1.
Sleep Med ; 119: 139-146, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38678757

RESUMO

BACKGROUND: Intraoral devices, with or without negative oral pressure, can stabilize the oropharynx and reduce obstructive sleep apneas. We tested the hypothesis that treatment with the iNAP® Sleep Therapy System, which applies negative oral pressure through an intra-oral appliance, would reduce the severity of obstructive sleep apnea in a multi-center, prospective, first-night-randomized-order cross-over study. METHODS/PATIENTS: 130 patients fulfilled the entry criteria (age <75, AHI 15-55, BMI <33), and 63 entered the primary endpoint cohort (Total Sleep Time ≥4 h/night on the baseline polysomnogram and an oral negative vacuum time maintained by iNAP® ≥ 4 h/night and total sleep time ≥4 h/night during the first treatment study). 54 patients completed a second treatment sleep study at least 28 days after the first sleep study. RESULTS: Among the primary endpoint cohort (n = 63, age = 53.2 ± 11.3, BMI = 27.1 ± 2.8), 33 patients (52 %; 95 % confidence interval = 40%-64 %, p < 0.001) responded to iNAP treatment according to the Sher criteria (>50 % reduction in AHI and an AHI ≤20 events/hr). The average oxy-hemoglobin saturation increased by 1-2%, and the average percent oxygen desaturation decreased (was less severe) by 1 % while using the iNAP device. The incidence of adverse events, all self-limited, was low. The reduction in the apnea-hypopnea index was durable over the 28-day study. Patients used iNAP on average 5.6 h per night during the study period. CONCLUSION: The iNAP® Sleep Therapy System achieved a durable benefit in more than half the patients with moderate to severe obstructive sleep apnea and may be considered in patients who object to or failed continuous positive airway pressure. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02698059.

2.
Dent Mater ; 40(2): 359-369, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38143188

RESUMO

OBJECTIVES: To evaluate the effect of an additional layer of universal adhesive on the interfacial enamel/dentin-composite gap formation in relation to application mode and aging, via spectral domain optical coherence tomography (SD-OCT) and scanning electron microscopy (SEM). METHODS: In vitro class V cavities in 114 caries-free premolars were restored by applying one or two layers of a universal adhesive (Scotchbond Universal, SBU) in self-etch (se) and etch-and-rinse (er) mode or the reference adhesive OptiBond FL (OFL-er). The restorations were imaged by SD-OCT (six groups, n = 8) and SEM (n = 3) directly after filling (t1), water storage (t2, 24 h), embedding (t3), and thermo-mechanical loading (t4, TCML). The interfacial gaps were quantified using 26 parameters and analyzed using principal component analysis and linear mixed effect models. RESULTS: Gap formation at enamel and dentin was significantly influenced by the adhesive, the application mode and number of layers (p < 0.001). This was due to the influence of the SBU-er mode (p < 1e-05), which showed significantly more gap formation and a greater range of variation with double application when compared to SBU-se and OFL. The fewest interfacial gaps occurred with one or two applications of OFL-er and one layer of SBU-er. SIGNIFICANCE: Adhesive application mode and the number of adhesive layers are relevant factors in the tooth-composite bond failure. Double application worsened the adaptation of SBU to freshly prepared dentin conditioned with phosphoric acid.


Assuntos
Colagem Dentária , Cimentos Dentários , Adesivos Dentinários/química , Resinas Compostas/química , Teste de Materiais , Cimentos de Resina/química , Dentina
3.
J Clin Med ; 12(18)2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37762718

RESUMO

The effectiveness of a universal adhesive applied in three application modes for the preparation of Class V composite restorations was evaluated both clinically and by quantitative marginal analysis (QMA) over 36 months. In 50 patients, three (n = 21) or four (n = 29) non-carious cervical lesions (NCCL) were restored with Venus® Diamond Flow (Kulzer GmbH, Hanau, Germany). The adhesive iBond® Universal (iBU, Kulzer, Germany) was used in self-etch (SE), etch-and-rinse (ER), or selective-enamel-etch mode (SEE). The etch-and-rinse adhesive OptiBondTM FL served as a control (OFL, Kerr GmbH, Herzogenrath, Germany). The restorations were clinically assessed (FDI criteria) at 14 days (BL), 6, 12, 24, and 36 months. Additionally, QMA was conducted on all restorations of 11 randomly selected patients. FDI criteria and marginal gap and perfect margin were compared between and within groups and recalls using McNemar, Wilcoxon, or Mann-Whitney U-tests (α = 0.05). Starting with 12 months, cumulative failure rates were lower in iBU-SE (0.0%, p = 0.016) and iBU-ER groups (2.1%, p = 0.07) compared to OFL (16.7%). At two years, iBU-SEE also showed fewer failures (0.0% SEE vs. 34.6% OFL, p = 0.016), as did iBU-SE compared to iBU-ER after 36 months (2.2 and 19.6%, p = 0.039). From BL, the iBU-SEE group always had the fewest marginal gaps and the highest percentage of perfect margins. From BL, iBU-SEE (0%, p = 0.008) and iBU-ER (0.2%, p = 0.027) showed significantly fewer marginal gaps compared to OFL (2.5%) and more perfect margins were found with iBU-SEE starting at 6 months (p = 0.054). The SEE and ER modes ensured the most excellent marginal quality, with differences from the control appearing earlier with QMA than clinically. In restoring NCCls, iBU showed superior clinical performance over OFL, especially in modes SE and SEE.

4.
J Clin Med ; 11(23)2022 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-36498485

RESUMO

The effectiveness of a universal adhesive applied in different application modes for the preparation of Class V composite restorations was evaluated both clinically and by quantitative marginal analysis (QMA). In each of the 22 patients, four non-carious cervical lesions (NCCL) were restored with Filtek™ Supreme XTE (3M). The adhesive Scotchbond™ Universal (SBU, 3M) was applied in self-etch (SE), selective-enamel-etch (SEE) or etch-and-rinse (ER) modes. The etch-and-rinse adhesive OptiBond™ FL (OFL, Kerr) served as a control. The restorations were clinically evaluated (FDI criteria) after 14 days (BL), 6, 12, 24, and 36 months. Additionally, QMA was conducted on all restorations of 11 randomly selected patients. The FDI criteria and marginal gap were statistically compared between the groups at each recall as well as for the time periods between recalls. The cumulative failure rate was non-significantly higher in the OFL group when compared to all of the SBU groups. Marginal adaptation in the OFL and SBU-SE/ER groups was significantly decreased (BL-36 m, p: 0.004) in comparison to the SBU-SEE group (BL-36 m, p: 0.063). More marginal gaps were found in the OFL group than in the SBU-SEE (BL to 36 m, p: 0.063-0.003) and SBU-ER (24/36 m, p: 0.066/0.005) groups as well as in the SBU-SE group when compared to the SBU-SEE (12-36 m, pi ≤ 0.016) and SBU-ER (24/36 m, p: 0.055/0.001) groups. SBU-SEE performed most effectively. The clinical evaluation and QMA corresponded, yet QMA detected group differences earliest after 6 months and is thus a valuable extension to clinical evaluations.

5.
J Adhes Dent ; 24(1): 165-174, 2022 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-35416444

RESUMO

PURPOSE: To compare a self-etch and a two-step etch-and-rinse adhesive in terms of internal and marginal composite-tooth bond failure separately on enamel and dentin/cement at 36-48 months after restoration placement using optical coherence tomography (OCT). MATERIALS AND METHODS: Twenty-seven patients with two or three class V composite restorations of noncarious cervical lesions 36-48 months after placement were included. The one-step self-etch adhesive Futurabond M ([Voco] group SE, n = 25) and the two-step etch-and-rinse adhesive Solobond M ([Voco] group ER, n = 20) combined with the nanohybrid composite Amaris (Voco) were evaluated. The four-step etch-and-rinse adhesive Syntac classic combined with Tetric EvoCeram (Ivoclar Vivadent) served as the control (n = 18). Spectral-domain OCT (SD-OCT, 1310-nm center wavelength) was applied. Marginal gaps and internal interfacial adhesive defects were quantified in cross-sectional OCT images. Groups were statistically compared using the Friedman/Wilcoxon test (α = 0.05). RESULTS: In enamel, nonsignificantly different percentages of marginal gap formation and internal interfacial adhesive defects were found between the groups (pi ≥ 0.258). In dentin/cement, SE showed significantly less marginal gap formation compared to ER (p < 0.001) and control (p = 0.001), and at the internal dentin-composite interface less adhesive defects were found compared to ER (p < 0.001) and control (p = 0.003). CONCLUSION: The self-etch adhesive used in the current study appears recommendable for restoration of noncarious cervical lesions with composite.


Assuntos
Restauração Dentária Permanente , Tomografia de Coerência Óptica , Resinas Compostas/química , Estudos Transversais , Cimentos Dentários , Esmalte Dentário , Adaptação Marginal Dentária , Adesivos Dentinários/química , Humanos , Cimentos de Resina/química
6.
Am J Physiol Heart Circ Physiol ; 322(5): H742-H748, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-35275761

RESUMO

Aortic dissection and rupture are the major causes of premature death in persons with Marfan syndrome (MFS), a rare genetic disorder featuring cardiovascular, skeletal, and ocular impairments. We and others have found that obstructive sleep apnea (OSA) confers significant vascular stress in this population and may accelerate aortic disease progression. We hypothesized that D-dimer, a diagnostic biomarker for several types of vascular injury that is also elevated in persons with MFS with aortic enlargement, may be sensitive to cardiovascular stresses caused by OSA. To test this concept, we recruited 16 persons with MFS without aortic dissection and randomized them to two nights of polysomnography, without (baseline) and with OSA treatment: continuous positive airway pressure (CPAP). In addition to scoring OSA by the apnea-hypopnea index (AHI), beat-by-beat systolic BP (SBP) and pulse-pressure (PP) fluctuations were quantified. Morning blood samples were also assayed for D-dimer levels. In this cohort (male:female, 10:6; age, 36 ± 13 yr; aortic diameter, 4 ± 1 cm), CPAP eliminated OSA (AHI: 20 ± 17 vs. 3 ± 2 events/h, P = 0.001) and decreased fluctuations in SBP (13 ± 4 vs. 9 ± 3 mmHg, P = 0.011) and PP (7 ± 2 vs. 5 ± 2 mmHg, P = 0.013). CPAP also reduced D-dimer levels from 1,108 ± 656 to 882 ± 532 ng/mL (P = 0.023). Linear regression revealed a positive association between the maximum PP during OSA and D-dimer in both the unadjusted (r = 0.523, P = 0.038) and a model adjusted for contemporaneous aortic root diameter (r = 0.733, P = 0.028). Our study revealed that overnight CPAP reduces D-dimer levels commensurate with the elimination of OSA and concomitant hemodynamic fluctuations. Morning D-dimer measurements together with OSA screening might serve as predictors of vascular injury in MFS.NEW & NOTEWORTHY What is New? Surges in blood pressure caused by obstructive sleep apnea during sleep increase vascular stress and D-dimer levels in Marfan syndrome. Elevations in D-dimer can be lowered with CPAP. What is Noteworthy? D-dimer levels might serve as a marker for determining the significance of obstructive sleep apnea in persons with Marfan syndrome. D-dimer or obstructive sleep apnea screening is a potential method to identify persons with Marfan syndrome at risk for adverse cardiovascular events.


Assuntos
Síndrome de Marfan , Apneia Obstrutiva do Sono , Adulto , Pressão Sanguínea/fisiologia , Pressão Positiva Contínua nas Vias Aéreas , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio , Humanos , Masculino , Síndrome de Marfan/complicações , Síndrome de Marfan/diagnóstico , Pessoa de Meia-Idade , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/terapia , Adulto Jovem
7.
J Dent ; 119: 104068, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35192908

RESUMO

OBJECTIVES: To evaluate a universal adhesive clinically using FDI criteria and by optical coherence tomography (OCT). METHODS: In 50 patients, three or four non-carious cervical lesions (NCCL) were restored with composite (Venus® Diamond Flow, Kulzer) using iBond® Universal (iBU, Kulzer) applied in self-etch (iBU-SE, n = 50), selective-enamel-etch (iBU-SEE, n = 29) or etch-and-rinse mode (iBU-ER, n = 50) and the reference OptiBond™ FL (OFL, Kerr, n = 50). Restorations were imaged by SD-OCT. The weighted mean length of interfacial adhesive defects (AD, %) was quantified per restoration immediately after placement (t0), simultaneously with clinical assessment (FDI criteria) after 14 days (t1), 6 (t2) and 12 months (t3). Data were statistically analyzed (McNemar-/Wilcoxon-/Mann-Whitney-U test (α = 0.05), Kaplan-Meier survival curves). RESULTS: After 12 months, cumulative failure rates were lower with iBU-SE (0.0%; p = 0.016), iBU-SEE (0.0%; p = 0.125), and iBU-ER (2.1%; p = 0.070; loss t3) compared to OFL (16.7%; losses t2, t3). Generally, marginal adaptation decreased (pi < 0.001) and marginal staining increased (pi ≤ 0.031), without significant group differences (pi > 0.064). AD increased in all groups (pi < 0.001). At enamel, AD appeared more extended with iBU-SE vs. iBU-SEE (t2-t3; pi ≤ 0.005), iBU-ER (t1-t3; pi ≤ 0.051) and OFL (t0-t3; pi ≤ 0.018). At dentin/cement iBU generally caused fewer defects than OFL (t1-t3; pi ≤ 0.010) and with SE vs. ER (t2-t3; pi = 0.010). CONCLUSIONS: In NCCLs, iBU generally provides a more durable bond than OFL. Recommended mode is SEE. Clinic and OCT provided comparable results. OCT has higher statistical power, shows group differences earlier and specifically for the different hard tooth tissues. CLINICAL SIGNIFICANCE: The universal adhesive iBU was superior against the reference OFL in NCCLs. It can be recommended with SEE. Evaluation of interfacial adhesive defects by OCT seems to allow early prediction of adhesives' clinical performance.


Assuntos
Adesivos Dentinários , Tomografia de Coerência Óptica , Resinas Compostas/química , Resinas Compostas/uso terapêutico , Cimentos Dentários/uso terapêutico , Adaptação Marginal Dentária , Restauração Dentária Permanente/métodos , Adesivos Dentinários/química , Humanos , Cimentos de Resina/química
8.
J Clin Sleep Med ; 18(6): 1583-1592, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35152942

RESUMO

STUDY OBJECTIVES: Patients with Marfan syndrome (MFS) have a high risk for aortic aneurysms. They are also susceptible to sleep-disordered breathing that may expose them to highly negative intrathoracic pressures known to increase aortic transmural pressure, which may accelerate aortic dilatation. Our objective was to quantify overnight intrathoracic pressure changes during sleep in snoring patients with MFS and the therapeutic effect of continuous positive airway pressure (CPAP). METHODS: We used a questionnaire to identify self-reported snoring patients with MFS. In these patients, we monitored intrathoracic pressure using esophageal pressure (Pes) during overnight baseline and CPAP sleep studies. We defined a peak-inspiratory Pes (Pespeak-insp) < - 5 cm H2O as greater than normal and examined the distribution of Pespeak-insp during baseline and CPAP studies. RESULTS: In our sample of 23 snorers with MFS, we found that 70% of sleep breaths exhibited Pespeak-insp < -5 cm H2O, with apnea/hypopneass accounting for only 12%, suggesting prevalent stable flow-limited breathing and snoring. In a subset (n = 12) with Pes monitoring during a CPAP night, CPAP lowered the mean proportion of breaths with Pespeak-insp < -5 cm H2O from 83.7% ± 14.9% to 3.6% ± 3.0% (P < .001). In addition, contemporaneous aortic root diameter was associated with the mean Pespeak-insp during inspiratory flow-limited breathing and apneas/hypopneas (ß = -0.05, r = .675, P = .033). CONCLUSIONS: The sleep state in MFS revealed prolonged exposure to exaggerated negative inspiratory Pes, which was reversible with CPAP. Since negative intrathoracic pressure can contribute to thoracic aortic stress and aortic dilatation, snoring may be a reversible risk factor for progression of aortic pathology in MFS. CITATION: Sowho M, Jun J, Sgambati F, et al. Assessment of pleural pressure during sleep in Marfan syndrome. J Clin Sleep Med. 2022;18(6):1583-1592.


Assuntos
Síndrome de Marfan , Ronco , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Síndrome de Marfan/complicações , Polissonografia , Sono , Ronco/complicações
10.
J Clin Med ; 10(5)2021 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-33801317

RESUMO

Deep carious dentin lesions induce an immune reaction within the pulp-dentin complex, leading to the release of cytokines, which might be suitable biomarkers in pulp diagnostics. This in vivo feasibility study determines the concentration of different cytokines after selective removal of carious infected dentin (SCR). In our methodology, paired samples are obtained from 21 patients-each of them with two deep carious lesions at posterior teeth without clinical symptoms. After SCR, lesions are randomly assigned to treatment strategy: Group 1 (11 patients): Carious dentin is covered either with BiodentineTM (n = 11) or gutta-percha (n = 11) before using the adhesive OptibondTM FL. Group 2 (10 patients): The adhesives ClearfilTM SE Protect Bond (n = 10) or ClearfilTM SE Bond 2 (n = 10) are directly applied. Prepared cavities are rinsed with phosphate buffered saline containing 0.05% Tween 20 (10X) for five minutes immediately after SCR (visit 1) and eight weeks later (visit 2). Rinsing liquid is regained. Concentrations of IL-1ß, IL-6, IL-10, C-reactive protein (CRP), TNF-α, IFN-γ, TIMP-1, -2, and MMP-7, -8, -9 are assessed by customized multiplex assays, evaluated with fluorescence analyzer. Non-parametric statistical analysis (Wilcoxon, Mann-Whitney U Test, p < 0.05) is performed (SPSS 25). Our results show that concentrations of CRP, IL-1ß, IL-6, TIMP-1, -2, and MMPs were detectable. Median concentrations of CRP, IL-1ß und IL-6 were significantly higher in visit 1 (304.9, 107.4, 3.8 pg/mL), compared to visit 2 (67.8, 2.3, 0.0 pg/mL; pi < 0.001). The study revealed that the non-invasive determination of cytokines from prepared dental cavities is possible.

11.
Photodiagnosis Photodyn Ther ; 34: 102270, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33785442

RESUMO

OBJECTIVES: To evaluate different light-based caries diagnostic methods for assessment of non-cavitated initial carious lesions on smooth surfaces. METHODS: 39 participants were included. For each participant, three regions of interest (ROI) with ICDAS codes 0, 1 or 2 were defined. All ROIs (n = 117) were investigated/imaged with laser fluorescence (LF, DIAGNOdent 2095; KaVo dental GmbH), quantitative light-induced fluorescence (QLF; Biluminator 2+, Inspektor Research Systems B.V.) and spectral-domain optical coherence tomography (SD-OCT; Telesto II, Thorlabs GmbH). The values of LF, ΔF of QLF, and the lesion extent assessed by OCT were categorized. Frequency distribution of LF-/QLF- and OCT-scores was determined for each ICDAS code included. Inter- and intra-examiner reproducibility of QLF and OCT measurements were assessed by unweighted kappa coefficient (ĸ) and Wilcoxon test (α = 0.05). RESULTS: Compared with LF and QLF, OCT showed various manifestations of carious lesions for visually sound ROIs and a larger variation of caries extent in depth within the same ICDAS code groups. Intra-examiner reproducibility ranged between 0.49 and 1.00 for the QLF analysis and between 0.95 and 0.99 for the OCT analysis. Inter-examiner reproducibility ranged between 0.17 and 0.32 for the QLF analysis and between 0.65 and 0.79 for the OCT analysis. CONCLUSION: LF and QLF were insensitive to less pronounced smooth-surface lesions while OCT allowed differentiation based on the penetration depth of the carious lesions. This makes OCT a suitable method to complement conventional visual inspection in order to detect and assess (very) early lesions.


Assuntos
Cárie Dentária , Fotoquimioterapia , Cárie Dentária/diagnóstico por imagem , Suscetibilidade à Cárie Dentária , Fluorescência , Humanos , Lasers , Luz , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Reprodutibilidade dos Testes
12.
J Adhes Dent ; 23(1): 37-46, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33512114

RESUMO

PURPOSE: To assess possible correlations between clinical outcomes and SEM marginal analysis in a prospective long-term clinical study using two adhesives in incisors and canines. Materials and Methods: Thirty-five patients received class III and IV restorations with two different adhesives, either the one-step self-etch adhesive iBond Gluma inside (1-SE) or the two-step etch-and-rinse adhesive Gluma Comfort Bond (2-ER) combined with the fine particle hybrid composite Venus. The restorations were clinically evaluated (modified USPHS criteria) over 90 months. Based on resin replicas, a quantitative marginal SEM analysis was performed using the criteria "gap", "perfect margin", "overhang", and "underfilled". The results of the quantitative marginal analysis were statistically compared and related to clinical evaluations. The SEM data were analyzed statistically using the Kolmogorov-Smirnov test, Wilcoxon test, and mixed models test. Results: Of the 35 subjects at baseline, 16 (1-SE) and 17 (2-ER) were clinically re-examined after 90 months. 13 patients were included in the SEM analysis due to uninterrupted documentation over 90 months or until restoration loss. SEM analysis showed larger discriminative power between groups than did the clinical examination, but the trend was the same. Marginal analysis ("gap", "perfect margin") showed significant differences between the materials after 12 months, which clinically began to show a trend from 12 months, and were statistically verified after 48 and 90 months. "Overhang" and "underfilled" did not reveal significant differences between the systems or over time. Conclusion: SEM marginal analysis using the replication technique is a powerful tool to reveal differences between adhesives. Compared to clinical evaluation, group differences can be detected earlier, with both outcome parameters confirming each other over long observation periods.


Assuntos
Resinas Compostas , Restauração Dentária Permanente , Análise Custo-Benefício , Cimentos Dentários , Adaptação Marginal Dentária , Adesivos Dentinários , Humanos , Estudos Prospectivos , Cimentos de Resina
13.
Sleep Breath ; 25(2): 705-717, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32827122

RESUMO

BACKGROUND: In precapillary pulmonary hypertension (PH), nasal high flow therapy (NHF) may favorably alter sympathovagal balance (SVB) and sleep-related breathing through washout of anatomical dead space and alleviation of obstructive sleep apnea (OSA) due to generation of positive airway pressure. OBJECTIVES: To investigate the effects of NHF on SVB, sleep, and OSA in patients with PH, and compare them with those of positive airway pressure therapy (PAP). METHODS: Twelve patients with PH (Nice class I or IV) and confirmed OSA underwent full polysomnography, and noninvasive monitoring of SVB parameters (spectral analysis of heart rate, diastolic blood pressure variability). Study nights were randomly split into four 2-h segments with no treatment, PAP, NHF 20 L/min, or NHF 50 L/min. In-depth SVB analysis was conducted on 10-min epochs during daytime and stable N2 sleep at nighttime. RESULTS: At daytime and compared with no treatment, NHF20 and NHF50 were associated with a flow-dependent increase in peripheral oxygen saturation but a shift in SVB towards increased sympathetic drive. At nighttime, NHF20 was associated with increased parasympathetic drive and improvements in sleep efficiency, but did not alter OSA severity. NHF50 was poorly tolerated. PAP therapy improved OSA but had heterogenous effects on SVB and neutral effects on sleep outcomes. Hemodynamic effects were neutral for all interventions. CONCLUSIONS: In sleeping PH patients with OSA NHF20 but not NHF50 leads to decreased sympathetic drive likely due to washout of anatomical dead space. NHF was not effective in lowering the apnea-hypopnoea index and NHF50 was poorly tolerated.


Assuntos
Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Hipertensão Pulmonar/terapia , Oxigenoterapia/métodos , Apneia Obstrutiva do Sono/terapia , Sono/fisiologia , Idoso , Feminino , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Polissonografia , Apneia Obstrutiva do Sono/fisiopatologia , Resultado do Tratamento
14.
Odontology ; 109(1): 139-148, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32519114

RESUMO

This study aimed at evaluating the marginal and internal adaptation of low-viscosity bulk-fill composites to enamel and dentin using a self-etch or an etch-and-rinse adhesive without and with artificial ageing. Hundred and twenty-eight MOD cavities in extracted molars were assigned to eight groups (n = 16), restored with the adhesives OptiBond FL (OFL) or Xeno V+ (X) and two low-viscosity bulk-fill composites SDR or x-tra base, covered with Premise. Tetric EvoCeram Bulk Fill and Premise served as a control. n = 8 per group were subjected to prolonged water storage (180 days) and thermocycling (2500×). Scanning electron microscopy was used to determine marginal gaps (MG) and interfacial adhesive defects (IAD). There were no significant differences between composite types in 44 out of 48 (MG) or 43/48 (IAD) comparisons. More MG were observed with X than with OFL (14 out of 16 comparisons, two significant), while in 16 of 16 comparisons with X more IAD were observed (14 significant). After artificial ageing, MG generally increased (9/16 significant), compared to IAD (one significant). The performance of the investigated composite types concerning the integrity of the tooth-composites interface was comparable. Compared to the 1-step self-etch system, the bond with the 3-step etch-and-rinse adhesive was raised.


Assuntos
Materiais Dentários , Restauração Dentária Permanente , Resinas Compostas , Esmalte Dentário , Teste de Materiais , Cimentos de Resina , Viscosidade
15.
Sleep Breath ; 25(3): 1441-1451, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33263819

RESUMO

PURPOSE: In neuromuscular disorders (NMD), inspiratory muscle weakness may cause sleep-related hypoventilation requiring non-invasive ventilation (NIV). Alternatively, nasal high flow therapy (NHF) may ameliorate mild nocturnal hypercapnia (NH) through washout of anatomical dead space and generation of positive airway pressure. Ventilatory support by NIV or NHF might have favourable short-term effects on sympathovagal balance (SVB). This study comparatively investigated the effects of NHF and NIV on sleep-related breathing and SVB in NMD patients with evolving NH. METHODS: Transcutaneous CO2 (ptcCO2), peripheral oxygen saturation (SpO2), sleep outcomes and SVB (spectral analysis of heart rate, diastolic blood pressure variability) along with haemodynamic measures (cardiac index, total peripheral resistance index) were evaluated overnight in 17 patients. Polysomnographies (PSG) were randomly split into equal parts with no treatment, NIV and NHF at different flow rates (20 l/min vs. 50 l/min). In-depth analysis of SVB and haemodynamics was performed on 10-min segments of stable N2 sleep taken from each intervention. RESULTS: Compared with no treatment, NHF20 and NHF50 did not significantly change ptcCO2, SpO2 or the apnea hypopnea index (AHI). NHF50 was poorly tolerated. In contrast, NIV significantly improved both gas exchange and AHI without adversely affecting sleep. During daytime, NHF20 and NHF50 had neutral effects on ventilation and oxygenation whereas NIV improved ptcCO2 and SpO2. Effects of NIV and NHF on SVB and haemodynamics were neutral during both night and daytime. CONCLUSIONS: NHF does not correct sleep-disordered breathing in NMD patients with NH. Both NHF and NIV exert no immediate effects on SVB.


Assuntos
Pressão Sanguínea/fisiologia , Frequência Cardíaca/fisiologia , Hipercapnia/fisiopatologia , Hipercapnia/terapia , Doenças Neuromusculares/fisiopatologia , Oxigenoterapia/métodos , Sono/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ventilação não Invasiva , Polissonografia , Resultado do Tratamento
16.
J Dent ; 105: 103555, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33346060

RESUMO

OBJECTIVES: This in vivo study compared the antibacterial effect of a self-etch adhesive with and without the brominated monomer 12-methacryloyloxydodecyl-pyridinium bromide (MDPB) on carious dentin after selective caries removal. METHODS: 10 patients showing deep primary carious lesions at two posterior teeth without pulpal symptoms were included. At visit I, carious tissue was selectively removed and carious dentin was sampled with a sterile roundbur (Komet No. 18). One cavity was restored with composite (SDR, Ceram X; DENTSPLY DeTrey) using an MDPB-containing self-etch adhesive (Clearfil Protect Bond, Kuraray Noritake; PB). The other restoration served as a control (Clearfil SE Bond II, Kuraray Noritake; SE). At visit II after 8 weeks, carious dentin was sampled again. Bacterial growth in carious dentin was differentiated using microbial cultivation. Bacterial DNA from intact cells and cell-free DNA were quantified using 16S rRNA gene-based real-time PCR and the microbial community composition was analyzed by amplicon deep-sequencing. Wilcoxon test was applied for statistical analysis. RESULTS: Both treatments showed a decrease of intact bacterial cells in carious dentin at visit II compared to visit I (PB: visit I: 1.1*106, visit II: 1.7*105 (p = 0.03); SE: visit I: 1.1*107, visit II = 2.4*105 (p = 0.002)). No statistically significant reduction of cell-free bacterial DNA was detected (PB: visit I: 6.1*105, visit II: 1.6*105 (p = 0.08); SE: visit I: 5.3*105, visit II: 2.9*105 (p = 0.10)). The decrease of intact cell-derived (p = 0.371) and cell-free DNA (p = 0.455) did not differ significantly between PB and SE. Lactobacillus was most abundant within the microbial community at both visits. Alpha-diversity was not affected by treatment and samples showed high intra- and interindividual diversity. CONCLUSION AND CLINICAL SIGNIFICANCE: Both self-etch adhesives have an antibacterial effect due to a decrease of bacterial DNA after selective caries removal. However, the results do not reveal any additional antibacterial effect by MDPB. The study is registered with the German Clinical Trials Register (DRKS00011532).


Assuntos
Colagem Dentária , Cárie Dentária , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Cárie Dentária/tratamento farmacológico , Cimentos Dentários , Dentina , Adesivos Dentinários , Humanos , Teste de Materiais , RNA Ribossômico 16S , Cimentos de Resina
17.
Dent Mater ; 37(3): 423-431, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33288325

RESUMO

OBJECTIVES: In-vitro evaluation of the influence of preparation design and thickness of ceramic veneers on the interfacial bond using optical coherence tomography (OCT). METHODS: Sixty-four central incisors were randomly assigned to four preparation designs differing from no to complete dentine exposure (n = 16 each): non-prep (NP), minimal-invasive (MI, no dentine exposure), semi-invasive (SI, 50% dentine) and invasive (I, 100% dentine). Ceramic veneers (IPS InLine Veneer) of two thicknesses (0.2-0.5 mm (T1) and > 0.5-1.2 mm (T2)) were etched, silanized, and adhesively luted (Optibond FL, Variolink Veneer). After water storage (37 °C, 21d), thermocycling (2000 cycles, 5°-55 °C), and mechanical loading (2 + 1 million cycles, 50 + 100 N) specimens were imaged by spectral-domain OCT (Telesto II, Thorlabs). Adhesive defects at the ceramic-composite and tooth-composite interfaces were quantified on 35 equidistantly distributed OCT B-scans (length, %). Statistical differences were verified with Wilcoxon-/Mann-Whitney-U-test (α = 0.05). RESULTS: Adhesive defects appeared in all groups at both interfaces, albeit to differing extents (0.1 - 31.7%). NP and MI veneers showed no significant differences at the interfaces (pi > 0.05). In groups, SI and I, significantly more adhesive defects appeared at the tooth-composite compared to the veneer-composite interface (pi ≤ 0.039). The following preparation designs and veneer thicknesses showed differences (pi ≤ 0.021): Veneer-composite: NP-T1 < I-T1, MI-T1 < I-T1, I-T1 > I-T2; Tooth-composite: NP-T1 < SI-T1, NP-T1 < I-T1, NP-T2 > MI-T2, MI-T1 < SI-T1, MI-T1 < I-T1, SI-T1 < I-T1, MI-T2 < SI-T2, MI-T2 < I-T2. SIGNIFICANCE: The interface adhesion of ceramic veneers was influenced by the preparation design and the veneer thickness. A ceramic thickness of at least 0.5 mm and a preparation without exposing dentine is advantageous for the interfacial bond.


Assuntos
Porcelana Dentária , Facetas Dentárias , Cerâmica , Teste de Materiais , Cimentos de Resina , Tomografia de Coerência Óptica
18.
J Anat ; 2020 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-33289078

RESUMO

Understanding of normal fetal organ development is crucial for the evaluation of the pathogenesis of congenital anomalies. Various techniques have been used to generate imaging of fetal rat organogenesis, such as histological dissection with 3-dimensional reconstruction and scanning electron microscopy. However, these techniques did not imply quantitative measurements of developing organs (volumes, surface areas of organs). Furthermore, a partial or total destruction of the embryos prior to analysis was inevitable. Recently, micro-computed tomography (micro-CT) has been established as a novel tool to investigate embryonic development in non-dissected embryos of rodents. In this study, we used the micro-CT technique to generate 4D datasets of rat embryos aged between embryonic day 15-22 and newborns. Lungs, hearts, diaphragms, and livers were digitally segmented in order to measure organ volumes and analyze organ development as well as generate high-resolution 3D images. These data provide objective values compiling a 4D atlas of pulmonary, cardiac, diaphragmatic, and hepatic development in the fetal rat.

19.
J Clin Med ; 9(10)2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33053724

RESUMO

Caries, the world's most common chronic disease, remains a major cause of invasive restorative dental treatment. To take advantage of the diagnostic potential of optical coherence tomography (OCT) in contemporary dental prevention and treatment, an intraorally applicable spectral-domain OCT probe has been developed based on an OCT hand-held scanner equipped with a rigid 90°-optics endoscope. The probe was verified in vitro. In vivo, all tooth surfaces could be imaged with the OCT probe, except the vestibular surfaces of third molars and the proximal surface sections of molars within a "blind spot" at a distance greater than 2.5 mm from the tooth surface. Proximal surfaces of 64 posterior teeth of four volunteers were assessed by intraoral OCT, visual-tactile inspection, bitewing radiography and fiber-optic transillumination. The agreement in detecting healthy and carious surfaces varied greatly between OCT and established methods (18.2-94.7%), whereby the established methods could always be supplemented by OCT. Direct and indirect composite and ceramic restorations with inherent imperfections and failures of the tooth-restoration bond were imaged and qualitatively evaluated. The intraoral OCT probe proved to be a powerful technological approach for the non-invasive imaging of healthy and carious hard tooth tissues and gingiva as well as tooth-colored restorations.

20.
J Clin Sleep Med ; 16(4): 563-573, 2020 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-32022670

RESUMO

STUDY OBJECTIVES: The objectives were to develop and validate an algorithm for editing WatchPAT scoring and assess the accuracy in an unselected clinical population as well as age and sex substrata. METHODS: Two hundred sixty-two participants were enrolled to undergo WatchPAT simultaneously with in-lab polysomnography (PSG) recordings for developing (n = 30), optimizing (n = 62), and validating (n = 170) an algorithm to review and edit respiratory events and sleep architecture of WatchPAT recordings, which was based on visual inspection of WatchPAT signals. Apnea-hypopnea index (AHI) and sleep indices were compared with PSG-derived and automated WatchPAT indices. RESULTS: Although estimation of total sleep time (TST) was comparable between automated and manual algorithm, estimation of rapid eye movement (REM) sleep time was markedly improved with manual editing from 0.48, 23.0 min (-43.9 to 89.8) to 0.64, 18.3 min (-32.6 to 69.1) (correlation with PSG, mean difference [reference range] from PSG, respectively). Manual scoring also improved correlation and agreement with PSG AHI from 0.65, 2.5 events/h (-24.0 to 28.9) to 0.81, -4.5 events/h (-22.5 to 13.6) as well as concordance for categorical agreement of sleep-disordered breathing severity and concordance for detecting severe REM-related sleep-disordered breathing. Interscorer reliabilities were excellent for TST and AHI, while good for REM sleep time. The automated algorithm performed better in younger than in older patients, while performed similarly between men and women with respect to concordance statistics. The manual algorithm markedly improved concordances more in older patients and women than in their counterparts. CONCLUSIONS: Our manual editing algorithm improves correlation and agreement with PSG-derived sleep and breathing indices. Sex and age influence the accuracy of automated analysis and the performance of manual editing on AHI concordance.