1.
J Virol Methods ; 246: 117-124, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28479349

RESUMO

Zika virus is an arthropod-borne flavivirus that has rapidly developed into a world-wide concern. Discovered in 1947, the virus was relatively obscure until an outbreak occurred in 2007 in the Yap islands and spread eventually to the Americas in 2015. Only 20% of patients infected with Zika virus develop symptoms. However, there can be serious consequences of infection including birth defects in developing fetuses and links to Guillain-Barré syndrome. The swift rise in infections has necessitated the development of diagnostic tests for both the detection of viral RNA and the presence of virus-specific antibodies. Abbott has developed a dual target RT-PCR assay for the detection of Zika virus RNA within serum, plasma, whole blood, and urine using the automated m2000 system for sample extraction to result reporting. The Abbott RealTime ZIKA assay has a limit of detection of 30 copies per mL in serum, 40 copies per mL in plasma and urine, and 120 copies per mL in whole blood and demonstrates high specificity against challenges from closely related infectious agents.


Assuntos
RNA Viral/análise , Reação em Cadeia da Polimerase em Tempo Real/métodos , Infecção por Zika virus/diagnóstico , Zika virus/isolamento & purificação , Automação Laboratorial/instrumentação , Humanos , Limite de Detecção , RNA Viral/sangue , RNA Viral/genética , RNA Viral/urina , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Sensibilidade e Especificidade , Zika virus/genética , Infecção por Zika virus/virologia
3.
J Clin Microbiol ; 54(6): 1512-1519, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27030491

RESUMO

Commutability of quantitative standards allows patient results to be compared across molecular diagnostic methods and laboratories. This is critical to establishing quantitative thresholds for use in clinical decision-making. A matrix effect associated with the 1st cytomegalovirus (CMV) WHO international standard (IS) was identified using the Abbott RealTime CMV assay. A commutability study was performed to compare the CMV WHO IS and patient specimens diluted in plasma and whole blood. Patient specimens showed similar CMV DNA quantitation values regardless of the diluent or extraction procedure used. The CMV WHO IS, on the other hand, exhibited a matrix effect. The CMV concentration reported for the WHO IS diluted in plasma was within the 95% prediction interval established with patient samples. In contrast, the reported DNA concentration of the CMV WHO IS diluted in whole blood was reduced approximately 0.4 log copies/ml, and values fell outside the 95% prediction interval. Calibrating the assay by using the CMV WHO IS diluted in whole blood would introduce a bias for CMV whole-blood quantitation; samples would be reported as having higher measured concentrations, by approximately 0.4 log IU/ml. Based on the commutability study with patient samples, the RealTime CMV assay was standardized based on the CMV WHO IS diluted in plasma. A revision of the instructions for use of the CMV WHO IS should be considered to alert users of the potential impact from the diluent matrix. The identification of a matrix effect with the CMV WHO IS underscores the importance of assessing commutability of the IS in order to achieve consistent results across methods.


Assuntos
Infecções por Citomegalovirus/virologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase em Tempo Real/normas , Padrões de Referência , Carga Viral/normas , Humanos , Projetos Piloto
4.
Hepatol Res ; 41(3): 217-24, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21338453

RESUMO

AIM: In the treatment of chronic hepatitis C, pegylated interferon (PEG-IFN) and ribavirin combination therapy must be continued for an adequate duration to improve the rate of sustained virological response. We attempted to predict the time point at which serum hepatitis C virus (HCV) RNA are undetectable during combination therapy. METHODS: Patients with HCV genotype 1b were enrolled in a model preparation (n = 35) and a validation group (n = 70). All patients received PEG-IFN-α-2b/ribavirin combination therapy for at least 48 weeks, and serological samples were screened a minimum of 17 times during the therapy. Serum HCV RNA were measured by the Abbott RealTime HCV assay. Using the HCV dynamics model described by Neumann et al., we used multiple linear regression analysis to select factors that affected the undetectable time point. RESULTS: Difference in viral load between weeks 1 and 2 was the only predictive factor for the undetectable time point of serum HCV RNA (r(2) = 0.67, P < 0.0005), and we derived the following prediction equation: undetectable time point (week) = 13.495 × (viral load at day 14 [log IU/mL] - viral load at day 7 [log IU/mL]) + 25.456. The equation was applicable to the validation group. CONCLUSION: We created a formula for predicting the undetectable time point from viral load measurements early in PEG-IFN-α-2b/ribavirin combination therapy. An early response reflects sensitivity to therapy, and the estimation of an undetectable time point would be useful for determining the optimal duration of treatment for chronic hepatitis C patients.

5.
J Mol Diagn ; 12(2): 133-43, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20075208

RESUMO

The utility of quantitative molecular diagnostics for patient management depends on the ability to relate patient results to prior results or to absolute values in clinical practice guidelines. To do this, those results need to be comparable across time and methods, either by producing the same value across methods and test versions or by using reliable and stable conversions. Universally available standards and reference materials specific to quantitative molecular technologies are critical to this process but are few in number. This review describes recent history in the establishment of international standards for nucleic acid test development, organizations involved in current efforts, and future issues and initiatives.


Assuntos
Doenças Transmissíveis/diagnóstico , Cooperação Internacional , Patologia Molecular/normas , Padrões de Referência , Humanos , Infectologia/métodos , Infectologia/normas , Organização Mundial da Saúde
6.
J Clin Virol ; 44(4): 292-6, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19286419

RESUMO

BACKGROUND: Automated sample preparation systems must meet the demands of routine diagnostics laboratories with regard to performance characteristics and compatibility with downstream assays. OBJECTIVES: In this study, the performance of QIAGEN EZ1 DSP Virus Kit on the BioRobot EZ1 DSP was evaluated in combination with the Abbott RealTime HIV-1, HCV, and HBV assays, followed by thermalcycling and detection on the Abbott m2000rt platform. STUDY DESIGN: The following performance characteristics were evaluated: linear range and precision, sensitivity, cross-contamination, effects of interfering substances and correlation. RESULTS: Linearity was observed within the tested ranges (for HIV-1: 2.0-6.0 log copies/ml, HCV: 1.3-6.9 log IU/ml, HBV: 1.6-7.6 log copies/ml). Excellent precision was obtained (inter-assay standard deviation for HIV-1: 0.06-0.17 log copies/ml (>2.17 log copies/ml), HCV: 0.05-0.11 log IU/ml (>2.09 log IU/ml), HBV: 0.03-0.07 log copies/ml (>2.55 log copies/ml)), with good sensitivity (95% hit rates for HIV-1: 50 copies/ml, HCV: 12.5 IU/ml, HBV: 10 IU/ml). No cross-contamination was observed, as well as no negative impact of elevated levels of various interfering substances. In addition, HCV and HBV viral load measurements after BioRobot EZ1 DSP extraction correlated well with those obtained after Abbott m2000sp extraction. CONCLUSIONS: This evaluation demonstrates that the QIAGEN EZ1 DSP Virus Kit provides an attractive solution for fully automated, low throughput sample preparation for use with the Abbott RealTime HIV-1, HCV, and HBV assays.


Assuntos
Infecções por HIV/diagnóstico , Hepatite B/diagnóstico , Hepatite C/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Manejo de Espécimes/métodos , Virologia/métodos , HIV-1/isolamento & purificação , Hepacivirus/isolamento & purificação , Humanos , Orthohepadnavirus/isolamento & purificação , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...