm) and group 3 (8.7 ± 2.8 mGy/246 ± 86 mGycm). BN was significantly lower (p < 0.0001) in group 4 (12 ± 3 HU) and group 1 (13 ± 6 HU) compared to group 3 and 2 (16 ± 6 HU and 23 ± 9). CONCLUSION: The use of second generation DECT in 80/Sn140 kV configuration allows for significant dose reduction with image quality similar to 120 kV CTPA.


Assuntos
Angiografia/métodos , Pulmão/patologia , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/farmacologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Embolia Pulmonar/patologia , Doses de Radiação , Radiografia Torácica/métodos
7.
Eur Radiol ; 21(9): 1914-21, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21533631

RESUMO

OBJECTIVE: To investigate the role of perfusion defect (PD) size on dual energy CT pulmonary blood volume assessment as predictor of right heart strain and patient outcome and its correlation with d-dimer levels in acute pulmonary embolism (PE). METHODS: 53 patients with acute PE who underwent DECT pulmonary angiography were retrospectively analyzed. Pulmonary PD size caused by PE was measured on DE iodine maps and quantified absolutely (VolPD) and relatively to the total lung volume (RelPD). Signs of right heart strain (RHS) on CT were determined. Information on d-dimer levels and readmission for recurrent onset of PE and death was collected. RESULTS: D-dimer level was mildly (r = 0.43-0.47) correlated with PD size. Patients with RHS had significantly higher VolPD (215 vs. 73 ml) and RelPD (9.9 vs. 2.9%) than patients without RHS (p < 0.003). There were 2 deaths and 1 readmission due of PE in 18 patients with >5% RelPD, while no such events were found for patients with <5% RelPD. CONCLUSION: Pulmonary blood volume on DECT in acute PE correlates with RHS and appears to be a predictor of patient outcome in this pilot study.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Pulmão/irrigação sanguínea , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/mortalidade , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Função do Átrio Esquerdo/fisiologia , Biomarcadores/sangue , Estudos de Casos e Controles , Estudos de Coortes , Intervalos de Confiança , Feminino , Testes de Função Cardíaca , Humanos , Estimativa de Kaplan-Meier , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Circulação Pulmonar/fisiologia , Embolia Pulmonar/sangue , Estudos Retrospectivos , Índice de Gravidade de Doença , Análise de Sobrevida , Função Ventricular Direita/fisiologia
8.
Eur J Radiol ; 80(3): e483-7, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20970940

RESUMO

PURPOSE: Lung perfusion analysis at dual energy CT (DECT) is sensitive to beam hardening artifacts from dense contrast material (CM). We compared two scan and four CM injection protocols in terms of severity of artifacts and attenuation levels in the thoracic vessels. METHODS AND MATERIALS: Data of 120 patients who had undergone dual source dual energy CT pulmonary angiography for suspected acute pulmonary embolism were evaluated. Group 1 (n=30) was scanned in craniocaudal direction using 64×0.6 mm collimation; groups 2-4 (n=30 each) were scanned in caudocranial direction using 14×1.2 mm collimation. In groups 1-3 biphasic injection protocols with different amounts of CM and NaCl were investigated. In group 4 a split-bolus protocol with an initial CM bolus of 50 ml followed by 30 ml of a 70%:30% NaCl/CM mixture and a 50 ml NaCl chaser bolus was used. CT density values in the subclavian vein (SV), superior vena cava (SVC), pulmonary artery tree (PA), and the descending aorta (DA) were measured. Artifacts arising from the SV and SVC on DE pulmonary iodine distribution map were rated on a scale from 1 to 5 (1=fully diagnostic; 5=non-diagnostic) by two blinded readers. RESULTS: In protocol 4 mean attenuation in the SV (645±158 HU) and SVC (389±114 HU) were significantly lower compared to groups 1-3 (p<0.002). Artifacts in group 4 (1.1±0.4 and 1.5±0.7 for the SV and SVC, respectively) were rated significantly less severe compared to group 1 (3.2±1.0 and 3.0±1.1), 2 (2.6±1.1 and 2.3±1.0) and 3 (1.9±0.9 and 1.9±0.7) (p<0.01 for all), whereas no significant difference was found between groups 1 and 2 for the subclavian vein (p=0.07). Attenuation in the PA was also significantly lower in group 4 (282±116 HU) compared to group 1 (397±137 HU), group 2 (376±115 HU) and group 3 (311±104 HU), but still on a diagnostic level. CONCLUSION: Split-bolus injection provides sufficient attenuation for pulmonary DECT angiography while beam hardening artifacts arising from high density contrast material in the thoracic vessels can be reduced significantly.


Assuntos
Angiografia/métodos , Iopamidol/administração & dosagem , Imagem de Perfusão/métodos , Embolia Pulmonar/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Artefatos , Meios de Contraste/administração & dosagem , Feminino , Humanos , Injeções Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Artérias Torácicas/diagnóstico por imagem
9.
Eur Radiol ; 21(1): 107-12, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20644936

RESUMO

OBJECTIVE: Computed tomography (CT) of the paranasal sinus is the standard diagnostic tool for a wide range of indications in mostly younger patients. This study aims to assess the image quality of CT of the sinus by using a high-pitch dual-source technique with special regard to the radiation dose. METHODS: Examinations were performed on a second-generation dual-source CT with a pitch factor of 3.0 (dual-source mode). Images were compared with those with a pitch factor of 0.9 on the same system (single-source mode) and with those of 16-slice CT. Image quality was evaluated by four blinded readers using a 5-point scale (1=poor, 5=excellent). Comparison of the dose length product (DLP) was used to estimate radiation exposure. RESULTS: Seventy-three consecutive patients underwent imaging with the proposed CT protocols. The viewers rated the image quality of the dual-source image sets as nearly as good (3.62) as the single-source images on the same device (4.18) and those on 16-slice CT (3.7). DLP was cut to half of the dose [51 mGycm vs. 97.8 mGycm vs. 116.9 mGycm (p<0.01)]. CONCLUSIONS: Using the proposed dual-source mode when examining the paranasal sinus, diagnostic image quality can be achieved while drastically lowering the patient's radiation exposure.


Assuntos
Seios Paranasais/diagnóstico por imagem , Crânio/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Humanos , Pessoa de Meia-Idade , Monitoramento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...