Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Hautarzt ; 72(10): 913-921, 2021 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-34529088

RESUMO

The nose has an important function in the esthetic perception of the face. The esthetic coverage of defects on the nose is therefore of particular importance; however, the position is exposed to sunlight and poses a particular risk for the development of non-melanoma skin cancer (NMSC) and melanomas. After tumor excision, the size of the defect is decisive for defect closure. In addition, multilayer defects in which the cartilage or mucous membranes must be reconstructed by plastic surgery, represent a particular challenge for the surgeon. There are various options for reconstruction depending on the extent of the defects on the nose. This article gives an overview of the paramedian forehead flap, the indications and implementation.


Assuntos
Neoplasias Nasais , Rinoplastia , Testa/cirurgia , Humanos , Nariz/cirurgia , Neoplasias Nasais/cirurgia , Retalhos Cirúrgicos
6.
Hautarzt ; 71(9): 715-723, 2020 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-32827047

RESUMO

Leg ulcers pose a therapeutic challenge due to a chronic healing process. Conservative wound dressings are initially the treatment of choice, but their effectiveness in therapy-refractory wounds is limited. In these cases, multiple mechanical debridement in combination with split-thickness skin grafts (STSG) are a simple and safe treatment option for ulcer coverage. Additional therapy with negative pressure wound therapy (NPWT) improves the surgical outcome by promoting ulcer granulation, continuous elimination of exsudate and blood as well as increased contact pressure on the skin graft. After transplantation, the split skin graft requires daily wound dressings until it has fully healed after approximately 3 weeks.


Assuntos
Desbridamento , Úlcera da Perna/terapia , Tratamento de Ferimentos com Pressão Negativa , Transplante de Pele , Humanos , Resultado do Tratamento , Cicatrização
7.
Surg J (N Y) ; 6(1): e42-e46, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32133414

RESUMO

Introduction The main postoperative complication of free flaps is perfusion compromise. Urgent intervention is critical to increase the chances of flap survival. Invasive flap perfusion monitoring with direct blood flow feedback through the Cook-Swartz Doppler probe could enable earlier detection of perfusion complications. Materials and Methods Between 2012 and 2016, 35 patients underwent breast reconstruction or defect coverage after trauma with a deep inferior epigastric perforator, anterolateral thigh, transverse musculocutaneous gracilis, gracilis, or latissimus dorsi flap in our department. All flaps were monitored with a Cook-Swartz probe for 10 days postoperatively. The 20 MHz probe was placed around the arterial-venous anastomosis. A flap monitoring protocol was established for standardized surveillance of postoperative perfusion. In the event of probe signal loss, immediate surgical revision was initiated. Results Signal loss was detected in 8 of the 35 cases. On return to the operating room, six were found to be true positives (relevant disruption of flap perfusion) and two were false positives (due to Doppler probe displacement). There were also two false negatives, resulting in a slowly progressive partial flap loss. Flap perfusion was restored in three of the six cases (50%) identified by the probe. Following surgical intervention, three of the six cases had persistent problems with perfusion, resulting in two total flap losses and one partial flap necrosis leading to an overall 5.7% total flap loss. Conclusion Postoperative flap perfusion surveillance is a complex matter. Surgical experience is often helpful but not always reliable. The costs, false-positive, and false-negative rates associated with invasive perfusion monitoring with Cook-Swartz probe make it most appropriate for buried flaps. Level of Evidence This is an original work.

8.
J Cardiothorac Vasc Anesth ; 30(3): 619-26, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27321789

RESUMO

OBJECTIVES: Depending on the pre-existing condition of the right ventricle (RV), left ventricular assist device (LVAD) implantation may have a detrimental effect on RV function, subsequently leading to right heart failure. This study details the authors' experience with perioperative mechanical RV support in patients with biventricular impairment but primarily scheduled for isolated LVAD implantation. DESIGN: Retrospective study. SETTING: Two center study, university hospital. PARTICIPANTS: This study included LVAD recipients with preoperative biventricular impairment who received an additional right ventricular assist device (RVAD) after a failed weaning attempt from cardiopulmonary bypass due to acute RV failure. INTERVENTIONS: Outcomes of 25 patients who underwent LVAD and unplanned temporary RVAD implantation were analyzed. MEASUREMENTS AND MAIN RESULTS: All patients experienced significant preoperative RV impairment (tricuspid annular plane systolic excursion: 10.2±26.3 mm; right atrium pressure: 17.9±10.4 mmHg) and pulmonary hypertension (pulmonary artery pressure: 54.8±25.7 mmHg). In 15 patients, additional tricuspid valve annuloplasty was performed. Mean duration of temporary RVAD support was 11.1±7.2 days. In 23 patients (92%), the RVAD was removed successfully. None of the patients developed RV failure after RVAD removal. Hospital survival and the 1-year survival rate of the study group were 68% and 56%, respectively. CONCLUSIONS: The results of perioperative RVAD support in LVAD recipients with biventricular dysfunction are encouraging. Temporary RVAD support allows an already compromised RV to become attuned to the hemodynamic conditions after LVAD implantation. This strategy provides patients with preoperative impaired RV function a high likelihood to permanently undergo LVAD support only.


Assuntos
Insuficiência Cardíaca/prevenção & controle , Coração Auxiliar , Implantação de Prótese/métodos , Adulto , Idoso , Ponte Cardiopulmonar , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória/métodos , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia
9.
Artigo em Inglês | MEDLINE | ID: mdl-26816671

RESUMO

BACKGROUND: Inguinal lymph node dissection (ILND) is associated with a high rate of morbidity. To evaluate the clinical benefit of surgical adhesives to reduce complications in patients undergoing ILND, we compared the use of TissuGlu(®) Surgical Adhesive and ARTISS(®) fibrin sealant with a control population. MATERIAL AND METHODS: We conducted a retrospective analysis of patients undergoing ILND for metastatic malignant skin tumors at one hospital, Fachklinik Hornheide (Münster, Germany), from January 2011 through September 2013, assessing 137 patients with a total of 142 procedures. RESULTS: Complications occurred in 22/60 procedures in the TissuGlu group (TG), in 8/17 in the ARTISS group (AG), and in 29/65 in the control group (CG). Prolonged drainage and seroma were recorded in 16 (26.7%), four (23.5%), and 26 (40%) respectively (non-significant). TG showed less extended drainage vs. CG (p=0.082). Mean daily drain volumes were significantly lower in AG vs. CG (p=0.000). With regard to wound infection, there was a 15% reduction in TG and 74% increase in AG group. Revision surgery was reduced by 36% in TG and increased by 54% in AG. Mean daily drain volumes were significantly lower in AG vs. CG (p=0.000). Mean total post-operative drain volume was lower in TG and AG vs. CG (p<0.001 among groups, CG vs. TG p<0.001, CG vs. AG p<0.001). The mean body mass index (BMI) was significantly higher in patients with complications, 29.4±5.8 vs. 25.3±4.1 (p=0.000). CONCLUSION: The use of TissuGlu in our ILND patients was associated with a reduction in post-operative wound related complications and the need for revision surgeries compared to the control group. Daily drainage was significantly lower within the first 7 post-operative days with the use of ARTISS, but the benefit was lost due to the higher occurrence of wound infection and revision surgery. BMI above 29 is a risk factor for complications following ILND. ( LEVEL OF EVIDENCE: level IV, retrospective case study).

10.
Heart Vessels ; 31(3): 390-6, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25491933

RESUMO

We report on our experience with a simplified elephant trunk (ET) procedure with a multi-branched prosthesis (Vascutek(®) Siena™ Collared Graft). It consists of a proximal portion (20 cm) with prefabricated side branches, a collar and a distal portion (30 cm). The collar, which can be trimmed into any desired diameter, constitutes the suture portion to the descending aorta. Radiopaque markers in the distal portion indicate the landing zone. Between January 2011 and June 2013, 20 consecutive patients (10 women; mean age, 66 ± 9.3 years) underwent ET procedure, including 6 re-do cases. Underlying aortic diseases were acute dissection (n = 6), chronic dissection (n = 4), aneurysm (n = 8) and PAU (n = 2). Mean preoperative diameter of the descending aorta was 49.1 ± 12.9 mm (range 74.7-29.7 mm). Concomitant procedures included ascending aortic replacement in 16 patients; root replacement in 2; AVR in 2, CABG in 3 and mitral repair in 1 patient. CPB time was 263 ± 94 min; mean duration of ACP was 65 ± 14 min. Two patients died on POD 8 and 78, respectively. Major adverse events included stroke (n = 1), resternotomy for bleeding (n = 2), renal failure requiring temporary dialysis (n = 1) and recurrent nerve paresis (n = 2). After a mean follow-up of 10 ± 8 months, all discharged patients were alive. Seven patients underwent stent-graft implantation of the descending aorta and one patient underwent open descending aortic replacement. The last generation of multi-branched arch prosthesis and especially the Vascutek(®) Siena™ Collared Graft make ET procedure a reasonable treatment option even in patients with acute aortic dissection.


Assuntos
Aorta Torácica/cirurgia , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Doença Aguda , Idoso , Dissecção Aórtica/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Doença Crônica , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Reoperação , Fatores de Tempo , Resultado do Tratamento
11.
Artif Organs ; 38(5): 383-90, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24117675

RESUMO

Reports on third-generation centrifugal intrapericardial pumps (HeartWare International, Inc., Framingham, MA, USA) have shown better survival results than the previous-generation devices. However, outcomes depending on the preoperative level of stability can substantially differ, resulting in a limited analysis of potentialities and drawbacks of a given device. In the present study we sought to compare in our single-center experience the survival results of this third-generation device with previous left ventricular systems taking into account the different preoperative Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) levels. Between February 1993 and March 2012, 287 patients underwent assist device implantation in our university hospital (INTERMACS Level 1-2 = 158 patients; INTERMACS Level 3-4-5 = 129 patients). Assist devices implanted were: Group A (HVAD HeartWare, n = 52), group B (previous continuous-flow ventricular assist device [VAD], InCor [Berlin Heart, Berlin, Germany], n = 37; VentrAssist [VentraCor, Inc., Chatswood, NSW, Australia], n = 7; DeBakey [MicroMed Cardiovascular, Inc., Houston, TX, USA], n = 32), and group C (pulsatile systems, n = 159). After cumulative support duration of 54 436 days and a mean follow-up of 6.21 ± 7.46 months (range 0-45.21 months), log-rank analysis revealed a survival for group A of 82.0%, 70.4%, and 70.4%; for group B of 84.0%, 48.2%, 33.7%; and for group C of 71.6%, 46.1%, 33.8%, at 1, 12, and 24 months respectively, with a significantly (P = 0.013) better outcome for group A. When stratifying the survival on the basis of INTERMACS level, no significant survival improvement was observed among all patients who underwent VAD implantation in INTERMACS 1-2 (P = 0.47). However, among patients who underwent elective VAD implantation (INTERMACS 3-4-5), group A had a significantly better outcome (P = 0.005) compared with the other INTERMACS-matched groups (B,C) with a survival rate of 88.8% in group A versus 34.2% in group B and 45.6% in group C at 24 months, respectively. Elective HVAD system implantation shows improved survival benefit over the other INTERMACS-matched devices. Moreover, preoperative unstable hemodynamics resulted in a poor prognosis independently from the pump generation.


Assuntos
Cardiopatias/cirurgia , Ventrículos do Coração/cirurgia , Coração Auxiliar , Adulto , Idoso , Feminino , Seguimentos , Cardiopatias/terapia , Coração Auxiliar/efeitos adversos , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Análise de Sobrevida , Resultado do Tratamento , Adulto Jovem
13.
Interact Cardiovasc Thorac Surg ; 16(2): 112-5, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23159508

RESUMO

OBJECTIVES: The Trifecta valve (St. Jude Medical) was introduced into clinical practice as a tri-leaflet stented pericardial valve designed for supra-annular placement in the aortic position. The present study aims to evaluate the preliminary results with this new bioprosthesis. METHODS: Seventy patients underwent aortic valve replacement (AVR) with the Trifecta valve between August 2010 and December 2011. Thirty-three patients were male and 37 were female (52.9%). Mean age was 74.65 ± 7.63 (range 47-90 years). Prevalent cause of AVR was aortic stenosis in 64 (91.43%) patients. The mean preoperative pressure gradient was 50 ± 17 (range 20-84 mmHg), and the mean aortic valve area was 0.77 ± 0.33. Five (7.14%) patients were operated on due to aortic valve endocarditis. One patient was operated on due to isolated, severe aortic insufficiency. All patients were in New York Heart Association functional class III or IV. Twenty-eight (40%) patients underwent concomitant procedures. RESULTS: Concomitant procedures were coronary artery bypass grafting (n = 25), mitral valve replacement (n = 1), ablation of atrial fibrillation (n = 1) and septal myomectomy (n = 1). There were no intraoperative deaths. The 30-day in-hospital mortality was 2.85% (2 of 70). One late death occurred during the in-hospital stay due to a multiorgan failure on postoperative day 60. There were 2 (2.85%) perioperative strokes. Mean pressure gradient decreased significantly from a preoperative value of 50 ± 17 mmHg to an intraoperative gradient of 9 ± 4 mmHg (Table 3). The mean gradients were 14, 11, 11, 8 and 6 mmHg for the 19, 21, 23, 25 and 27 mm valve size, respectively. No prosthesis dislocation, endocarditis, valve thrombosis or relevant aortic regurgitation was observed at discharge. CONCLUSIONS: The initial experience with the Trifecta valve bioprosthesis shows excellent outcomes with favourable early haemodynamics. Further studies with longer follow-up are needed to confirm those preliminary results.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Alemanha , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
14.
Ann Thorac Surg ; 95(1): 170-7, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23141906

RESUMO

BACKGROUND: The HeartWare ventricular assist device (HVAD) system (HeartWare International Inc, Framingham, MA) is a new centrifugal continuous-flow ventricular assist device. The aim of the present study is to review our institutional experience with this novel device. METHODS: We reviewed the files of 50 patients (39 men, 11 women) with a mean age of 50.6 ± 11.8 years (range, 19 to 70 years) who underwent HVAD implantation between July 2009 and November 2011. Two patients underwent HeartWare BIVAD implantation. The underlying heart diseases were end-stage ischemic heart disease (n = 12), acute myocardial infarction (n = 9), dilated cardiomyopathy (n = 27) and acute myocarditis (n = 2). Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profiles were level 1 (n = 11), 2 (n = 5), 3 (n = 10), and 4 (n = 24). RESULTS: After a cumulative support duration of 11,086 days, Kaplan-Meier analysis revealed a survival of 82.0%, 77.9%, 75.5%, at 1, 12, and 24 months, respectively. Causes of early death were right heart failure (n = 4), multiorgan failure (n = 2), septic shock (n = 2), and major neurologic complications (n = 4). One late death occurred due to a right heart failure. Comparison between patients operated on in cardiogenic shock (INTERMACS 1 and 2) and patients who underwent elective HVAD implantation (INTERMACS 3 and 4) revealed a survival of 61.5% and 44.1% for the INTERMACS 1 and 2 group and 90.3% and 87.1% for the INTERMACS 3 and 4 group at 1 and 12 months, respectively (odds ratio, 4.67; p = 0.003). One patient was weaned from the system after 2 years. Eleven patients (22%) were successfully bridged to transplantation. Mean time to transplantation was 209 days (range, 72 to 427 days). Posttransplant survival at the 1-year follow-up was 90.9% (11 patients). CONCLUSIONS: Our experience with HVAD shows satisfying results with an excellent posttransplantation survival. Moreover, the stratified survival based on the level of preoperative stability shows better outcomes in patients undergoing elective HVAD implantation.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Sistema de Registros , Adulto , Idoso , Feminino , Seguimentos , Alemanha/epidemiologia , Insuficiência Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA