Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Clin Imaging ; 108: 110081, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38340435

RESUMO

We compared image quality of head and neck CT angiography (CTA) obtained with a photon-counting detector CT (PCD-CT), including virtual monoenergetic images and polyenergetic reconstructions, and conventional energy-integrating detectors CT (EID-CT) in three patients. PCD-CT monoenergetic reconstructions at 70 keV and lower provided excellent image quality, with improved signal-to-noise and contrast-to-noise compared to EID-CT and PCD-CT polyenergetic reconstructions. PCD-CT may enable radiation dose and iodinated contrast dose reduction for cerebrovascular imaging.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Humanos , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Imagens de Fantasmas
2.
Br J Radiol ; 97(1154): 341-352, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38308034

RESUMO

OBJECTIVES: Fat radiomic profile (FRP) was a promising imaging biomarker for identifying increased cardiac risk. We hypothesize FRP can be extended to fat regions around pulmonary veins (PV), left atrium (LA), and left atrial appendage (LAA) to investigate their usefulness in identifying atrial fibrillation (AF) and the risk of AF recurrence. METHODS: We analysed 300 individuals and grouped patients according to the occurrence and types of AF. We used receiver operating characteristic and survival curves analyses to evaluate the value of imaging biomarkers, including fat attenuation index (FAI) and FRP, in distinguishing AF from sinus rhythm and predicting post-ablation recurrence. RESULTS: FRPs from AF-relevant fat regions showed significant performance in distinguishing AF and non-AF with higher AUC values than FAI (peri-PV: FRP = 0.961 vs FAI = 0.579, peri-LA: FRP = 0.923 vs FAI = 0.575, peri-LAA: FRP = 0.900 vs FAI = 0.665). FRPs from peri-PV, peri-LA, and peri-LAA were able to differentiate persistent and paroxysmal AF with AUC values of 0.804, 0.819, and 0.694. FRP from these regions improved AF recurrence prediction with an AUC of 0.929, 0.732, and 0.794. Patients with FRP cut-off values of ≥0.16, 0.38, and 0.26 had a 7.22-, 5.15-, and 4.25-fold higher risk of post-procedure recurrence, respectively. CONCLUSIONS: FRP demonstrated potential in identifying AF, distinguishing AF types, and predicting AF recurrence risk after ablation. FRP from peri-PV fat depot exhibited a strong correlation with AF. Therefore, evaluating epicardial fat using FRP was a promising approach to enhance AF clinical management. ADVANCES IN KNOWLEDGE: The role of epicardial adipose tissue (EAT) in AF had been confirmed, we focussed on the relationship between EAT around pulmonary arteries and LAA in AF which was still unknown. Meanwhile, we used the FRP to excavate more information of EAT in AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Angiografia por Tomografia Computadorizada , Tecido Adiposo Epicárdico , Radiômica , Átrios do Coração/diagnóstico por imagem , Recidiva , Ablação por Cateter/métodos
3.
J Thorac Imaging ; 39(2): 93-100, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37889562

RESUMO

PURPOSE: To evaluate a novel deep learning (DL)-based automated coronary labeling approach for structured reporting of coronary artery disease according to the guidelines of the Society of Cardiovascular Computed Tomography (CT) on coronary CT angiography (CCTA). PATIENTS AND METHODS: A retrospective cohort of 104 patients (60.3 ± 10.7 y, 61% males) who had undergone prospectively electrocardiogram-synchronized CCTA were included. Coronary centerlines were automatically extracted, labeled, and validated by 2 expert readers according to Society of Cardiovascular CT guidelines. The DL algorithm was trained on 706 radiologist-annotated cases for the task of automatically labeling coronary artery centerlines. The architecture leverages tree-structured long short-term memory recurrent neural networks to capture the full topological information of the coronary trees by using a two-step approach: a bottom-up encoding step, followed by a top-down decoding step. The first module encodes each sub-tree into fixed-sized vector representations. The decoding module then selectively attends to the aggregated global context to perform the local assignation of labels. To assess the performance of the software, percentage overlap was calculated between the labels of the algorithm and the expert readers. RESULTS: A total number of 1491 segments were identified. The artificial intelligence-based software approach yielded an average overlap of 94.4% compared with the expert readers' labels ranging from 87.1% for the posterior descending artery of the right coronary artery to 100% for the proximal segment of the right coronary artery. The average computational time was 0.5 seconds per case. The interreader overlap was 96.6%. CONCLUSIONS: The presented fully automated DL-based coronary artery labeling algorithm provides fast and precise labeling of the coronary artery segments bearing the potential to improve automated structured reporting for CCTA.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Aprendizado Profundo , Masculino , Humanos , Feminino , Angiografia por Tomografia Computadorizada/métodos , Inteligência Artificial , Estudos Retrospectivos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Doença da Artéria Coronariana/diagnóstico por imagem
4.
Pol J Radiol ; 88: e423-e429, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37808170

RESUMO

Purpose: Left atrial calcification (LAC), a primarily radiologic diagnosis, has been associated with rheumatic heart disease (RHD) and rheumatic fever (RF). However, left atrial calcification continues to be observed despite a significant decrease in the prevalence of rheumatic heart disease. The purpose of this study was to investigate other possible etiologies of left atrial calcification. Material and methods: This retrospective, observational single-center study included patients from 2017 to 2022 identified as having left atrial calcification as well as age- and sex-matched controls. The prevalence of rheumatic heart disease, atrial ablation, and mitral valve disease was compared, and odds ratios were calculated for each independent variable. Results: Sixty-two patients with left atrial calcifications were included and compared with 62 controls. 87.1% of patients in the left atrial calcifications cohort had a history of atrial fibrillation compared with 21% in the control cohort (p < 0.001). 16.1% of patients in the calcifications cohort presented a history of rheumatic fever compared with zero in the control cohort (p = 0.004). 66.1% of the left atrial calcifications cohort had a history of atrial ablation compared with 6.5% of the control group (p < 0.001). The odds ratio for left atrial calcification was 19.0 vs. 4.8 for rheumatic fever (comparative odds = 4.0 for atrial ablation vs. rheumatic fever). Multivariable log model found atrial ablation to explain 79.8% of left atrial calcifications identified. Conclusions: Our study found a 4-fold higher association between history of atrial ablation and left atrial calcification compared with rheumatic heart disease, suggesting a potential shift in etiology.

5.
Radiol Clin North Am ; 61(6): 995-1009, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37758366

RESUMO

Dual-energy computed tomography (DECT) acquires images using two energy spectra and offers a variation of reconstruction techniques for improved cardiac imaging. Virtual monoenergetic images decrease artifacts improving coronary plaque and stent visualization. Further, contrast attenuation is increased allowing significant reduction of contrast dose. Virtual non-contrast reconstructions enable coronary artery calcium scoring from contrast-enhanced scans. DECT provides advanced plaque imaging with detailed analysis of plaque components, indicating plaque stability. Extracellular volume assessment using DECT offers noninvasive detection of myocardial fibrosis. This review aims to outline the current cardiac applications of DECT, summarize recent literature, and discuss their findings.


Assuntos
Coração , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
6.
Acta Radiol ; 64(10): 2722-2730, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37649280

RESUMO

BACKGROUND: Detecting occlusions of coronary artery bypass grafts using non-contrast computed tomography (CT) series is understudied and underestimated. PURPOSE: To evaluate morphological findings for the diagnosis of chronic coronary artery bypass graft occlusion on non-contrast CT and investigate performance statistics for potential use cases. MATERIAL AND METHODS: Seventy-three patients with coronary artery bypass grafts who had CT angiography of the chest (non-contrast and arterial phases) were retrospectively included. Two readers applied pre-set morphologic findings to assess the patency of a bypass graft on non-contrast series. These findings included vessel shape (linear-band like), collapsed lumen and surgical graft marker without a visible vessel. Performance was tested using the simultaneously acquired arterial phase series as the ground truth. RESULTS: The per-patient diagnostic accuracy for occlusion was 0.890 (95% confidence interval = 0.795-0.951). Venous grafts overall had an 88% accuracy. None of the left internal mammary artery to left anterior descending artery arterial graft occlusions were detected. The negative likelihood ratio for an occluded graft that is truly patent was 0.121, demonstrating a true post-test probability of 97% for identifying a patent graft as truly patent given a prevalence of 20% occlusion at a median 8.4 years post-surgery. Neither years post-surgery, nor number of vessels was associated with a significant decrease in reader accuracy. CONCLUSION: Evaluation of coronary bypass grafts for chronic occlusion on non-contrast CT based off vessel morphology is feasible and accurate for venous grafts. Potential use cases include low-intermediate risk patients with chest pain or shortness of breath for whom non-contrast CT was ordered, or administration of iodine-based contrast is contraindicated.


Assuntos
Ponte de Artéria Coronária , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Angiografia Coronária/métodos , Grau de Desobstrução Vascular , Sensibilidade e Especificidade , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Oclusão de Enxerto Vascular/diagnóstico por imagem
7.
Clin Imaging ; 100: 24-29, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37167806

RESUMO

RATIONALE: Single-photon-emission-computerized-tomography/computed-tomography(SPECT/CT) is commonly used for pulmonary disease. Scant work has been done to determine ability of AI for secondary findings using low-dose-CT(LDCT) attenuation correction series of SPECT/CT. METHODS: 120 patients with ventilation-perfusion-SPECT/CT from 9/1/21-5/1/22 were included in this retrospective study. AI-RAD companion(VA10A,Siemens-Healthineers, Erlangen, Germany), an ensemble of deep-convolutional-neural-networks was evaluated for the detection of pulmonary nodules, coronary artery calcium, aortic ectasia/aneurysm, and vertebral height loss. Accuracy, sensitivity, specificity was measured for the outcomes. Inter-rater reliability were measured. Inter-rater reliability was measured using the intraclass correlation coefficient (ICC) by comparing the number of nodules identified by the AI to radiologist. RESULTS: Overall per-nodule accuracy, sensitivity, and specificity for detection of lung nodules were 0.678(95%CI 0.615-0.732), 0.956(95%CI 0.900-0.985), and 0.456(95%CI 0.376-0.543), respectively, with an intraclass correlation coefficient (ICC) between AI and radiologist of 0.78(95%CI 0.71-0.83). Overall per-patient accuracy for AI detection of coronary artery calcium, aortic ectasia/aneurysm, and vertebral height loss was 0.939(95%CI 0.878-0.975), 0.974(95%CI 0.925-0.995), and 0.857(95%CI 0.781-0.915), respectively. Sensitivity for coronary artery calcium, aortic ectasia/aneurysm, and vertebral height loss was 0.898(95%CI 0.778-0.966), 1 (95%CI 0.958-1), and 1 (95%CI 0.961-1), respectively. Specificity for coronary artery calcium, aortic ectasia/aneurysm, and vertebral height loss was 0.969(95% CI 0.893-0.996), 0.897 (95% CI 0.726-0.978), and 0.346 (95% CI 0.172-0.557), respectively. CONCLUSION: AI ensemble was accurate for coronary artery calcium and aortic ectasia/aneurysm, while sensitive for aortic ectasia/aneurysm, lung nodules and vertebral height loss on LDCT attenuation correction series of SPECT/CT.


Assuntos
Inteligência Artificial , Cálcio , Humanos , Estudos Retrospectivos , Dilatação Patológica , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Pulmão , Perfusão
8.
Acad Radiol ; 29(8): 1178-1188, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35610114

RESUMO

RATIONALE AND OBJECTIVES: The burden of coronavirus disease 2019 (COVID-19) airspace opacities is time consuming and challenging to quantify on computed tomography. The purpose of this study was to evaluate the ability of a deep convolutional neural network (dCNN) to predict inpatient outcomes associated with COVID-19 pneumonia. MATERIALS AND METHODS: A previously trained dCNN was tested on an external validation cohort of 241 patients who presented to the emergency department and received a chest computed tomography scan, 93 with COVID-19 and 168 without. Airspace opacity scoring systems were defined by the extent of airspace opacity in each lobe, totaled across the entire lungs. Expert and dCNN scores were concurrently evaluated for interobserver agreement, while both dCNN identified airspace opacity scoring and raw opacity values were used in the prediction of COVID-19 diagnosis and inpatient outcomes. RESULTS: Interobserver agreement for airspace opacity scoring was 0.892 (95% CI 0.834-0.930). Probability of each outcome behaved as a logistic function of the opacity scoring (25% intensive care unit admission at score of 13/25, 25% intubation at 17/25, and 25% mortality at 20/25). Length of hospitalization, intensive care unit stay, and intubation were associated with larger airspace opacity score (p = 0.032, 0.039, 0.036, respectively). CONCLUSION: The tested dCNN was highly predictive of inpatient outcomes, performs at a near expert level, and provides added value for clinicians in terms of prognostication and disease severity.


Assuntos
COVID-19 , Aprendizado Profundo , Algoritmos , COVID-19/diagnóstico por imagem , Teste para COVID-19 , Humanos , Pacientes Internados , Pulmão/diagnóstico por imagem , Morbidade , Estudos Retrospectivos , SARS-CoV-2 , Tomografia Computadorizada por Raios X/métodos
9.
J Imaging ; 8(2)2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35200737

RESUMO

Ischemic chronic cardiomyopathy (ICC) is still one of the most common cardiac diseases leading to the development of myocardial ischemia, infarction, or heart failure. The application of several imaging modalities can provide information regarding coronary anatomy, coronary artery disease, myocardial ischemia and tissue characterization. In particular, coronary computed tomography angiography (CCTA) can provide information regarding coronary plaque stenosis, its composition, and the possible evaluation of myocardial ischemia using fractional flow reserve CT or CT perfusion. Cardiac magnetic resonance (CMR) can be used to evaluate cardiac function as well as the presence of ischemia. In addition, CMR can be used to characterize the myocardial tissue of hibernated or infarcted myocardium. Echocardiography is the most widely used technique to achieve information regarding function and myocardial wall motion abnormalities during myocardial ischemia. Nuclear medicine can be used to evaluate perfusion in both qualitative and quantitative assessment. In this review we aim to provide an overview regarding the different noninvasive imaging techniques for the evaluation of ICC, providing information ranging from the anatomical assessment of coronary artery arteries to the assessment of ischemic myocardium and myocardial infarction. In particular this review is going to show the different noninvasive approaches based on the specific clinical history of patients with ICC.

10.
Magn Reson Imaging Clin N Am ; 27(2): 243-262, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30910096

RESUMO

Prevalence of patients with congenital heart disease (CHD) is rapidly increasing due to continuous advancements in diagnostic techniques and medical or surgical treatment approaches. Along with cardiac computed tomography angiography, cardiac magnetic resonance (CMR) serves as a fundamental imaging modality for pre-surgical planning in patients with CHD, as CMR allows for the evaluation of cardiac and great vessel anatomy, biventricular function, flow dynamics, and tissue characterization. This information is essential for risk-assessment and optimal timing of surgical interventions. This article discusses the current role of pediatric cardiac MR imaging as a practical preoperative assessment tool in the pediatric population.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cuidados Pré-Operatórios/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Coração/diagnóstico por imagem , Humanos , Lactente , Masculino
12.
Radiol Clin North Am ; 56(4): 521-534, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29936945

RESUMO

Dual energy computed tomography is becoming increasingly widespread in clinical practice. It can expand on the traditional density-based data achievable with single energy computed tomography by adding novel applications to help reach a more accurate diagnosis. The implementation of this technology in cardiothoracic vascular imaging allows for improved image contrast, metal artifact reduction, generation of virtual unenhanced images, virtual calcium subtraction techniques, cardiac and pulmonary perfusion evaluation, and plaque characterization. The improved diagnostic performance afforded by dual energy computed tomography is not associated with an increased radiation dose. This review provides an overview of dual energy computed tomography cardiothoracic vascular applications.


Assuntos
Cardiopatias/diagnóstico por imagem , Pneumopatias/diagnóstico por imagem , Artefatos , Vasos Coronários/diagnóstico por imagem , Coração/diagnóstico por imagem , Humanos , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X
13.
Acad Radiol ; 24(1): 30-37, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28029558

RESUMO

RATIONALE AND OBJECTIVES: Despite ongoing technical refinements, coronary computed tomography angiography (cCTA) remains challenging in its diagnostic value by electrocardiographic (ECG) misregistration and motion artifacts, which commonly occur in patients with atrial fibrillation and high or irregular heart rates. The aim of this study was to evaluate the radiation dose and the number of inconclusive coronary segments at cCTA using retrospective ECG gating at 100 and 70 kV. MATERIALS AND METHODS: With institutional review board approval, 154 patients (median age 54 years, 98 men) with high or irregular heart rate prospectively underwent retrospectively ECG-gated cCTA without tube current modulation on a third-generation dual-source computed tomography (DSCT) system at 70 kV (n = 103) or on a second-generation DSCT system at 100 kV (n = 51). Images were reconstructed in best diastolic phase (BDP), best systolic phase (BSP), and in all phases (APs) at 10% intervals across the R-R cycle. Objective and subjective image qualities were evaluated as well as the presence of motion artifacts with the three different reconstruction approaches. RESULTS: The mean heart rate was 93 ± 16 bpm. The mean effective radiation dose was 4.5 mSv for 70 kV compared to 8.4 mSv for 100 kV (P < 0.05). At BDP reconstruction, 71% (n = 110) of the patients showed motion artifacts in one or more coronary segments. At BSP reconstruction, the number of patients with motion artifacts decreased to 37% (n = 57). In contrast, if images were reconstructed with the AP approach, all vessels and coronary segments were evaluable with both cCTA protocols. CONCLUSIONS: Retrospectively ECG-gated cCTA at 70 kV results in 52% decreased radiation dose. Further using the AP algorithm allowed for diagnostic evaluation of all coronary segments for stenosis, in contrast to BDP or BSP phase alone.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/normas , Angiografia Coronária/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
14.
J Cardiovasc Comput Tomogr ; 9(3): 215-24, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25843243

RESUMO

BACKGROUND: Both low tube voltage and sinogram-affirmed iterative reconstruction (IR) techniques hold promise to decrease radiation dose at coronary CT angiography (CCTA). The increased iodine contrast at low tube voltage allows for minimizing iodine load. OBJECTIVE: To assess the effect of reduced x-ray tube voltage, low iodine concentration contrast medium and IR on image quality and radiation dose at CCTA. METHODS: Two hundred thirty-one consecutive patients with suspected coronary artery disease were enrolled in this prospective, multicenter trial and randomized to 1 of 2 dual-source CCTA protocols: 120-kVp with 370 mgI/mL iopromide or iopamidol (n = 116; 44 women; 55.3 ± 9.8 years) or 100 kVp with 270 mgI/mL iodixanol (n = 115; 48 women; 54.2 ± 10.4 years). Reconstruction was performed with filtered back projection and IR. Attenuation, image noise, signal-to-noise ratio, and contrast-to-noise ratio were measured and image quality scored. Size-specific dose estimates and effective doses were calculated. RESULTS: There were no significant differences in mean arterial attenuation (406.6 ± 76.7 vs 409.7 ± 65.2 Hounsfield units; P = .739), image noise (18.7 ± 3.8 vs 17.9 ± 3.4 Hounsfield units; P = .138), signal-to-noise ratio (22.5 ± 5.4 vs 23.7 ± 6.1; P = .126), contrast-to-noise ratio (17.5 ± 5.5 vs 18.3 ± 6.1; P = .286), or image quality scores (4.1 ± 0.9 vs 4.0 ± 0.9; P > .05) between 120-kVp filtered back projection-reconstructed and 100-kVp IR-reconstructed series. Mean iodine dose was 26.5% lower (18.3 ± 0.5 vs 24.9 ± 0.9 g; P < .0001), mean size-specific dose estimate was 35.1% lower (17.9 ± 6.6 vs 27.5 ± 8.2 mGy; P < .0001), and effective dose was 34.9% lower (2.3 ± 1.0 vs 3.5 ± 1.1 mSv; P < .0001) with the 100 kVp compared with the 120-kVp protocol, respectively. CONCLUSION: Using low x-ray tube voltage and IR allows for decreasing the iodine load and effective radiation dose at CCTA while maintaining image quality.


Assuntos
Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Iohexol/análogos & derivados , Iopamidol/administração & dosagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , China , Feminino , Humanos , Iohexol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Razão Sinal-Ruído
15.
Pediatr Radiol ; 44(9): 1158-68; quiz 1155-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25142330

RESUMO

Pulmonary venous anomalies comprise a wide spectrum of anatomical variations and their clinical presentations may vary from the relatively benign single partial anomalous pulmonary venous connection (PAPVC) to the critical obstructed total anomalous pulmonary venous connection (TAPVC). We briefly review the common anomalies encountered, while highlighting the utility that computed tomographic angiography (CTA) provides for this spectrum of extracardiac vascular malformations and connections. CTA has established itself as an invaluable imaging modality in these patients. A detailed knowledge of the CTA imaging findings in pulmonary venous anomalies is crucial to guide clinical decision-making in these patients.


Assuntos
Angiografia/métodos , Veias Pulmonares/anormalidades , Veias Pulmonares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Malformações Vasculares/diagnóstico por imagem , Humanos , Recém-Nascido , Síndrome de Cimitarra/diagnóstico por imagem
16.
Am Heart J ; 159(5): 911-8, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20435204

RESUMO

BACKGROUND: Professional, long-term physical training is associated with cardiac morphologic and functional changes that depend on the type of exercise performed. So far, the specific effect of soccer training on cardiac morphology has not been investigated with cardiac magnetic resonance imaging (CMRI). We sought to use CMRI to study left ventricular (LV) and right ventricular (RV) morphologic and functional adaptations in professional soccer players. METHODS: Twenty-nine male professional soccer players (mean age 24.6 +/- 3.9 years, range 18-31 years) in different playing positions and 29 nonathlete male controls (27.0 +/- 3.7 years, 21-34 years) underwent CMRI. Electrocardiographic-gated steady-state free-precession cine CMRI was used to measure myocardial mass (MM), end-diastolic volume (EDV) and end-systolic volume, stroke volume (SV), ejection fraction, and cardiac index at rest. We calculated the ventricular remodeling index (RI) to describe the pattern of cardiac hypertrophy. RESULTS: Ventricular volume and mass indices were significantly (P < .001) higher in athletes. LVEDV and RVEDV on MRI was above normal in 27/29 athletes. There was a strong positive correlation between EDV and myocardial mass (P < .01). The LVRI and RVRI were similar (0.73 +/- 0.1 g/mL; 0.22 +/- 0.01 g/mL) to that of controls (0.71 +/- 0.1 g/mL; 0.22 +/- 0.01 g/mL). No significant differences were observed for LV ejection fraction and cardiac index. Neither the comparison of athletes in different playing positions nor the comparison of younger and older players revealed statistically significant differences. CONCLUSION: Cardiac magnetic resonance imaging measurements enable studying the mechanisms of LV and RV adaptation in professional soccer players and reflect the ventricular response to combined endurance and strength based training.


Assuntos
Ventrículos do Coração/anatomia & histologia , Imagem Cinética por Ressonância Magnética , Futebol/fisiologia , Função Ventricular , Adaptação Fisiológica , Adolescente , Adulto , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Tamanho do Órgão , Resistência Física/fisiologia , Volume Sistólico , Adulto Jovem
17.
Eur Radiol ; 17(4): 1118-24, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17031454

RESUMO

We present the first cadavic study results concerning the feasibility of the use of an MR-guided assistance system, Innomotion (Innomedic, Herxheim, Germany), for accurate and consistent placement of percutaneous needles in the prostate gland. The MR-compatible assistance system consists of a C-arch, guiding arm and application module (AMO). T1-weighted fast low angle shot (FLASH) 2-D-GRE sequence (TR/TE=110/4 ms) and T2-weighted turbo spin-echo (TSE)-sequences (TR/TE=3200/97 ms) in transversal orientation were used for the monitoring of the punction of the prostate gland. Planning and control of the intervention is to be made outside the scanner room on a desktop computer that receives DICOM images from the scanner. Servopneumatic drives move the AMO to the insertion point. The physician has to introduce the punction needle manually. The mean deviation of the needle tip to the target in a gel phantom was 0.35 mm. An accurate punction of the prostate gland can easily be performed using this system with a transgluteal access. The T2-weighted images are superior for the evaluation of the prostate anatomy and the needle position during the interventions. In conclusion, our preliminary results indicate that this MR-guided assistance system is suitable for an accurate transgluteal needle placement in the prostate.


Assuntos
Biópsia por Agulha/métodos , Nádegas , Imageamento por Ressonância Magnética , Neoplasias da Próstata/patologia , Automação , Biópsia por Agulha/instrumentação , Cadáver , Estudos de Viabilidade , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...