Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Assunto principal
Intervalo de ano de publicação
1.
Foods ; 10(12)2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34945663

RESUMO

As microbial contamination is persistent within the food and bioindustries and foodborne infections are still a significant cause of death, the detection, monitoring, and characterization of pathogens and spoilage microorganisms are of great importance. However, the current methods do not meet all relevant criteria. They either show (i) inadequate sensitivity, rapidity, and effectiveness; (ii) a high workload and time requirement; or (iii) difficulties in differentiating between viable and non-viable cells. Flow cytometry (FCM) represents an approach to overcome such limitations. Thus, this comprehensive literature review focuses on the potential of FCM and fluorescence in situ hybridization (FISH) for food and bioindustry applications. First, the principles of FCM and FISH and basic staining methods are discussed, and critical areas for microbial contamination, including abiotic and biotic surfaces, water, and air, are characterized. State-of-the-art non-specific FCM and specific FISH approaches are described, and their limitations are highlighted. One such limitation is the use of toxic and mutagenic fluorochromes and probes. Alternative staining and hybridization approaches are presented, along with other strategies to overcome the current challenges. Further research needs are outlined in order to make FCM and FISH even more suitable monitoring and detection tools for food quality and safety and environmental and clinical approaches.

2.
Bioelectrochemistry ; 141: 107841, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34098460

RESUMO

The fundamental mechanisms of pulsed electric fields on biological cells are not yet fully elucidated, though it is apparent that membrane electroporation plays a crucial role. Little is known about treatment-chamber-specific effects, and systematic studies are scarce. Thus, the present study evaluates the (dis-)advantages of various treatment chamber designs for liquid applications at differing scales. Three chambers, namely parallel plate microfluidic (V̇: 0.1 ml/min; titanium electrodes), co-linear meso (V̇: 5.0 ml/min; stainless steel electrodes), and co-linear macro (V̇: 83.3 ml/min; stainless steel electrodes) chambers, were studied. Electroporation effects on Escherichia coli in media with 0.1-10.0 mS/cm were evaluated by plate counts and flow cytometry at 8, 16, and 20 kV/cm. For the microfluidic chamber, predominantly irreversible electroporation (2.5 logs10 reductions) was seen at 0.1 mS/cm, while high irreversible electroporation (4.2 logs10 reductions) at 10.0 mS/cm was observed for the macro chamber. The meso chamber indicated a similar trend towards increased conductivity, even though only low inactivation levels were present. Variation in conductivity and electrode configuration or area likely induces effects resulting in distinct electroporation levels, as observed for the micro and macro chamber. Suitable application scenarios, depending on targeted electroporation effects, were suggested.


Assuntos
Eletroporação/métodos , Condutividade Elétrica , Eletrodos , Escherichia coli/metabolismo