Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
J Osteoporos ; 2023: 7861495, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38179189

RESUMO

Purpose: This pilot study aimed to explore the feasibility of scanning the human distal radius bone marrow in vivo to detect osteoporosis-related changes using magnetic resonance and evaluate whether the radius may serve as an accessible probing site for osteoporosis. This may lead in the future to the use of affordable means such as low-field MRI scanners for the monitoring of disease progression. Methods: A clinical trial was performed using a 3T MR scanner, including 26 women assigned into three study groups: healthy-premenopausal (n = 7; mean age 48.6 ± 3.5 years), healthy-postmenopausal (n = 10; mean age 54.5 ± 5.6 years), and osteoporotic-postmenopausal (n = 9; mean age 61.3 ± 5.6 years). Marrow fat composition was evaluated using T2 maps, a two-compartment model of T1, and a Dixon pulse sequence. Results: The osteoporotic group exhibited higher fat content than the other two groups and lower T2 values than the healthy-premenopausal group. Conclusions: Osteoporosis-related changes in the composition of the distal radius bone marrow may be detected in vivo using MRI protocols. The scanning protocols chosen here can later be repeated using low-field MRI scanners, thus offering the potential for early detection and treatment monitoring, using an accessible, affordable means that may be applied in small clinics. This trial is registered with MOH_2018-05-23_002247, NCT03742362.

2.
Toxicol Pathol ; 45(4): 444-471, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28641506

RESUMO

Available imaging systems for use in preclinical toxicology studies increasingly show utility as important tools in the toxicologic pathologist's armamentarium, permit longitudinal evaluation of functional and morphological changes in tissues, and provide important information such as organ and lesion volume not obtained by conventional toxicology study parameters. Representative examples of practical imaging applications in toxicology research and preclinical studies are presented for ultrasound, positron emission tomography/single-photon emission computed tomography, optical, magnetic resonance imaging, and matrix-assisted laser desorption ionization-imaging mass spectrometry imaging. Some of the challenges for making imaging systems good laboratory practice-compliant for regulatory submission are presented. Use of imaging data on a case-by-case basis as part of safety evaluation in regulatory submissions is encouraged.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Tomografia Computadorizada de Emissão de Fóton Único , Toxicologia/métodos , Ultrassonografia , Animais , Modelos Animais de Doenças , Processamento de Imagem Assistida por Computador , Camundongos , Ratos
3.
Toxicol Pathol ; 45(4): 472-480, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28443458

RESUMO

Infusion site reactions are common following subcutaneous infusion of drugs. Such reactions can lead to discontinuation of the treatment. Therefore, assessment of such reactions is essential during preclinical safety studies, and magnetic resonance imaging (MRI) can assist in evaluation. Here, in vivo and ex vivo MRI evaluations were used in addition to classical histopathology to assess the infusion site reaction to ND0701, a novel formulation of apomorphine base developed for the treatment of Parkinson's disease, in comparison to the commercial apomorphine hydrochloride (HCl) formulation. Both formulations, each at two concentrations, were continuously administered subcutaneously for 20 hr to each of 3 male and 3 female domestic pigs. Based on MRI evaluations, there was a gradual decrease in the volume of the subcutaneous lesions over 4 weeks, with smaller lesions and quicker resolution with ND0701 at concentrations 2.5- to 5-fold higher when compared to the commercial apomorphine HCl formulation. Histopathological evaluation of ND0701 revealed only minimal inflammation at the sites of infusion, whereas the commercial apomorphine HCl caused persistent inflammatory reactions and necrosis. This study provides support to the use of MRI in preclinical testing of subcutaneous drugs when evaluating local site reactions.


Assuntos
Antiparkinsonianos/efeitos adversos , Apomorfina/efeitos adversos , Reação no Local da Injeção/diagnóstico por imagem , Injeções Subcutâneas/efeitos adversos , Imageamento por Ressonância Magnética , Animais , Antiparkinsonianos/administração & dosagem , Apomorfina/administração & dosagem , Biomarcadores/sangue , Modelos Animais de Doenças , Avaliação Pré-Clínica de Medicamentos , Feminino , Masculino , Doença de Parkinson/tratamento farmacológico , Suínos
4.
Toxicol Sci ; 157(1): 3-7, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28329801

RESUMO

Practical magnetic resonance imaging for use in investigative and preclinical toxicology studies is now feasible. Newly developed, self-containing imaging systems provide an efficient and cost-effective means to rapidly obtain in vivo and ex vivo magnetic resonance imaging images to improve how we perform toxicology and toxicologic pathology.


Assuntos
Análise Custo-Benefício , Avaliação Pré-Clínica de Medicamentos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Imageamento por Ressonância Magnética/instrumentação , Animais , Imageamento por Ressonância Magnética/economia
5.
Neurotoxicology ; 59: 27-32, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28069364

RESUMO

Stem cells are emerging as a promising new treatment modality for a variety of central nervous system disorders. However, their use is hampered by the potential for the development of teratomas and other tumors. Therefore, there is a crucial need for the development of methods for detecting teratomas in preclinical safety studies. The aim of the current study is to assess the ability of a compact Magnetic Resonance Imaging (MRI) system to detect teratoma formation in mice. Five NOD-SCID mice were injected intrathecally with human embryonic stem cells (hESCs), with two mice serving as controls. In vivo MRI was performed on days 25 and 48, and ex vivo MRI was performed after scheduled euthanization (day 55). MRI results were compared to histopathology findings. Two animals injected with hESCs developed hind-limb paresis and paralysis, necessitating premature euthanization. MRI examination revealed abnormal pale areas in the spinal cord and brain, which correlated histopathologically with teratomas. This preliminary study shows the efficacy of compact MRI systems in the detection of small teratomas following intrathecal injection of hESCs in a highly sensitive manner. Although these results should be validated in larger studies, they provide further evidence that the use of MRI in longitudinal studies offers a new monitoring strategy for preclinical testing of stem cell applications.


Assuntos
Neoplasias do Sistema Nervoso Central/diagnóstico por imagem , Neoplasias do Sistema Nervoso Central/etiologia , Células-Tronco Embrionárias , Imageamento por Ressonância Magnética , Teratoma/diagnóstico por imagem , Teratoma/etiologia , Animais , Células-Tronco Embrionárias/patologia , Células-Tronco Embrionárias/transplante , Humanos , Processamento de Imagem Assistida por Computador , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , Necrose/patologia , Próteses e Implantes/efeitos adversos , Fatores de Tempo
6.
Toxicol Pathol ; 43(5): 633-50, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25694086

RESUMO

Magnetic resonance imaging (MRI) is widely used in preclinical research and drug development and is a powerful noninvasive method for assessment of phenotypes and therapeutic efficacy in murine models of disease. In vivo MRI provides an opportunity for longitudinal evaluation of tissue changes and phenotypic expression in experimental animal models. Ex vivo MRI of fixed samples permits a thorough examination of multiple digital slices while leaving the specimen intact for subsequent conventional hematoxylin and eosin (H&E) histology. With the advent of new compact MRI systems that are designed to operate in most conventional labs without the cost, complexity, and infrastructure needs of conventional MRI systems, the possibility of MRI becoming a practical modality is now viable. The purpose of this study was to investigate the capabilities of a new compact, high-performance MRI platform (M2™; Aspect Imaging, Israel) as it relates to preclinical toxicology studies. This overview will provide examples of major organ system pathologies with an emphasis on how compact MRI can serve as an important adjunct to conventional pathology by nondestructively providing 3-dimensional (3-D) digital data sets, detailed morphological insights, and quantitative information. Comparative data using compact MRI for both in vivo and ex vivo are provided as well as validation using conventional H&E.


Assuntos
Técnicas Histológicas/métodos , Imageamento por Ressonância Magnética/métodos , Patologia/métodos , Toxicologia/métodos , Animais , Humanos
7.
Immunology ; 133(2): 190-6, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21517838

RESUMO

The reason(s) why individual cytotoxic T lymphocytes (CTL) possess a fast-acting, perforin/granzyme-mediated, as well as a much slower, Fas ligand (FasL) -driven killing mechanism is not clear, nor is the basis for wide variations in killing activity exhibited by individual CTL, ranging from minutes to hours. We show that perforin expression among individual, conjugated CTL varies widely, which can account for the heterogeneity in killing speeds exhibited by individual CTL. Despite a 2-hr lag in FasL-based killing, CTL lytic action is enhanced when the two mechanisms operate in concert. This is explained by finding that the two pathways in fact are jump-started simultaneously with the lag in FasL lytic action reflecting pre-lytic caspase-8 activation and BH3-interacting domain (BID) cleavage. The complementary action of the two lytic pathways, co-expressed at varying levels among individual CTL, facilitates the lytic action of late-stage poor perforin-expressing CTL, ensuring optimal cytocidal action throughout the CTL response.


Assuntos
Proteína Ligante Fas/metabolismo , Perforina/metabolismo , Linfócitos T Citotóxicos/imunologia , Animais , Western Blotting , Citotoxinas/metabolismo , Citometria de Fluxo , Regulação da Expressão Gênica , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Perforina/genética , Subpopulações de Linfócitos T/imunologia
8.
Lab Chip ; 9(20): 2965-72, 2009 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-19789751

RESUMO

Advances in molecular cell biology, medical research, and drug development are driving a growing need for technologies that enable imaging the dynamics of molecular and physiological processes simultaneously in numerous non-adherent living cells. Here we describe a platform technology and software--the CKChip system--that enables continuous, fluorescence-based imaging of thousands of individual living cells, each held at a given position ("address") on the chip. The system allows for sequential monitoring, manipulation and kinetic analyses of the effects of drugs, biological response modifiers and gene expression in both adherent and non-adherent cells held on the chip. Here we present four specific applications that demonstrate the utility of the system including monitoring kinetics of reactive oxygen species generation, assessing the intracellular enzymatic activity, measuring calcium flux and the dynamics of target cell killing induced by conjugated cytotoxic T-lymphocytes. We found large variations among individual cells in the overall amplitude of their response to stimuli, as well as in kinetic parameters such as time of onset, initial rate and decay of the response, and frequency and amplitude of oscillations. These variations probably reflect the heterogeneity of even cloned cell populations that would have gone undetected in bulk cell measurements. We demonstrate the utility of the system in providing kinetic parameters of complex cellular processes such as Ca++ influx, transients and oscillations in numerous individual cells. The CKChip opens up new opportunities in cell-based research, in particular for acquiring fluorescence-based, kinetic data from multiple, individual non-adherent cells.


Assuntos
Técnicas de Cultura de Células/instrumentação , Técnicas Citológicas/instrumentação , Animais , Cálcio/imunologia , Linhagem Celular Tumoral , Fenômenos Fisiológicos Celulares , Desenho de Equipamento , Humanos , Imunoglobulina E/imunologia , Células Jurkat , Camundongos , Camundongos Endogâmicos C57BL , Espécies Reativas de Oxigênio/metabolismo , Linfócitos T Citotóxicos/imunologia
9.
Clin Dev Immunol ; 12(3): 187-95, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16295524

RESUMO

The CellScan apparatus is a laser scanning cytometer enabling repetitive fluorescence intensity (FI) and polarization (FP) measurements in living cells, as a means of monitoring lymphocyte activation. The CellScan may serve as a tool for diagnosis of rheumatoid arthritis (RA) and systemic lupus erythematosus (SLE) as well as other autoimmune diseases by monitoring FP changes in peripheral blood lymphocytes (PBLs) following exposure to autoantigenic stimuli. Changes in FI and FP in atherosclerotic patients' PBLs following exposure to various stimuli have established the role of the immune system in atherosclerotic disease. The CellScan has been evaluated as a diagnostic tool for drug-allergy, based on FP reduction in PBLs following incubation with allergenic drugs. FI and FP changes in cancer cells have been found to be well correlated with the cytotoxic effect of anti-neoplastic drugs. In conclusion, the CellScan has a variety of applications in cell biology, immunology, cancer research and clinical pharmacology.


Assuntos
Alergia e Imunologia/instrumentação , Citofotometria/instrumentação , Polarização de Fluorescência/instrumentação , Apoptose , Autoimunidade , Hipersensibilidade a Drogas/diagnóstico , Enzimas/metabolismo , Citometria de Fluxo , Humanos , Citometria por Imagem , Ativação Linfocitária , Oncologia/instrumentação , Neoplasias/diagnóstico , Neoplasias/imunologia , Farmacologia Clínica/instrumentação
10.
J Immunol Methods ; 277(1-2): 39-52, 2003 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-12799038

RESUMO

The recent advent of peptide-MHC tetramers has provided a new and effective tool for studying antigen-specific T cell populations through monitoring tetramer binding to T cells by flow cytometry. Yet information regarding T cell activation induced by the bound tetramers cannot be deduced from binding studies alone; complementary methods are needed to bridge this gap. To this end, we have developed a new approach that now enables monitoring both binding to and activation of T cells by peptide-MHC tetramers at the single-cell level. For this purpose, we have employed the CellScan, a non-flow cytometer designed for repetitive measurements of optical parameters (e.g., fluorescence intensity and polarization) of individual living cells. A melanoma-specific MART1 CTL line and a gp100-specific CTL clone were incubated with specific and control single-chain peptide-MHC tetramers for 45 min. Subsequently, the fluorescence intensity and polarization were measured by the CellScan. Specific binding of fluorescently labeled peptide-MHC tetramers to CTLs, recorded by the CellScan, was comparable to that measured by flow cytometry. CellScan monitoring of the degree of fluorescence polarization of fluorescein diacetate-labeled CTLs that were reacted with tetramers revealed specific activation of the CTLs, which was confirmed by cytokine (INF gamma) production. These results provide a new means of monitoring both the binding to and activation of T lymphocytes by cognate peptide-MHC complexes at the single-cell level, which can now be applied to distinguish between cognate responding and anergic T cells.


Assuntos
Polarização de Fluorescência/métodos , Complexo Principal de Histocompatibilidade/imunologia , Linfócitos T/imunologia , Epitopos de Linfócito T/imunologia , Epitopos de Linfócito T/metabolismo , Polarização de Fluorescência/instrumentação , Humanos , Interferon gama/imunologia , Interferon gama/metabolismo , Cinética , Ativação Linfocitária/imunologia , Melanoma/imunologia , Melanoma/metabolismo , Peptídeos/imunologia , Peptídeos/metabolismo , Linfócitos T/metabolismo , Células Tumorais Cultivadas
11.
Gynecol Oncol ; 84(2): 296-302, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11812090

RESUMO

OBJECTIVE: The goal of this work was to evaluate the involvement of gonadotropins in the regulation of adhesion of human epithelial ovarian carcinoma. We studied two pathways that were previously implicated in the metastatic implantation of ovarian carcinoma to the peritoneum, namely hyaluronan-CD44 and RGD-integrin mediated adhesion. METHODS: Two cell lines derived from human epithelial ovarian carcinoma (MLS and OC238) were stimulated with luteinizing hormone (LH) and/or follicle stimulating hormone (FSH). Expression of CD44 was evaluated by Western blotting. Expression of alpha(v)-integrins was studied by RT-PCR and Northern blot. Integrin and CD44 mediated adhesion of the cells was analyzed using culture plates coated either with a thrombin derived RGD containing peptide or fibronectin for integrin mediated adhesion or with hyaluronan for CD44 mediated adhesion. RESULTS: MLS cells stimulated with either LH or FSH showed increased adhesion to culture plates coated with hyaluronan, as well as to culture plates coated with fibronectin or with a thrombin derived RGD containing peptide. In these cells, gonadotropin stimulation led to induced expression of the integrin subunit alpha(v) and CD44, the cell surface hyaluronan receptor. On the other hand, OC238 cells showed no expression of the integrin subunit alpha(v) and no hormonal effect on the expression of CD44. Accordingly, adhesion of OC238 cells on either RGD or CD44 was not affected by hormonal stimulation. CONCLUSION: Elevated levels of gonadotropins may in some cases facilitate peritoneal metastatic dissemination of ovarian cancer by increasing cell adhesion, the first essential step in the invasion process.


Assuntos
Antígenos CD/fisiologia , Hormônio Foliculoestimulante/farmacologia , Receptores de Hialuronatos/fisiologia , Hormônio Luteinizante/farmacologia , Neoplasias Ovarianas/patologia , Antígenos CD/biossíntese , Western Blotting , Adesão Celular/efeitos dos fármacos , Adesão Celular/fisiologia , Células Epiteliais/patologia , Feminino , Hormônio Foliculoestimulante/metabolismo , Hormônio Foliculoestimulante/fisiologia , Humanos , Receptores de Hialuronatos/biossíntese , Ácido Hialurônico/farmacologia , Integrina alfaV , Hormônio Luteinizante/metabolismo , Hormônio Luteinizante/fisiologia , Oligopeptídeos/farmacologia , Neoplasias Ovarianas/metabolismo , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Células Tumorais Cultivadas
12.
Anticancer Res ; 22(5): 2663-9, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12529979

RESUMO

BACKGROUND: We used the CellScan, a novel static cytometer, to monitor changes induced by anti-neoplastic drugs in the fluorescence intensity and polarization of fluorescently-labeled tumor cells. MATERIALS AND METHODS: T47D and T80 human breast cancer cell lines were exposed to navelbine and to 5-fluorouracil and the fluorescence properties of the treated cells, stained with fluorescein diacetate and rhodamine 123, were measured by the CellScan. RESULTS: A strong correlation was found between the inhibition of cell growth induced by the two drugs, as estimated from cell counts, and the resulting changes in fluorescence intensity and polarization, as monitored by the CellScan. Fluorescence hyperpolarization of the labeled cells occurred in conjunction with AnnexinV binding and propidium iodide exclusion, indicating that such hyperpolarization, resulting from drug action, reflects an early stage of apoptosis, as previously proposed. CONCLUSION: The system presented here could serve as the basis for assessing drug sensitivity or resistance of cancer cells derived from small biopsies of solid human tumors, thus eliminating prior tumor culturing and time-consuming assays.


Assuntos
Ensaios de Seleção de Medicamentos Antitumorais/métodos , Polarização de Fluorescência/métodos , Vimblastina/análogos & derivados , Anexina A5/metabolismo , Antineoplásicos/farmacologia , Apoptose/efeitos dos fármacos , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Divisão Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Fluoresceínas/metabolismo , Corantes Fluorescentes/metabolismo , Fluoruracila/farmacologia , Humanos , Valor Preditivo dos Testes , Propídio/metabolismo , Rodamina 123/metabolismo , Células Tumorais Cultivadas , Vimblastina/farmacologia , Vinorelbina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA