Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Appl Lab Med ; 2022 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-35794234

RESUMO

BACKGROUND: Serological testing for SARS-CoV-2 is integral for understanding prevalence of disease, tracking of infections, confirming humoral response to vaccines, and determining timing and efficacy of boosters. The study objective was to compare the specificity of serology assays in emergency department populations across the United States in 2019 (pre-pandemic) and early 2020, incorporating an automated confirmatory assay. METHODS: Patient specimens (n = 1954) were from 4 regions in the United States: New York, NY; Milwaukee, WI; Miami, FL; and Los Angeles, CA. Specimens were tested with SARS-CoV-2 anti-spike receptor-binding domain assays: SARS-CoV-2 IgG on the Abbott Alinity i (AdviseDx SARS-Cov-2 IgG II) and Beckman Coulter Access 2 (SARS-CoV-2 IgG II), and SARS-CoV-2 IgM on the Abbott Alinity i (AdviseDx SARS-CoV-2 IgM). Reactive samples were tested with a research use only angiotensin-converting enzyme 2 binding inhibition assay (Abbott ARCHITECT) for confirmation of SARS-CoV-2 neutralizing antibodies. Assay specificity was determined and comparisons performed with Fisher's exact test. RESULTS: Overall SARS-CoV-2 IgG specificity was 99.28% (95% confidence interval, 98.80%-99.61%), 99.39% (98.93%-99.68%), and 99.44% (98.99%-99.72%) for SARS-CoV-2 IgG by Abbott and Beckman, and SARS-CoV-2 IgM, respectively. Overall agreement for the two IgG assays was 99.28% (range for the 4 sites: 98.21% to 100%). There were no specificity differences between assays or sites. CONCLUSIONS: The specificity of the serological assays evaluated in a large, diverse emergency department population was >99% and did not vary by geographical site. A confirmatory algorithm with an automated pseudo-neutralization assay allowed testing on the same specimen while reducing the false positivity rate and increasing the value of serology screening methods.

3.
J Appl Lab Med ; 2022 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-35723951

RESUMO

BACKGROUND: Serological testing for SARS-CoV-2 is integral for understanding prevalence of disease, tracking of infections, confirming humoral response to vaccines, and determining timing and efficacy of boosters. The study objective was to compare the specificity of serology assays in emergency department populations across the United States in 2019 (pre-pandemic) early 2020 incorporating an automated confirmatory assay. METHODS: Patient specimens (n = 1954) were from four regions in the United States: New York, NY; Milwaukee, WI; Miami, FL; and Los Angeles, CA. Specimens were tested with SARS-CoV-2 anti-spike receptor binding domain assays: SARS-CoV-2 IgG on the Abbott Alinity i (AdviseDx SARS-Cov-2 IgG II) and Beckman Coulter Access 2 (SARS-CoV-2 IgG II), and SARS-CoV-2 IgM on the Abbott Alinity i (AdviseDx SARS-CoV-2 IgM). Reactive samples were tested with a research use only ACE2 binding inhibition assay (Abbott ARCHITECT) for confirmation of SARS-CoV-2 neutralizing antibodies. Assay specificity was determined and comparisons performed with Fisher's Exact Test. RESULTS: Overall SARS-CoV-2 IgG specificity was 99.28% (95% confidence interval: 98.80%-99.61%), 99.39% (98.93%-99.68%), and 99.44% (98.99%-99.72%) for SARS-CoV-2 IgG by Abbott and Beckman, and SARS-CoV-2 IgM, respectively. Overall agreement for the two IgG assays was 99.28% (range for the four sites: 98.21%-100%). There were no specificity differences between assays or sites. CONCLUSIONS: The specificity of the serological assays evaluated in a large diverse emergency department population was >99% and did not vary by geographical site. A confirmatory algorithm with an automated pseudo-neutralization assay allowed testing on the same specimen while reducing the false positivity rate and increasing the value of serology screening methods.

5.
Toxicol Appl Pharmacol ; 251(3): 181-90, 2011 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-21134391

RESUMO

A variety of polymer nanoparticles (NP) are under development for imaging and therapeutic use. However, little is known about their behavior. This study examined pharmacokinetics, distribution and elimination of stable polyacrylamide (PAA) nanoparticles (~31 nm average diameter). PAA NPs and polyethylene glycol-coated PAA NPs were injected into the tail veins of healthy male rats. Blood, tissues and excreta were collected at times ranging from 5 min to 120 h and their radioactive content was quantified. A mathematical model was then applied to analyze the distribution dynamics of both NPs. Elimination from the blood could be accounted for by a quick but finite relocation to the major organs (about 20%, 0.6 to 1.3h half-lives), and a slower distribution to the carcass (about 70%, 35 to 43 h half-lives). Excreted urinary levels correlated with blood concentrations. Combined cumulative urinary and fecal output accounted for less than 6% of the dose at 120 h. Compared to five other polymeric nanoparticles, the studied particles are at the highest half-lives and Area Under the Curve (4000 to 5000%-h). These two parameters decrease by three orders of magnitude when nanoparticle size increases from the 30 nm range up to 250 nm. For similar sizes, pegylated nanoparticles are more persistent in the blood than non-pegylated ones, but this difference is much smaller in the 30 nm and relatively high dose range than above 100 nm. Persistence of PAA NPs is not associated with acute toxicity signs as measured by typical serum markers of inflammation and cellular damage.


Assuntos
Resinas Acrílicas/farmacocinética , Portadores de Fármacos/farmacocinética , Nanopartículas , Polietilenoglicóis/farmacocinética , Resinas Acrílicas/administração & dosagem , Resinas Acrílicas/toxicidade , Animais , Área Sob a Curva , Portadores de Fármacos/administração & dosagem , Portadores de Fármacos/toxicidade , Meia-Vida , Injeções Intravenosas , Masculino , Modelos Teóricos , Tamanho da Partícula , Polietilenoglicóis/administração & dosagem , Polietilenoglicóis/toxicidade , Ratos , Distribuição Tecidual , Testes de Toxicidade Aguda
6.
Neurotoxicology ; 27(1): 44-59, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16125243

RESUMO

The nitroimidazole radiosensitizer CI-1010 ((R)-alpha-[[(2-bromoethyl)-amino]methyl]-2-nitro-1H-imidazole-1-ethanol monohydrobromide) causes selective, irreversible, retinal photoreceptor apoptosis in vivo. The mouse 661 W photoreceptor cell line was used as a neuronotypic model of CI-1010-mediated retinal degeneration. Exposure to CI-1010 for 24 h induced apoptosis in 661 W cells, as determined by ultrastructural analysis, agarose electrophoresis and analysis of TUNEL-positive nuclei. CI-1010 caused a loss of viability in 661 W cells, as measured by the reduction of MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide). A clear link was established between the onset of apoptosis and activity of caspase-3 and caspase-8, prior to poly[ADP-ribose]polymerase (PARP) cleavage. Pretreatment with caspase inhibitors, ZVAD.fmk or DEVD-CHO, prevented morphological changes in most CI-1010-treated cells. Evaluation of mitochondrial inner membrane potential (Deltapsi(m)) in live 661 W cells using the fluorescent dye, tetramethylrhodamine methyl ester revealed retention of (Deltapsi(m)) until after caspase activation. Absence of cytochrome c in the cytoplasm in treated cells further supports the hypothesis of a mitochondrial-independent mechanism of cell death. Significant increase in DNA crosslinks observed in 661 W cells correlates with induction and phosphorylation of p53 at multiple serine sites. Cell cycle analysis of 661 W cells reveals a G(2) arrest in response to CI-1010-induced DNA damage and neuronal cell death. Increased protein expression of Bax, Fas, and FasL, concomitant to the loss of Bcl-xL in treated 661 W cells may be modulated by p53. This study evaluates in vitro mechanisms of CI-1010-induced cell death in photoreceptors and provides evidence in support of a p53-linked activation of caspase-3 in response to DNA damage caused by CI-1010.


Assuntos
Apoptose , Caspase 3/metabolismo , Nitroimidazóis , Células Fotorreceptoras/efeitos dos fármacos , Radiossensibilizantes , Proteína Supressora de Tumor p53/metabolismo , Animais , Ciclo Celular/efeitos dos fármacos , Linhagem Celular Transformada , Dano ao DNA , Relação Dose-Resposta a Droga , Proteína Ligante Fas/biossíntese , Proteína Ligante Fas/metabolismo , Citometria de Fluxo , Camundongos , Células Fotorreceptoras/metabolismo , Células Fotorreceptoras/ultraestrutura , Poli(ADP-Ribose) Polimerase-1 , Poli(ADP-Ribose) Polimerases/metabolismo , Fatores de Tempo , Proteína X Associada a bcl-2/biossíntese , Proteína X Associada a bcl-2/metabolismo , Proteína bcl-X/biossíntese , Proteína bcl-X/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...