Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 16(3): e55634, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38586798

RESUMO

Although the specific relationship between concussion and the autonomic nervous system (ANS) has not been fully elucidated, it is generally understood that the pathologic response after a traumatic brain injury (TBI) is linked with systolic cardiac dysfunction. In this case, we present a patient with multiple concussion injuries over a five-year period who exhibited severe cardiac and autonomic dysfunction, in addition to prolonged impairments in vestibular function, oculomotor function, cognitive function, and headaches. The patient is a 28-year-old male with a past medical history of multiple concussions, with the first concussion occurring due to a skiing accident in January 2015. He initially presented in October 2016 after sustaining a concussion due to a motor vehicle accident (MVA) without loss of consciousness (LOC) two weeks prior. In July 2017, the patient was involved in another MVA with a positive head strike and without LOC, causing his third concussion. After each of his first three concussions, he displayed various symptoms that eventually resolved. In October 2020, the patient suffered a syncopal ground-level fall with several minutes of LOC due to dehydration and lightheadedness, leading to his fourth concussion. His fourth concussion resulted in chronic autonomic dysfunction with resting tachycardia refractory to medical management, and he eventually underwent a cardiac ablation. Although the patient underwent a cardiac ablation, his tachycardia and dysautonomia still cause dysfunction in his daily life. With millions of people living with the sequelae of TBI, the recognition and treatment of autonomic dysfunction should be a continued focus in brain injury research.

2.
Injury ; 54(2): 584-588, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36400631

RESUMO

BACKGROUND: To determine if the use of a narrower elastic tourniquet compared to a standard pneumatic tourniquet reduces operative blood loss in the operative fixation of humeral shaft fractures. METHODS: This retrospective cohort study was performed at a level I trauma center and included 134 patients, aged 18 to 90 years, with a humeral shaft fracture treated with open reduction internal fixation (ORIF) from January 2007 through June 2018. The primary variable of interest was the application of a HemaClear™ elastic tourniquet versus a standard pneumatic tourniquet during the fixation of a humeral shaft fracture. The primary outcome was estimated blood loss (EBL) during the humerus ORIF surgery as recorded in the operative record. The secondary outcomes were total tourniquet time and operative time. The primary purpose of the study was to compare the above outcomes between the two tourniquet types. RESULTS: Estimated blood loss was 42% lower (95% CI: 11% to 73%, p < 0.01) in the elastic tourniquet group when compared to the standard pneumatic tourniquet group. The use of the elastic tourniquet was also associated with a 67% increase (95% CI: 35% to 100%, p < 0.01) in tourniquet time compared to the standard pneumatic tourniquet. No difference in the total operative time between the two groups (difference, -3%; 95% CI: -21 to 14, p = 0.72) was observed. CONCLUSION: Elastic tourniquet use was associated with 42% less blood loss in the fixation of humeral shaft fractures compared to use of a traditional pneumatic tourniquet, although this may be of unclear clinical importance given the relatively low estimated blood loss in this cohort. The potential benefit of reduced blood loss associated with the narrower elastic tourniquet is likely caused by the increased tourniquet time, without a change in overall operative time.


Assuntos
Fixação Interna de Fraturas , Fraturas do Úmero , Humanos , Estudos Retrospectivos , Torniquetes , Fraturas do Úmero/cirurgia , Úmero/cirurgia , Resultado do Tratamento
3.
Cureus ; 14(6): e25719, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35812628

RESUMO

Guillain-Barré syndrome (GBS) is a rare autoimmune disorder that presents with neurological symptoms that can mimic other conditions. This mimicry can hide other important neurological diagnoses. Here, we present a rare case of thoracic myelopathy secondary to a sequestered dorsal epidural herniated disc fragment that initially presented with the classic findings of GBS. A 58-year-old female presented with progressing bilateral lower extremity weakness, paresthesias, and absent bilateral lower extremity deep tendon reflexes. Lumbar magnetic resonance imaging (MRI) findings were disproportionate to presentation, and lumbar puncture fluid analysis revealed clear, colorless fluid with albuminocytological dissociation. The patient was diagnosed with GBS and treated with a short course of intravenous steroids followed by intravenous immunoglobulin. The patient later developed new-onset ulnar distribution paresthesias, lower extremity spasticity, constipation, and urinary retention that caused a decline in functional progress. Further investigation prompted evaluation with cervical and thoracic MRIs, which revealed a left dorsal epidural lesion at the T9-T10 level causing severe cord compression. The patient was definitively treated with a T9-T10 laminectomy and excision of the offending lesion. Pathology revealed collagenous tissue with fibroblastic proliferation, consistent with a sequestered fragment of the herniated intervertebral disc. The patient was further treated with both acute and subacute rehabilitation. She was eventually discharged home and was able to ambulate independently with a walker. Dependency on positive albuminocytological dissociation in cases of potential GBS can lead to errors in diagnostic accuracy and delay appropriate treatment. Clinicians should remain mindful that GBS is a diagnosis of exclusion and MRI of the entire spine should be considered when the diagnosis of GBS is uncertain.

4.
Injury ; 52(6): 1351-1355, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33863501

RESUMO

OBJECTIVE: Infection after fracture fixation is a potentially devastating outcome, and surgical management is frequently unsuccessful at clearing these infections. The purpose of this study is to determine if factors can be identified that are associated with treatment failure after operative management of a deep surgical site infection. METHODS: We retrospectively reviewed the billing system at a Level I trauma center between March 2006 and December 2015. We identified 451 patients treated for deep surgical site infection after fracture fixation at our center. A multivariate regression analysis was then performed to evaluate for factors associated with treatment failure. RESULTS: Mean follow-up was 2.3 years. One hundred fifty-six patients (35%) failed initial surgical management. Risk factors associated with treatment failure included initial culture results positive for polymicrobial organisms (odds ratio [OR], 1.6; 95% confidence interval [CI], 1.0-2.4), removal of implants (OR, 1.9; 95% CI, 1.2-2.9), or Gustilo-Anderson IIIB/IIIC injury (OR, 2.0; 95% CI, 1.1-3.7). Increased body mass index and fulfilling the criteria to have a methicillin-resistant Staphylococcus aureus (MRSA) nasal swab screening showed a trend toward increased risk of failure. CONCLUSION: Treatment failure after deep surgical site infection was relatively common. Three distinct factors (polymicrobial infection, removal of implants, and IIIB/C fracture) were associated with failure to eradicate the infection in the first series of surgeries and antibiotics. These data might help guide clinicians as they counsel patients on the risk of treatment failure and might focus efforts to improve treatment toward patients at higher risk of treatment failure.


Assuntos
Fraturas Expostas , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Fixação Interna de Fraturas , Fraturas Expostas/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Infecções Estafilocócicas/tratamento farmacológico , Infecção da Ferida Cirúrgica/epidemiologia , Falha de Tratamento , Resultado do Tratamento
5.
Clin Orthop Relat Res ; 479(8): 1793-1801, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33760776

RESUMO

BACKGROUND: Gunshot injuries of the extremities are common in the United States, especially among people with nonfatal gunshot wounds. Controversy persists regarding the proper management for low-energy gunshot-induced fractures, likely stemming from varying reports on the likelihood of complications. There has yet to be published a study on a large cohort of patients with gunshot-induced tibia fractures on which to base our understanding of complications after this injury. QUESTIONS/PURPOSES: (1) What percentage of patients with low-energy gunshot-induced tibia fractures developed complications? (2) Was there an association between deep infection and fracture location, injury characteristics, debridement practices, or antibiotic use? METHODS: This was a multicenter retrospective study. Between January 2009 and December 2018, we saw 201 patients aged 16 years or older with a gunshot-induced fracture who underwent operative treatment; 2% (4 of 201) of those screened had inadequate clinical records, and 38% (76 of 201) of those screened had inadequate follow-up for inclusion. In all, 121 patients with more than 90 days of follow-up were included in the study. Nonunion was defined as a painful fracture with inadequate healing (fewer than three cortices of bridging bone) at 6 months after injury, resulting in revision surgery to achieve union. Deep infection was defined according to the confirmatory criteria of the Fracture-Related Infection Consensus Group. These results were assessed by a fellowship-trained orthopaedic trauma surgeon involved with the study. Complication proportions were tabulated. A Kaplan-Meier chart demonstrated presentations of deep infection by fracture location (proximal, shaft, or distal). Univariate statistics and multivariate Cox regression were used to examine the association between deep infection and fracture location, entry wound size, vascular injury, intravenous (IV) antibiotics in the emergency department (ED), deep and superficial debridement, the duration of postoperative IV antibiotics, and the use of topical antibiotics, while adjusting for age, race/ethnicity, smoking status, and BMI. A power analysis for the result of deep infection demonstrated that we would have had to observe a hazard ratio of 4.28 or greater for shaft versus proximal locations to detect statistically significant results at 80% power and alpha = 0.05. RESULTS: The overall complication proportion was 49% (59 of 121), with proportions of 14% (17 of 121) for infection, 27% (33 of 121) for wound complications, 20% (24 of 121) for nonunion, 9% (11 of 121) for hardware breakage, and 26% (31 of 121) for revision surgery. A positive association was present between deep infection and deep debridement (HR 5.51 [95% confidence interval 1.12 to 27.9]; p = 0.04). With the numbers available, we found no association between deep infection and fracture location, entry wound size, vascular injury, IV antibiotics in the ED, superficial debridement, the duration of postoperative IV antibiotics, and the use of topical antibiotics. CONCLUSION: In this multicenter study, we found a higher risk of complications in operative gunshot-induced tibia fractures than prior studies have reported. Infection, in particular, was much more common than expected based on prior studies. Consequently, surgeons might consider adopting the general management principles for nongunshot-induced open tibia fractures with gunshot-induced fractures, such as the use of IV antibiotics both initially and after surgery. Further research is needed to test and validate these approaches. LEVEL OF EVIDENCE: Level IV, therapeutic study.


Assuntos
Fixação de Fratura/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Fraturas da Tíbia/cirurgia , Ferimentos por Arma de Fogo/cirurgia , Adolescente , Adulto , Desbridamento/estatística & dados numéricos , Feminino , Fixação de Fratura/métodos , Consolidação da Fratura , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fraturas da Tíbia/etiologia , Resultado do Tratamento , Ferimentos por Arma de Fogo/complicações , Adulto Jovem
6.
J Orthop Trauma ; 35(1): e18-e24, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-32833697

RESUMO

OBJECTIVE: To determine whether fully threaded transiliac-transsacral (TI-TS) fixation is biomechanically superior to partially threaded TI-TS fixation of vertically unstable transforaminal sacral fractures. METHODS: Vertically unstable zone 2 sacral fractures were created in 20 human cadaveric pelves with a unilateral osteotomy and resection of 1 cm of bone through the foramen of the sacrum to represent comminution. Ten specimens received either 2 7.3-mm fully threaded or 2 7.3-mm partially threaded TI-TS screw fixation at the S1 and S2 body, and every specimen received standard 3.5-mm 8-hole parasymphyseal plating anteriorly. Each pelvis was loaded to 250 N at 3 Hz for 100,000 cycles and then loaded to failure. The primary outcome was fracture displacement at the S1 foramen, which was measured at 25,000, 50,000, 75,000, and 100,000 cycles. Secondary outcomes were simulated clinical failure of ≥1 cm displacement at the S1 foramen to determine occurrence probability of failure, and load at failure was defined as 2.5 cm of the linear loading system displacement. Specimens in the fully threaded and partially threaded cohorts were otherwise respectively comparable in regards to age, gender, and bone density. RESULTS: Five of the 10 TI-TS partially threaded specimens experienced simulated clinical failure with >1 cm displacement at the S1 foramen compared with 0 of the 10 TI-TS fully threaded cohort (50% vs. 0%, P = 0.03). The mean maximal displacement at the S1 foramen was greater in the partially threaded cohort (9.3 mm) compared with the fully threaded cohort (3.6 mm; P = 0.004). Fully threaded specimens also demonstrated greater mean force to failure than the partially threaded specimens (461 N vs. 288 N; P = 0.0001). CONCLUSIONS: Fully threaded TI-TS screw fixation seems to be mechanically superior to partially threaded fixation in a cadaveric vertically unstable transforaminal sacral fracture model with significantly less displacement of the posterior pelvic ring and greater load to failure.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Fixação Interna de Fraturas , Fraturas Ósseas/cirurgia , Humanos , Ossos Pélvicos/cirurgia , Sacro/cirurgia
7.
J Orthop Trauma ; 35(2): 100-105, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32658018

RESUMO

OBJECTIVES: To determine the association between displaced femoral shaft bone fragments ("spikes") seen on radiographs after intramedullary nail insertion and the need for future motion surgery. DESIGN: Retrospective case-control study. SETTING: Academic trauma center. PATIENTS: We included patients with femoral shaft fractures treated with intramedullary nail insertion. Case patients (n = 22) had developed knee stiffness treated with motion surgery. The control group was a randomly selected sample (1:3 ratio). MAIN OUTCOME MEASURES: Motion surgery to address knee stiffness. We defined a "spike distance ratio" and "spike area ratio" from initial postoperative anteroposterior and lateral radiographs. Multivariable logistic regression determined the effect of spike distance and area ratios on the likelihood of need for motion surgery, controlling for polytraumatic injuries and bilateral fractures. RESULTS: The case group had a median femoral spike distance ratio of 1.9 [interquartile range (IQR), 1.6-2.5] compared with 1.5 (IQR, 1.2-1.8) in the control group. An increased femoral spike distance ratio was associated with increased odds of motion surgery (P < 0.01). A femoral spike distance >2 times the femoral radius had 32 times the odds (95% confidence interval, 2-752) of motion surgery compared with patients with distance ratios <1.25. Median femoral spike area ratios were similar between the case (0.2; IQR, 0.1-0.5) and control (0.2; IQR, 0.0-0.5) groups and were not associated with increased odds of motion surgery (P = 0.34). CONCLUSIONS: A larger spike distance ratio is associated with increased odds of subsequent motion surgery. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fraturas do Fêmur , Fixação Intramedular de Fraturas , Pinos Ortopédicos , Estudos de Casos e Controles , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
8.
Injury ; 51(7): 1662-1668, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32434717

RESUMO

INTRODUCTION: We assessed the outcome and safety of posterior plating of distal tibial fractures. METHODS: We conducted a retrospective case series at a Level I trauma center. Seventy-four consecutive patients with distal tibial fractures treated with anatomically contoured 3.5-mm T-shaped locking compression plate using a posterolateral approach from January 2008 through April 2018 were included in the study. The mean patient age was 48 years (range, 18-87 years). Fifty-nine percent of the patients were male patients, 47% of the fractures were open fractures; and 27% of the patients had multiple traumatic injuries. Eleven fractures were AO/OTA type 42, 22 were type 43A, and 41 were type 43C. Sixty-two (84%) patients were treated with initial spanning external fixation (median time, 23 days) and staged open reduction and internal fixation. The main outcome measure was unplanned reoperation to address implant failure, nonunion, deep surgical site infection, or symptomatic implant. RESULTS: Overall risk of unplanned reoperation was 15% (11 of 74 patients, 95% confidence interval, 9%-25%). Four (5%) reoperations were for nonunion, three (4%) were for surgical site infection, two (3%) were for infected nonunion, and two (3%) were for implant prominence. Loss of alignment >10 degrees occurred in one patient who underwent unplanned reoperation for nonunion. No plate breakage occurred. Median time to reoperation was 221 days (range, 22-436 days). Only one other complication was noted: wound dehiscence associated with the posterolateral approach, which was treated with irrigation and débridement and a 6-week regimen of oral antibiotics. CONCLUSIONS: Use of a posterolateral approach with a pre-contoured locking compression T-plate for the treatment of distal tibial fractures led to reasonable outcomes with an acceptable risk of unplanned reoperation, even with a high proportion of open fractures commonly staged with external fixation.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas Expostas/cirurgia , Infecção da Ferida Cirúrgica/prevenção & controle , Fraturas da Tíbia/cirurgia , Adulto , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Fixadores Externos , Feminino , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura , Fraturas Expostas/diagnóstico por imagem , Fraturas não Consolidadas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Amplitude de Movimento Articular , Reoperação , Estudos Retrospectivos , Fraturas da Tíbia/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...