1.
Int J Antimicrob Agents ; 46(4): 456-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26260191

RESUMO

Recent studies offer contradictory findings about the role of multidrug efflux pumps in bacterial biofilm development. Thus, the aim of this study was to investigate the involvement of the AcrAB efflux pump in biofilm formation by investigating the ability of AcrB and AcrAB null mutants of Salmonella enterica serovar Typhimurium to produce biofilms. Three models were used to compare the ability of S. Typhimurium wild-type and its mutants to form biofilms: formation of biofilm on polystyrene surfaces; production of biofilm (mat model) on the air/liquid interface; and expression of curli and cellulose on Congo red-supplemented agar plates. All three investigated genotypes formed biofilms with similar characteristics. However, upon exposure to chloramphenicol, formation of biofilms on solid surfaces as well as the production of curli were either reduced or were delayed more significantly in both mutants, whilst there was no visible effect on pellicle formation. It can be concluded that when no selective pressure is applied, S. Typhimurium is able to produce biofilms even when the AcrAB efflux pumps are inactivated, implying that the use of efflux pump inhibitors to prevent biofilm formation is not a general solution and that combined treatments might be more efficient. Other factors that affect the ability to produce biofilms depending on efflux pump activity are yet to be identified.


Assuntos
Proteínas de Bactérias/genética , Biofilmes/crescimento & desenvolvimento , Proteínas de Transporte/genética , Deleção de Genes , Salmonella typhimurium/genética , Salmonella typhimurium/fisiologia , Proteínas de Bactérias/metabolismo , Celulose/metabolismo , Meios de Cultura/química , Microbiologia Ambiental , Poliestirenos , Salmonella typhimurium/crescimento & desenvolvimento
2.
Food Microbiol ; 35(1): 65-72, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23628616

RESUMO

Bacterial colonization and biofilm formation on stainless steel (SS) surfaces can be sources for cross contamination in food processing facilities, possessing a great threat to public health and food quality. Here the aim was to demonstrate the influence of surface finish of AISI 316 SS on colonization, biofilm formation and susceptibility of Salmonella Typhimurium to disinfection. Initial attachment of S. Typhimurium on surfaces of SS was four times lower, when surface was polished by Bright-Alum (BA) or Electropolishing (EP), as compared to Mechanical Sanded (MS) or the untreated surface (NT). The correlation between roughness and initial bacterial attachment couldn't account on its own to explain differences seen. Biofilms with similar thickness (15-18 µm) were developed on all surfaces 1-day post inoculation, whereas EP was the least covered surface (23%). Following 5-days, biofilm thickness was lowest on EP and MS (30 µm) and highest on NT (62 µm) surfaces. An analysis of surface composition suggested a link between surface chemistry and biofilm development, where the higher concentrations of metal ions in EP and MS surfaces correlated with limited biofilm formation. Interestingly, disinfection of biofilms with chlorine was up to 130 times more effective on the EP surface (0.005% surviving) than on the other surfaces. Overall these results suggest that surface finish should be considered carefully in a food processing plant.


Assuntos
Biofilmes/crescimento & desenvolvimento , Cloro/farmacologia , Salmonella typhimurium/efeitos dos fármacos , Salmonella typhimurium/isolamento & purificação , Aço Inoxidável/análise , Biofilmes/efeitos dos fármacos , Qualidade de Produtos para o Consumidor , Desinfecção , Farmacorresistência Bacteriana/efeitos dos fármacos , Contaminação de Equipamentos , Contaminação de Alimentos/análise , Microbiologia de Alimentos , Indústria de Processamento de Alimentos , Microscopia de Força Atômica , Espectroscopia Fotoeletrônica , Salmonella typhimurium/crescimento & desenvolvimento , Propriedades de Superfície
3.
Int J Food Microbiol ; 160(3): 219-26, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23290228

RESUMO

The consumer demand for fresh tasting, high quality, low salt, preservative-free meals which require minimal preparation time magnifies the safety concern and emphasizes the need to use innovative technologies for food processing. A modern technique to uniformly heat and cook foods is based on a combination of convection and controlled radio frequency (RF) energy. However any advantage conferred on meat cooked by this method would be lost if application of the technology results in decreased safety. Our main goal was to study the inactivation efficacy of this method of cooking against pathogens in ground meat in comparison to standard convection cooking. Meat balls were artificially inoculated with GFP expressing Escherichia coli, Salmonella Typhimurium and Listeria monocytogenes as well as spores of Bacillus cereus and Bacillus thuringiensis and cooked by convection heating (220°C, 40 min), by using energy generated from frequencies in the RF bandwidth (RF cooking, 7.5 min) or by combined heating (5.5 min), until the center temperature of each sample reached 73°C. The mean reductions in total indigenous bacteria obtained by RF and convection were 2.8 and 2.5 log CFU/g, respectively. Cooking of meat balls with convection reduced the E. coli population (8 log CFU/g) by 5.5 log CFU/g, whilst treatment with RF reduced E. coli population to undetectable levels. The mean reductions of S. Typhimurium obtained by RF and convection were 5.7 and 6.5 log CFU/g, respectively. The combined treatment reduced the Salmonella population to undetectable levels. In contrast, L. monocytogenes was poorly affected by RF cooking. The mean reduction of L. monocytogenes obtained by RF energy was 0.4 log CFU/g, while convection cooking resulted in undetectable levels. Interestingly, the combined treatment also resulted with undetectable levels of Listeria although time of cooking was reduced by 86%. One-step cooking had negligible effects on the Bacillus spores and therefore a 2-step treatment of RF or convection was applied. This 2-step treatment proved to be efficient with 4.5 log CFU/g reduction for both RF and convection. In conclusion, here we show that combination of RF with convection cooking resulted in similar or even better effects on selected foodborne pathogens compared to convection only, while the time required for safe cooking is cut down by up to 86%. The equal or better results in the levels of all investigated pathogens using RF with convection compared with convection only suggest that this technology looks promising and safe for ground beef cooking.


Assuntos
Bactérias/efeitos da radiação , Culinária/métodos , Microbiologia de Alimentos , Carne/microbiologia , Viabilidade Microbiana/efeitos da radiação , Ondas de Rádio , Animais , Bovinos , Contagem de Colônia Microbiana , Qualidade de Produtos para o Consumidor , Culinária/normas , Temperatura Alta , Fatores de Tempo