Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Br J Radiol ; 94(1126): 20210310, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34545764

RESUMO

OBJECTIVES: Myxoid liposarcomas (MLS) show enhanced response to radiotherapy due to their distinctive vascular pattern and therefore could be effectively treated with lower radiation doses. This is a descriptive study to explore the use of functional MRI to identify response in a uniform cohort of MLS patients treated with reduced dose radiotherapy. METHODS: 10 patients with MLS were imaged pre-, during, and post-radiotherapy receiving reduced dose radiotherapy and the response to treatment was histopathologically assessed post-radiotherapy. Apparent diffusion coefficient (ADC), T2* relaxation time, volume transfer constant (Ktrans), initial area under the gadolinium curve over 60 s (IAUGC60) and (Gd) were estimated for a central tumour volume. RESULTS: All parameters showed large inter- and intrasubject variabilities. Pre-treatment (Gd), IAUGC60 and Ktrans were significantly different between responders and non-responders. Post-radiotherapy reductions from baseline were demonstrated for T2*, (Gd), IAUGC60 and Ktrans for responders. No statistically significant ADC differences were demonstrated between the two response groups. Significantly greater early tumour volume reductions were observed for responders. CONCLUSIONS: MLS are heterogenous lesions, characterised by a slow gradual contrast-agent uptake. Pre-treatment vascular parameters, early changes to tumour volume, vascular parameters and T2* have potential in identifying response to treatment. The delayed (Gd) is a suitable descriptive parameter, relying simply on T1 measurements. Volume changes precede changes in MLS functionality and could be used to identify early response. ADVANCES IN KNOWLEDGE: MLS are are characterised by slow gradual contrast-agent uptake. Measurement of the delayed contrast-agent uptake (Gd) is simple to implement and able to discriminate response.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Lipossarcoma Mixoide/diagnóstico por imagem , Lipossarcoma Mixoide/radioterapia , Adulto , Meios de Contraste , Feminino , Humanos , Lipossarcoma Mixoide/patologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Dosagem Radioterapêutica , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Carga Tumoral
2.
Phys Med Biol ; 66(7)2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33631729

RESUMO

Introduction/Background. Despite growing interest in magnetic resonance imaging (MRI), integration in external beam radiotherapy (EBRT) treatment planning uptake varies globally. In order to understand the current international landscape of MRI in EBRT a survey has been performed in 11 countries. This work reports on differences and common themes identified.Methods. A multi-disciplinary Institute of Physics and Engineering in Medicine working party modified a survey previously used in the UK to understand current practice using MRI for EBRT treatment planning, investigate how MRI is currently used and managed as well as identify knowledge gaps. It was distributed electronically within 11 countries: Australia, Belgium, Denmark, Finland, France, Italy, the Netherlands, New Zealand, Sweden, the UK and the USA.Results. The survey response rate within the USA was <1% and hence these results omitted from the analysis. In the other 10 countries the survey had a median response rate of 77% per country. Direct MRI access, defined as either having a dedicated MRI scanner for radiotherapy (RT) or access to a radiology MRI scanner, varied between countries. France, Italy and the UK reported the lowest direct MRI access rates and all other countries reported direct access in ≥82% of centres. Whilst ≥83% of centres in Denmark and Sweden reported having dedicated MRI scanners for EBRT, all other countries reported ≤29%. Anatomical sites receiving MRI for EBRT varied between countries with brain, prostate, head and neck being most common. Commissioning and QA of image registration and MRI scanners varied greatly, as did MRI sequences performed, staffing models and training given to different staff groups. The lack of financial reimbursement for MR was a consistent barrier for MRI implementation for RT for all countries and MR access was a reported important barrier for all countries except Sweden and Denmark.Conclusion. No country has a comprehensive approach for MR in EBRT adoption and financial barriers are present worldwide. Variations between countries in practice, equipment, staffing models, training, QA and MRI sequences have been identified, and are likely to be due to differences in funding as well as a lack of consensus or guidelines in the literature. Access to dedicated MR for EBRT is limited in all but Sweden and Denmark, but in all countries there are financial challenges with ongoing per patient costs. Despite these challenges, significant interest exists in increasing MR guided EBRT planning over the next 5 years.


Assuntos
Iodobenzenos , Humanos , Imageamento por Ressonância Magnética , Masculino , Maleimidas , Planejamento da Radioterapia Assistida por Computador/métodos
3.
Phys Med Biol ; 66(5)2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-33450742

RESUMO

This document gives guidance for multidisciplinary teams within institutions setting up and using an MRI-guided radiotherapy (RT) treatment planning service. It has been written by a multidisciplinary working group from the Institute of Physics and Engineering in Medicine (IPEM). Guidance has come from the experience of the institutions represented in the IPEM working group, in consultation with other institutions, and where appropriate references are given for any relevant legislation, other guidance documentation and information in the literature. Guidance is only given for MRI acquired for external beam RT treatment planning in a CT-based workflow, i.e. when MRI is acquired and registered to CT with the purpose of aiding delineation of target or organ at risk volumes. MRI use for treatment response assessment, MRI-only RT and other RT treatment types such as brachytherapy and gamma radiosurgery are not considered within the scope of this document. The aim was to produce guidance that will be useful for institutions who are setting up and using a dedicated MR scanner for RT (referred to as an MR-sim) and those who will have limited time on an MR scanner potentially managed outside of the RT department, often by radiology. Although not specifically covered in this document, there is an increase in the use of hybrid MRI-linac systems worldwide and brief comments are included to highlight any crossover with the early implementation of this technology. In this document, advice is given on introducing a RT workload onto a non-RT-dedicated MR scanner, as well as planning for installation of an MR scanner dedicated for RT. Next, practical guidance is given on the following, in the context of RT planning: training and education for all staff working in and around an MR scanner; RT patient set-up on an MR scanner; MRI sequence optimisation for RT purposes; commissioning and quality assurance (QA) to be performed on an MR scanner; and MRI to CT registration, including commissioning and QA.


Assuntos
Radioterapia Guiada por Imagem , Humanos , Iodobenzenos , Imageamento por Ressonância Magnética , Maleimidas , Aceleradores de Partículas , Planejamento da Radioterapia Assistida por Computador
4.
Phys Med Biol ; 64(17): 175021, 2019 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-31239419

RESUMO

The benefits of integrating MRI into the radiotherapy pathway are well published, however there is little consensus in guidance on how to commission or implement its use. With a view to developing consensus guidelines for the use of MRI in external beam radiotherapy (EBRT) treatment planning in the UK, a survey was undertaken by an Institute of Physics and Engineering in Medicine (IPEM) working-party to assess the current landscape of MRI use in EBRT in the UK. A multi-disciplinary working-party developed a survey to understand current practice using MRI for EBRT treatment planning; investigate how MRI is currently used and managed; and identify knowledge gaps. The survey was distributed electronically to radiotherapy service managers and physics leads in 71 UK radiotherapy (RT) departments (all NHS and private groups). The survey response rate was 87% overall, with 89% of NHS and 75% of private centres responding. All responding centres include EBRT in some RT pathways: 94% using Picture Archiving and Communication System (PACS) images potentially acquired without any input from RT departments, and 69% had some form of MRI access for planning EBRT. Most centres reporting direct access use a radiology scanner within the same hospital in dedicated (26%) or non-dedicated (52%) RT scanning sessions. Only two centres reported having dedicated RT MRI scanners in the UK, lower than reported in other countries. Six percent of radiotherapy patients in England (data not publically available outside of England) have MRI as part of their treatment, which again is lower than reported elsewhere. Although a substantial number of centres acquire MRI scans for treatment planning purposes, most centres acquire less than five patient scans per month for each treatment site. Commissioning and quality assurance of both image registration and MRI scanners was found to be variable across the UK. In addition, staffing models and training given to different staff groups varied considerably across the UK, reflecting the current lack of national guidelines. The primary barriers reported to MRI implementation in EBRT planning included costs (e.g. lack of a national tariff for planning MRI), lack of MRI access and/or capacity within hospitals. Despite these challenges, significant interest remains in increasing MRI-assisted EBRT planning over the next five years.


Assuntos
Imageamento por Ressonância Magnética/estatística & dados numéricos , Utilização de Procedimentos e Técnicas/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Humanos , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Inquéritos e Questionários , Reino Unido
5.
J Appl Clin Med Phys ; 20(3): 27-36, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30756456

RESUMO

BACKGROUND AND PURPOSE: Intraprostatic fiducial markers (FM) improve the accuracy of radiotherapy (RT) delivery. Here we assess geometric integrity and contouring consistency using a T2*-weighted (T2*W) sequence alone, which allows visualization of the FM. MATERIAL AND METHODS: Ten patients scanned within the Prostate Advances in Comparative Evidence (PACE) trial (NCT01584258) had prostate images acquired with computed tomography (CT) and Magnetic Resonance (MR) Imaging: T2-weighted (T2W) and T2*W sequences. The prostate was contoured independently on each imaging dataset by three clinicians. Interobserver variability was assessed using comparison indices with Monaco ADMIRE (research version 2.0, Elekta AB) and examined for statistical differences between imaging sets. CT and MR images of two test objects were acquired to assess geometric distortion and accuracy of marker positioning. The first was a linear test object comprising straight tubes in three orthogonal directions, the second was a smaller test object with markers suspended in gel. RESULTS: Interobserver variability for prostate contouring was lower for both T2W and T2*W compared to CT, this was statistically significant when comparing CT and T2*W images. All markers are visible in T2*W images with 29/30 correctly identified, only 3/30 are visible in T2W images. Assessment of geometric distortion revealed in-plane displacements were under 0.375 mm in MRI, and through plane displacements could not be detected. The signal loss in the MR images is symmetric in relation to the true marker position shown in CT images. CONCLUSION: Prostate T2*W images are geometrically accurate, and yield consistent prostate contours. This single sequence can be used to identify FM and for prostate delineation in a mixed MR-CT workflow.


Assuntos
Marcadores Fiduciais , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Biomarcadores/metabolismo , Humanos , Masculino , Variações Dependentes do Observador , Neoplasias da Próstata/metabolismo , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Tomografia Computadorizada por Raios X
6.
Br J Radiol ; 92(1095): 20180948, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30676772

RESUMO

OBJECTIVE:: With increasing incorporation of MRI in radiotherapy, we investigate two MRI sequences for prostate delineation in radiographer-led image guidance. METHODS:: Five therapeutic radiographers contoured the prostate individually on CT, T2 weighted (T2W) and T2* weighted (T2*W) imaging for 10 patients. Contours were analysed with Monaco ADMIRE (research v. 2.0) to assess interobserver variability and accuracy by comparison with a gold standard clinician contour. Observers recorded time taken for contouring and scored image quality and confidence in contouring. RESULTS:: There is good agreement when comparing radiographer contours to the gold-standard for all three imaging types with Dice similarity co-efficient 0.91-0.94, Cohen's κ 0.85-0.91, Hausdorff distance 4.6-7.6 mm and mean distance between contours 0.9-1.2 mm. In addition, there is good concordance between radiographers across all imaging modalities. Both T2W and T2*W MRI show reduced interobserver variability and improved accuracy compared to CT, this was statistically significant for T2*W imaging compared to CT across all four comparison metrics. Comparing MRI sequences reveals significantly reduced interobserver variability and significantly improved accuracy on T2*W compared to T2W MRI for DSC and Cohen's κ. Both MRI sequences scored significantly higher compared to CT for image quality and confidence in contouring, particularly T2*W. This was also reflected in the shorter time for contouring, measuring 15.4, 9.6 and 9.8 min for CT, T2W and T2*W MRI respectively. Conclusion: Therapeutic radiographer prostate contours are more accurate, show less interobserver variability and are more confidently and quickly outlined on MRI compared to CT, particularly using T2*W MRI. Advances in knowledge: Our work is relevant for MRI sequence choice and development of the roles of the interprofessional team in the advancement of MRI-guided radiotherapy.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Humanos , Masculino , Variações Dependentes do Observador , Próstata/efeitos da radiação , Tomografia Computadorizada por Raios X/métodos
7.
Magn Reson Imaging ; 52: 53-61, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29859948

RESUMO

PURPOSE: Baseline T2* relaxation time has been proposed as an imaging biomarker in cancer, in addition to Dynamic Contrast-Enhanced (DCE) MRI and diffusion-weighted imaging (DWI) parameters. The purpose of the current work is to investigate sources of error in T2* measurements and the relationship between T2* and DCE and DWI functional parameters in breast cancer. METHODS: Five female volunteers and thirty-two women with biopsy proven breast cancer were scanned at 3 T, with Research Ethics Committee approval. T2* values of the normal breast were acquired from high-resolution, low-resolution and fat-suppressed gradient-echo sequences in volunteers, and compared. In breast cancer patients, pre-treatment T2*, DCE MRI and DWI were performed at baseline. Pathologically complete responders at surgery and non-responders were identified and compared. Principal component analysis (PCA) and cluster analysis (CA) were performed. RESULTS: There were no significant differences between T2* values from high-resolution, low-resolution and fat-suppressed datasets (p > 0.05). There were not significant differences between baseline functional parameters in responders and non-responders (p > 0.05). However, there were differences in the relationship between T2* and contrast-agent uptake in responders and non-responders. Voxels of similar characteristics were grouped in 5 clusters, and large intra-tumoural variations of all parameters were demonstrated. CONCLUSION: Breast T2* measurements at 3 T are robust, but spatial resolution should be carefully considered. T2* of breast tumours at baseline is unrelated to DCE and DWI parameters and contribute towards describing functional heterogeneity of breast tumours.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Pessoa de Meia-Idade , Análise de Componente Principal , Sensibilidade e Especificidade
8.
Phys Imaging Radiat Oncol ; 7: 27-31, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33458402

RESUMO

We demonstrated a general method to evaluate systematic errors related to Magnetic Resonance (MR) imaging sequences in marker-based co-registration of MR and Computed Tomography (CT) images, and investigated the effect of MR image quality in the co-registration process using clinical MR and CT protocols for stereotactic ablative body radiotherapy (SABR) planning of the liver. Small systematic errors (under 1.6 mm) were detected, unlikely to be a clinical risk to liver SABR. The least favourable marker configuration was found to be a co-planar arrangement parallel to the transaxial image plane.

9.
Med Phys ; 45(1): 287-296, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29095484

RESUMO

PURPOSE: To propose a method to quantify T1 and contrast agent uptake in breast dynamic contrast-enhanced (DCE) examinations undertaken with standard clinical fat-suppressed MRI sequences and to demonstrate the proposed approach by comparing the enhancement characteristics of lobular and ductal carcinomas. METHODS: A standard fat-suppressed DCE of the breast was performed at 1.5 T (Siemens Aera), followed by the acquisition of a proton density (PD)-weighted sequence, also fat suppressed. Both sequences were characterized with test objects (T1 ranging from 30 ms to 2,400 ms) and calibration curves were obtained to enable T1 calculation. The reproducibility and accuracy of the calibration curves were also investigated. Healthy volunteers and patients were scanned with Ethics Committee approval. The effect of B0 field inhomogeneity was assessed in test objects and healthy volunteers. The T1 of breast tumors was calculated at different time points (pre-, peak-, and post-contrast agent administration) for 20 patients, pre-treatment (10 lobular and 10 ductal carcinomas) and the two cancer types were compared (Wilcoxon rank-sum test). RESULTS: The calibration curves proved to be highly reproducible (coefficient of variation under 10%). T1 measurements were affected by B0 field inhomogeneity, but frequency shifts below 50 Hz introduced only 3% change to fat-suppressed T1 measurements of breast parenchyma in volunteers. The values of T1 measured pre-, peak-, and post-contrast agent administration demonstrated that the dynamic range of the DCE sequence was correct, that is, image intensity is approximately directly proportional to 1/T1 for that range. Significant differences were identified in the width of the distributions of the post-contrast T1 values between lobular and ductal carcinomas (P < 0.05); lobular carcinomas demonstrated a wider range of post-contrast T1 values, potentially related to their infiltrative growth pattern. CONCLUSIONS: This work has demonstrated the feasibility of fat-suppressed T1 measurements as a tool for clinical studies. The proposed quantitative approach is practical, enabled the detection of differences between lobular and invasive ductal carcinomas, and further enables the optimization of DCE protocols by tailoring the dynamic range of the sequence to the values of T1 measured.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Lobular/diagnóstico por imagem , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/diagnóstico por imagem , Diagnóstico Diferencial , Estudos de Viabilidade , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/instrumentação , Tecido Parenquimatoso/diagnóstico por imagem , Imagens de Fantasmas , Reprodutibilidade dos Testes
10.
Invest Radiol ; 52(9): 554-561, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28538023

RESUMO

OBJECTIVES: The aim of this study was to propose a magnetic resonance imaging acquisition and analysis protocol that uses image segmentation to measure and depict fluid, fat, and muscle volumes in breast cancer-related lymphoedema (BCRL). This study also aims to compare affected and control (unaffected) arms of patients with diagnosed BCRL, providing an analysis of both the volume and the distribution of the different tissue components. MATERIALS AND METHODS: The entire arm was imaged with a fluid-sensitive STIR and a 2-point 3-dimensional T1W gradient-echo-based Dixon sequences, acquired in sagittal orientation and covering the same imaging volume. An automated image postprocessing procedure was developed to simultaneously (1) contour the external volume of the arm and the muscle fascia, allowing separation of the epifacial and subfascial volumes; and to (2) separate the voxels belonging to the muscle, fat, and fluid components. The total, subfascial, epifascial, muscle (subfascial), fluid (epifascial), and fat (epifascial) volumes were measured in 13 patients with unilateral BCRL. Affected versus unaffected volumes were compared using a 2-tailed paired t test; a value of P < 0.05 was considered to be significant. Pearson correlation was used to investigate the linear relationship between fat and fluid excess volumes. The distribution of fluid, fat, and epifascial excess volumes (affected minus unaffected) along the arm was also evaluated using dedicated tissue composition maps. RESULTS: Total arm, epifascial, epifascial fluid, and epifascial fat volumes were significantly different (P < 0.0005), with greater volume in the affected arms. The increase in epifascial volume (globally, 94% of the excess volume) constituted the bulk of the lymphoedematous swelling, with fat comprising the main component. The total fat excess volume summed over all patients was 2.1 times that of fluid. Furthermore, fat and fluid excess volumes were linearly correlated (Pearson r = 0.75), with the fat excess volume being greater than the fluid in 11 subjects. Differences in muscle compartment volume between affected and unaffected arms were not statistically significant, and contributed only 6% to the total excess volume. Considering the distribution of the different tissue excess volumes, fluid accumulated prevalently around the elbow, with substantial involvement of the upper arm in only 3 cases. Fat excess volume was generally greater in the upper arm; however, the relative increase in epifascial volume, which considers the total swelling relative to the original size of the arm, was in 9 cases maximal within the forearm. CONCLUSIONS: Our measurements indicate that excess of fat within the epifascial layer was the main contributor to the swelling, even when a substantial accumulation of fluid was present. The proposed approach could be used to monitor how the internal components of BCRL evolve after presentation, to stratify patients for treatment, and to objectively assess treatment response. This methodology provides quantitative metrics not currently available during the standard clinical assessment of BCRL and shows potential for implementation in clinical practice.


Assuntos
Neoplasias da Mama/complicações , Linfedema/diagnóstico , Linfedema/etiologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Braço/diagnóstico por imagem , Braço/patologia , Feminino , Humanos , Pessoa de Meia-Idade
11.
Clin Cancer Res ; 23(15): 4233-4241, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28314789

RESUMO

Purpose: To evaluate intrinsic susceptibility (IS) MRI for the identification of cycling hypoxia, and the assessment of its extent and spatial distribution, in head and neck squamous cell carcinoma (HNSCC) xenografts and patients.Experimental Design: Quantitation of the transverse relaxation rate, R2*, which is sensitive to paramagnetic deoxyhemoglobin, using serial IS-MRI acquisitions, was used to monitor temporal oscillations in levels of paramagnetic deoxyhemoglobin in human CALR xenografts and patients with HNSCC at 3T. Autocovariance and power spectrum analysis of variations in R2* was performed for each imaged voxel, to assess statistical significance and frequencies of cycling changes in tumor blood oxygenation. Pathologic correlates with tumor perfusion (Hoechst 33342), hypoxia (pimonidazole), and vascular density (CD31) were sought in the xenografts, and dynamic contrast-enhanced (DCE) MRI was used to assess patient tumor vascularization. The prevalence of fluctuations within patient tumors, DCE parameters, and treatment outcome were reported.Results: Spontaneous R2* fluctuations with a median periodicity of 15 minutes were detected in both xenografts and patient tumors. Spatially, these fluctuations were predominantly associated with regions of heterogeneous perfusion and hypoxia in the CALR xenografts. In patients, R2* fluctuations spatially correlated with regions of lymph nodes with low Ktrans values, typically in the vicinity of necrotic cores.Conclusions: IS-MRI can be used to monitor variations in levels of paramagnetic deoxyhemoglobin, associated with cycling hypoxia. The presence of such fluctuations may be linked with impaired tumor vasculature, the presence of which may impact treatment outcome. Clin Cancer Res; 23(15); 4233-41. ©2017 AACR.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Imageamento por Ressonância Magnética , Neovascularização Patológica/diagnóstico por imagem , Animais , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/patologia , Hipóxia Celular/genética , Linhagem Celular Tumoral , Meios de Contraste/uso terapêutico , Feminino , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Linfonodos/patologia , Masculino , Camundongos , Neovascularização Patológica/tratamento farmacológico , Neovascularização Patológica/patologia , Nitroimidazóis/administração & dosagem , Tolerância a Radiação/efeitos dos fármacos , Carcinoma de Células Escamosas de Cabeça e Pescoço , Resultado do Tratamento , Ensaios Antitumorais Modelo de Xenoenxerto
12.
Med Phys ; 43(12): 6354, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27908180

RESUMO

PURPOSE: Stringent quality assurance is required in MRI breast screening to ensure that different scanners and imaging protocols reach similar diagnostic performance. The authors propose a methodology, based on power spectrum analysis (PSA), to evaluate spatial resolution in clinical images. To demonstrate this approach, the authors have retrospectively compared two MRI sequences commonly employed in breast screening. METHODS: In a novel approach to PSA, spatial frequency response curves (SFRCs) were extracted from the images. The SFRC characterizes spatial resolution describing the spatial frequency content of an image over a range of frequencies. Verification of the SFRCs was performed on MRI images of Eurospin agarose gel tubes acquired with different resolution settings. SFRCs of volunteer and patient images obtained with two clinical MRI sequences were then compared. The two sequences differed primarily in k-space coverage pattern, which was either radial (RAD) or linear (LIN). RESULTS: The computed SFRCs were able to demonstrate the differences between RAD and LIN sequences in relatively small groups of subjects. The curves showed a similar pattern of decay in both volunteer and patient images, indicating that the spatial frequency response is mainly determined by the imaging protocol and not by intersubject anatomical differences. The LIN protocol produced images with increased sharpness; this was reflected in the corresponding SFRCs, which showed a higher content of spatial frequencies associated with image details. CONCLUSIONS: The SFRC can provide an objective assessment of the presence of spatial details in the image and represent a useful quality assurance tool in the evaluation of different breast screening protocols. With a reference image, a comparative analysis of the SFRCs could ensure that equivalent image quality is achieved across different scanners and sites.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Programas de Rastreamento/normas , Razão Sinal-Ruído , Adulto , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade
13.
Med Phys ; 43(11): 6024, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27806585

RESUMO

PURPOSE: To investigate the effects of different time-resolved angiography with stochastic trajectories (TWIST) k-space undersampling schemes on calculated pharmacokinetic dynamic contrast-enhanced (DCE) vascular parameters. METHODS: A digital perfusion phantom was employed to simulate effects of TWIST on characteristics of signal changes in DCE. Furthermore, DCE-MRI was acquired without undersampling in a group of patients with head and neck squamous cell carcinoma and used to simulate a range of TWIST schemes. Errors were calculated as differences between reference and TWIST-simulated DCE parameters. Parametrical error maps were used to display the averaged results from all tumors. RESULTS: For a relatively wide range of undersampling schemes, errors in pharmacokinetic parameters due to TWIST were under 10% for the volume transfer constant, Ktrans, and total extracellular extravascular space volume, Ve. TWIST induced errors in the total blood plasma volume, Vp, were the largest observed, and these were inversely dependent on the area of the fully sampled k-space. The magnitudes of errors were not correlated with Ktrans, Vp and weakly correlated with Ve. CONCLUSIONS: The authors demonstrated methods to validate and optimize k-space view-sharing techniques for pharmacokinetic DCE studies using a range of clinically relevant spatial and temporal patient derived data. The authors found a range of undersampling patterns for which the TWIST sequence can be reliably used in pharmacokinetic DCE-MRI. The parameter maps created in the study can help to make a decision between temporal and spatial resolution demands and the quality of enhancement curve characterization.


Assuntos
Angiografia , Meios de Contraste/farmacocinética , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/metabolismo , Imageamento por Ressonância Magnética , Adulto , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Processos Estocásticos
14.
Radiother Oncol ; 121(2): 187-192, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27838146

RESUMO

AIM: To determine the levels at which consensus could be reached regarding general and site-specific principles of MRI simulation for offline MRI-aided external beam radiation treatment planning. METHODS: A process inspired by the Delphi method was employed to determine levels of consensus using a series of questionnaires interspersed with controlled opinion feedback. RESULTS: In general, full consensus was reached regarding general principles of MRI simulation. However, the level of consensus decreased when site-specific principles of MRI simulation were considered. CONCLUSIONS: These results indicate variability in MRI simulation approaches that are largely explained by the use of MRI in combination with CT.


Assuntos
Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Consenso , Técnica Delphi , Humanos , Órgãos em Risco , Garantia da Qualidade dos Cuidados de Saúde , Tomografia Computadorizada por Raios X
15.
Radiother Oncol ; 120(2): 356-62, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27222296

RESUMO

BACKGROUND AND PURPOSE: Magnetic resonance (MR) and computed tomography (CT) images are degraded in the presence of metallic implants. We investigate whether SEMAC (Slice Encoding for Metal Artifact Correction) MR is advantageous for radiotherapy (RT) planning. METHODS: Conventional and SEMAC MR protocols were compared (1.5T). A spine fixation device suspended in gelatine, two patients with spine fixation devices and six patients with bilateral hip replacements were scanned with both conventional and SEMAC protocols. In spine patients the visibility of the spinal canal and spinal cord was assessed; in prostate patients, the visibility of the prostate, pelvic structures and the pelvic girdle. RESULTS: The signal loss volume surrounding the spine fixation device was reduced by approximately 20% when the SEMAC protocol was employed, and registration errors were reduced. For spine patients, the spinal canal was completely visible only using the SEMAC protocol. In hip replacement patients, metal artifacts were local; the signal loss extended to the internal surface of the acetabulum in eight implants with conventional protocols, but only in four using SEMAC. CONCLUSIONS: SEMAC MR contributes towards correct co-registration of MR and CT images for RT planning, and is particularly relevant when the TV or OARs are close to implants.


Assuntos
Imageamento por Ressonância Magnética/métodos , Próteses e Implantes , Planejamento da Radioterapia Assistida por Computador/métodos , Artefatos , Fixação Interna de Fraturas/instrumentação , Humanos , Aumento da Imagem , Masculino , Metais , Neoplasias da Próstata/radioterapia , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
16.
PLoS One ; 11(3): e0152152, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27011312

RESUMO

OBJECTIVES: To evaluate sources of error in the Magnetic Resonance Imaging (MRI) measurement of percent fibroglandular tissue (%FGT) using two-point Dixon sequences for fat-water separation. METHODS: Ten female volunteers (median age: 31 yrs, range: 23-50 yrs) gave informed consent following Research Ethics Committee approval. Each volunteer was scanned twice following repositioning to enable an estimation of measurement repeatability from high-resolution gradient-echo (GRE) proton-density (PD)-weighted Dixon sequences. Differences in measures of %FGT attributable to resolution, T1 weighting and sequence type were assessed by comparison of this Dixon sequence with low-resolution GRE PD-weighted Dixon data, and against gradient-echo (GRE) or spin-echo (SE) based T1-weighted Dixon datasets, respectively. RESULTS: %FGT measurement from high-resolution PD-weighted Dixon sequences had a coefficient of repeatability of ±4.3%. There was no significant difference in %FGT between high-resolution and low-resolution PD-weighted data. Values of %FGT from GRE and SE T1-weighted data were strongly correlated with that derived from PD-weighted data (r = 0.995 and 0.96, respectively). However, both sequences exhibited higher mean %FGT by 2.9% (p < 0.0001) and 12.6% (p < 0.0001), respectively, in comparison with PD-weighted data; the increase in %FGT from the SE T1-weighted sequence was significantly larger at lower breast densities. CONCLUSION: Although measurement of %FGT at low resolution is feasible, T1 weighting and sequence type impact on the accuracy of Dixon-based %FGT measurements; Dixon MRI protocols for %FGT measurement should be carefully considered, particularly for longitudinal or multi-centre studies.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Adulto , Mama/patologia , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade
17.
J Magn Reson Imaging ; 44(1): 72-80, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26800280

RESUMO

PURPOSE: To determine whether quantitation of T2* is sufficiently repeatable and sensitive to detect clinically relevant oxygenation levels in head and neck squamous cell carcinoma (HNSCC) at 3T. MATERIALS AND METHODS: Ten patients with newly diagnosed locally advanced HNSCC underwent two magnetic resonance imaging (MRI) scans between 24 and 168 hours apart prior to chemoradiotherapy treatment. A multiple gradient echo sequence was used to calculate T2* maps. A quadratic function was used to model the blood transverse relaxation rate as a function of blood oxygenation. A set of published coefficients measured at 3T were incorporated to account for tissue hematocrit levels and used to plot the dependence of fractional blood oxygenation (Y) on T2* values, together with the corresponding repeatability range. Repeatability of T2* using Bland-Altman analysis, and calculation of limits of agreement (LoA), was used to assess the sensitivity, defined as the minimum difference in fractional blood oxygenation that can be confidently detected. RESULTS: T2* LoA for 22 outlined tumor volumes were 13%. The T2* dependence of fractional blood oxygenation increases monotonically, resulting in increasing sensitivity of the method with increasing blood oxygenation. For fractional blood oxygenation values above 0.11, changes in T2* were sufficient to detect differences in blood oxygenation greater than 10% (Δ T2* > LoA for ΔY > 0.1). CONCLUSION: Quantitation of T2* at 3T can detect clinically relevant changes in tumor oxygenation within a wide range of blood volumes and oxygen tensions, including levels reported in HNSCC. J. Magn. Reson. Imaging 2016;44:72-80.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/metabolismo , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/metabolismo , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Oxigênio/metabolismo , Biomarcadores Tumorais/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carcinoma de Células Escamosas de Cabeça e Pescoço
18.
Phys Med Biol ; 61(1): 37-49, 2016 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-26605957

RESUMO

MRI has been extensively used in breast cancer staging, management and high risk screening. Detection sensitivity is paramount in breast screening, but variations of signal-to-noise ratio (SNR) as a function of position are often overlooked. We propose and demonstrate practical methods to assess spatial SNR variations in dynamic contrast-enhanced (DCE) breast examinations and apply those methods to different protocols and systems. Four different protocols in three different MRI systems (1.5 and 3.0 T) with receiver coils of different design were employed on oil-filled test objects with and without uniformity filters. Twenty 3D datasets were acquired with each protocol; each dataset was acquired in under 60 s, thus complying with current breast DCE guidelines. In addition to the standard SNR calculated on a pixel-by-pixel basis, we propose other regional indices considering the mean and standard deviation of the signal over a small sub-region centred on each pixel. These regional indices include effects of the spatial variation of coil sensitivity and other structured artefacts. The proposed regional SNR indices demonstrate spatial variations in SNR as well as the presence of artefacts and sensitivity variations, which are otherwise difficult to quantify and might be overlooked in a clinical setting. Spatial variations in SNR depend on protocol choice and hardware characteristics. The use of uniformity filters was shown to lead to a rise of SNR values, altering the noise distribution. Correlation between noise in adjacent pixels was associated with data truncation along the phase encoding direction. Methods to characterise spatial SNR variations using regional information were demonstrated, with implications for quality assurance in breast screening and multi-centre trials.


Assuntos
Neoplasias da Mama/diagnóstico , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Artefatos , Feminino , Humanos , Imageamento por Ressonância Magnética/normas , Razão Sinal-Ruído
19.
Phys Med Biol ; 60(22): R323-61, 2015 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-26509844

RESUMO

The use of magnetic resonance imaging (MRI) in radiotherapy (RT) planning is rapidly expanding. We review the wide range of image contrast mechanisms available to MRI and the way they are exploited for RT planning. However a number of challenges are also considered: the requirements that MR images are acquired in the RT treatment position, that they are geometrically accurate, that effects of patient motion during the scan are minimized, that tissue markers are clearly demonstrated, that an estimate of electron density can be obtained. These issues are discussed in detail, prior to the consideration of a number of specific clinical applications. This is followed by a brief discussion on the development of real-time MRI-guided RT.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem , Humanos , Neoplasias/patologia
20.
PLoS One ; 10(9): e0138545, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26398888

RESUMO

PURPOSE: To describe a methodology, based on cluster analysis, to partition multi-parametric functional imaging data into groups (or clusters) of similar functional characteristics, with the aim of characterizing functional heterogeneity within head and neck tumour volumes. To evaluate the performance of the proposed approach on a set of longitudinal MRI data, analysing the evolution of the obtained sub-sets with treatment. MATERIAL AND METHODS: The cluster analysis workflow was applied to a combination of dynamic contrast-enhanced and diffusion-weighted imaging MRI data from a cohort of squamous cell carcinoma of the head and neck patients. Cumulative distributions of voxels, containing pre and post-treatment data and including both primary tumours and lymph nodes, were partitioned into k clusters (k = 2, 3 or 4). Principal component analysis and cluster validation were employed to investigate data composition and to independently determine the optimal number of clusters. The evolution of the resulting sub-regions with induction chemotherapy treatment was assessed relative to the number of clusters. RESULTS: The clustering algorithm was able to separate clusters which significantly reduced in voxel number following induction chemotherapy from clusters with a non-significant reduction. Partitioning with the optimal number of clusters (k = 4), determined with cluster validation, produced the best separation between reducing and non-reducing clusters. CONCLUSION: The proposed methodology was able to identify tumour sub-regions with distinct functional properties, independently separating clusters which were affected differently by treatment. This work demonstrates that unsupervised cluster analysis, with no prior knowledge of the data, can be employed to provide a multi-parametric characterization of functional heterogeneity within tumour volumes.


Assuntos
Neoplasias de Cabeça e Pescoço/patologia , Cabeça/patologia , Pescoço/patologia , Algoritmos , Carcinoma de Células Escamosas/patologia , Análise por Conglomerados , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Estudos Longitudinais , Linfonodos/patologia , Análise de Componente Principal/métodos , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...