Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Nuklearmedizin ; 49(5): 195-201, 2010.
Artigo em Alemão | MEDLINE | ID: mdl-20838734

RESUMO

In nuclear medicine, bone scanning is based on the principle of scintigraphy using bone-seeking radiopharmaceuticals which accumulate in sites of increased bone formation. From a historical point of view, (18)F-fluoride was one of the first osteotropic tracers which was replaced by (99m)Tc-labelled polyphosphonates. With the development of modern PET equipment the superior diagnostic performance of (18)F-fluoride PET for the detection and characterization of osseous lesions was proven in comparison to conventional bone scanning. Recently, its importance as a substitute of conventional skeletal scintigraphy increased in a time with limited availability of (99)Mo/(99m)Tc. To ensure health care during this period, (18)F-fluoride PET currently became part of common outpatient care. This guideline comprehends recommendations on indications, protocols, interpretation and reporting of (18)F-fluoride PET and PET/CT.


Assuntos
Osso e Ossos/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons/métodos , Fluoreto de Sódio , Fluoretos , Alemanha , Humanos , Molibdênio , Tomografia Computadorizada por Raios X/métodos
2.
Ann Oncol ; 19(9): 1619-23, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18453520

RESUMO

PURPOSE: The aim of this study was to determine the predictive values of 2-[fluorine-18]fluoro-2-deoxy-D-glucose-positron emission tomography (FDG-PET) in primary staging in patients with newly diagnosed non-seminomatous germ cell tumour (NSGCT) clinical stage I/II. PATIENTS AND METHODS: The hypothesis was that FDG-PET would improve the negative predictive value (NPV) from 70% to 90%, thus requiring a total of 169 patients. All scans underwent visual analysis by a reference team of nuclear medicine physicians. Results were validated by histology following retroperitoneal lymph node dissection. RESULTS: Only 72 of the planned 169 patients were included, due to poor accrual. The prevalence of nodal involvement was 26%. Correct nodal staging by FDG-PET was achieved in 83% compared with correct computed tomography (CT) staging in 71%. CT had a sensitivity and specificity of 41% and 95%, respectively. Positive predictive value (PPV) and NPV were 87% and 67%, respectively. FDG-PET had a sensitivity and specificity of 66% and 98%, respectively. PPV was 95%. The primary end point was not reached, with an NPV of 78%. CONCLUSION: FDG-PET as a primary staging tool for NSGCT yielded only slightly better results than CT. Both methods had a high specificity while false-negative findings were more frequent with CT. FDG-PET is mostly useful as a diagnostic tool in case of questionable CT scan.


Assuntos
Invasividade Neoplásica/patologia , Neoplasias Embrionárias de Células Germinativas/diagnóstico por imagem , Neoplasias Embrionárias de Células Germinativas/patologia , Tomografia por Emissão de Pósitrons , Neoplasias Testiculares/diagnóstico por imagem , Neoplasias Testiculares/patologia , Adolescente , Adulto , Fluordesoxiglucose F18 , Alemanha , Humanos , Excisão de Linfonodo/métodos , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Embrionárias de Células Germinativas/cirurgia , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Sensibilidade e Especificidade , Neoplasias Testiculares/cirurgia , Tomografia Computadorizada por Raios X/métodos
3.
Dement Geriatr Cogn Disord ; 19(1): 24-30, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15383742

RESUMO

BACKGROUND: It is not known yet whether temporoparietal glucose hypometabolism in patients with probable Alzheimer's disease (AD) reflects disease severity or different subtypes of patients. METHODS: Twenty-five subjects with mild probable AD [NINCDS-ADRDA criteria; age 65.8 +/- 9.3 years (mean +/- SD); Mini-Mental State Examination (MMSE) 26.0 +/- 3.3] were investigated. [(18)F]FDG-PET data were analyzed visually with raters blinded to the diagnosis and with a quantitative analysis in the region of interest on individual anatomically normalized PET scans. RESULTS: Thirteen of 25 patients showed temporoparietal hypometabolism on visual inspection (PET+; age 65.7 +/- 10.7), 12 patients had normal FDG-PET results (PET-; age 65.9 +/- 8.0; n.s.). The MMSE and immediate reproduction of the Wechsler Memory Scale (WMS-R-I) were 27.7 +/- 1.9 and 31.1 +/- 6.1 in the PET- vs. 24.5 +/- 3.6 (p = 0.012) and 22.0 +/- 7.4 (p = 0.006) in the PET+ group. Immediate and delayed recall in the California Verbal Learning Test and delayed reproduction in the Wechsler Memory Scale were alike. Regression analysis revealed a significant correlation of temporoparietal glucose metabolism with the block span (r = 0.60; p < 0.01) and the WMS-R-I (r = 0.68; p < 0.01) but not with measures of hippocampal function. CONCLUSIONS: Temporoparietal glucose metabolism in patients with very mild AD is a sign of disease spread beyond the temporal lobe. This may aid in establishing objective parameters for future therapeutic studies.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Glicemia/metabolismo , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Idoso , Amnésia/diagnóstico por imagem , Progressão da Doença , Feminino , Fluordesoxiglucose F18 , Hipocampo/diagnóstico por imagem , Humanos , Masculino , Memória de Curto Prazo/fisiologia , Entrevista Psiquiátrica Padronizada , Pessoa de Meia-Idade , Lobo Parietal/diagnóstico por imagem , Estatística como Assunto , Lobo Temporal/diagnóstico por imagem
5.
Thorac Cardiovasc Surg ; 52(2): 96-101, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15103582

RESUMO

BACKGROUND: Mediastinal lymph node staging is essential to determine treatment options in patients with NSCLC. Positron emission tomography (PET) detects increased glucose uptake in malignant tissue using the glucose analogue 2-[(18)F]fluoro-2-deoxy-D-glucose (FDG). PATIENTS AND METHODS: In the present study were evaluated 155 patients with focal pulmonary tumors who underwent both preoperative computed tomography (CT) and FDG-PET scanning (116 malignant and 39 benign lesions). RESULTS: Findings in 155 patients included 116 malignant and 39 benign lesions. For N-staging, FDG-PET showed a sensitivity of 88%, a specificity of 91%, and an accuracy of 89%. Corresponding figures for CT were 77%, 76%, and 77%, respectively. CONCLUSIONS: FDG-PET is an effective, noninvasive method for staging thoracic lymph nodes in patients with lung cancer and is superior to CT scanning in the assessment of hilar and mediastinal nodal metastases. With regard to operability, FDG-PET could differentiate reliable between patients with N1/N2 disease and those with unresectable N3 disease.


Assuntos
Adenocarcinoma/diagnóstico , Adenocarcinoma/patologia , Carcinoma de Células Grandes/diagnóstico , Carcinoma de Células Grandes/patologia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/patologia , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão , Adulto , Idoso , Tumor Carcinoide/diagnóstico , Tumor Carcinoide/patologia , Reações Falso-Positivas , Feminino , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
6.
J Thorac Cardiovasc Surg ; 127(4): 1093-9, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15052207

RESUMO

BACKGROUND: 2-[(18)F]-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography has been established as a standard diagnostic imaging method in the preoperative workup of suspicious pulmonary focal lesions, showing a sensitivity of more than 90% and a specificity of about 80%. Determination of malignant pulmonary lesions with FDG positron emission tomography depends on the assessment of glucose metabolism. However, false-positive findings can occur in inflammatory processes, such as sarcoidosis or pneumonia. The thymidine analogue 3-deoxy-3[(18)F]-fluorothymidine (FLT) is a new positron emission tomography tracer that more specifically targets proliferative activity of malignant lesions. The objective of this study was to determine whether FLT positron emission tomography, in comparison with FDG positron emission tomography, provides additional information in the preoperative workup of central pulmonary focal lesions. METHODS: In this prospective study FLT and FDG positron emission tomography examinations were performed as a part of the preoperative workup in 20 patients with histologically confirmed bronchial carcinoma, 7 patients with benign lesions, and 1 patient with an atypical carcinoid. Results were compared with final pathologic findings. RESULTS: For staging of the primary tumor, FLT positron emission tomography revealed a sensitivity of 86% and a specificity of 100% compared with a sensitivity of 95% and a specificity of 73% for FDG positron emission tomography. For N staging, the sensitivity of FLT positron emission tomography was 57% and the specificity was 100%, and for FDG positron emission tomography, the sensitivity was 86% and the specificity was 100%, respectively. CONCLUSIONS: Our preliminary findings indicate specific FLT uptake in malignant lesions. The number of false-positive findings in FDG positron emission tomography might be reduced with FLT positron emission tomography. Therefore positron emission tomography imaging with FLT represents a useful supplement to FDG in assessing the malignancy of central pulmonary focal lesions.


Assuntos
Adenocarcinoma/diagnóstico , Carcinoma Broncogênico/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma de Células Escamosas/diagnóstico , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão , Adenocarcinoma/patologia , Adulto , Idoso , Carcinoma Broncogênico/patologia , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma de Células Escamosas/patologia , Reações Falso-Positivas , Feminino , Humanos , Neoplasias Pulmonares/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Primárias Múltiplas/diagnóstico , Neoplasias Primárias Múltiplas/patologia , Estudos Prospectivos , Sensibilidade e Especificidade
7.
Eur J Surg Oncol ; 30(3): 252-9, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15028305

RESUMO

PURPOSE: To analyse the reliability of sentinel-node biopsy (SNB) in a multicentre setting and define conditions for the routine use of the procedure. MATERIAL AND METHODS: SNB with consecutive axillary clearing was performed in 1124 breast cancer patients. The detection rate of a sentinel lymph node and its dependence on the choice of lymphography technique, patient selection, and technical procedure were analysed. The diagnostic performance of the sentinel-node method was compared to clinical, ultrasound-guided and histological staging. In order to study training effects all learning periods were included. RESULTS: Twenty-two institutions with a total of 89 surgeons participated in the trial. The detection rate (overall: 85.2%) was found to be related to the applied lymphography technique, the experience of the institution and various technical factors of the procedure itself. The false-negative rate (FNR, overall: 8.2%) was independent of patient selection and technical features. The FNR did not depend on experience in the application of the method, but seemed related to surgical accuracy to detect sentinel nodes. Compared to conventional staging procedures (palpation, ultrasound) SNB yielded highly reproducible results for the prediction of the axillary status even in a multicentre setting involving surgeons with different training status. CONCLUSION: SNB is suited as standard of care procedure. Measures of quality control appear more important than learning periods to minimize the FNR.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/patologia , Carcinoma Lobular/patologia , Linfonodos/patologia , Biópsia de Linfonodo Sentinela/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Axila , Feminino , Humanos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
Nuklearmedizin ; 43(1): 4-9, 2004 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-14978534

RESUMO

The international consensus conference from St. Gallen concerning the treatment of early breast cancer concluded in 2003, that sentinel node biopsy was now accepted as method allowing axillary staging in breast cancer. This procedure may avoid complete lymph node dissection in appropriate cases. Since numerous questions associated with the technique are still not defined and the procedure itself is not yet standardized, the German Society of Senology defined the conditions for the routine clinical use of sentinel node biopsy in an interdisciplinary consensus meeting.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Biópsia de Linfonodo Sentinela/normas , Feminino , Alemanha , Humanos , Estadiamento de Neoplasias/normas , Garantia da Qualidade dos Cuidados de Saúde , Radiografia
9.
Br J Radiol ; 75(898): 789-98, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12381687

RESUMO

This study compared pre-operative staging with MR mammography (MRM) and positron emission tomography (PET) in patients with clinically suspected breast cancer according to the Breast Imaging Reporting and Data System, category 5. A total of 43 patients with breast cancer were examined. MRM included both T(2) weighted turbo spin echo sequences and T(1) weighted gradient echo sequences (three-dimensional fast low angle shot) before and after application of gadolinium-DPTA. All patients then underwent examination with a modern full-ring PET scanner following injection of fluorodeoxyglucose. We evaluated the efficacy of these methods in the diagnosis of primary tumour, contralateral carcinomas, bifocal, trifocal or multifocal disease, as well as non-invasive cancer portions and tumour size. Determination of patients' N-status was only attempted using PET. All findings were validated by histological examination. MRM was slightly superior to PET in several areas, such as in the respective methods' sensitivity and specificity. Sensitivities for MRM and PET were: 100% vs 93.0% in diagnosis of the primary tumour; 100% vs 100% in diagnosis of contralateral carcinomas; and 95.2% vs 92.5% in diagnosis of bifocal, trifocal or multifocal disease. Specificities for MRM and PET were: 100% vs 97.5% in diagnosis of contralateral carcinomas; and 96.8% vs 90.3% in diagnosis of bifocal, trifocal or multifocal disease. Non-invasive cancer portions and tumour sizes were equally well determined with both methods. The sensitivity of PET for detection of lymph node involvement was 80% and specificity 95%. MRM and PET were superior to conventional methods in nearly all areas studied; the findings of one or both of the methods impacted positively on patients' surgical treatment in 12.5-15% of cases. Pre-operative MRM and/or PET can have a positive influence on surgical treatment planning. Therefore, it appears useful to perform pre-operative staging with MRM or PET in these patients.


Assuntos
Neoplasias da Mama/diagnóstico , Mamografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Invasividade Neoplásica , Estadiamento de Neoplasias/métodos , Cuidados Pré-Operatórios/métodos , Tomografia Computadorizada de Emissão/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
10.
Eur J Nucl Med Mol Imaging ; 29(3): 361-6, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12002711

RESUMO

This prospective study was undertaken to investigate the appearance of multiple myeloma on fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET). Furthermore, the accuracy of FDG-PET in detecting myeloma lesions and its influence on patient management were evaluated. Forty-three patients with known multiple myeloma (n=28) or solitary plasmacytoma (n=15) underwent FDG-PET. The results of routinely performed radiographs and of scans obtained using all available imaging modalities (MRI, CT), as well as the clinical course, were used for verification of detected lesions. Focally increased tracer uptake was observed in 38 of 41 known osteolytic bone lesions (sensitivity 92.7%) in 23 patients. In addition, 71 further bone lesions which were negative on radiographs were detected in 14 patients. Twenty-six (36.6%) of these lesions could be confirmed in ten patients. As a result of FDG-PET imaging, clinical management was influenced in five (14.0%) patients. The positive predictive value for active disease was 100% in patients with focal or mixed focal/diffuse skeletal FDG uptake and 75% in patients with diffuse bone marrow uptake. Depending on the interpretation of the PET scans in patients with diffuse bone marrow uptake, the sensitivity ranged from 83.8% to 91.9% and the specificity from 83.3% to 100%. FDG-PET thus proved highly accurate in detecting multiple myeloma, and revealed a greater extent of disease than routine radiographs in 14 of 23 (60.9%) patients who had osteolytic bone lesions. FDG-PET might contribute to the initial staging of solitary plasmacytoma.


Assuntos
Fluordesoxiglucose F18/farmacocinética , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/metabolismo , Adulto , Idoso , Reações Falso-Positivas , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Mieloma Múltiplo/diagnóstico , Estadiamento de Neoplasias/métodos , Estudos Prospectivos , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Método Simples-Cego , Tomografia Computadorizada de Emissão/métodos
11.
J Nucl Med ; 42(12): 1800-4, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11752076

RESUMO

UNLABELLED: Previous studies have shown that vertebral bone metastases (BM) not seen on planar bone scintigraphy (BS) might be present on (18)F-fluoride PET scans or at MRI. Therefore, we evaluated the effect of SPECT or (18)F-labeled NaF PET ((18)F PET) imaging on the management of patients with newly diagnosed lung cancer. METHODS: Fifty-three patients with small cell lung cancer or locally advanced non-small cell lung cancer were prospectively examined with planar BS, SPECT of the vertebral column, and (18)F PET. MRI and all available imaging methods, as well as the clinical course, were used as reference methods. BS with and without SPECT and (18)F PET were compared using a 5-point scale for receiver operating characteristic (ROC) curve analysis. RESULTS: Twelve patients had BM. BS produced 6 false-negatives, SPECT produced 1 false-negative, and (18)F PET produced no false-negatives. The area under the ROC curve was 0.779 for BS, 0.944 for SPECT, and 0.993 for (18)F PET. The areas under the ROC curve of (18)F PET and BS complemented by SPECT were not significantly different, and both tomographic methods were significantly more accurate than planar BS. As a result of SPECT or (18)F PET imaging, clinical management was changed in 5 patients (9%) or 6 patients (11%), respectively. CONCLUSION: As indicated by the area under the ROC curve analysis, (18)F PET is the most accurate whole-body imaging modality for screening for BM. Routinely performed SPECT imaging is practicable, is cost-effective, and improves the accuracy of BS.


Assuntos
Radioisótopos de Flúor , Neoplasias Pulmonares/patologia , Fluoreto de Sódio , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/secundário , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada de Emissão , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/secundário , Carcinoma de Células Pequenas/diagnóstico por imagem , Carcinoma de Células Pequenas/secundário , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
12.
Thyroid ; 11(7): 677-83, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11484897

RESUMO

Currently, bone scintigraphy (BS) is considered to lack sensitivity in detecting bone metastases (BM) from thyroid cancer. We evaluated the anatomical distribution and metabolic behavior of BM as well as the accuracy of BS with and without combination of whole-body iodine scintigraphy (WBI) in detecting metastatic bone disease in thyroid carcinoma. F-18 positron emission tomography (PET), x-ray, BS, and WBI were performed in 35 patients with known or suspected bone metastases from papillary (9 patients) or follicular (26 patients) thyroid carcinoma. Twenty-two metastases were previously known in 14 patients. The indication was staging in 21 patients with high risk for BM, elevated thyroglobulin (Tg)-levels or evaluation of exact extent of BM (14 patients). In addition, results of WBI (35 patients), X-ray (35 patients) F-18 PET (35 patients), MRI of the spine (13 patients), and FDG-PET (15 patients) as well as the clinical course (1.5-4 years) were correlated. BM were detected in 18 patients. Solitary, bifocal, or multiple lesions were present in 9, 2, and 7 patients, respectively. The anatomical distribution of BM (n = 43) was as follows: spine, 42%; skull, 2%; thorax, 16%; femur, 9%; pelvis, 26%; humerus and clavicle, 5%. Sensitivity of BS in interpreting patients as positive or negative for having BM was 64%-85% (specificity, 95%-81%). The combination of BS and WBI was 100% sensitive in detecting metastatic bone disease. One patient had a single BM that was positive at BS but negative on WBI. All metastases were osteolytic on x-ray and two-thirds presented a missing or very limited osteosclerotic bone reaction on F-18 PET. Our data confirm the limited sensitivity of planar BS in detecting BM from thyroid cancer. The combination of BS and WBI, however, was highly accurate. Compared to other malignancies, the distribution pattern of BM presented a lower percentage of vertebral metastases and more patients with single metastases. Those findings in combination with a missing or only slight osteosclerotic bone reaction explain the limited sensitivity of planar BS alone.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Radioisótopos de Flúor , Fluoreto de Sódio , Neoplasias da Glândula Tireoide/patologia , Tomografia Computadorizada de Emissão , Adulto , Idoso , Idoso de 80 Anos ou mais , Osso e Ossos/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose , Sensibilidade e Especificidade , Contagem Corporal Total
13.
J Neural Transm (Vienna) ; 108(6): 661-70, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11478418

RESUMO

Permanent verbal, visual scenic and coenaestetic hallucinations are the most prominent psychopathological symptoms aside from psychomotor disorders in speech-sluggish catatonia, a subtype of chronic catatonic schizophrenia according to Karl Leonhard. These continuous hallucinations serve as an excellent paradigm for the investigation of the assumed functional disturbances of cortical circuits in schizophrenia. Data from positron emission tomography (F-18-FDG-PET and F-18-DOPA-PET) from three patients with this rare phenotype were available (two cases of simple speech-sluggish catatonia, one case of a combined speech-prompt/speech-sluggish subtype) and were compared with a control collective. During their permanent hallucinations, all catatonic patients showed a clear bitemporal hypometabolism in the F-18-FDG-PET. Both patients with the simple speech-sluggish catatonia showed an additional bilateral thalamic hypermetabolism and an additional bilateral hypometabolism of the frontal cortex, especially on the left side. In contrast, the patient with the combined speech-prompt/speech-sluggish catatonia showed a bilateral thalamic hypometabolism combined with a bifrontal cortical hypermetabolism. However, the left/right ratio of the frontal cortex also showed a lateralisation effect with a clear relative hypometabolism of the left frontal cortex. The F-18-DOPA-PET of both schizophrenic patients with simple speech-sluggish catatonia showed a normal F-18-DOPA storage in the striatum, whereas in the right putamen of the patient with the combined form a higher right/left ratio in F-DOPA storage was discernible, indicating an additional lateralized influence of the dopaminergic system in this subtype of chronic catatonic schizophrenia. Most likely, the prominent bitemporal F-18-FDG- hypometabolism in these chronic schizophrenic patients with speech-sluggish catatonia suffering from permanent continuous hallucinations, reflects a deficit in sensoric gating following prenatal cortical neurodevelopmental disturbances. However, the functional disturbances underlying hallucinations in "the schizophrenias" seem to be more complex; in different subtypes of the schizophrenic spectrum disorder hallucinations seem to be based on alterations in additional cortical and subcortical brain regions.


Assuntos
Di-Hidroxifenilalanina/análogos & derivados , Esquizofrenia Catatônica/diagnóstico por imagem , Esquizofrenia Catatônica/metabolismo , Tomografia Computadorizada de Emissão , Adulto , Encéfalo/metabolismo , Doença Crônica , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Glucose/metabolismo , Humanos , Vias Neurais/metabolismo , Compostos Radiofarmacêuticos , Fala
14.
J Nucl Med ; 42(5): 721-5, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11337566

RESUMO

UNLABELLED: PET with 18F-FDG has been shown to be useful in the detection and staging of pancreatic cancer. However, whether FDG uptake is dependent on proliferative activity is still unclear. The aim of this prospective study was to evaluate a probable correlation between FDG uptake and proliferative activity in benign and malignant pancreatic tumors. METHODS: Our series consisted of 23 patients with pancreatic cancer and 9 patients with chronic active pancreatitis (CAP). FDG PET was performed within 2 wk before surgery, and standardized uptake values (SUVs) were calculated for benign and malignant pancreatic tumors. Patients were selected when focally increased FDG uptake in previously known pancreatic tumors was present. Proliferation fraction was measured in tissue specimens using the anti-Ki-67 antibody MIB-1. A computer-assisted imaging system was used for quantification of nuclear Ki-67 immunostaining. Immunohistochemical findings were correlated to SUVS: RESULTS: Pancreatic cancer showed both intense nuclear staining of Ki-67 (39% +/- 16%) and high FDG uptake (SUV = 3.6 +/- 1.6). However, no significant correlation was found between in vivo FDG uptake and Ki-67 immunoreactivity (P = 0.65). By contrast, Ki-67 nuclear staining was significantly lower (3.8% +/- 2.7%, P < 0.05) in CAP, whereas FDG uptake was in the same range as for pancreatic cancer (SUV = 3.5 +/- 1.8). CONCLUSION: FDG uptake did not correlate with proliferative activity in pancreatic cancer. Proliferative activity was tenfold higher in malignant pancreatic tumors than in benign tumors associated with CAP, whereas FDG uptake in vivo did not differ significantly. Thus, a PET tracer indicating cellular proliferation should better differentiate between cancer and inflammatory lesions than do metabolic markers such as FDG.


Assuntos
Carcinoma/diagnóstico por imagem , Fluordesoxiglucose F18 , Antígeno Ki-67/análise , Neoplasias Pancreáticas/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão , Adenocarcinoma/química , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma/química , Carcinoma/patologia , Divisão Celular , Núcleo Celular/química , Doença Crônica , Feminino , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Pancreáticas/química , Neoplasias Pancreáticas/patologia , Pancreatite/diagnóstico por imagem , Estudos Prospectivos
16.
Eur J Nucl Med ; 28(3): 351-8, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11315604

RESUMO

The present study compared the diagnostic accuracy of fluorine-18 2-deoxy-2-fluoro-D-glucose positron emission tomography (FDG-PET) with conventional staging techniques. The differentiation between malignant and benign lesions and the detection of multifocal disease, axillary and internal lymph node involvement, and distant metastases were evaluated. One hundred and seventeen female patients were prospectively examined using FDG-PET and conventional staging methods such as chest X-ray, ultrasonography of the breast and liver, mammography and bone scintigraphy. All patients were examined on a modern full-ring PET scanner. Histopathological analysis of resected specimens was employed as the reference method. The readers of FDG-PET were blinded to the results of the other imaging methods and to the site of the breast tumour. The sensitivity and specificity of FDG-PET in detecting malignant breast lesions were 93% and 75% respectively. FDG-PET was twofold more sensitive (sensitivity 63%, specificity 95%) in detecting multifocal lesions than the combination of mammography and ultrasonography (sensitivity 32%, specificity 93%). Sensitivity and specificity of FDG-PET in detecting axillary lymph node metastases were 79% and 92% (41% and 96% for clinical evaluation). FDG-PET correctly indicated distant metastases in seven patients. False-positive or false-negative findings were not encountered with FDG-PET. Chest X-ray was false-negative in three of five patients with lung metastases. Bone scintigraphy was false-positive in four patients. Three patients were upstaged since FDG-PET detected distant metastases missed with the standard staging procedure. It is concluded that, compared with the imaging methods currently employed for initial staging, FDG-PET is as accurate in interpreting the primary tumour and more accurate in screening for lymph node metastases and distant metastases. Due to a false-negative rate of 20% in detecting axillary lymph node metastases, FDG-PET cannot replace histological evaluation of axillary status.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Fluordesoxiglucose F18 , Estadiamento de Neoplasias/métodos , Compostos Radiofarmacêuticos , Adulto , Idoso , Idoso de 80 Anos ou mais , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Linfonodos/diagnóstico por imagem , Pessoa de Meia-Idade , Metástase Neoplásica/diagnóstico por imagem , Valores de Referência , Tomografia Computadorizada de Emissão
17.
Cancer ; 91(5): 889-99, 2001 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-11251940

RESUMO

BACKGROUND: The authors undertook a prospective evaluation of the clinical value of 2-fluoro [18-]-2-deoxyglucose positron emission tomography (FDG-PET) in the detection and staging of malignant lymphoma compared with computed tomography (CT) and bone marrow biopsy (BMB). METHODS: Fifty-two consecutive patients with untreated malignant lymphoma were evaluated prospectively in a bicenter study. FDG-PET, CT, and BMB were performed for investigating lymph node/extranodal manifestations and bone marrow infiltration. Thirty-three percnt of the discrepant results were verified by biopsy, magnetic resonance imaging, or clinical follow-up (range, 4-24 month). RESULTS: Altogether, 1297 anatomic regions (lymph nodes, organs, and bone marrow) were evaluated. FDG-PET and CT scans were compared by receiver operating characteristic (ROC) curve analysis. The area under the ROC curve were as follows: lymph nodes, 0.996 (PET) and 0.916 (CT); extranodal, 0.999 (PET) and 0.916 (CT); supradiaphragmatic, 0.996 (PET) and 0.905 (CT); and infradiaphragmatic, 0.999 (PET) and 0.952 (CT). In these analyses, FDG-PET was significantly superior to CT (P < 0.05), except in infradiaphragmatic regions, in which the two methods produced equivalent results. In detecting bone marrow infiltration, FDG-PET was superior to CT and was equivalent to BMB. In 4 of 52 patients (8%), FDG-PET led to an upstaging and a change of therapy. CONCLUSIONS: Noninvasive FDG-PET is very accurate in the staging of malignant lymphoma. Compared with standard staging modalities (CT and BMB), PET was significantly superior and led to changes in the therapy regimen for 8% of patients.


Assuntos
Antimetabólitos , Desoxiglucose , Radioisótopos de Flúor , Doença de Hodgkin/patologia , Linfoma não Hodgkin/patologia , Estadiamento de Neoplasias/métodos , Tomografia Computadorizada de Emissão , Adolescente , Adulto , Idoso , Biópsia , Medula Óssea/patologia , Feminino , Doença de Hodgkin/classificação , Humanos , Linfoma não Hodgkin/classificação , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Tomografia Computadorizada por Raios X
19.
Am J Surg ; 180(1): 1-5, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11036130

RESUMO

BACKGROUND: Accuracy of (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) and contribution to surgical decision making in recurrent or metastatic colorectal cancer were evaluated. METHODS: One hundred whole-body PET tests in colorectal cancer patients (1994 to 1998) were compared with computed tomography (CT), liver ultrasonography, and carcinoembryonic antigen (CEA) test. Mean follow-up was 12 months. RESULTS: Sensitivity, specificity, and accuracy of FDG-PET for malignant findings were, respectively, 98%, 90% and 95%; for 87 CT scans, 91%, 72%, and 82%; for 98 CEA tests, 76%, 90%, and 82%; for detection of liver metastases with PET, 100%, 99%, and 99%; and for 68 ultrasound tests, 87%, 96%, and 93%. PET accuracy for local recurrence was 96%. Additional information was provided by PET in 86% of cases (abdomen, thorax, liver). PET influenced surgical decisions in 61% of cases. CONCLUSION: FDG-PET adds relevant accuracy to the conventional staging of patients with colorectal cancer and may cost-effectively help to select the appropriate treatment.


Assuntos
Neoplasias do Colo/diagnóstico por imagem , Tomada de Decisões , Fluordesoxiglucose F18 , Recidiva Local de Neoplasia/diagnóstico por imagem , Planejamento de Assistência ao Paciente , Compostos Radiofarmacêuticos , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/cirurgia , Tomografia Computadorizada de Emissão , Neoplasias Abdominais/diagnóstico por imagem , Neoplasias Abdominais/secundário , Adulto , Idoso , Idoso de 80 Anos ou mais , Antígeno Carcinoembrionário/análise , Neoplasias do Colo/cirurgia , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/cirurgia , Sensibilidade e Especificidade , Neoplasias Torácicas/diagnóstico por imagem , Neoplasias Torácicas/secundário , Tomografia Computadorizada por Raios X , Ultrassonografia
20.
Recent Results Cancer Res ; 156: 78-89, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10802866

RESUMO

FDG-Positron emission tomography (FDG-PET) is an imaging modality using the physiological tracer glucose [modified as 18-fluorine-2-fluorodeoxyglucose (FDG)], whose uptake and metabolism is increased in malignant cells. While exact tumor staging in lymphomatous diseases is the basis for choosing the appropriate treatment strategy, the detection of nodal and extranodal manifestations are a key prerequisite. This study demonstrates that FDG-PET is an efficient, non-invasive method for the staging of primary untreated Hodgkin's lymphoma (HD) and non-Hodgkin's lymphoma (NHL). Clinical PET scanning is very useful in staging lymphoma patients and is more accurate than computed tomography (CT) in detecting lesions.


Assuntos
Doença de Hodgkin/diagnóstico por imagem , Doença de Hodgkin/patologia , Linfoma não Hodgkin/diagnóstico por imagem , Linfoma não Hodgkin/patologia , Tomografia Computadorizada de Emissão , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Estadiamento de Neoplasias , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...