Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
CVIR Endovasc ; 6(1): 55, 2023 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-37950835

RESUMO

BACKGROUND: Endobronchial forceps are commonly used for complex IVC filter removal and after initial attempts at IVC filter retrieval with a snare have failed. Currently, there are no clear guidelines to help distinguish cases where primary removal should be attempted with standard snare technique or whether attempts at removal should directly be started with forceps. This study is aimed to identify clinical and imaging predictors of snare failure which necessitate conversion to endobronchial forceps. METHODS: Retrospective analysis of 543 patients who underwent IVC filter retrievals were performed at three large quaternary care centers from Jan 2015 to Jan 2022. Patient demographics and IVC filter characteristics on cross-sectional images (degree of tilt, hook embedment, and strut penetration, etc.) were reviewed. Binary multivariate logistic regression was used to identify predictors of IVC filter retrieval where snare retrieval would fail. RESULTS: Thirty seven percent of the patients (n = 203) necessitated utilization of endobronchial forceps. IVC filter hook embedment (OR:4.55; 95%CI: 1.74-11.87; p = 0.002) and strut penetration (OR: 56.46; 95% CI 20.2-157.7; p = 0.001) were predictors of snare failure. In contrast, total dwell time, BMI, and degree of filter tilt were not associated with snare failure. Intraprocedural conversion from snare to endobronchial forceps was significantly associated with increased contrast volume, radiation dose, and total procedure times (p < 0.05). CONCLUSION: IVC filter hook embedment and strut penetration were predictors of snare retrieval failure. Intraprocedural conversion from snare to endobronchial forceps increased contrast volume, radiation dose, and total procedure time. When either hook embedment or strut penetration is present on pre-procedural cross-sectional images, IVC filter retrieval should be initiated using endobronchial forceps. LEVEL OF EVIDENCE: Level 3, large multicenter retrospective cohort.

2.
CVIR Endovasc ; 5(1): 39, 2022 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-35932376

RESUMO

BACKGROUND: Inferior vena cava (IVC) filter retrieval is typically accomplished with standard snare technique. When this fails, more advanced techniques are necessary, especially when removal falls outside a 12-month window. Complications during filter retrieval depend heavily on technique, type of filter, and filter position. In this study we examined safety and efficacy of 536 filter retrievals at a tertiary care center and compared complication rates between standard snare and endobronchial forcep retrieval. METHOD: We reviewed 536 cases between August 2015 and August 2020, recording retrieval success rates, patient comorbidities, and complication rates at the time of removal. RESULTS: Total overall retrieval success was 97.9% (525/536), and complications occurred in approximately 6.0% (32/536) of all cases. Success and complications with standard snare technique alone were 99.4% (345/347) and 1.7% (5 Grade I/II, 1 Grade III) and advanced forcep technique 98.8% (171/173) and 14.5% (22 Grade I/II, 2 Grade III, and 1 Grade IV), respectively. There was no significant difference between the technical success rates of the standard snare technique and forceps techniques (p = 0.60) despite a significantly longer dwell time in patients undergoing forceps retrieval (p < 0.001). CONCLUSION: To our knowledge, this is the largest cohort of forceps directed IVC filter retrieval present in the literature. Rates of successful endobronchial forceps and standard snare retrievals in this study are similar to previous reports. Although use of endobronchial forceps may be associated with higher complication rates, this is likely due to prolonged dwell times, filter tilt, and attempted removal of non retrievable filters. Overall, forceps-directed retrieval offers a safe, effective means of removal in difficult cases. LEVEL OF EVIDENCE: Level 3, Large Retrospective Study.

3.
Diagn Interv Radiol ; 26(5): 464-469, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32755878

RESUMO

PURPOSE: The role of computed tomography (CT)-guided gastrostomy tube placement is still evolving. It is a valuable alternative to guide gastrostomy tube placement in a few selected patients, who are not candidates for the established endoscopy- or fluoroscopy-guided gastrostomy tube placement. Our objective was to describe our institutional experience placing gastrostomy tubes using CT guidance and to conduct a review of literature for similar studies to provide the best current evidence on success rates and complications. METHODS: We identified gastrostomy tubes placed under CT guidance at our institution using a comprehensive case log. We also identified studies in the literature, through a systematic search of PubMed. In both the local and literature analyses, we recorded success and complication rates. RESULTS: A total of 31 patients underwent 33 attempted CT-guided gastrostomy tube placements at our institution, with 32 successful procedures yielding a success rate of 97%. The overall rate of successful gastrostomy tube placement using CT-guidance was 94.9% (634/668), as reported in the existing literature. CONCLUSION: CT-guidance is an effective method for gastrostomy tube placement and may play an important role in patients for whom endoscopic or fluoroscopic gastrostomy tube placement is not feasible.


Assuntos
Gastrostomia , Tomografia Computadorizada por Raios X , Cateterismo , Fluoroscopia , Humanos , Estudos Retrospectivos
4.
World J Radiol ; 11(9): 116-125, 2019 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-31608143

RESUMO

BACKGROUND: Primary appendiceal cancers are rare, and they generally present with liver and/or peritoneal metastases. Currently there are no guidelines to treat metastatic appendiceal cancer, and hence they are treated as metastatic colorectal cancer. Combining Yttrium 90 (Y-90) radioembolization (RE) with systemic chemotherapy early in the treatment of right sided colon cancers has been shown to improve survival. Based on this data, a combination of systemic chemotherapy and Y-90 RE was used to treat a case of metastatic appendiceal cancer. CASE SUMMARY: A 76-year-old male presented to the emergency room with progressive right lower quadrant pain. A Computed Tomography of the abdomen and pelvis was performed which showed acute appendicitis and contained perforation. Urgent laparoscopic appendectomy was then followed by histological analysis, which was significant for appendiceal adenocarcinoma. After complete workup he underwent right hemicolectomy and lymph node dissection. He received adjuvant chemotherapy as the local lymph nodes were positive. Follow-up imaging was significant for liver metastasis. Due to rapid growth of the liver lesions and new peritoneal nodules, the patient was treated with a combination of Y-90 RE and folinic acid, fluorouracil, and irinotecan with bevacizumab and not microwave ablation as previously planned. Follow up imaging demonstrated complete response of the liver lesions. At 12-mo follow-up, the patient continued to enjoy good quality of life with no recurrent disease. CONCLUSION: Utilization of Y-90 RE concomitantly with systemic chemotherapy early in the treatment of appendiceal cancer may provide improved control of this otherwise aggressive cancer.

5.
Indian J Radiol Imaging ; 29(4): 391-396, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31949341

RESUMO

BACKGROUND: Inferior vena cava (IVC) filter placement still plays an essential role in preventing pulmonary embolism (PE) in patients with contraindications to anticoagulant therapy. However, IVC filter placement does have long-term risks which may be mitigated by retrieving them as soon as clinically acceptable. A dedicated IVC filter clinic provides a potential means of assuring adequate follow-up and retrieval. AIM: To assess the efficacy of our Inferior vena cava (IVC) filter retrieval clinic at improving the rate of patient follow-up, effective filter management, and retrieval rates. MATERIALS AND METHODS: During the period of August 2017 through July 2018, 70 IVC filters were placed at our institution, and these patients were automatically enrolled into our IVC filter retrieval clinic for quarterly follow-up. We retrospectively reviewed data including appropriateness for removal at 3 months, overall retrieval rates, removal technique(s) employed, and technical success. RESULTS: 62.9% of the potentially retrievable filters were removed during the study period. The technical success of extraction, using a combination of standard and advanced techniques, was 91.7%. Overall, 15% of the patients were lost to follow-up. CONCLUSION: Our findings add to the growing body of literature to support the need for a robust IVC filter retrieval clinic to ensure adequate follow-up and timely retrieval of IVC filters.

6.
IEEE Trans Vis Comput Graph ; 19(5): 886-96, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22868674

RESUMO

Spatial judgments are important for many real-world tasks in engineering and scientific visualization. While existing research provides evidence that higher levels of display and interaction fidelity in virtual reality systems offer advantages for spatial understanding, few investigations have focused on small-scale spatial judgments or employed experimental tasks similar to those used in real-world applications. After an earlier study that considered a broad analysis of various spatial understanding tasks, we present the results of a follow-up study focusing on small-scale spatial judgments. In this research, we independently controlled field of regard, stereoscopy, and head-tracked rendering to study their effects on the performance of a task involving precise spatial inspections of complex 3D structures. Measuring time and errors, we asked participants to distinguish between structural gaps and intersections between components of 3D models designed to be similar to real underground cave systems. The overall results suggest that the addition of the higher fidelity system features support performance improvements in making small-scale spatial judgments. Through analyses of the effects of individual system components, the experiment shows that participants made significantly fewer errors with either an increased field of regard or with the addition of head-tracked rendering. The results also indicate that participants performed significantly faster when the system provided the combination of stereo and head-tracked rendering.


Assuntos
Sinais (Psicologia) , Percepção de Profundidade/fisiologia , Movimentos da Cabeça/fisiologia , Orientação/fisiologia , Desempenho Psicomotor/fisiologia , Percepção Espacial/fisiologia , Campos Visuais/fisiologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...