Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(4): 043102, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35489906

RESUMO

We report the development of a multipurpose differential x-ray calorimeter with a broad energy bandwidth. The absorber architecture is combined with a Bayesian unfolding algorithm to unfold high energy x-ray spectra generated in high-intensity laser-matter interactions. Particularly, we show how to extract absolute energy spectra and how our unfolding algorithm can reconstruct features not included in the initial guess. The performance of the calorimeter is evaluated via Monte Carlo generated data. The method accuracy to reconstruct electron temperatures from bremsstrahlung is shown to be 5% for electron temperatures from 1 to 50 MeV. We study bremsstrahlung generated in solid target interaction showing an electron temperature of 0.56 ± 0.04 MeV for a 700 µm Ti titanium target and 0.53 ± 0.03 MeV for a 50 µm target. We investigate bremsstrahlung from a target irradiated by laser-wakefield accelerated electrons showing an endpoint energy of 551 ± 5 MeV, inverse Compton generated x rays with a peak energy of 1.1 MeV, and calibrated radioactive sources. The total energy range covered by all these sources ranges from 10 keV to 551 MeV.

2.
Sci Rep ; 11(1): 14368, 2021 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-34257331

RESUMO

We reconstruct spectra of secondary X-rays from a tunable 250-350 MeV laser wakefield electron accelerator from single-shot X-ray depth-energy measurements in a compact (7.5 × 7.5 × 15 cm), modular X-ray calorimeter made of alternating layers of absorbing materials and imaging plates. X-rays range from few-keV betatron to few-MeV inverse Compton to > 100 MeV bremsstrahlung emission, and are characterized both individually and in mixtures. Geant4 simulations of energy deposition of single-energy X-rays in the stack generate an energy-vs-depth response matrix for a given stack configuration. An iterative reconstruction algorithm based on analytic models of betatron, inverse Compton and bremsstrahlung photon energy distributions then unfolds X-ray spectra, typically within a minute. We discuss uncertainties, limitations and extensions of both measurement and reconstruction methods.

3.
Nat Commun ; 12(1): 2895, 2021 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-34001874

RESUMO

Plasma wakefield accelerators are capable of sustaining gigavolt-per-centimeter accelerating fields, surpassing the electric breakdown threshold in state-of-the-art accelerator modules by 3-4 orders of magnitude. Beam-driven wakefields offer particularly attractive conditions for the generation and acceleration of high-quality beams. However, this scheme relies on kilometer-scale accelerators. Here, we report on the demonstration of a millimeter-scale plasma accelerator powered by laser-accelerated electron beams. We showcase the acceleration of electron beams to 128 MeV, consistent with simulations exhibiting accelerating gradients exceeding 100 GV m-1. This miniaturized accelerator is further explored by employing a controlled pair of drive and witness electron bunches, where a fraction of the driver energy is transferred to the accelerated witness through the plasma. Such a hybrid approach allows fundamental studies of beam-driven plasma accelerator concepts at widely accessible high-power laser facilities. It is anticipated to provide compact sources of energetic high-brightness electron beams for quality-demanding applications such as free-electron lasers.

4.
Sci Rep ; 11(1): 7338, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33795713

RESUMO

We report on experimental investigations of proton acceleration from solid foils irradiated with PW-class laser-pulses, where highest proton cut-off energies were achieved for temporal pulse parameters that varied significantly from those of an ideally Fourier transform limited (FTL) pulse. Controlled spectral phase modulation of the driver laser by means of an acousto-optic programmable dispersive filter enabled us to manipulate the temporal shape of the last picoseconds around the main pulse and to study the effect on proton acceleration from thin foil targets. The results show that applying positive third order dispersion values to short pulses is favourable for proton acceleration and can lead to maximum energies of 70 MeV in target normal direction at 18 J laser energy for thin plastic foils, significantly enhancing the maximum energy compared to ideally compressed FTL pulses. The paper further proves the robustness and applicability of this enhancement effect for the use of different target materials and thicknesses as well as laser energy and temporal intensity contrast settings. We demonstrate that application relevant proton beam quality was reliably achieved over many months of operation with appropriate control of spectral phase and temporal contrast conditions using a state-of-the-art high-repetition rate PW laser system.

5.
Phys Rev Lett ; 125(1): 014801, 2020 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-32678646

RESUMO

We report observations of coherent optical transition radiation interferometry (COTRI) patterns generated by microbunched ∼200-MeV electrons as they emerge from a laser-driven plasma accelerator. The divergence of the microbunched portion of electrons, deduced by comparison to a COTRI model, is ∼9× smaller than the ∼3 mrad ensemble beam divergence, while the radius of the microbunched beam, obtained from COTR images on the same shot, is <3 µm. The combined results show that the microbunched distribution has estimated transverse normalized emittance ∼0.4 mm mrad.

6.
Sci Rep ; 10(1): 5634, 2020 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-32221373

RESUMO

Femtosecond (fs) x-ray pulses are a key tool to study the structure and dynamics of matter on its natural length and time scale. To complement radio-frequency accelerator-based large-scale facilities, novel laser-based mechanisms hold promise for compact laboratory-scale x-ray sources. Laser-plasma driven undulator radiation in particular offers high peak-brightness, optically synchronized few-fs pulses reaching into the few-nanometer (nm) regime. To date, however, few experiments have successfully demonstrated plasma-driven undulator radiation. Those that have, typically operated at single and comparably long wavelengths. Here we demonstrate plasma-driven undulator radiation with octave-spanning tuneability at discrete wavelengths reaching from 13 nm to 4 nm. Studying spontaneous undulator radiation is an important step towards a plasma-driven free-electron laser. Our specific setup creates a photon pulse, which closely resembles the plasma electron bunch length and charge profile and thus might enable novel methods to characterize the longitudinal electron phase space.

7.
Philos Trans A Math Phys Eng Sci ; 377(2151): 20180175, 2019 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-31230579

RESUMO

We present a conceptual design for a hybrid laser-driven plasma wakefield accelerator (LWFA) to beam-driven plasma wakefield accelerator (PWFA). In this set-up, the output beams from an LWFA stage are used as input beams of a new PWFA stage. In the PWFA stage, a new witness beam of largely increased quality can be produced and accelerated to higher energies. The feasibility and the potential of this concept is shown through exemplary particle-in-cell simulations. In addition, preliminary simulation results for a proof-of-concept experiment in Helmholtz-Zentrum Dresden-Rossendorf (Germany) are shown. This article is part of the Theo Murphy meeting issue 'Directions in particle beam-driven plasma wakefield acceleration'.

8.
Rev Sci Instrum ; 89(9): 093304, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30278706

RESUMO

This article reports on the development of thin diamond detectors and their characterization for their application in temporal profile measurements of subnanosecond ion bunches. Two types of diamonds were used: a 20 µm thin polycrystalline chemical vapor deposited (CVD) diamond and a membrane with a thickness of (5 ± 1) µm etched out of a single crystal (sc) CVD diamond. The combination of a small detector electrode and an impedance matched signal outlet leads to excellent time response properties with a signal pulse resolution (FWHM) of τ = (113 ± 11) ps. Such a fast diamond detector is a perfect device for the time of flight measurements of MeV ions with bunch durations in the subnanosecond regime. The scCVD diamond membrane detector was successfully implemented within the framework of the laser ion generation handling and transport project, in which ion beams are accelerated via a laser-driven source and shaped with conventional accelerator technology. The detector was used to measure subnanosecond proton bunches with an intensity of 108 protons per bunch.

9.
Sci Rep ; 8(1): 1398, 2018 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-29362472

RESUMO

Interaction of relativistic electron beams with high power lasers can both serve as a secondary light source and as a novel diagnostic tool for various beam parameters. For both applications, it is important to understand the dynamics of the inverse Compton scattering mechanism and the dependence of the scattered light's spectral properties on the interacting laser and electron beam parameters. Measurements are easily misinterpreted due to the complex interplay of the interaction parameters. Here we report the potential of inverse Compton scattering as an advanced diagnostic tool by investigating two of the most influential interaction parameters, namely the laser intensity and the electron beam emittance. Established scaling laws for the spectral bandwidth and redshift of the mean scattered photon energy are refined. This allows for a quantitatively well matching prediction of the spectral shape. Driving the interaction to a nonlinear regime, we spectrally resolve the rise of higher harmonic radiation with increasing laser intensity. Unprecedented agreement with 3D radiation simulations is found, showing the good control and characterization of the interaction. The findings advance the interpretation of inverse Compton scattering measurements into a diagnostic tool for electron beams from laser plasma acceleration.

10.
Nat Commun ; 9(1): 423, 2018 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-29379024

RESUMO

Often, the interpretation of experiments concerning the manipulation of the energy distribution of laser-accelerated ion bunches is complicated by the multitude of competing dynamic processes simultaneously contributing to recorded ion signals. Here we demonstrate experimentally the acceleration of a clean proton bunch. This was achieved with a microscopic and three-dimensionally confined near critical density plasma, which evolves from a 1 µm diameter plastic sphere, which is levitated and positioned with micrometer precision in the focus of a Petawatt laser pulse. The emitted proton bunch is reproducibly observed with central energies between 20 and 40 MeV and narrow energy spread (down to 25%) showing almost no low-energetic background. Together with three-dimensional particle-in-cell simulations we track the complete acceleration process, evidencing the transition from organized acceleration to Coulomb repulsion. This reveals limitations of current high power lasers and viable paths to optimize laser-driven ion sources.

11.
Nat Commun ; 8(1): 487, 2017 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-28887456

RESUMO

Laser-plasma wakefield accelerators have seen tremendous progress, now capable of producing quasi-monoenergetic electron beams in the GeV energy range with few-femtoseconds bunch duration. Scaling these accelerators to the nanocoulomb range would yield hundreds of kiloamperes peak current and stimulate the next generation of radiation sources covering high-field THz, high-brightness X-ray and γ-ray sources, compact free-electron lasers and laboratory-size beam-driven plasma accelerators. However, accelerators generating such currents operate in the beam loading regime where the accelerating field is strongly modified by the self-fields of the injected bunch, potentially deteriorating key beam parameters. Here we demonstrate that, if appropriately controlled, the beam loading effect can be employed to improve the accelerator's performance. Self-truncated ionization injection enables loading of unprecedented charges of ∼0.5 nC within a mono-energetic peak. As the energy balance is reached, we show that the accelerator operates at the theoretically predicted optimal loading condition and the final energy spread is minimized.Higher beam quality and stability are desired in laser-plasma accelerators for their applications in compact light sources. Here the authors demonstrate in laser plasma wakefield electron acceleration that the beam loading effect can be employed to improve beam quality by controlling the beam charge.

12.
Phys Med Biol ; 62(13): 5531-5555, 2017 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-28609301

RESUMO

Proton beams may provide superior dose-conformity in radiation therapy. However, the large sizes and costs limit the widespread use of proton therapy (PT). The recent progress in proton acceleration via high-power laser systems has made it a compelling alternative to conventional accelerators, as it could potentially reduce the overall size and cost of the PT facilities. However, the laser-accelerated beams exhibit different characteristics than conventionally accelerated beams, i.e. very intense proton bunches with large divergences and broad-energy spectra. For the application of laser-driven beams in PT, new solutions for beam transport, such as beam capture, integrated energy selection, beam shaping and delivery systems are required due to the specific beam parameters. The generation of these beams are limited by the low repetition rate of high-power lasers and this limitation would require alternative solutions for tumour irradiation which can efficiently utilize the available high proton fluence and broad-energy spectra per proton bunch to keep treatment times short. This demands new dose delivery system and irradiation field formation schemes. In this paper, we present a multi-functional light-weight and compact proton gantry design for laser-driven sources based on iron-less pulsed high-field magnets. This achromatic design includes improved beam capturing and energy selection systems, with a novel beam shaping and dose delivery system, so-called ELPIS. ELPIS system utilizes magnetic fields, instead of physical scatterers, for broadening the spot-size of broad-energetic beams while capable of simultaneously scanning them in lateral directions. To investigate the clinical feasibility of this gantry design, we conducted a treatment planning study with a 3D treatment planning system augmented for the pulsed beams with optimizable broad-energetic widths and selectable beam spot sizes. High quality treatment plans could be achieved with such unconventional beam parameters, deliverable via the presented gantry and ELPIS dose delivery system. The conventional PT gantries are huge and require large space for the gantry to rotate the beam around the patient, which could be reduced up to 4 times with the presented pulse powered gantry system. The further developments in the next generation petawatt laser systems and laser-targets are crucial to reach higher proton energies. However, if proton energies required for therapy applications are reached it could be possible in future to reduce the footprint of the PT facilities, without compromising on clinical standards.


Assuntos
Lasers , Aceleradores de Partículas , Terapia com Prótons/instrumentação , Humanos , Modelos Teóricos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
13.
Phys Rev Lett ; 118(19): 194801, 2017 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-28548516

RESUMO

We report experimental evidence that multi-MeV protons accelerated in relativistic laser-plasma interactions are modulated by strong filamentary electromagnetic fields. Modulations are observed when a preplasma is developed on the rear side of a µm-scale solid-density hydrogen target. Under such conditions, electromagnetic fields are amplified by the relativistic electron Weibel instability and are maximized at the critical density region of the target. The analysis of the spatial profile of the protons indicates the generation of B>10 MG and E>0.1 MV/µm fields with a µm-scale wavelength. These results are in good agreement with three-dimensional particle-in-cell simulations and analytical estimates, which further confirm that this process is dominant for different target materials provided that a preplasma is formed on the rear side with scale length ≳0.13λ_{0}sqrt[a_{0}]. These findings impose important constraints on the preplasma levels required for high-quality proton acceleration for multipurpose applications.

14.
Phys Rev E ; 96(1-1): 013316, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29347084

RESUMO

For the relativistic Kelvin-Helmholtz instability (KHI), which occurs at shear interfaces between two plasma streams, we report results on the polarized radiation over all observation directions and frequencies emitted by the plasma electrons from ab initio kinetic simulations. We find the polarization of the radiation to provide a clear signature for distinguishing the linear phase of the KHI from its other phases. During the linear phase, we predict the growth rate of the KHI radiation power to match the growth rate of the KHI to a high degree. Our predictions are based on a model of the vortex dynamics, which describes the electron motion in the vicinity of the shear interface between the two streams. Albeit the complex and turbulent dynamics happening in the shear region, we find excellent agreement between our model and large-scale particle-in-cell simulations. Our findings pave the way for identifying the KHI linear regime and for measuring its growth rate in astrophysical jets observable on earth as well as in laboratory plasmas.

15.
Rev Sci Instrum ; 87(8): 083310, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27587116

RESUMO

In this paper, a scintillator-based online beam profile detector for the characterization of laser-driven proton beams is presented. Using a pixelated matrix with varying absorber thicknesses, the proton beam is spatially resolved in two dimensions and simultaneously energy-resolved. A thin plastic scintillator placed behind the absorber and read out by a CCD camera is used as the active detector material. The spatial detector resolution reaches down to ∼4 mm and the detector can resolve proton beam profiles for up to 9 proton threshold energies. With these detector design parameters, the spatial characteristics of the proton distribution and its cut-off energy can be analyzed online and on-shot under vacuum conditions. The paper discusses the detector design, its characterization and calibration at a conventional proton source, as well as the first detector application at a laser-driven proton source.

16.
Sci Rep ; 6: 22256, 2016 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-26924651

RESUMO

Ultrashort flashes of THz light with low photon energies of a few meV, but strong electric or magnetic field transients have recently been employed to prepare various fascinating nonequilibrium states in matter. Here we present a new class of sources based on superradiant enhancement of radiation from relativistic electron bunches in a compact electron accelerator that we believe will revolutionize experiments in this field. Our prototype source generates high-field THz pulses at unprecedented quasi-continuous-wave repetition rates up to the MHz regime. We demonstrate parameters that exceed state-of-the-art laser-based sources by more than 2 orders of magnitude. The peak fields and the repetition rates are highly scalable and once fully operational this type of sources will routinely provide 1 MV/cm electric fields and 0.3 T magnetic fields at repetition rates of few 100 kHz. We benchmark the unique properties by performing a resonant coherent THz control experiment with few 10 fs resolution.

17.
Phys Med ; 30(3): 255-70, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24100298

RESUMO

Suitable instrumentation for laser-accelerated proton (ion) beams is critical for development of integrated, laser-driven ion accelerator systems. Instrumentation aimed at beam diagnostics and control must be applied to the driving laser pulse, the laser-plasma that forms at the target and the emergent proton (ion) bunch in a correlated way to develop these novel accelerators. This report is a brief overview of established diagnostic techniques and new developments based on material presented at the first workshop on 'Instrumentation for Diagnostics and Control of Laser-accelerated Proton (Ion) Beams' in Abingdon, UK. It includes radiochromic film (RCF), image plates (IP), micro-channel plates (MCP), Thomson spectrometers, prompt inline scintillators, time and space-resolved interferometry (TASRI) and nuclear activation schemes. Repetition-rated instrumentation requirements for target metrology are also addressed.


Assuntos
Lasers , Aceleradores de Partículas/instrumentação , Prótons , Análise Espectral
18.
Phys Rev Lett ; 111(21): 219502, 2013 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-24313535
19.
Phys Rev Lett ; 111(11): 114803, 2013 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-24074095

RESUMO

Thomson backscattering of intense laser pulses from relativistic electrons not only allows for the generation of bright x-ray pulses but also for the investigation of the complex particle dynamics at the interaction point. For this purpose a complete spectral characterization of a Thomson source powered by a compact linear electron accelerator is performed with unprecedented angular and energy resolution. A rigorous statistical analysis comparing experimental data to 3D simulations enables, e.g., the extraction of the angular distribution of electrons with 1.5% accuracy and, in total, provides predictive capability for the future high brightness hard x-ray source PHOENIX (photon electron collider for narrow bandwidth intense x rays) and potential gamma-ray sources.

20.
Gesundheitswesen ; 75(5): 328-33, 2013 May.
Artigo em Alemão | MEDLINE | ID: mdl-22932828

RESUMO

AIM OF THE STUDY: Analysis of views of general practioners and nurses of interprofessional cooperation between general practititoners and nurses in the ambulatory care of dementia patients is presented. METHODS: A survey was carried out among general practitioners and nurses caring for community dwelling dementia patients in Hamburg. RESULTS: The majority of GPs and nurses consider interprofessional cooperation to be good and beneficial for their own work. GPs are generally more positive about the quality of cooperation than nurses. Joint sessions for planning and evaluation of care are seldom. Even so, more GPs than nurses evaluate the frequency of these meetings to be sufficient. Although nurses are more critical about the quality of the cooperation with the GPs, they seldom address the GP to express their criticism. CONSEQUENCES: To make cooperation work, the matter should be part of the training of both physicians and nurses and the hierarchy between the 2 groups should be reduced.


Assuntos
Atitude do Pessoal de Saúde , Demência/enfermagem , Clínicos Gerais/estatística & dados numéricos , Serviços de Assistência Domiciliar/estatística & dados numéricos , Relações Interprofissionais , Satisfação no Emprego , Enfermeiros de Saúde Comunitária/estatística & dados numéricos , Adulto , Assistência Ambulatorial/estatística & dados numéricos , Comportamento Cooperativo , Enfermagem de Cuidados Críticos/estatística & dados numéricos , Coleta de Dados , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...