Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 32(1): 104-15, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26520485

RESUMO

PURPOSE: Based on the guidelines from "Report 87: Radiation Dose and Image-quality Assessment in Computed Tomography" of the International Commission on Radiation Units and Measurements (ICRU), a software framework for automated quantitative image quality analysis was developed and its usability for a variety of scientific questions demonstrated. METHODS: The extendable framework currently implements the calculation of the recommended Fourier image quality (IQ) metrics modulation transfer function (MTF) and noise-power spectrum (NPS), and additional IQ quantities such as noise magnitude, CT number accuracy, uniformity across the field-of-view, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of simulated lesions for a commercially available cone-beam phantom. Sample image data were acquired with different scan and reconstruction settings on CT systems from different manufacturers. RESULTS: Spatial resolution is analyzed in terms of edge-spread function, line-spread-function, and MTF. 3D NPS is calculated according to ICRU Report 87, and condensed to 2D and radially averaged 1D representations. Noise magnitude, CT numbers, and uniformity of these quantities are assessed on large samples of ROIs. Low-contrast resolution (CNR, SNR) is quantitatively evaluated as a function of lesion contrast and diameter. Simultaneous automated processing of several image datasets allows for straightforward comparative assessment. CONCLUSIONS: The presented framework enables systematic, reproducible, automated and time-efficient quantitative IQ analysis. Consistent application of the ICRU guidelines facilitates standardization of quantitative assessment not only for routine quality assurance, but for a number of research questions, e.g. the comparison of different scanner models or acquisition protocols, and the evaluation of new technology or reconstruction methods.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Automação , Meios de Contraste/química , Processamento Eletrônico de Dados , Análise de Fourier , Humanos , Imageamento Tridimensional , Modelos Estatísticos , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Razão Sinal-Ruído , Software , Tomografia Computadorizada por Raios X/normas
2.
Eur J Radiol ; 80(2): 274-8, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20667676

RESUMO

OBJECTIVES: To evaluate characteristic imaging findings of tumor attenuation in multiphase computed tomography (CT) between renal oncocytomas and clear-cell renal cell carcinoma (ccRCC) of small tumor size (≤5 cm). METHODS: We retrospectively identified 20 patients with complete four-phase CT with either histologically confirmed small renal oncocytoma (N=10) or ccRCC (N=10) who underwent subsequent total or partial nephrectomy. Exclusion criteria for RCC were non-clear-cell components in histology and a tumor diameter>5 cm. The relative attenuation of solid renal lesions and normal renal cortex was determined in the unenhanced, corticomedullary, nephrographic and excretory phase. Statistical comparison was carried out by Wilcoxon Rank Sum Test. RESULTS: Mean tumor size of renal oncocytomas was 2.8±0.4 cm (1.2-5) and of ccRCC 2.5±0.2 cm (1.7-4.4; p=0.57). All lesions were homogenous without extended areas of necroses. In the nephrographic phase, the difference of attenuation between renal cortex and tumor lesion was highest in both entities (oncocytoma, 48.1±5.2 HU; ccRCC, 67.5±12.1) but not between entities (p=0.30). In the corticomedullary phase, renal oncocytomas showed greater isodensity to the normal renal cortex (13.9±4.3 HU) compared to clear-cell RCC (51.5±5.0 HU; p=0.003). No further significant differences were found for the unenhanced and excretory phase. CONCLUSIONS: In this study, the maximum tumor-to-kidney contrast coincided with the nephrographic phase which was thus the most reliable for the detection of a renal lesion<5 cm. For lesion characterization, the corticomedullary phase was most useful for differentiating both entities. This finding is particularly important for the preoperative planning of a partial nephrectomy.


Assuntos
Adenoma Oxífilo/diagnóstico por imagem , Carcinoma de Células Renais/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adenoma Oxífilo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/cirurgia , Diagnóstico Diferencial , Feminino , Humanos , Iohexol/análogos & derivados , Iopamidol/análogos & derivados , Neoplasias Renais/cirurgia , Masculino , Pessoa de Meia-Idade , Nefrectomia , Estatísticas não Paramétricas
3.
J Neurol Neurosurg Psychiatry ; 81(3): 339-43, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19687022

RESUMO

BACKGROUND: Postural orthostatic tachycardia syndrome (POTS) is a disorder of orthostatic intolerance characterised by excessive tachycardia of unknown aetiology. Whether this condition involves abnormal cardiac sympathetic innervation or function remains elusive. Meta-iodobenzylguanidine (MIBG) resembles guanethidine and is a pharmacologically inactive analogue of norepinephrine, which is similarly metabolised in noradrenergic neurons. MIBG myocardial scintigraphy is used clinically to estimate local myocardial sympathetic nerve damage in some forms of heart disease and autonomic neuropathy. The objective of this study was to evaluate cardiac sympathetic innervation in patients with POTS. METHODS: 20 patients with POTS were studied using (123)I-MIBG-single photon emission computed tomography, standardised autonomic testing, assessment of catecholamine plasma levels and sympathetic skin response. RESULTS: In four POTS patients (20.0%), myocardial MIBG uptake was markedly decreased. The mean heart to mediastinum ratio was reduced to 1.22+/-0.08 compared with the normal range of >1.7. No correlation was found between myocardial MIBG uptake and degree of postural tachycardia, baroreflex sensitivity, catecholamine plasma levels or other autonomic parameters. Sympathetic skin responses were normal in all patients. CONCLUSIONS: These findings suggest that POTS may be, in part, a manifestation of autonomic cardiac neuropathy. MIBG myocardial scintigraphy may be helpful to distinguish patients with neuropathic POTS from patients with orthostatic intolerance of other origin.


Assuntos
3-Iodobenzilguanidina , Doenças do Sistema Nervoso Autônomo/fisiopatologia , Coração/inervação , Síndrome da Taquicardia Postural Ortostática/diagnóstico por imagem , Síndrome da Taquicardia Postural Ortostática/fisiopatologia , Compostos Radiofarmacêuticos , Sistema Nervoso Simpático/fisiopatologia , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Doenças do Sistema Nervoso Autônomo/diagnóstico por imagem , Pressão Sanguínea/fisiologia , Diagnóstico Diferencial , Eletrocardiografia , Feminino , Análise de Fourier , Resposta Galvânica da Pele/fisiologia , Frequência Cardíaca/fisiologia , Humanos , Masculino , Norepinefrina/sangue , Valores de Referência , Processamento de Sinais Assistido por Computador
4.
Clin Auton Res ; 18(1): 40-2, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17898925

RESUMO

Myocardial 123I-Meta-iodobenzylguanidine uptake was markedly reduced in a patient with postural tachycardia syndrome (POTS). This finding suggests that loss of sympathetic autonomic neurons in the heart may play a role in the etiology of POTS.


Assuntos
Doenças do Sistema Nervoso Autônomo/complicações , Coração/inervação , Postura , Taquicardia/etiologia , Adulto , Doenças do Sistema Nervoso Autônomo/diagnóstico , Doenças do Sistema Nervoso Autônomo/fisiopatologia , Feminino , Coração/efeitos dos fármacos , Humanos , Síndrome , Taquicardia/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...