Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 188
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38752971

RESUMO

BACKGROUND: The safety profile of transcatheter tricuspid valve (TTV) repair techniques is well established, but residual tricuspid regurgitation (TR) remains a concern. OBJECTIVES: The authors sought to assess the impact of residual TR severity post-TTV repair on survival. METHODS: We evaluated the survival rate at 2 years of 613 patients with severe isolated functional TR who underwent TTV repair in TRIGISTRY according to the severity of residual TR at discharge using a 3-grade (mild, moderate, and severe) or 4-grade scheme (mild, mild to moderate, moderate to severe, and severe). RESULTS: Residual TR was none/mild in 33%, moderate in 52%, and severe in 15%. The 2-year adjusted survival rates significantly differed between the 3 groups (85%, 70%, and 44%, respectively; restricted mean survival time [RMST]: P = 0.0001). When the 319 patients with moderate residual TR were subdivided into mild to moderate (n = 201, 33%) and moderate to severe (n = 118, 19%), the adjusted survival rate was also significantly different between groups (85%, 80%, 55%, and 44%, respectively; RMST: P = 0.001). Survival was significantly lower in patients with moderate to severe residual TR compared to patients with mild to moderate residual TR (P = 0.006). No difference in survival rates was observed between patients with no/mild and mild to moderate residual TR (P = 0.67) or between patients with moderate to severe and severe residual TR (P = 0.96). CONCLUSIONS: The moderate residual TR group was heterogeneous and encompassed patients with markedly different clinical outcomes. Refining TR grade classification with a more granular 4-grade scheme improved outcome prediction. Our results highlight the importance of achieving a mild to moderate or lower residual TR grade during TTV repair, which could define a successful intervention.

2.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599688

RESUMO

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Estudos Multicêntricos como Assunto , Sistema de Registros
3.
Int J Cardiol ; 405: 131934, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38437953

RESUMO

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.


Assuntos
Cateterismo Cardíaco , Sistema de Registros , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Masculino , Feminino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Idoso , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Pessoa de Meia-Idade , Ecocardiografia/métodos
4.
Eur J Heart Fail ; 25(12): 2243-2251, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37905381

RESUMO

AIM: Functional or secondary tricuspid regurgitation (STR) is the most common phenotype of tricuspid regurgitation (TR) with atrial STR (ASTR) and ventricular STR (VSTR) being recently identified as two distinct entities. Data on tricuspid transcatheter edge-to-edge repair (T-TEER) in patients with STR according to phenotype (i.e. ASTR vs. VSTR) are lacking. The aim of this study was to assess characteristics and outcomes of patients with ASTR versus VSTR undergoing T-TEER. METHODS AND RESULTS: Patients with STR undergoing T-TEER were selected from the Transcatheter Tricuspid Valve Therapies (TriValve) registry. ASTR was defined by (i) left ventricular ejection fraction ≥50%, (ii) atrial fibrillation, and (iii) systolic pulmonary artery pressure <50 mmHg. Patients not matching these criteria were classified as VSTR. Patients with primary TR and cardiac implantable electronic device were excluded. Key endpoints included procedural success and survival at follow-up. A total of 298 patients were enrolled in the study: 65 (22%) with ASTR and 233 (78%) with VSTR. Procedural success was similar in the two groups (80% vs. 83% for ASTR vs. VSTR, p = 0.56) and TEER was effective in reducing TR in both groups (from 97% of patients with baseline TR ≥3+ to 23% in ASTR and to 15% in VSTR, all p = 0.001). At 12-month follow-up, survival was significantly higher in the ASTR versus VSTR cohort (91% vs. 72%, log-rank p = 0.02), with VSTR being an independent predictor of mortality at multivariable analysis (hazard ratio 4.75). CONCLUSIONS: In a real-world, multicentre registry, T-TEER was effective in reducing TR grade in both ASTR and VSTR. At 12-month follow-up, ASTR showed better survival than VSTR.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Volume Sistólico , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/etiologia , Função Ventricular Esquerda , Sistema de Registros
5.
JACC Cardiovasc Interv ; 16(16): 1974-1985, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37648345

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with pure severe native aortic valve regurgitation (NAVR) has been associated with suboptimal results. The available evidence concerns mostly outdated transcatheter heart valves (THVs). OBJECTIVES: The aim of this study was to investigate the performance of new-generation THVs in patients treated for pure severe NAVR. METHODS: The PANTHEON (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve) study retrospectively included patients who underwent TAVR with currently available devices (both self-expanding [SE] and balloon expandable [BE]) for severe NAVR. Technical and device success rates as well as a composite of all-cause mortality and heart failure rehospitalization at 1 year were evaluated. The rate and clinical consequences of acute transcatheter valve embolization or migration (TVEM) were also considered. RESULTS: A total of 201 patients were included. Overall technical and device success rates were 83.6% and 76.1%, respectively, and did not differ between SE and BE devices. These figures were due mostly to TVEM occurrence (14.6% vs 16.1%; P = 0.47) and residual moderate or greater aortic regurgitation (9.2% vs 10.1%; P = 0.87). Patients who experienced TVEM compared with those without TVEM had a significantly higher incidence of the composite endpoint at 1 year (25.7% vs 15.8%; P = 0.05). CONCLUSIONS: Despite improved THV platforms and techniques, TAVR for pure severe NAVR remains a challenging procedure, with significant risk for TVEM. SE and BE platforms demonstrated comparable performance in this setting. (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve [PANTHEON]; NCT05319171).


Assuntos
Insuficiência da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
6.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37480891

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Incidência , Bloqueio de Ramo , Prognóstico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial
8.
EuroIntervention ; 19(5): e432-e441, 2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37103779

RESUMO

BACKGROUND: The real-world outcomes of the use of the BASILICA (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction) transcatheter technique in Europe have not been described. AIMS: We sought to evaluate the procedural and one-year outcomes of BASILICA in patients at high risk for coronary artery obstruction (CAO) undergoing transcatheter aortic valve implantation (TAVI) in a multicentre European registry (EURO-BASILICA). METHODS: Seventy-six patients undergoing BASILICA and TAVI at ten European centres were included. Eighty-five leaflets were identified as targets for BASILICA due to high risk for CAO. The updated Valve Academic Research Consortium 3 (VARC-3) definitions were used to determine prespecified endpoints of technical and procedural success and adverse events up to one year. RESULTS: Treated aortic valves included native (5.3%), surgical bioprosthetic (92.1%) and transcatheter valves (2.6%). Double BASILICA (for both left and right coronary cusps) was performed in 11.8% of patients. Technical success with BASILICA was achieved in 97.7% and resulted in freedom from any target leaflet-related CAO in 90.6% with a low rate of complete CAO (2.4%). Target leaflet-related CAO occurred significantly more often in older and stentless bioprosthetic valves and with higher implantation levels of transcatheter heart valves. Procedural success was 88.2%, and freedom from VARC-3-defined early safety endpoints was 79.0%. One-year survival was 84.2%; 90.5% of patients were in New York Heart Association Functional Class I/II. CONCLUSIONS: EURO-BASILICA is the first multicentre study evaluating the BASILICA technique in Europe. The technique appeared feasible and effective in preventing TAVI-induced CAO, and one-year clinical outcomes were favourable. The residual risk for CAO requires further study.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Oclusão Coronária , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Resultado do Tratamento , Desenho de Prótese , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Oclusão Coronária/cirurgia , Estenose da Valva Aórtica/cirurgia
9.
Artigo em Inglês | MEDLINE | ID: mdl-36948892

RESUMO

BACKGROUND: Data regarding the impact of the tricuspid valve gradient (TVG) after tricuspid transcatheter edge-to-edge repair (TEER) are scarce. OBJECTIVES: This study sought to evaluate the association between the mean TVG and clinical outcomes among patients who underwent tricuspid TEER for significant tricuspid regurgitation. METHODS: Patients with significant tricuspid regurgitation who underwent tricuspid TEER within the TriValve (International Multisite Transcatheter Tricuspid Valve Therapies) registry were divided into quartiles based on the mean TVG at discharge. The primary endpoint was the composite of all-cause mortality and heart failure hospitalization. Outcomes were assessed up to the 1-year follow-up. RESULTS: A total of 308 patients were included from 24 centers. Patients were divided into quartiles of the mean TVG as follows: quartile 1 (n = 77), 0.9 ± 0.3 mm Hg; quartile 2 (n = 115), 1.8 ± 0.3 mm Hg; quartile 3 (n = 65), 2.8 ± 0.3 mm Hg; and quartile 4 (n = 51), 4.7 ± 2.0 mm Hg. The baseline TVG and the number of implanted clips were associated with a higher post-TEER TVG. There was no significant difference across TVG quartiles in the 1-year composite endpoint (quartiles 1-4: 35%, 30%, 40%, and 34%, respectively; P = 0.60) or the proportion of patients in New York Heart Association class III to IV at the last follow-up (P = 0.63). The results were similar after adjustment for clinical and echocardiographic characteristics (composite endpoint quartile 4 vs quartile 1-quartile 3 adjusted HR: 1.05; 95% CI: 0.52-2.12; P = 0.88) or exploring post-TEER TVG as a continuous variable. CONCLUSIONS: In this retrospective analysis of the TriValve registry, an increased discharge TVG was not significantly associated with adverse outcomes after tricuspid TEER. These findings apply for the explored TVG range and up to the 1-year follow-up. Further investigations on higher gradients and longer follow-up are needed to better guide the intraprocedural decision-making process.

10.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649387

RESUMO

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Tempo , Resultado do Tratamento , Sistema de Registros , Desenho de Prótese , Fatores de Risco
11.
Eur Heart J ; 44(10): 822-832, 2023 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-36445158

RESUMO

AIMS: The impact of sexuality in patients with significant tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve intervention (TTVI) is unknown. The aim of this study was to investigate sex-specific outcomes in patients with significant TR treated with TTVI vs. medical therapy alone. METHODS AND RESULTS: The Transcatheter Tricuspid Valve Therapies (TriValve) registry collected data on patients with significant TR from 24 centres who underwent TTVI from 2016 to 2021. A control cohort was formed by medically managed patients with ≥severe isolated TR diagnosed in 2015-18. The primary endpoint was freedom from all-cause mortality. Secondary endpoints were heart failure (HF) hospitalization, New York Heart Association (NYHA) functional status, and TR severity. One-year outcomes were assessed for the TriValve cohort and compared with the control cohort with the inverse probability of treatment weighting (IPTW). A total of 556 and 2072 patients were included from the TriValve and control groups, respectively. After TTVI, there was no difference between women and men in 1-year freedom from all-cause mortality 80.9% vs. 77.9%, P = 0.56, nor in HF hospitalization (P = 0.36), NYHA Functional Classes III and IV (P = 0.17), and TR severity >2+ at last follow-up (P = 0.42). Multivariable Cox-regression weighted by IPTW showed improved 1-year survival after TTVI compared with medical therapy alone in both women (adjusted hazard ratio 0.45, 95% confidence interval 0.23-0.83, P = 0.01) and men (adjusted hazard ratio 0.42, 95% confidence interval 0.18-0.89, P = 0.03). CONCLUSION: After TTVI in high-risk patients, there were no sex-related differences in terms of survival, HF hospitalization, functional status, and TR reduction up to 1 year. The IPTW analysis shows a survival benefit of TTVI over medical therapy alone in both women and men.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Masculino , Humanos , Feminino , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Sistema de Registros , Insuficiência Cardíaca/complicações
12.
EuroIntervention ; 18(12): 977-986, 2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36093795

RESUMO

BACKGROUND: The ACURATE neo2 (NEO2) and Evolut PRO/PRO+ (PRO) bioprostheses are new-generation self-expanding valves developed for transcatheter aortic valve replacement (TAVR). AIMS: We sought to compare the performance of the ACURATE neo2 and Evolut PRO/PRO+ devices. METHODS: The NEOPRO-2 registry retrospectively included patients who underwent TAVR for severe aortic stenosis with either the NEO2 or PRO devices between August 2017 and December 2021 at 20 centres. In-hospital and 30-day Valve Academic Research Consortium (VARC)-3 defined outcomes were evaluated. Propensity score (PS) matching and binary logistic regression were performed to adjust the treatment effect for PS quintiles. A subgroup analysis assessed the impact of aortic valve calcification. RESULTS: A total of 2,175 patients (NEO2: n=763; PRO: n=1,412) were included. The mean age was 82±6.2 years and the mean Society of Thoracic Surgeons score was 4.2%. Periprocedural complications were low, and both groups achieved high rates of technical success (93.1% vs 94.1%; p=0.361) and predischarge intended valve performance (96.0% vs 94.1%; p=0.056), both in the unmatched and matched analysis (452 pairs). Device success at 30 days was comparable (84.3% vs 83.6%; p=0.688), regardless of aortic valve calcification severity (p>0.05 for interaction). A suggestion for higher VARC-3 early safety in the NEO2 group was mainly driven by reduced rates of new permanent pacemaker implantation (7.7% vs 15.6%; p<0.001). CONCLUSIONS: This retrospective analysis reports a similar short-term performance of the ACURATE neo2 platform compared with the new-generation Evolut PRO/PRO+ devices. Randomised studies are needed to confirm our exploratory findings.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Humanos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
J Cardiovasc Surg (Torino) ; 64(6): 570-582, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38385840

RESUMO

INTRODUCTION: Meta-analyses and emerging randomized data indicate that second-generation ('mesh') carotid stents (SGS) may improve outcomes versus conventional (single-layer) stents but clinically-relevant differences in individual SGS-type performance have been identified. No comparisons exist for SGS versus carotid endarterectomy (CEA). EVIDENCE ACQUISITION: Thirty-day death (D), stroke (S), myocardial infarction (M), and 12-month ipsilateral stroke and restenosis in SGS studies were meta-analyzed (random effect model) against CEA outcomes. Eligible studies were identified through PubMed/EMBASE/COCHRANE. Forest plots were formed for absolute adverse evet risk in individual studies and for relative outcomes with each SGS deign versus contemporary CEA outcomes as reference. Meta-regression was performed to identify potential modifiers of treatment modality effect. EVIDENCE SYNTHESIS: Data were extracted from 103,642 patients in 25 studies (14 SGS-treated, 41% symptomatic; nine randomized controlled trial (RCT)-CEA-treated, 37% symptomatic; and two Vascular Quality Initiative (VQI)-CEA-treated, 23% symptomatic). Casper/Roadsaver and CGuard significantly reduced DSM versus RCT-CEA (-2.70% and -2.95%, P<0.001 for both) and versus VQI-CEA (-1.11% and -1.36%, P<0.001 for both). Gore stent 30-day DSM was similar to RCT-CEA (P=0.581) but increased against VQI-CEA (+2.38%, P=0.033). At 12 months, Casper/Roadsaver ipsilateral stroke rate was lower than RCT-CEA (-0.75%, P=0.026) and similar to VQI-CEA (P=0.584). Restenosis with Casper/Roadsaver was +4.18% vs. RCT-CEA and +4.83% vs. VQI-CEA (P=0.005, P<0.001). CGuard 12-month ipsilateral stroke rate was similar to VQI-CEA (P=0.850) and reduced versus RCT-CEA (-0.63%, P=0.030); restenosis was reduced respectively by -0.26% and -0.63% (P=0.033, P<0.001). Twelve-month Gore stent outcomes were overall inferior to surgery. CONCLUSIONS: Meta-analytic integration of available clinical data indicates: 1) reduction in stroke but increased restenosis rate with Casper/Roadsaver, and 2) reduction in both stroke and restenosis with CGuard MicroNET-covered stent against contemporary CEA outcomes at 30 days and 12 months used as a reference. This may inform clinical practice in anticipation of large-scale randomized trials powered for low clinical event rates (PROSPERO-CRD42022339789).


Assuntos
Endarterectomia das Carótidas , Acidente Vascular Cerebral , Humanos , Artérias Carótidas , Constrição Patológica , Endarterectomia das Carótidas/efeitos adversos , Stents , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Procedimentos Cirúrgicos Vasculares , Ensaios Clínicos Controlados Aleatórios como Assunto
14.
Catheter Cardiovasc Interv ; 100(6): 1090-1099, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36229946

RESUMO

OBJECTIVES: The PERFORMANCE I study was designed to evaluate the safety and feasibility of the Neuroguard IEP® System, a novel carotid stent system with an integrated embolic filter and post-dilatation balloon, to treat clinically significant carotid artery stenosis. BACKGROUND: The risk of major adverse events during carotid artery stenting is comparable to carotid endarterectomy, however, the risk of minor stroke remains higher with stenting. METHODS: In total, 67 patients undergoing carotid artery stenting were enrolled at nine centers in Europe. Follow-up assessments included neurological exams, duplex ultrasound, 12-lead electrocardiogram, and cardiac enzyme analysis. The primary endpoint was the 30-day composite rate of stroke, death, and myocardial infarctions versus a prespecified performance goal. Secondary endpoints included procedure success, device success, and target lesion revascularization. RESULTS: The study population was predominantly male (74.6%) with a mean age of 69.3 ± 8.9 years and 67% of subjects met at least one criterion placing them at an elevated risk for adverse events following carotid endarterectomy. All patients were treated successfully with the study device. There were no deaths or strokes within 30 days of the index procedure. One subject (1.5%) experienced a non-ST elevation myocardial infarction at day 17. The primary endpoint was met with a 30-day major adverse events rate of 1.5% (1/67). Through 12-month follow-up, there were no strokes, neurological deaths, target lesion revascularizations, or instances of in-stent-restenosis. CONCLUSIONS: Results from this study demonstrate the Neuroguard IEP system is safe and feasible with a stroke/death rate of 0% at 30 days. A large pivotal study is currently underway.


Assuntos
Estenose das Carótidas , Dispositivos de Proteção Embólica , Endarterectomia das Carótidas , Acidente Vascular Cerebral , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/terapia , Stents , Dilatação , Resultado do Tratamento , Fatores de Tempo , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Risco
16.
Front Cardiovasc Med ; 9: 931207, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35966561

RESUMO

Background: A severe prosthesis-patient mismatch (PPM) is associated with adverse outcomes following transcatheter aortic valve replacement (TAVR) for de novo aortic stenosis or a failed surgical bioprosthesis. The impact of severe PPM in patients undergoing TAV-in-TAVR is unknown. Aim: We sought to investigate the incidence and 1-year outcomes of different grades of PPM in patients undergoing TAV-in-TAVR. Materials and methods: The TRANSIT-PPM is an international registry, including cases of degenerated TAVR treated with a second TAVR. PPM severity, as well as in-hospital, 30-day, and 1-year outcomes were defined according to the Valve Academic Research Consortium-3 (VARC-3) criteria. Results: Among 28 centers, 155 patients were included. Severe PPM was found in 6.5% of patients, whereas moderate PPM was found in 14.2% of patients. The rate of severe PPM was higher in patients who underwent TAV-in-TAVR with a second supra-annular self-expanding (S-SE) TAVR (10%, p = 0.04). Specifically, the rate of severe PPM was significantly higher among cases of a SE TAVR implanted into a balloon-expandable (BE) device (19%, p = 0.003). At 1-year follow-up, the rate of all-cause mortality, and the rate of patients in the New York Heart Association (NYHA) class III/IV were significantly higher in the cohort of patients with severe PPM (p = 0.016 and p = 0.0001, respectively). Almost all the patients with a severe PPM after the first TAVR had a failed < 23 mm BE transcatheter heart valve (THV): the treatment with an S-SE resolved the severe PPM in the majority of the cases. Conclusion: After TAV-in-TAVR, in a fifth of the cases, a moderate or severe PPM occurred. A severe PPM is associated with an increased 1-year all-cause mortality. Clinical trial registration: [https://clinicaltrials.gov], identifier [NCT04500964].

17.
J Clin Med ; 11(16)2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-36013058

RESUMO

Background: Single-cohort studies suggest that second-generation stents (SGS; "mesh stents") may improve carotid artery stenting (CAS) outcomes by limiting peri- and postprocedural cerebral embolism. SGS differ in the stent frame construction, mesh material, and design, as well as in mesh-to-frame position (inside/outside). Objectives: To compare clinical outcomes of SGS in relation to first-generation stents (FGSs; single-layer) in CAS. Methods: We performed a systematic review and meta-analysis of clinical studies with FGSs and SGS (PRISMA methodology, 3302 records). Endpoints were 30-day death, stroke, myocardial infarction (DSM), and 12-month ipsilateral stroke (IS) and restenosis (ISR). A random-effect model was applied. Results: Data of 68,422 patients from 112 eligible studies (68.2% men, 44.9% symptomatic) were meta-analyzed. Thirty-day DSM was 1.30% vs. 4.11% (p < 0.01, data for SGS vs. FGS). Among SGS, both Casper/Roadsaver and CGuard reduced 30-day DSM (by 2.78 and 3.03 absolute percent, p = 0.02 and p < 0.001), whereas the Gore stent was neutral. SGSs significantly improved outcomes compared with closed-cell FGS (30-day stroke 0.6% vs. 2.32%, p = 0.014; DSM 1.3% vs. 3.15%, p < 0.01). At 12 months, in relation to FGS, Casper/Roadsaver reduced IS (−3.25%, p < 0.05) but increased ISR (+3.19%, p = 0.04), CGuard showed a reduction in both IS and ISR (−3.13%, −3.63%; p = 0.01, p < 0.01), whereas the Gore stent was neutral. Conclusions: Pooled SGS use was associated with improved short- and long-term clinical results of CAS. Individual SGS types, however, differed significantly in their outcomes, indicating a lack of a "mesh stent" class effect. Findings from this meta-analysis may provide clinically relevant information in anticipation of large-scale randomized trials.

18.
EuroIntervention ; 18(10): 804-811, 2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-35678222

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) with the ACURATE neo device has been associated with a non-negligible incidence of paravalvular aortic regurgitation (AR). The new-generation ACURATE neo2 has been designed to mitigate this limitation. AIMS: The aim of the study was to compare TAVR with the ACURATE neo and neo2 devices. METHODS: The NEOPRO and NEOPRO-2 registries retrospectively included patients undergoing transfemoral TAVR with self-expanding valves at 24 and 20 centres, respectively. Patients receiving the ACURATE neo and neo2 devices (from January 2012 to December 2021) were included in this study. Predischarge and 30-day VARC-3 defined outcomes were evaluated. The primary endpoint was predischarge moderate or severe paravalvular AR. Subgroup analyses per degree of aortic valve calcification were performed. RESULTS: A total of 2,026 patients (neo: 1,263, neo2: 763) were included. Predischarge moderate or severe paravalvular AR was less frequent for the neo2 group (2% vs 5%; p<0.001), resulting in higher VARC-3 intended valve performance (96% vs 90%; p<0.001). Furthermore, more patients receiving the neo2 had none/trace paravalvular AR (59% vs 38%; p<0.001). The reduction in paravalvular AR with neo2 was mainly observed with heavy aortic valve calcification. New pacemaker implantation and VARC-3 technical and device success rates were similar between the 2 groups; there were more frequent vascular and bleeding complications for the neo device. Similar 1-year survival was detected after TAVR (neo2: 90% vs neo: 87%; p=0.14). CONCLUSIONS: TAVR with the ACURATE neo2 device was associated with a lower prevalence of moderate or severe paravalvular AR and more patients with none/trace paravalvular AR. This difference was particularly evident with heavy aortic valve calcification.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Resultado do Tratamento , Fatores de Tempo , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Hemodinâmica
19.
EuroIntervention ; 18(10)Mar. 2022. graf, tab
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1378039

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) with the ACURATE neo device has been associated with a non-negligible incidence of paravalvular aortic regurgitation (AR). The new-generation ACURATE neo2 has been designed to mitigate this limitation. AIMS: The aim of the study was to compare TAVR with the ACURATE neo and neo2 devices. METHODS: The NEOPRO and NEOPRO-2 registries retrospectively included patients undergoing transfemoral TAVR with self-expanding valves at 24 and 20 centres, respectively. Patients receiving the ACURATE neo and neo2 devices (from January 2012 to December 2021) were included in this study. Predischarge and 30-day VARC-3 defined outcomes were evaluated. The primary endpoint was predischarge moderate or severe paravalvular AR. Subgroup analyses per degree of aortic valve calcification were performed. RESULTS: A total of 2,026 patients (neo: 1,263, neo2: 763) were included. Predischarge moderate or severe paravalvular AR was less frequent for the neo2 group (2% vs 5%; p<0.001), resulting in higher VARC-3 intended valve performance (96% vs 90%; p<0.001). Furthermore, more patients receiving the neo2 had none/trace paravalvular AR (59% vs 38%; p<0.001). The reduction in paravalvular AR with neo2 was mainly observed with heavy aortic valve calcification. New pacemaker implantation and VARC-3 technical and device success rates were similar between the 2 groups; there were more frequent vascular and bleeding complications for the neo device. Similar 1-year survival was detected after TAVR (neo2: 90% vs neo: 87%; p=0.14). CONCLUSIONS: TAVR with the ACURATE neo2 device was associated with a lower prevalence of moderate or severe paravalvular AR and more patients with none/trace paravalvular AR. This difference was particularly evident with heavy aortic valve calcification.


Assuntos
Insuficiência da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Hemodinâmica
20.
JACC Cardiovasc Interv ; 15(4): 411-422, 2022 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-35210047

RESUMO

OBJECTIVES: This study evaluated the incidence, management, and outcome of patients who experienced MitraClip (Abbott Vascular) failure secondary to loss of leaflet insertion (LLI), single leaflet detachment (SLD), or embolization. BACKGROUND: Transcatheter edge-to-edge repair with MitraClip is an established therapy for the treatment of mitral regurgitation (MR), but no data exist regarding the prevalence and outcome according to the mode of clip failure. METHODS: Between January 2009 and December 2020, we retrospectively screened 4,294 procedures of MitraClip performed in 19 centers. LLI was defined as damage to the leaflet where the MitraClip was attached, SLD as demonstration of complete separation between the device and a single leaflet tissue, and clip embolization as loss of contact between MitraClip and both leaflets. RESULTS: A total of 147 cases of MitraClip failure were detected (overall incidence = 3.5%), and these were secondary to LLI or SLD in 47 (31.9%) and 99 (67.3%) cases, respectively, whereas in 1 (0.8%) case clip embolization was observed. MitraClip failure occurred in 67 (45.5%) patients with functional MR, in 64 (43.5%) patients with degenerative MR, and 16 (10.8%) with mixed etiology. Although the majority of MitraClip failures were detected before discharge (47 intraprocedural and 42 in the hospital), up to 39.5% of cases were diagnosed at follow-up. In total, 80 (54.4%) subjects underwent a redo procedure, either percutaneously with MitraClip (n = 51, 34.7%) or surgically (n = 36, 24.5%) including 4 cases of surgical conversion of the index procedure and 7 cases of bailout surgery after unsuccessful redo MitraClip. After a median follow-up of 163 days (IQR: 22-720 days), 50 (43.9%) subjects presented moderate to severe MR, and 43 (29.3%) patients died. An up-front redo MitraClip strategy was associated with a trend toward a reduced rate of death at follow-up vs surgical or conservative management (P = 0.067), whereas postprocedural acute kidney injury, age, and moderate to severe tricuspid regurgitation were independent predictors of death. CONCLUSIONS: MitraClip failure secondary to LLI and SLD is not a rare phenomenon and may occur during and also beyond hospitalization. Redo MitraClip strategy demonstrates a trend toward a reduced risk of death compared with bailout surgery and conservative management. A third of those patients remained with more than moderate MR and had substantial mortality at the intermediate-term follow-up.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...