Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Arthroplasty ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38604284

RESUMO

BACKGROUND: Robotic-arm assistance continues to gain popularity in total hip arthroplasty (THA) for its potential to improve component placement accuracy and patient outcomes. Nonetheless, there is limited data on the impact of robotic-assisted THA (RA-THA) on hospital length of stay (LOS) and discharge location. This study thus aimed to compare LOS, discharge location, and readmission rate for propensity-matched cohorts of RA-THA versus manual THA (M-THA). METHODS: A retrospective review of a multi-hospital database was performed to identify patients who underwent THA between January 2016 and December 2021 from surgeons who performed both RA-THA and M-THA at 77 geographically diverse hospitals. The RA-THA and M-THA cohorts were 1-to-1 matched based on patient sex, age, and body mass index, resulting in 8,536 patients per cohort. Insurance type, LOS, same-day discharge, discharge disposition, and 90-day all-cause readmission rate were compared using Mann-Whitney U and Chi-square tests. RESULTS: Average LOS was significantly shorter for RA-THA patients (1.39 ± 0.85 days) than for M-THA patients (1.48 ± 0.91 days, P < .001). Compared to 5.6% of M-THA patients, 5.3% of RA-THA patients underwent same-day discharge (P = .38). There were statistically significant differences in discharge disposition between cohorts, with more RA-THA cases discharged home without home healthcare compared to M-THA (47.9 versus 45.5%, P = .001) and fewer RA-THA cases discharged to a skilled nursing facility compared to M-THA (5.6 versus 6.9%, P = .001). The 90-day all-cause readmission rate for RA-THA cases was 3.0%, compared to 3.4% for M-THA cases (P = .26). CONCLUSIONS: Compared to M-THA, RA-THA had a shorter average LOS, a similar percentage of patients with same-day discharge, fewer patients who had skilled nursing facility discharge, and a similar all-cause 90-day readmission rate. These results may be of interest to surgeons participating in bundled payment programs and engaging in cost savings.

2.
J Orthop ; 54: 163-167, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38605902

RESUMO

Introduction: Total knee arthroplasty (TKA) is a complex surgical procedure that traditionally relies on two-dimensional radiographs for pre-operative planning. These radiographs may not capture the intricate details of individual knee anatomy, potentially limiting the precision of surgical interventions. With advancements in imaging technology, there is an opportunity to refine TKA outcomes. This study introduces the Native Alignment Phenotype classification system that is based on pre-operative 3-dimensional computed tomography (CT) scans, aiming to provide a more detailed understanding of knee deformities and their influence on characterizing knee osteoarthritis and planning for TKA procedures. Methods: There were 1406 pre-operative non-weight-bearing CT scans analyzed by a single surgeon experienced with robotically-assisted total knee arthroplasties. These scans were converted into three-dimensional models, focusing on the coronal and sagittal planes. Intraoperatively, the robotic system was used to capture native coronal and sagittal deformities for each patient. These values were captured with the patient's leg held in a non-stress, extension pose. A new classification system, 'The Native Alignment Phenotype', was developed to categorize the specific differences between individual knees. Results: There were four primary knee malalignments identified: varus deformity; valgus deformity; and two deformities in the sagittal plane. These malalignments were further categorized based on the degrees of deviation, creating groups with 5° coronal and sagittal ranges. A total of 77 phenotypic alignment patterns were found based on the analyzed cohort. In the coronal plane, varus HKA deformity between 6 and 10° was the most common, with 36.9% of the cases, followed by varus HKA alignment, which was between 0 and 5°, representing 34.3% of the cases. In the sagittal plane, neutral and flexion contracture deformities between 0 and 5° were the most common, with 32.6% of the cases, followed by a fixed flexion contracture alignment, which was between 6 and 10°, representing 28.7% of the cases. When combining coronal and sagittal planes, the most common alignment was the varus between 0 and 5° with a flexion contracture between 0 and 5° (12.5% of cases), closely followed by the varus between 6 and 10° with a flexion contracture between 6 and 10° (12.4% of cases). Conclusion: The Native Alignment Phenotype classification system offers a nuanced understanding of knee deformities based on three-dimensional (CT scan) assessments, potentially leading to improved surgical outcomes in TKA. By leveraging the detailed data from the CT scans, this system provides a more comprehensive view of the knee's anatomy, emphasizing the importance of individualized, data-driven approaches in knee surgery.

3.
Surg Technol Int ; 442024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38442246

RESUMO

INTRODUCTION: Manual techniques for total hip arthroplasty (THA) have been widely utilized and proven to be clinically successful. However, the use of advanced computed tomography (CT) scan-based planning and haptically-bounded reamers in robotic-arm assisted total hip arthroplasty (RTHA) holds promise for potentially limiting surrounding soft-tissue damage. This cadaver-based study aimed to compare the extent of soft-tissue damage between a robotic-arm assisted, haptically-guided THA (RTHA) and a manual, fluoroscopic-guided THA (MTHA) direct anterior approach. MATERIALS AND METHODS: There were six fresh-frozen torso-to-toe cadaver specimens included, with two surgeons each performing three RTHA and three MTHA procedures. One hip underwent an RTHA and the other hip received an MTHA in each cadaver. Postoperatively, one additional surgeon, blinded to the procedures, assessed and graded damage to nine key anatomical structures using a 1 to 4 grading scale: (1) complete soft-tissue preservation to <5% of damage; (2) 6 to 25% of damage; (3) 26 to 75% of damage; and (4) 76 to 100% of damage. Kruskal-Wallis hypothesis tests were used to compare soft-tissue damage between RTHA and MTHA cases and adjusted for ties. RESULTS: Pooled analysis of the gluteus minimus, sartorius, tensor fascia lata, and vastus lateralis muscle grades demonstrated that cadaver specimens who underwent RTHA underwent less damage to these structures than following MTHA (median, IQR: 1.0, 1.0 to 2.0 vs. 3.0, 2.0 to 3.0; p=0.003). Pooled analysis of the calculated volumetric damage (mm3) for the gluteus minimus, sartorius, tensor fascia lata, and vastus lateralis muscles demonstrated that the cadaver specimens that underwent RTHA underwent less damage to these structures than those that followed MTHA (median, IQR: 23, 2 to 586 vs. 216, 58 to 3,050; p=0.037). CONCLUSION: This cadaver-based study suggests that utilizing RTHA may lead to reduced soft-tissue damage compared with MTHA, likely due to enhanced preoperative planning with robotic-arm assisted software, real-time intraoperative feedback, haptically-bounded reamer usage, reduced surgical steps, as well as ease of use with reaming. These findings should be carefully considered when evaluating the utilization of robotic-arm assisted THA in practice.

4.
J Knee Surg ; 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38113912

RESUMO

Soft-tissue balancing is an important factor in primary total knee arthroplasty (TKA), with 30 to 50% of TKA revisions attributed to technical operative factors including soft-tissue balancing. Robotic-assisted TKA (RATKA) offers opportunities for improved soft-tissue balancing methods. This study aimed to evaluate the repeatability and reproducibility of ligamentous laxity assessments during RATKA using a digital tensioner.Three experienced RATKA surgeons assessed preresection and trialing phases of 12 human cadaveric knees with varying degrees of arthritis. Ligamentous laxity was assessed with manual varus and valgus stresses in extension and flexion, with a digital tensioner providing feedback on the change of laxity displacement. Intraclass correlation coefficient (ICC) analyses were used to determine the repeatability within a single surgeon and reproducibility between the three surgeons.The results showed excellent repeatability and reproducibility in ligamentous laxity assessment during RATKA. Surgeons had excellent repeatability for preresection and trialing assessments, with median ICC values representing excellent reproducibility between surgeons. Surgeons were repeatable within 1 or 1.5 mm for preresection and trialing assessments. On average, the variation within a surgeon was 0.33 ± 0.26 mm during preresection and 0.29 ± 0.28 mm during trialing. When comparing surgeons to each other, they were reproducible within an average of 0.69 ± 0.33 mm for preresection and 0.65 ± 0.31 mm for trialing.This study demonstrated the reliability of robotic-assisted soft-tissue balancing techniques, providing control over ligamentous laxity assessments, and potentially leading to better patient outcomes. The digital tensioner used in this study provided excellent repeatability and reproducibility in ligamentous laxity assessment during RATKA, highlighting the potential benefits of incorporating robotics in TKA procedures.

5.
Surg Technol Int ; 432023 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-37781883

RESUMO

BACKGROUND: Robotic-assisted total knee arthroplasty (TKA) has been associated with improved accuracy and precision of implant placement, protection of soft tissue, and improved patient-reported postoperative outcomes when compared to manual TKA techniques. Previous studies have highlighted the importance of surgical confidence throughout the learning curve when adopting robotic-assisted platforms. The purpose of this study was to evaluate the confidence and efficiencies of surgeons when utilizing computed tomography (CT)-based robotic TKA technology. MATERIALS AND METHODS: A cross-sectional, questionnaire-based study was conducted with 20 arthroplasty-trained surgeons with prior experience in both manual TKA and robotic-assisted TKA techniques. The surgeons completed an initial learning period, with new software, during various stages of their experience. The new TKA software upgrade builds on the prior software version with new features. A Net Promoter Score (NPS), the measurement of a respondent's likelihood to recommend a product or service to others, was used during the analysis of survey questions. A NPS over 50 indicates a positive score. RESULTS: When compared to manual TKA techniques, 95% of surgeons reported that their overall intraoperative confidence increased with the new software upgrade for CT-based robotic technology and had an average rating of 8.9 out of 10 for their intraoperative confidence with the new software upgrade. Additionally, 100% of surgeons reported that they were more confident when performing intraoperative implant adjustments with the new software upgrade when compared to manual TKA. Surgeons determined that the overall use of the new software upgrade was intuitive (8.4 of 10 average rating) and were satisfied with the overall use of the new software upgrade (9 of 10 average rating). Also, surgeons reported that they would recommend the new software upgrade for CT-based robotic technology to colleagues (NPS of 85), as well as being used as a research tool (NPS of 85) or for a training and education tool in a fellowship program (NPS of 90). CONCLUSION: As new technology continues to enter the field of orthopedics, it is important to ensure upgrades and advancements continue to serve surgeons and provide efficiencies in the operating room. For established robotic surgeons, the new robotic technology assessed in this study provided increased confidence when compared to manual TKA. Based on these results, the new software upgrade demonstrated value during various stages of a TKA procedure and is highly recommended for use by others in the field of orthopedics.

6.
J Knee Surg ; 36(14): 1462-1466, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36657463

RESUMO

Computed tomography (CT) scan-based three-dimensional (3D) modeling operative technology has been shown to improve upon results of manual total knee arthroplasties (TKAs). Although there are many reports on superior precision of this CT-based technology, there has been continuing interest regarding extended clinical outcomes. The purpose of this study was to compare their clinical outcomes with manual TKAs at approximately 3-year follow-up. Specifically, we analyzed: (1) survivorship, (2) functional outcomes, (3) complications, and (4) radiographic outcomes (i.e., alignment, progressive radiolucencies). A total of 210 patients receiving CT-based TKAs performed by a single surgeon at a single center between July 1, 2016, and February 16, 2018, were compared with 210 manual TKAs completed by the same surgeon immediately preceding implementation of the CT-based technology. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) surveys were collected at ∼3 years postoperatively. Subgroup analyses of pain and physical function scores were performed. Follow-up radiographs were evaluated for alignment, loosening, and/or progressive radiolucencies. There was 100% survivorship at final follow-up. The postoperative mean pain scores for the CT-based cohort and manual cohort were 1 ± 2 (range, 0-14) and 2 ± 3 (range, 0-17), respectively (p < 0.05). The postoperative mean physical function scores for the CT-based cohort and manual cohort were 3 ± 4 (range, 0-18) and 5 ± 5 (range, 0-19), respectively (p < 0.05). The postoperative mean total WOMAC scores for the CT-based cohort and manual cohort were 5 ± 4 (range, 0-32) and 7 ± 8 (range, 0-35), respectively (p < 0.05). There were low numbers of postoperative complications at final follow-up in either cohort. None exhibited progressive radiolucencies by final follow-up. The 3-year postoperative clinical outcomes support excellent survivorship and radiographic outcomes, low complication rates, as well as improved pain, physical function, and total WOMAC scores for CT-based TKAs. Therefore, patients who undergo CT-based 3D modeling TKAs should expect to have superior long-term clinical outcomes.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Resultado do Tratamento , Dor Pós-Operatória , Tomografia Computadorizada por Raios X , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Seguimentos
7.
J Knee Surg ; 36(13): 1386-1390, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36564042

RESUMO

Many studies involving robotic-assisted total knee arthroplasty (RATKA) have demonstrated superiority regarding soft tissue balance and consistency with alignment target achievement. However, studies investigating whether RATKA is associated with improved patient outcomes regarding physical function and pain are also important. Therefore, we performed a cluster analysis and examined factors that contributed to differences in patient-reported outcome measures (PROMs). Specifically, we analyzed: (1) reduced WOMAC (rWOMAC) scores regarding pain and function; (2) usage of RATKA; (3) common patient comorbidities; as well as (4) patient demographic factors. The rWOMAC score is an abbreviated PROM that includes pain and physical function domains. This study analyzed 853 patients (95 conventional and 758 robotic-assisted) who had completed preoperative, 6-month, and 1-year postoperative rWOMAC surveys. Two clusters were constructed using rWOMAC pain and function scores at 1 year. Cluster 1 included 753 patients who had better outcomes at 1 year (mean rWOMAC pain = 0.9, mean rWOMAC function = 1.4), and cluster 2 included 100 patients who had worse outcomes at 1 year (mean rWOMAC pain = 7.7, mean rWOMAC function = 10.4). The clusters were compared to determine (1) how scores improved and (2) what patient characteristics were significantly different between clusters. Cluster 1 demonstrated greater improvement from preoperative to 6 months or 1 year (p = 0.0013 for pain preoperative to 6 months, p< 0.0001 for other measures) and 6 months to 1 year (p< 0.0001). Comparisons demonstrated that cluster 1 had older patients (67 vs. 65 years, p = 0.0479) who had lower body mass index or BMIs (31.8 vs. 33.9 kg/m2, p = 0.0042) and no significant differences in sex (p = 0.7849). Cluster 1 also had a significantly higher percentage of RATKA patients (90 vs. 79%, p< 0.001). Cluster analyses provided differentiating factors which were associated with improved postoperative rWOMAC pain and function scores at 1 year. Patients undergoing robotic-assisted TKA were associated with better rWOMAC pain and function scores from preoperative to 6 months and 1 year.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Dor Pós-Operatória/etiologia , Comorbidade , Medidas de Resultados Relatados pelo Paciente , Análise por Conglomerados , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/cirurgia , Resultado do Tratamento
8.
J Knee Surg ; 36(2): 159-166, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34187064

RESUMO

Robotic-assisted technology has been developed to optimize the consistency and accuracy of bony cuts, implant placements, and knee alignments for total knee arthroplasty (TKA). With recently developed designs, there is a need for the reporting longer than initial patient outcomes. Therefore, the purpose of this study was to compare manual and robotic-assisted TKA at 2-year minimum for: (1) aseptic survivorship; (2) reduced Western Ontario and McMaster Universities Osteoarthritis Index (r-WOMAC) pain, physical function, and total scores; (3) surgical and medical complications; and (4) radiographic assessments for progressive radiolucencies. We compared 80 consecutive cementless robotic-assisted to 80 consecutive cementless manual TKAs. Patient preoperative r-WOMAC and demographics (e.g., age, sex, and body mass index) were not found to be statistically different. Surgical data and medical records were reviewed for aseptic survivorship, medical, and surgical complications. Patients were administered an r-WOMAC survey preoperatively and at 2-year postoperatively. Mean r-WOMAC pain, physical function, and total scores were tabulated and compared using Student's t-tests. Radiographs were reviewed serially throughout patient's postoperative follow-up. A p < 0.05 was considered significant. The aseptic failure rates were 1.25 and 5.0% for the robotic-assisted and manual cohorts, respectively. Patients in the robotic-assisted cohort had significantly improved 2-year postoperative r-WOMAC mean pain (1 ± 2 vs. 2 ± 3 points, p = 0.02), mean physical function (2 ± 3 vs. 4 ± 5 points, p = 0.009), and mean total scores (4 ± 5 vs, 6 ± 7 points, p = 0.009) compared with the manual TKA. Surgical and medical complications were similar in the two cohorts. Only one patient in the manual cohort had progressive radiolucencies on radiographic assessment. Robotic-assisted TKA patients demonstrated improved 2-year postoperative outcomes when compared with manual patients. Further studies could include multiple surgeons and centers to increase the generalizability of these results. The results of this study indicate that patients who undergo robotic-assisted TKA may have improved 2-year postoperative outcomes.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Seguimentos , Resultado do Tratamento , Articulação do Joelho/cirurgia , Dor Pós-Operatória/etiologia
9.
Orthop Clin North Am ; 53(4): 413-419, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36208884

RESUMO

This study compared differences in (1) task duration; (2) biometric parameters (ie, caloric energy expenditure, heart rate); and (3) subjective measures of mental as well as physical demand of robotic-assisted total hip arthroplasty (THA) and manual THA. A total of 12 THAs were performed on 6 cadaveric specimens by two surgeons using a wearable technology to track biometric parameters and taking a questionnaire to compare the physical and mental demands. The results of our study suggest that as compared with manual techniques, robotic assistance for THA may reduce mental and physical fatigue.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Procedimentos Cirúrgicos Robóticos , Artroplastia de Quadril/métodos , Humanos , Exame Físico , Procedimentos Cirúrgicos Robóticos/métodos
10.
J Knee Surg ; 35(2): 198-203, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32906160

RESUMO

Implant malalignment during total knee arthroplasty (TKA) may lead to suboptimal postoperative outcomes. Accuracy studies are typically performed with experienced surgeons; however, it is important to study less experienced surgeons when considering teaching hospitals where younger surgeons operate. Therefore, this study assessed whether robotic-arm assisted TKA (RATKA) allowed for more accurate and precise implant position to plan when compared with manual techniques when the surgery is performed by in-training orthopaedic surgical fellows. Two surgeons, currently in their fellowship training and having minimal RATKA experience, performed a total of six manual TKA (MTKA) and six RATKAs on paired cadaver knees. Computed tomography scans were obtained for each knee pre- and postoperatively. These scans were analyzed using a custom autosegmentation and autoregistration process to compare postoperative implant position with the preoperative planned position. Mean system errors and standard deviations were compared between RATKA and MTKA for the femoral component for sagittal, coronal, and axial planes and for the tibial component in the sagittal and coronal planes. A 2-Variance testing was performed using an α = 0.05. Although not statistically significant, RATKA was found to have greater accuracy and precision to plan than MTKA for: femoral axial plane (1.1° ± 1.1° vs. 1.6° ± 1.3°), coronal plane (0.9° ± 0.7° vs. 2.2° ± 1.0°), femoral sagittal plane (1.5° ± 1.3° vs. 3.1° ± 2.1°), tibial coronal plane (0.9° ± 0.5° vs. 1.9° ± 1.3°), and tibial sagittal plane (1.7° ± 2.6° vs. 4.7° ± 4.1°). There were no statistical differences between surgical groups or between the two surgeons performing the cases. With limited RATKA experience, fellows showed increased accuracy and precision to plan for femoral and tibial implant positions. Furthermore, these results were comparable to what has been reported for an experienced surgeon performing RATKA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Procedimentos Cirúrgicos Robóticos , Cirurgiões , Cirurgia Assistida por Computador , Bolsas de Estudo , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia
11.
J Knee Surg ; 35(9): 1010-1018, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33511589

RESUMO

This study compared surgeon cervical (C) spine postures and repetitive motions when performing traditional manual total knee arthroplasty (MTKA) versus robotic-assisted TKA (RATKA). Surgeons wore motion trackers on T3 vertebra and the occiput anatomical landmarks to obtain postural and repetitive motion data during MTKA and RATKA performed on cadavers. We assessed (1) flexion-extension at T3 and the occiput anatomical landmarks, (2) range of motion (ROM) as the percentage of time in the flexion-extension angle, (3) repetition rate, defined as the number of the times T3 and the occiput flexion-extension angle exceeded ±10°; and (4) static posture, where T3 or occiput postures exceed 10° for more than 30 seconds. The average T3 flexion-extension angle for MTKA cases was 5-degree larger than for RATKA cases (19 ± 8 vs. 14 ± 8 degrees). The surgeons who performed MTKA cases spent 15% more time in nonneutral C-spine ROM than those who performed RATKA cases (78 ± 25 vs. 63 ± 36%, p < 0.01). The repetition rate at T3 was 4% greater for MTKA than RATKA (14 ± 5 vs. 10 ± 6 reps/min). The percentage of time spent in static T3 posture was 5% greater for overall MTKA cases than for RATKA cases (15 ± 3 vs. 10 ± 3%). In this cadaveric study, we found differences in cervical and thoracic ergonomics between manual and robotic-assisted TKA. Specifically, we found that RATKA may reduce a surgeon's ergonomic strain at both the T3 and occiput locations by reducing the time the surgeon spends in a nonneutral position.


Assuntos
Artroplastia do Joelho , Procedimentos Cirúrgicos Robóticos , Vértebras Cervicais/cirurgia , Humanos , Articulação do Joelho/cirurgia , Postura , Amplitude de Movimento Articular
12.
Surg Technol Int ; 39: 419-426, 2021 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-34352111

RESUMO

Partial knee arthroplasty (PKA) is performed to treat end-stage osteoarthritis in a single compartment. There are minimal data characterizing soft-tissue injuries for PKA with robotic and manual techniques. This cadaver study compared the extent of soft-tissue trauma sustained through robotic-arm assisted PKA (RPKA) and manual PKA (MPKA). Five surgeons prepared 24 cadaveric knees for medial PKA, including six MPKA controls and 18 RPKA assigned into three different workflows: RPKA-LB (six knees) - RPKA with legacy burr; RPKA-NB (six knees) - RPKA with new burr design; and RPKA-NBS (six knees) - RPKA with new burr design and oscillating saw. Two surgeons estimated trauma to the patellar tendon, quadriceps tendon, anterior cruciate ligament (ACL), medial collateral ligament (MCL), medial capsule, posterior capsule, and posterior cruciate ligament (PCLs) using a five-grade system: Grade 1 - complete soft tissue preservation; Grade 2 - ≤25%; Grade 3 - 26 to 50%; Grade 4 - 51 to 75%; and Grade 5 - ≥76% trauma. A total trauma grade was assigned by summing the grades. Kruskal-Wallis statistical tests were used to assess outcomes. When compared to the MPKA group, all RPKA subgroups had lower total trauma grading (p<0.01), lower posterior capsular damage (p<0.01), and less severe ACL damage (p<0.01). The analysis demonstrated no significant difference between the three RPKA workflows. As this study was performed using cadaveric specimens, additional investigations are necessary to determine associations between robotic or manual-assisted technique, observed soft tissue damage, and postoperative clinical outcomes following PKA.


Assuntos
Lesões do Ligamento Cruzado Anterior , Artroplastia do Joelho , Procedimentos Cirúrgicos Robóticos , Lesões do Ligamento Cruzado Anterior/cirurgia , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Humanos , Doença Iatrogênica , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular , Procedimentos Cirúrgicos Robóticos/efeitos adversos
13.
Surg Technol Int ; 39: 389-393, 2021 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-34312827

RESUMO

INTRODUCTION: Valgus knee deformities can sometimes be challenging to address during total knee arthroplasties (TKAs). While appropriate surgical technique is often debated, the role of new operative technologies in addressing these complex cases has not been clearly established. The purpose of this study was to analyze the usefulness of computed tomography scan (CT)-based three-dimensional (3D) modeling operative technology in assisting with TKA planning, execution of bone cuts, and alignment. Specifically, we evaluated valgus TKAs performed using this CT-based technology for: (1) intraoperative implant plan, number of releases, and surgeon prediction of component size; (2) survivorship and clinical outcomes at a minimum follow up of one year; and (3) radiographic outcomes. MATERIALS AND METHODS: A total of 152 patients who had valgus deformities receiving a CT-based TKA performed by a single surgeon were analyzed. Cases were performed using an enhanced preoperative planning and real-time intraoperative feedback and cutting tool. The surgeon predicted and recorded implant sizes preoperatively and all patients received implants with initial and final implant alignment, flexion/extension gaps, and full or partial soft tissue releases recorded. A modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS, JR.) scores were collected preoperatively and at approximately six months and one year postoperatively. Preoperative coronal alignment ranged from 1 to 13° valgus. Follow-up radiographs were also evaluated for alignments, loosenings, and/or progressive radiolucencies. RESULTS: A total of 96% of cases were corrected to within 3° of mechanical neutral. For outlier cases, initial deformities ranged from valgus 5 to 13°, with final alignment ranging from 4 to 8° valgus (mean 4° correction). Patients had mean femoral internal rotation of 2° and mean femoral flexion of 4°. The surgeon was within one size on the femur and tibia 94 and 100% of the time, respectively. Only one patient required a lateral soft tissue release and one patient had osteophytes removed, which required a medial soft tissue release. Five patients required manipulations under anesthesia. Aside from these, there were no postoperative medical and/or surgical complications and there was 100% survivorship at final follow up. WOMAC and KOOS, JR. scores improved significantly from a mean of 21 ± 9 and 48 ± 10 points preoperatively to 4 ± 6 (p<0.05) and 82 ± 15 (p<0.05) at final follow up, respectively. None of the cases exhibited progressive radiolucencies by final follow up. DISCUSSION: A limitation of this study was not evaluating dynamic kinematics in these patients to determine if rotation had any effects on kinematics. Future studies will evaluate this concern. Nevertheless, the technology successfully assisted with planning, executing bone cuts, and achieving alignment in TKAs complicated by the deformity. This may allow surgeons to predictably avoid soft tissue releases and accurately know component sizes preoperatively, while consistently achieving desired postoperative alignment. CONCLUSIONS: This study demonstrated the utility of CT-based 3D modeling techniques for challenging valgus deformity cases. Use of 3D modeling allowed the TKA components to be positioned according to the patient's anatomy in the coronal, transverse, and sagittal planes. When making these intraoperative implant adjustments, the surgeon may choose to place components outside the preoperative planning guidelines based on the clinical needs of the patient.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Fêmur/cirurgia , Humanos , Joelho , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Tíbia/cirurgia
14.
Bone Joint Res ; 8(10): 495-501, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31728189

RESUMO

OBJECTIVES: The use of the haptically bounded saw blades in robotic-assisted total knee arthroplasty (RTKA) can potentially help to limit surrounding soft-tissue injuries. However, there are limited data characterizing these injuries for cruciate-retaining (CR) TKA with the use of this technique. The objective of this cadaver study was to compare the extent of soft-tissue damage sustained through a robotic-assisted, haptically guided TKA (RATKA) versus a manual TKA (MTKA) approach. METHODS: A total of 12 fresh-frozen pelvis-to-toe cadaver specimens were included. Four surgeons each prepared three RATKA and three MTKA specimens for cruciate-retaining TKAs. A RATKA was performed on one knee and a MTKA on the other. Postoperatively, two additional surgeons assessed and graded damage to 14 key anatomical structures in a blinded manner. Kruskal-Wallis hypothesis tests were performed to assess statistical differences in soft-tissue damage between RATKA and MTKA cases. RESULTS: Significantly less damage occurred to the PCLs in the RATKA versus the MTKA specimens (p < 0.001). RATKA specimens had non-significantly less damage to the deep medial collateral ligaments (p = 0.149), iliotibial bands (p = 0.580), poplitei (p = 0.248), and patellar ligaments (p = 0.317). The remaining anatomical structures had minimal soft-tissue damage in all MTKA and RATKA specimens. CONCLUSION: The results of this study indicate that less soft-tissue damage may occur when utilizing RATKA compared with MTKA. These findings are likely due to the enhanced preoperative planning with the robotic software, the real-time intraoperative feedback, and the haptically bounded saw blade, all of which may help protect the surrounding soft tissues and ligaments.Cite this article: Bone Joint Res 2019;8:495-501.

15.
J Arthroplasty ; 34(4): 766-771, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30639282

RESUMO

BACKGROUND: Dislocation is a major complication following total hip arthroplasty, with risk factors such as surgical technique, implant positioning, and implant design. Literature has suggested the distance the femoral head must travel before dislocation to be a predictive factor of dislocation where smaller travel distance has increased dislocation risk. The purpose of this study was to compare 3 designs (hemispherical, metal-on-metal, and dual mobility [DM]) in terms of the dynamic dislocation distance and force required to dislocate. METHODS: This dynamic dislocation distance model used a material testing system that defined acetabular component inclination (30°, 45°, and 60°), anteversion angles (0°, 15°, and 30°), and pelvic tilt (5° [standing] and 26° [chair rise]). Testing groups included a hemispherical shell with a modular polyethylene liner and 32-mm head, a metal-on-metal hip resurfacing cup design with a 40-mm CoCr head, and a DM design with a 42-mm outside diameter articulating liner and an inner 28-mm articulating head. RESULTS: The dynamic dislocation distance of the DM hip was greater than that of the other designs for all inclination, anteversion, and pelvic tilt angles tested with the exception of 60° inclination/0° anteversion. At 26° pelvic tilt, it was observed that dislocation distance increased with greater anteversion and decreased with larger inclination. CONCLUSION: Clinical results have shown the DM design may reduce dislocation. These data support those findings and suggest that if instability is a concern preoperatively or intraoperatively, using a DM implant increases the dynamic dislocation distance.


Assuntos
Artroplastia de Quadril/instrumentação , Luxação do Quadril/etiologia , Prótese de Quadril/efeitos adversos , Desenho de Prótese , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Cabeça do Fêmur/cirurgia , Humanos , Modelos Teóricos , Polietileno , Postura , Amplitude de Movimento Articular , Fatores de Risco
16.
J Knee Surg ; 32(3): 239-250, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29715696

RESUMO

This study determined if robotic-arm assisted total knee arthroplasty (RATKA) allows for more accurate and precise bone cuts and component position to plan compared with manual total knee arthroplasty (MTKA). Specifically, we assessed the following: (1) final bone cuts, (2) final component position, and (3) a potential learning curve for RATKA. On six cadaver specimens (12 knees), a MTKA and RATKA were performed on the left and right knees, respectively. Bone-cut and final-component positioning errors relative to preoperative plans were compared. Median errors and standard deviations (SDs) in the sagittal, coronal, and axial planes were compared. Median values of the absolute deviation from plan defined the accuracy to plan. SDs described the precision to plan. RATKA bone cuts were as or more accurate to plan based on nominal median values in 11 out of 12 measurements. RATKA bone cuts were more precise to plan in 8 out of 12 measurements (p ≤ 0.05). RATKA final component positions were as or more accurate to plan based on median values in five out of five measurements. RATKA final component positions were more precise to plan in four out of five measurements (p ≤ 0.05). Stacked error results from all cuts and implant positions for each specimen in procedural order showed that RATKA error was less than MTKA error. Although this study analyzed a small number of cadaver specimens, there were clear differences that separated these two groups. When compared with MTKA, RATKA demonstrated more accurate and precise bone cuts and implant positioning to plan.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Procedimentos Cirúrgicos Robóticos , Idoso , Idoso de 80 Anos ou mais , Cadáver , Humanos , Articulação do Joelho/fisiopatologia , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular/fisiologia , Reprodutibilidade dos Testes
17.
J Knee Surg ; 32(8): 742-749, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30112739

RESUMO

Although several studies highlight the advantages of robotic arm-assisted total knee arthroplasty (RA-TKA), few investigate its intraoperative outcome. Therefore, the purpose of this study was to analyze the RA-TKA's ability to assist with intraoperative correction of: (1) flexion and (2) extension gaps, as well as its ability to (3) accurately predict implant sizes. Additionally, in this RA-TKA cohort, length of stay, complications, and readmissions were assessed. A total of 335 patients who underwent RA-TKA were included. The robotic software virtually measured the intraoperative prebone cut extension and flexion gaps. Differences in medial versus lateral prebone cut extension and flexion gaps were calculated. A total of 155 patients (46%) had an extension gap difference of between -2 and 2 mm (mean, -0.3 mm), while 119 patients (36%) had a flexion gap difference of between -2 and 2 mm (mean, -0.6 mm). Postbone cut differences in medial versus lateral flexion and extension gaps were measured. Balanced knees were considered to have a medial and lateral flexion gap difference within 2 mm. The robot-predicted implant size was also compared with the final implant size. Additionally, lengths of stay, complications, and readmissions were assessed. All patients achieved a postbone cut extension gap difference between -1 and 1 mm (mean, -0.1 mm). A total of 332 patients (99%) achieved a postbone cut flexion gap difference of between -2 and 2 mm (mean, 0 mm). For 98% of prostheses, the robotic software predicted within 1 implant size the actual tibial or femoral implant size used.The mean length of stay was found to be 2 days. No patients suffered from superficial skin infection, pin site infections or fractures, soft tissue damage, and no robotic cases were converted to manual TKA due to intraoperative complications. A total of 8 patients (2.2%) were readmitted; however, none were directly related to robotic use. The robotic software and use of a preoperative computed tomography (CT) substantially helped with intraoperative planning and accurate prediction of implant sizes. Therefore, based on the results of this study, the RA-TKA device does, in fact, provide considerable intraoperative assistance.


Assuntos
Artroplastia do Joelho/instrumentação , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/estatística & dados numéricos , Feminino , Fêmur/cirurgia , Humanos , Complicações Intraoperatórias/etiologia , Joelho/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Prótese do Joelho , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Readmissão do Paciente , Complicações Pós-Operatórias/etiologia , Amplitude de Movimento Articular , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Robótica , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
18.
J Biomech ; 82: 251-258, 2019 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-30501911

RESUMO

BACKGROUND: Mechanically-assisted crevice corrosion of modular tapers continues to be a concern in total joint replacements. Surgical factors that may affect taper seating mechanics include seating load magnitude and load orientation. Seating mechanics is defined as the seating load versus displacement behavior. In this study, mixed-alloy (CoCrMo/Ti-6Al-4V) modular head-neck 5°40' taper junctions were seated over a range of axially-oriented loads and off-axis orientations, capturing load-displacement during seating. The goals of the study were to assess the effects of seating load magnitude and load orientation on seating mechanics and correlate those findings with the taper pull-off load. METHODS: A testing fixture measured head-neck seating displacement as the load was quasistatically applied. Motion was captured using two non-contact differential variable reluctance transducers which were mounted to the neck targeting the head. Seating experiments ranged from 1000 N to 8000 N. Load orientation ranged from 0° to 20° at 4000 N. RESULTS: Seating load-displacement behavior at different seating loads showed a consistent characteristic behavior. Testing demonstrated increased seating displacement with seating load. Pull-off loads increased with seating load and were approximately 44% of the seating load across the range of seating loads investigated. Seating load orientation up to 20° had no significant effect on seating displacement and taper pull-off load. CONCLUSION: Increased seating load magnitude increased seating displacement, work of seating and pull-off loads in mixed-alloy 5°40' head-neck tapers. Altering load orientation up to 20° off-axis had no significant effect. Direct measurements of seating mechanics provides insights into the locking of taper junctions.


Assuntos
Ligas , Artroplastia de Substituição/instrumentação , Corrosão , Teste de Materiais , Desenho de Prótese , Falha de Prótese , Suporte de Carga
19.
Surg Technol Int ; 33: 337-342, 2018 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-30326136

RESUMO

BACKGROUND: Preoperative templating of total knee arthroplasty (TKA) components can help in choosing appropriate implant size prior to surgery. While long limb radiographs have been shown to be beneficial in assessing alignment, disease state, and previous pathology or trauma, their accuracy for size prediction has not been proven. In an attempt to improve templating precision, surgeons have looked to develop other predictive models for component size determination utilizing patient characteristics. The purpose of this study was to: 1) Identify which patient characteristics influence the tibial and femoral component sizes; 2) Construct models for size prediction; 3) Test the generated models at five different centers; and 4) Compare implant survivorship and patient characteristics between those who did or did not receive an implant within one size of the prediction. MATERIALS AND METHODS: Demographic data was collected on 741 patients (845 knees) as part of a multicenter clinical trial. Correlation between component size and patient demographic data were examined using Pearson coefficients, and significant variables were included into a multivariate-linear-regression model to determine "predicted size." Operative surgeon notes and postoperative radiographs were used to determine "actual size." Predictive equations were constructed for both femoral and tibial components and were tested at five different centers. Implant survivorship and patient characteristics were compared between those who did and did not receive an implant within one size of the prediction. RESULTS: The strongest predictors of component size were height, weight, and gender (p<0.01), followed by ethnicity (p=0.03) and age (p=0.03). Predictive equations were constructed for both tibial and femoral components. The model predicted the component fit within one size in 94% (r2=0.68) and 96% (r2=0.73) of femoral and tibial components. Cases beyond ±1 sizes did not have notable device-specific adverse events with Kaplan-Meier survivorship of 100% at five years. CONCLUSION: Demographic models are an effective tool in component size prediction prior to TKA. This model has implications in reducing the need for preoperative radiographic templating, potentially resulting in increasing surgeon efficiency and possibly reducing hospital implant inventory. This may be particularly important for ambulatory or outpatient surgery centers.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/estatística & dados numéricos , Articulação do Joelho/cirurgia , Prótese do Joelho/estatística & dados numéricos , Modelos Estatísticos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Proc Inst Mech Eng H ; 232(9): 862-870, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30238861

RESUMO

Assembly of a femoral head onto the stem remains non-standardized. The literature shows altering mechanical conditions during seating affects taper strength and lower assembly load may increase fretting corrosion during cyclic tests. This suggests overall performance may be affected by head assembly method. The purpose of this test was to perform bench-top studies to determine influence of peak force magnitude, load rate, and compliance of the system's support structure on initial stability of the taper. Custom manufactured CoCrMo femoral heads and Ti-6Al-4V taper analog samples were assembled with varying peak force magnitudes (2-10.1 kN), load rates (quasi-static vs impaction), and system compliance (rigid vs compliant). A clinically-relevant system compliance design was based off of force data collected during a cadaver impaction study. Tensile loads were then applied to disassemble the taper and quantify initial taper stability. Results indicated that taper stability (assessed by disassembly forces) increased linearly with assembly force and load rate did not have a significant effect on taper stability. When considering system compliance, a 42%-50% larger input energy, dependent on assembly force, was required in the compliant group to achieve a comparable impaction force to the rigid group. Even when this impaction force was achieved, the correlation between the coefficient, defined as distraction force divided by assembly load, was significantly reduced for the compliant test group. The compliant setup was intended to simulate a surgical scenario where patient and surgical factors may influence the resulting compliance. Based on results, surgical procedure and patient variables may have a significant effect on initial taper stability.


Assuntos
Prótese de Quadril , Teste de Materiais , Fenômenos Mecânicos , Ligas , Titânio , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...