1.
Pacing Clin Electrophysiol ; 29(9): 946-52, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16981917

RESUMO

INTRODUCTION: In patients who have an indication for an implantable cardioverter defibrillator (ICD) a dual-chamber device is indicated in the case of concomitant significant sinus node disease or atrioventricular block. It is a matter of debate whether dual-chamber ICD may be beneficial for patients with preserved sinus and atrioventricular nodal function as data from prospective randomized trials are limited. Mid- or long-term follow-up data are unavailable. METHODS AND RESULTS: One hundred patients (age 60+/-12 years, 11 women) with the indication for the implantation of an ICD and without antibradycardia pacing indication were randomly assigned to either receive a dual-chamber ICD (n=52) or a single-chamber ICD (n=48). Patients were followed-up for a mean of 52+/-14 months. Mortality and arrhythmogenic morbidity were assessed. All-cause mortality was 21% for single-chamber and 31% for dual-chamber ICD recipients, respectively (P=0.26). Cardiovascular mortality was 13% for single-chamber ICD recipients versus 21% in the dual-chamber group (P=0.25). Subgroup analysis using 35% of ventricular paced beats as cutoff value in the dual-chamber ICD group revealed a 42% mortality rate for the patients with frequent ventricular pacing compared to 10% of patients with a low rate of ventricular pacing (P=0.05, relative risk 4.21, 95% confidence interval: 0.9-19.8). As for arrhythmogenic morbidity, the difference in the ventricular tachyarrhythmia load was not different in both groups (single chamber: 23+/-74 VT episodes, dual chamber: 54+/-134 VT episodes, P=0.17). CONCLUSION: In ICD recipients without conventional indication for dual-chamber pacing, dual chamber compared to single-chamber ICD has no advantage concerning mortality and arrhythmogenic morbidity in a long-term follow-up. In these patients the implantation of a single-chamber device is sufficient.


Assuntos
Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/mortalidade , Medição de Risco/métodos , Cardioversão Elétrica/métodos , Análise de Falha de Equipamento , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Prognóstico , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
2.
Pacing Clin Electrophysiol ; 27(2): 221-3, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14764174

RESUMO

Electromagnetic interference may result in transient or persistent suspension of antitachycardia therapies in ICDs. The incidence of such events has not been assessed so far. Patient charts were retrospectively analyzed for the occurrence of temporary suspension of antitachycardia therapies as it is stored in the Holter of St. Jude Medical or Ventritex ICDs. Follow-up data of 46 patients and 83.7-patient years were analyzed. Overall, 43 episodes of transient ICD inactivation occurred. Twenty-two of these episodes were related to intentional ICD inactivation in the emergency room or during surgery and 12 episodes were related to ICD follow-up. In nine episodes an environmental source of electromagnetic interference is presumed. None of the interactions resulted in persistent ICD inactivation or reprogramming of the devices. The risk for temporary suspension of ICD therapies unrelated to surgery, intentional magnet application in the emergency room, or routine follow-up is 11% per patient and year. Evaluation of its potential sources and the prevalence of ICD inhibition is warranted.


Assuntos
Desfibriladores Implantáveis , Magnetismo/instrumentação , Taquicardia/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Campos Eletromagnéticos , Desenho de Equipamento , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
J Am Coll Cardiol ; 41(11): 2054-9, 2003 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-12798581

RESUMO

OBJECTIVES: The aim of this study was to determine whether airport metal detector gates (AMDGs) interfere with pacemakers (PMs) or implantable cardioverter-defibrillators (ICDs). BACKGROUND: It is currently unknown whether AMDGs interfere with implanted PMs or ICDs. METHODS: A total of 348 consecutive patients (200 PM and 148 ICD recipients) have been tested for the occurrence of electromagnetic interference (EMI) within the electromagnetic field of a worldwide-used airport metal detector. RESULTS: No interference, such as pacing or sensing abnormalities, was observed in any of the 200 PM and 148 ICD patients; also no reprogramming occurred. CONCLUSIONS: In vivo testing of PM and ICD systems showed no EMI with a standard AMDG. Clinically relevant interactions with implanted PMs or ICDs seem unlikely.


Assuntos
Desfibriladores Implantáveis , Campos Eletromagnéticos/efeitos adversos , Marca-Passo Artificial , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Criança , Eletrodos Implantados , Desenho de Equipamento , Segurança de Equipamentos , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Átrios do Coração/patologia , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte/epidemiologia , Sensibilidade e Especificidade , Resultado do Tratamento
4.
Int J Cardiol ; 89(1): 79-85, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12727008

RESUMO

BACKGROUND: This study was performed to elaborate an electrocardiographic (ECG) algorithm enabling assignment of an occluded coronary artery in acute myocardial infarction (AMI). PATIENTS AND INTERVENTIONS: In 109 patients (age, 59+/-12 years) with AMI (pain onset, 3.6+/-1.7 h), coronary angiography with PTCA/stenting of the culprit lesion was performed. The diagnosis of AMI was confirmed by emergency coronary angiography and laboratory analyses. Admission ECG parameters (amplitude of R-wave, ST-segment deviation, presence of Q-wave, deflection of T-wave) in standard 12-lead ECG plus extended (V(3)R to V(6)R and V(7-9)) leads were subjected to classification and regression tree (CART) analysis. RESULTS: Continuous CART analysis assessed ST-segment deviations in V(2) and V(5)R. AMI of the left anterior descending (LAD), right coronary artery (RCA) and left circumflex coronary artery (CX) were correctly classified in 94, 64, and 91% of cases, respectively. Dichotomised CART analysis assessed ST-segment deviations in V(2), V(5)R, and aVF. True classification rates for LAD, RCA, and CX amounted to 84, 74, and 71%, respectively. CONCLUSIONS: Dichotomised CART analysis is a simple means of differentiation of CX from RCA occlusion during AMI.


Assuntos
Eletrocardiografia , Infarto do Miocárdio/diagnóstico , Algoritmos , Angioplastia Coronária com Balão , Distribuição de Qui-Quadrado , Angiografia Coronária , Árvores de Decisões , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
J Cardiovasc Electrophysiol ; 14(2): 176-81, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12693501

RESUMO

INTRODUCTION: Information on the spatiotemporal organization of atrial activity at the onset of atrial fibrillation (AF) is limited. METHODS AND RESULTS: The study consisted of 26 consecutive patients (22 men and 4 women; mean age 56 +/- 9 years) with AF in whom the left atrium (LA) was mapped using a noncontact mapping system. At the onset of AF, the AF cycle lengths and wavefronts were analyzed at the site of origin of the triggering atrial premature complex (APC) and five predefined sites within the LA (superior, anterior, posterior, lateral, and septal walls). If repetitive activity was observed at the site of origin of APCs, triggered AF episodes were considered as focally driven. APCs that induced AF had shorter coupling intervals than APCs that did not induce AF (300 +/- 41 msec vs 392 +/- 64 msec, P < 0.001). Immediately after AF onset, repetitive firing was crucial for maintenance of arrhythmia in 52 (80%) of 65 AF episodes. In 13 AF onset episodes (20%), AF was maintained by other mechanisms. The number of LA wavefronts after AF onset was lower in focally driven AF episodes compared with episodes in which no focally driven activity was observed (1.9 +/- 0.6 v. 2.3 +/- 2.3 wavefronts, P < 0.05). After the onset of AF, the posterior wall of the LA showed the earliest disorganized activity (after 5.2 +/- 3.1 cycles). CONCLUSION: In the majority of AF episodes (80%), repetitive firing from the triggering foci may play an important role in maintaining AF immediately after arrhythmia onset. In 20% of the episodes, AF at early stages seems to be maintained by other mechanisms. The capability of APCs to induce AF depends on the coupling interval and the focus localization. The posterior wall of the LA shows the earliest disorganization of wavefronts at the onset of AF.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Frequência Cardíaca , Imageamento Tridimensional/métodos , Adulto , Idoso , Fibrilação Atrial/classificação , Complexos Atriais Prematuros/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
Eur Heart J ; 24(10): 956-62, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12714027

RESUMO

AIMS: The purpose of this study was to evaluate the acute success rate and long-term efficacy of radiofrequency ablation of common type atrial flutter (AFL) by using a standardised anatomical approach in a large series of patients and to assess the influence of right atrial isthmus ablation on the occurrence of atrial fibrillation. There are no large scale prospective or retrospective multicentre studies for radiofrequency ablation of AFL. METHODS AND RESULTS: The study population consisted of 363 consecutive patients with AFL (mean age 58+/-16 years, 265 men) who underwent radiofrequency ablation at the inferior vena cava-tricuspid annulus (IVC-TA) isthmus using a standardised anatomic approach. Bidirectional isthmus block at the IVC-TA was achieved in 328 patients (90%). Following radiofrequency ablation, 343 patients (95%) were followed for a mean of 496+/-335 days. During the follow-up period, 310 patients (90%) remained free of AFL recurrences. Multivariate analysis identified five independent predictors of AFL recurrence: fluoroscopy time (p<0.001), atrial fibrillation after AFL ablation (p=0.01), lack of bidirectional block (p=0.02), reduced left ventricular function (p=0.035) and right atrial dimensions (p=0.046). Atrial fibrillation occurrence was significantly reduced after AFL ablation (112 in 343 patients, 33%) as compared to occurrence of atrial fibrillation before radiofrequency ablation (198 in 363 patients, 55%, p<0.001). CONCLUSIONS: The current anatomical ablation approach for AFL and criteria for evaluation of the IVC-TA isthmus block is associated with an acute success rate of 90% and a long-term recurrence rate of 10%. Radiofrequency ablation of common AFL results in a significant reduction in the occurrence of atrial fibrillation.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Doença Aguda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Flutter Atrial/fisiopatologia , Criança , Pré-Escolar , Eletrofisiologia , Feminino , Seguimentos , Humanos , Lactente , Masculino , Pessoa de Meia-Idade
7.
Am J Cardiol ; 91(2): 159-63, 2003 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-12521627

RESUMO

Information about the clinical efficacy and complications of the circumferential mapping and isolation of the pulmonary veins (PVs) in patients with atrial fibrillation (AF) is still limited. The present study included 75 patients (mean age 58 +/- 11 years, 20 women) with paroxysmal (n = 69) or persistent AF (n = 6). Mapping of PVs was performed with a circumferential mapping catheter. After preferential PV-left atrium (LA) electric inputs were defined, radiofrequency ablation was performed until complete isolation of the PVs from the LA was achieved. A total of 226 PVs were mapped; 195 (86%) showed typical PV potentials. Complete isolation of PVs from the LA was achieved in 173 PVs (89%). Detailed follow-up, including 7-day Holter monitoring at 1, 4, 9, and 12 months after intervention was performed. If AF reoccurred, PVs were mapped and reisolated. After a mean follow-up period of 230 +/- 133 days, 38 of 75 patients (51%) were in sinus rhythm. At 1, 4, and 9 months of follow-up, 31 of 65 patients (48%), 36 of 53 patients (68%, p = 0.04 as compared with the first month), and 21 of 28 patients (75%, p = 0.025 as compared with the first month), respectively, were in sinus rhythm. During follow-up, 30 patients (40%) underwent a second ablation procedure due to recurrence. Recurrences were related to resumption of PV muscle-left atrial conduction (27 patients) and/or extra PV foci (12 patients) or nonablated PVs (8 patients). Complications occurred in 17 patients (22%). PV stenosis was detected in 13 patients (25% to 50% in 7 patients and >50% in 6 patients). Pericardial effusion occurred in 4 patients. It was concluded that isolation of the PV from the LA is moderately effective in the prevention of AF recurrence and could be associated with serious acute and long-term complications.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/métodos , Veias Pulmonares/fisiopatologia , Adulto , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Radiografia , Recidiva , Fatores de Risco
8.
Am J Cardiol ; 89(12): 1381-7, 2002 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-12062732

RESUMO

Pulmonary veins are considered to be the most common origin of the focal activity that triggers the onset of atrial fibrillation (AF). However, little is known about the importance of ectopic activity located outside the pulmonary veins. This study included 45 patients (8 women and 37 men, mean age 55 +/- 12 years) with paroxysmal (n = 25) and persistent (n = 20) AF in whom multisite mapping of the right and left atria was performed using a 64-electrode basket catheter (n = 21) or a noncontact mapping system (n = 24). Spontaneous or orciprenaline-induced atrial premature complexes (APCs) were mapped. In all, 94 AF onsets from 38 distinct foci in 30 patients were observed and analyzed. Of these foci, 20 (53%) were located in pulmonary veins and 18 (47%) were located outside the pulmonary veins in other parts of the atria. In 22 patients (73%), AF was reproducibly induced by APCs from a single focus (59 episodes). In 8 patients (27%), AF originated from 2 distinct foci (35 episodes). Additionally, 20 of 30 patients (67%) who developed AF had APCs in different locations not inducing AF. APCs inducing AF had shorter coupling intervals than APCs not inducing AF (307 +/- 54 vs 409 +/- 76 ms, p <0.001). This study showed that 47% of ectopic foci triggering the onset of AF were located outside the pulmonary veins in extravenous parts of the left atrium and the right atrium, and 27% of patients had AF onsets of bifocal origin. These data challenge the current opinion that extrapulmonary foci play a minor role in inducing AF.


Assuntos
Fibrilação Atrial/etiologia , Complexos Atriais Prematuros/diagnóstico , Técnicas Eletrofisiológicas Cardíacas/métodos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Complexos Atriais Prematuros/complicações , Complexos Atriais Prematuros/fisiopatologia , Cateterismo Cardíaco/métodos , Ablação por Cateter , Feminino , Átrios do Coração/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Veias Pulmonares , Resultado do Tratamento
9.
Circulation ; 105(25): 2946-9, 2002 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-12081985

RESUMO

BACKGROUND: Early resolution of ST-segment elevation is an indicator of final infarct size and clinical outcomes. Whether this correlation is an expression of initial infarct characteristics or degree of myocardial salvage achieved with reperfusion therapy is unclear. METHODS AND RESULTS: We prospectively included 243 patients with acute myocardial infarction (AMI) treated with either coronary stenting (122 patients) or thrombolysis (121 patients). Serial 12-lead electrocardiograms (ECG) were performed at baseline and 90 minutes after initiation of therapy. ST-segment resolution was defined as complete (> or =70%), partial (<70% to 30%), or no resolution (<30%). Paired technetium-99m sestamibi scintigraphic studies were performed to calculate the initial perfusion defect, final infarct size, and the proportion of initial defect salvaged with reperfusion (salvage index). ST-segment resolution correlated significantly with salvage index (P=0.008), final infarct size (P<0.001), and 6-month mortality (P=0.03). In the groups with complete, partial, and no resolution, salvage index was 0.54+/-0.32, 0.39+/-0.36, and 0.33+/-0.60; final infarct size was 12.5+/-12.0%, 20.0+/-13.9%, and 22.7+/-19.4% of the left ventricle; 6-month mortality was 2.4%, 6.2%, and 12.8%, respectively. After adjustment for baseline characteristics, ST-segment resolution was the second strongest predictor of salvage index (P=0.007) after the type of reperfusion, stenting, or thrombolysis (P=0.001); it was greater after stenting than after thrombolysis (P<0.001). CONCLUSION: Early resolution of ST-segment elevation in surface ECG correlates with myocardial salvage as assessed by scintigraphy in patients with AMI after reperfusion therapy. These data provide an explanation for the favorable prognostic value of the ST-segment resolution and support the use of this parameter to compare the efficacy of different reperfusion strategies.


Assuntos
Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/terapia , Reperfusão Miocárdica , Angiografia Cintilográfica/métodos , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Stents , Terapia Trombolítica , Fatores de Tempo , Resultado do Tratamento
10.
J Interv Card Electrophysiol ; 7(3): 255-6, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12510137

RESUMO

Electromagnetic interference with implantable cardioverter defibrillators (ICD) can cause inappropriate delivery of therapies or temporary inhibition of ICD functions. The presented case describes electromagnetic interference between a washing machine and an ICD resulting in an inappropriate discharge of the device due to false detection of ventricular fibrillation.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Utensílios Domésticos , Radiação , Fibrilação Ventricular/prevenção & controle , Adulto , Eletrocardiografia , Falha de Equipamento , Feminino , Humanos