Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Heliyon ; 10(6): e28321, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38545195

RESUMO

This study evaluates masticatory efficiency in orthodontic patients with craniofacial disorders compared to controls without, considering the effect of an orthodontic appliance and malocclusion. A total of 119 participants (7-21 years), divided into a craniofacial disorder and control group (n = 42 and n = 77; mean age 13.5 ± 5.2 and 14.2 ± 3.3 years) were included. Masticatory efficiency was evaluated using a standard food model test, where masticated test food bodies were analyzed, and parameters like particle number (n) and area (mm2) were recorded. This study newly introduced the masticatory efficiency index (MEI), which encompasses the above terms (number and area), with a high MEI being an indicator of high masticatory ability. Younger orthodontic patients with a craniofacial disorder had a significantly decreased MEI (0.50 ± 0.25 n/mm2) compared to patients without (1.10 ± 0.48 n/mm2; p = 0.02). The presence of a crossbite significantly decreased masticatory efficiency, particularly in craniofacial disorder patients (0.69 ± 1.44 n/mm2) versus controls (0.89 ± 1.00 n/mm2, p = 0.04). As treatment progressed with age and fixed appliances, mastication group differences became non-significant, suggesting that patients with a craniofacial disorder were catching up to healthy controls in the rehabilitation of their masticatory function. Considering an early diagnosis of malocclusion during orthodontic therapy in combination with speech therapy can avoid negative malocclusion effects with growth, caused by muscle imbalances.

2.
Bioengineering (Basel) ; 11(1)2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38247968

RESUMO

Due to dental diseases, anatomical restrictions, and mixed dentition, the reduction in the number of teeth and the displacement of tooth germs pose challenges in orthodontic treatment, limiting anchorage options. The presented case demonstrates an advanced treatment solution using digital CAD/CAM-technologies and medical imaging for the creation of a mini-implant template. A 12-year-old male patient experiencing delayed tooth eruption, multiple impacted germs, and maxillary constriction underwent intraoral scanning and CBCT. Utilizing coDiagnostiXTM Version 10.2 software, the acquired data were merged to determine the mini-implant placement and to design the template. The template was then manufactured through stereolithography using surgical-guide material. Mini-implants were inserted using the produced appliance, enabling safe insertion by avoiding vital structures. Surgically exposed displaced teeth were aligned using a Hyrax screw appliance anchored on the mini-implants for rapid palatal expansion (RPE) and subsequently used as fixed orthodontics to align impacted teeth. The screw was activated daily for 10 weeks, resulting in a 7 mm posterior and 5 mm anterior maxillary transversal increase. Skeletal anchorage facilitated simultaneous RPE and tooth alignment, ensuring accuracy, patient safety, and appliance stability. The presented case shows a scenario in which computer-aided navigation for mini-implant positioning can enhance precision and versatility in challenging anatomical cases.

3.
J Pers Med ; 13(3)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36983646

RESUMO

For sinus grafting, different methods and materials are available. One possible shortcoming of particulate bone grafts is either overfilling or augmenting the planned implant area insufficiently. To overcome this risk and to determine the implant position prior augmentation, we present an approach using three-dimensional printed scaffolds. A patient with a remaining anterior dentition and bilateral severely atrophied posterior maxilla was seeking oral rehabilitation. The cone beam computed tomography (CBCT) showed residual bone heights between one and two millimeters. Following the three-dimensional reconstruction of the CBCT data, the positions of the implants were determined in areas 16 and 26. Three-dimensional scaffolds adapted to the topography of the sinus were virtually designed and printed using a calcium phosphate cement paste. Bilateral sinus floor augmentation applying the printed scaffolds with an interconnecting porosity followed. After nine months, a satisfying integration of the scaffolds was obvious. At the re-entry, vital bone with sufficient blood supply was found. One implant could be placed in positions 16 and 26, respectively. After five months, the implants could be uncovered and were provided with a temporary denture. The application of three-dimensionally printed scaffolds from calcium phosphate cement paste seems to be a promising technique to graft the severely atrophied posterior maxilla for the placement of dental implants.

4.
Artigo em Inglês | MEDLINE | ID: mdl-36901330

RESUMO

This study evaluates the masticatory efficiency in patients with craniofacial disorders (CD) compared to controls (C). A total of 119 participants (7-21 years), divided into CD group (n = 42, mean age 13.45 ± 5.2 years) and C group (n = 77, mean age 14.3 ± 3.27 years) under an orthodontic treatment were included. Masticatory efficiency was assessed using a standard food model test. The masticated food was examined according to its number of particles (n) and area (mm2), wherein a higher number of particles alongside a smaller area was an indication of better masticatory efficiency. Additionally, the influence of cleft formation, chewing side, dentition stage, age and sex were evaluated. Patients with CD chewed the standardized food in fewer particles (nCD = 61.76 vs. nC = 84.58), with a significantly higher amount of area than the controls (ACD = 192.91 mm2 vs. AC = 146.84 mm2; p = 0.04). In conclusion, patients with CD showed a significantly decreased mastication efficiency compared to healthy patients. Factors such as stage of cleft formation, chewing side, dentition stage and age showed an influence on masticatory efficiency, whereas no gender effect on the masticatory efficiency of CD patients was found.


Assuntos
Alimentos , Mastigação , Ortodontia , Adolescente , Criança , Humanos , Eficiência
5.
Ann Anat ; 248: 152082, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36913983

RESUMO

BACKGROUND: Education of undergraduates in implant dentistry has been extended. In order to assess the correct implant position, the accuracy of implant insertion using templates for pilot-drill guided and full-guided implant insertion was examined in a laboratory set-up in a cohort of undergraduates. METHODS: After three-dimensional planning of the implant position in partially edentulous mandibular models, individual templates for the pilot-drill guided or full-guided implant insertion in the region of the first premolar were produced. A total of 108 dental implants were inserted. The results of the radiographic evaluation of the three-dimensional accuracy were statistically analyzed. Furthermore, the participants completed a questionnaire. RESULTS: The deviation of the three-dimensional angle of the implants inserted fully guided was 2.74 ± 1.49 degrees compared to 4.59 ± 2.70 degrees for pilot-drill guided. The difference was statistically significant (p < 0.01). The returned questionnaires revealed a high interest in oral implantology and a positive evaluation of the hands-on course. CONCLUSIONS: In this study, the undergraduates benefited from applying full-guided implant insertion considering the accuracy in this laboratory examination. However, the clinical effects are not clear as the differences are within a small range. Based on the returned questionnaires, the implementation of practical courses in the undergraduate curriculum should be encouraged.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Humanos , Estudos Prospectivos , Estudantes de Odontologia , Cirurgia Assistida por Computador/métodos , Próteses e Implantes , Currículo , Implantação Dentária Endóssea , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico/métodos
6.
J Clin Med ; 12(2)2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36675376

RESUMO

BACKGROUND: To assess the long-term functional orthodontic outcome of the Tübingen palatal plate (TPP) in children with Robin sequence (RS) in comparison to age- and sex-matched healthy controls. METHODS: Between 09/2019 and 10/2020, we performed orthodontic assessments in 41 children at our Department of Orthodontics. Included were patients with RS (17 non-syndromic; four syndromic) and healthy controls (n = 22, average age in both groups 9.9 y). Facial analyses of 2D images, digital study casts and cephalometric measurements were made. RESULTS: The orthodontic examinations showed no statistically significant group differences regarding functional extraoral, intraoral and pharyngeal parameters, or in skeletal patterns. The relationship between the upper and lower incisors was significantly increased (overjet 4 (2-10) vs. 3 (0-9) mm; p = 0.01) with a significant deficit in the lower face proportions (Jaw Index 4.15 (1.9-9.6) vs. 2.98 (0-9); p = 0.02; Facial convexity angle 157 (149-173) vs. 159 (149-170); p = 0.01). CONCLUSION: Children with RS treated with the TPP showed normal long-term functional orthodontic outcomes, thanks to the functional adaption of the stomatognathic system. However, soft tissue growth did not completely match skeletal growth, resulting in a more convex facial profile.

7.
BMC Oral Health ; 21(1): 400, 2021 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-34399746

RESUMO

BACKGROUND: Lyme disease is the most frequent tick-borne infectious disease in Europe. It often presents with a wide variety of symptoms. For this reason, affection of the temporomandibular joint (TMJ) caused by Lyme disease (LD) can be misdiagnosed as a common temporomandibular disorder (TMD). CASE PRESENTATION: The purpose of this case report of a 25-year-old woman presenting to the Departments of Orthodontics and Oral and Maxillofacial Surgery with extensive symptoms of temporomandibular disorder is to illustrate the delayed diagnosis of Lyme disease which was only made after extensive therapy of the temporomandibular joint. The specialist literature only reports a few cases of patients suffering from Lyme disease with TMJ manifestations. CONCLUSION: This case report and the relevant literature review aim to emphasize the importance of accurate request of medical history and differential diagnosis of acute TMJ arthritis and arthralgia. Early interdisciplinary diagnosis of Lyme disease and early antibiotic therapy are essential to avoid misdiagnosis and unnecessary, sometimes invasive, therapies.


Assuntos
Artrite , Doença de Lyme , Transtornos da Articulação Temporomandibular , Adulto , Artralgia , Feminino , Humanos , Doença de Lyme/complicações , Doença de Lyme/diagnóstico , Doença de Lyme/tratamento farmacológico , Articulação Temporomandibular , Transtornos da Articulação Temporomandibular/diagnóstico , Transtornos da Articulação Temporomandibular/etiologia
8.
J Clin Med ; 10(12)2021 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-34208695

RESUMO

Three dimensional (3D) printing allows additive manufacturing of patient specific scaffolds with varying pore size and geometry. Such porous scaffolds, made of 3D-printable bone-like calcium phosphate cement (CPC), are suitable for bone augmentation due to their benefit for osteogenesis. Their pores allow blood-, bone- and stem cells to migrate, colonize and finally integrate into the adjacent tissue. Furthermore, the pore size affects the scaffold's stability. Since scaffolds in maxillofacial surgery have to withstand high forces within the jaw, adequate mechanical properties are of high clinical importance. Although many studies have investigated CPC for bone augmentation, the ideal porosity for specific indications has not been defined yet. We investigated 3D printed CPC cubes with increasing pore sizes and different printing orientations regarding cell migration and mechanical properties in comparison to commercially available bone substitutes. Furthermore, by investigating clinical cases, the scaffolds' designs were adapted to resemble the in vivo conditions as accurately as possible. Our findings suggest that the pore size of CPC scaffolds for bone augmentation in maxillofacial surgery necessarily needs to be adapted to the surgical site. Scaffolds for sites that are not exposed to high forces, such as the sinus floor, should be printed with a pore size of 750 µm to benefit from enhanced cell infiltration. In contrast, for areas exposed to high pressures, such as the lateral mandible, scaffolds should be manufactured with a pore size of 490 µm to guarantee adequate cell migration and in order to withstand the high forces during the chewing process.

9.
Ann Anat ; 236: 151716, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33675946

RESUMO

BACKGROUND: Dental implantology has become an established option for treating tooth loss over the recent decades. Before inserting an implant in a clinical situation, theoretical and practical training is recommended. Different methods are available to give assistance in determining the correctly planned implant position. In this study, two different guiding methods were assessed considering their accuracy for implant insertion in a group of dentists. METHODS: After three-dimensional planning of the implant positions, two surgical templates were manufactured as follows: in region 34 a stereolithographic template was used to perform a full-guided implant insertion, in region 44 a CAD/CAM milled template was used to determine the implant position and subsequently, perform a free-hand insertion. In total, 86 implants were placed in mandibular models by 43 dentists participating in a postgraduate curriculum. The differences between planned and achieved implant positions were measured and statistically analyzed. RESULTS: The implants inserted fully-guided showed a lower deviation of the three-dimensional angulation (2.266 ± 1.443 degrees vs. 7.954 ± 4.372 degrees) and the cumulated mismatch of the implant position (0.547 ± 0.237 mm vs. 1.160 ± 0.427 mm) compared to the free-handed mode. For the angulation and the mismatch at the implant base the differences were statistically significant (p < 0.001). CONCLUSIONS: Within the limits of the study it can be summarized that the full-guided implant insertion leads to a higher transfer accuracy compared to the free-hand method in a cohort of dentist inexperienced in dental implantology. However, the clinical effect has to be discussed as the study was performed using artificial mandibles and ideal conditions.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Currículo , Implantação Dentária Endóssea , Odontólogos , Humanos , Imageamento Tridimensional , Mandíbula/cirurgia , Planejamento de Assistência ao Paciente
10.
Int J Implant Dent ; 5(1): 23, 2019 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-31240421

RESUMO

BACKGROUND: As a growing field in dentistry, the practical education during the undergraduate curriculum in implant dentistry should be extended. Not only the theoretical background but also practical skills are crucial to place implants in patients. In order to determine the exact implant position, several positioning aids are available. In the present laboratory study, the accuracy of implant insertion using two different guiding modes in a group of inexperienced participants was assessed. METHODS: After three-dimensional planning using the data of a cone beam computed tomography of artificial mandibles, surgical templates were manufactured by thermoforming. In region 35, a sleeve for the pilot drill was used, whereas in region 45, a sleeve allowing a full-guided implant insertion was inserted. Subsequently, a total of 104 implants were placed by 52 undergraduates. Radiographical assessment of the three-dimensional accuracy was performed. Furthermore, the time required to insert the implants was recorded. Statistical analysis followed. DISCUSSION: When comparing the three-dimensional accuracy of the virtually planned to the actual inserted implant, a statistically significantly higher accuracy in three-dimensional angulation was achieved for the full-guided (3.388 ± 1.647°) compared to the pilot-drill guided mode (5.792 ± 3.290°). Furthermore, the time required to insert the implant was shorter for the full-guided template (6.23 ± 1.78 min) vs. for the pilot-drill guided (8.84 ± 2.39 min). Both differences reached a statistical significance (p < 0.001). CONCLUSION: Within the limit of this laboratory study, the results suggest that inexperienced surgeons benefit from a full-guided implant insertion. However, the clinical effects have to be discussed as the mismatch was varying in the decimillimeter range.

11.
Head Face Med ; 15(1): 5, 2019 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-30736811

RESUMO

BACKGROUND: The Gorlin-Goltz syndrome is an autosomal dominant disorder characterized by keratocystic odontogenic tumors in the jaws, multiple basal cell carcinomas and skeletal abnormities. Frequently, the manifestation of the syndrome occurs in the adolescent years. CASE PRESENTATION: An 11-year-old boy was referred to our clinic due to the persistence of the lower deciduous molars. The further diagnosis revealed bilateral keratocystic odontogenic tumors in the region of teeth 33 and 45 representing a symptom of a Gorlin-Goltz syndrome. This case of the oral rehabilitation of an adolescent with bilateral keratocystic odontogenic tumors shows the approach of a multidisciplinary treatment concept including the following elements: Enucleation and bone defect augmentation using a prefabricated bone graft; distraction osteogenesis to extend the graft-block vertically after cessation of growth; accompanying orthodontic treatment, guided implant placement and prosthetic rehabilitation. Six months after implant insertion, a new keratocystic odontogenic tumor in the basal part of the left sinus maxillaris had to be removed combined with the closure of the oroantral fistula. During the follow-up period of 18 months in semi-annual intervals, the patient showed no sign of pathology. CONCLUSION: In the presented case could be shown that distraction osteogenesis of prefabricated bone blocks is possible. With a multidisciplinary approach in a long-term treatment a sufficient oral rehabilitation of the patient suffering from extended keratocystic odontogenic tumors was possible.


Assuntos
Síndrome do Nevo Basocelular , Tumores Odontogênicos , Osteogênese por Distração , Adolescente , Síndrome do Nevo Basocelular/cirurgia , Humanos , Masculino , Maxila/cirurgia , Tumores Odontogênicos/cirurgia
12.
Dent J (Basel) ; 6(3)2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30200450

RESUMO

Implant dentistry is a growing field in the education of undergraduate dental students. The present laboratory study evaluates factors which may potentially influence the accuracy of free-hand implant insertion and the use of an orientation template. After three-dimensional planning using coDiagnostiXTM, orientation templates, including sleeves for the pilot-drill in regions 41 and 45, were manufactured by thermoforming. Sixty-one fifth year dental students inserted one implant using the orientation template and another implant free-hand in an artificial mandible. Information regarding age, sex, handedness, education, and the time required for implant insertion were recorded. Subsequently, the mandibles were scanned using cone-beam-computed tomography and the accuracy of the implant position was assessed, while statistical analysis followed. The free-hand implant insertion resulted in a distal deviation of -1.34 ± 5.15° and a mesial mismatch of 0.06 ± 0.79 mm at the artificial bone level compared to the sleeves. When using the orientation templates, the deviation decreased to -0.67 ± 3.48° and a distal mismatch of -0.22 ± 0.62 mm was achieved. The difference was statistically significant for the mismatch (p < 0.049). Regarding the limitations of our study, it could be said that the accuracy level achieved by dental undergraduates using implant placement with orientation templates is comparable to that in other studies.

13.
Front Physiol ; 8: 426, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28676766

RESUMO

Osteoporosis is a systemic bone disease with an increasing prevalence in the elderly population. There is conflicting opinion about whether osteoporosis affects the alveolar bone of the jaws and whether it poses a risk to the osseointegration of dental implants. The aim of the present study was to evaluate the effects of systemic glucocorticoid administration on the jaw bone density of minipigs. Thirty-seven adult female minipigs were randomly divided into two groups. Quantitative computed tomography (QCT) was used to assess bone mineral density BMD of the lumbar spine as well as the mandible and maxilla, and blood was drawn. One group of minipigs initially received 1.0 mg prednisolone per kg body weight daily for 2 months. The dose was tapered to 0.5 mg per kg body weight per day thereafter. The animals in the other group served as controls and received placebo. QCT and blood analysis were repeated after 6 and 9 months. BMD was compared between the two groups by measuring Hounsfield units, and serum levels of several bone metabolic markers were also assessed. A decrease in BMD was observed in the jaws from baseline to 9 months. This was more pronounced in the prednisolone group. Statistically significant differences were reached for the mandible (p < 0.001) and the maxilla (p < 0.001). The administration of glucocorticoids reduced the BMD in the jaws of minipigs. The described model shows promise in the evaluation of osseointegration of dental implants in bone that is compromised by osteoporosis.

14.
PLoS One ; 12(6): e0179249, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28666026

RESUMO

One consequence of demographic change is the increasing demand for biocompatible materials for use in implants and prostheses. This is accompanied by a growing number of experimental animals because the interactions between new biomaterials and its host tissue have to be investigated. To evaluate novel materials and engineered tissues the use of non-destructive imaging modalities have been identified as a strategic priority. This provides the opportunity for studying interactions repeatedly with individual animals, along with the advantages of reduced biological variability and decreased number of laboratory animals. However, histological techniques are still the golden standard in preclinical biomaterial research. The present article demonstrates a detailed method comparison between histology and magnetic resonance imaging. This includes the presentation of their image qualities as well as the detailed statistical analysis for assessing agreement between quantitative measures. Exemplarily, the bony ingrowth of tissue engineered bone substitutes for treatment of a cleft-like maxillary bone defect has been evaluated. By using a graphical concordance analysis the mean difference between MRI results and histomorphometrical measures has been examined. The analysis revealed a slightly but significant bias in the case of the bone volume [Formula: see text] and a clearly significant deviation for the remaining defect width [Formula: see text] But the study although showed a considerable effect of the analyzed section position to the quantitative result. It could be proven, that the bias of the data sets was less originated due to the imaging modalities, but mainly on the evaluation of different slice positions. The article demonstrated that method comparisons not always need the use of an independent animal study, additionally.


Assuntos
Imageamento por Ressonância Magnética/métodos , Animais , Materiais Biocompatíveis , Substitutos Ósseos , Bovinos , Imageamento por Ressonância Magnética/normas , Masculino , Ratos , Ratos Endogâmicos Lew , Engenharia Tecidual
15.
Clin Oral Investig ; 21(8): 2521-2534, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28101680

RESUMO

OBJECTIVES: The clinical standard for alveolar cleft osteoplasty is augmentation with autologous bone being available in limited amounts and might be associated with donor site morbidity. The aim of the present study was the creation of tissue-engineered bone grafts and their in vivo evaluation regarding their potential to promote osteogenesis in an alveolar cleft model. MATERIALS AND METHODS: Artificial bone defects with a diameter of 3.3 mm were created surgically in the palate of 84 adult Lewis rats. Four experimental groups (n = 21) were examined: bovine hydroxyl apatite/collagen (bHA) without cells, bHA with undifferentiated mesenchymal stromal cells (MSC), bHA with osteogenically differentiated MSC. In a control group, the defect remained empty. After 6, 9 and 12 weeks, the remaining defect volume was assessed by cone beam computed tomography. Histologically, the remaining defect width and percentage of bone formation was quantified. RESULTS: After 12 weeks, the remaining defect width was 60.1% for bHA, 74.7% for bHA with undifferentiated MSC and 81.8% for bHA with osteogenically differentiated MSC. For the control group, the remaining defect width measured 46.2% which was a statistically significant difference (p < 0.001). CONCLUSIONS: The study design was suitable to evaluate tissue-engineered bone grafts prior to a clinical application. In this experimental set-up with the described maxillary defect, no promoting influence on bone formation of bone grafts containing bHA could be confirmed. CLINICAL RELEVANCE: The creation of a sufficient tissue-engineered bone graft for alveolar cleft osteoplasty could preserve patients from donor site morbidity.


Assuntos
Enxerto de Osso Alveolar/métodos , Minerais/farmacologia , Osteogênese/fisiologia , Engenharia Tecidual/métodos , Animais , Diferenciação Celular , Células Cultivadas , Tomografia Computadorizada de Feixe Cônico , Fêmur/cirurgia , Masculino , Microscopia Eletrônica de Varredura , Microscopia de Fluorescência , Modelos Animais , Ratos , Ratos Endogâmicos Lew , Retalhos Cirúrgicos
16.
Head Face Med ; 12: 17, 2016 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-27066830

RESUMO

BACKGROUND: Ablative tumor surgery often results in continuity defects of the mandible. When an immediate reconstruction using autologous bone grafts is not possible the bridging of the defects with a variety of bridging plates might be achieved. However, those bridging plates have the risk of plate fractures or exposure. Customized titanium implants manufactured using CAD/CAM and the LaserCUSING® technique might be an alternative. METHODS: In the present study, computed tomographies (CT) of porcine cadaver mandibles were generated and transferred into DICOM data. Following, different continuity defects were surgically created in the mandibles. Based on the DICOM data customized titanium implants were manufactured using CAD/CAM procedures and the LaserCUSING® technique. The implants were fixed to the remaining stumps with screws. Subsequently, the accuracy of the reconstructed mandibles was tested using plaster casts. RESULTS: The workflow from the CT to the application of the customized implants was proved to be practicable. Furthermore, a stable fixation of the customized implant to the remaining stumps could be achieved. The control of the accuracy showed no frictions or obstacles. CONCLUSION: The customized titanium implant seems to be a promising approach to bridge continuity defects of the mandible whenever an immediate reconstruction with autologous bone is not possible.


Assuntos
Desenho Assistido por Computador , Implantes Dentários , Neoplasias Mandibulares/cirurgia , Reconstrução Mandibular/métodos , Animais , Placas Ósseas , Cadáver , Planejamento de Prótese Dentária , Estudos de Viabilidade , Imageamento Tridimensional , Modelos Dentários , Suínos , Tomografia Computadorizada por Raios X
17.
Support Care Cancer ; 23(10): 3089-93, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25763755

RESUMO

PURPOSE: At the moment, there is an inadequate margin fit of commercially available stoma buttons. The aim of the present study was to develop a customized short tracheal cannula based on digital data. Furthermore, the applied material has to be evaluated considering germ colonization and appropriate cleaning procedures. METHODS: Computed tomographies of 53 patients who underwent laryngectomy were surveyed. Based on the digital data, a customized short tracheal cannula was created and manufactured from silicone. The new cannula was incorporated in ten patients and worn for 4 weeks. A clinical examination of an otolaryngologist and subjective assessment of the patients were carried out. Furthermore, microbiological test considering germ colonization was performed. RESULTS: The customized short tracheal cannula could be incorporated in all patients. The clinical results showed no irritation or mucosal lesions. The subjective individual evaluation by the patients was promising. The proposals for improvement could be considered. The microbiological examination revealed a higher contamination of the silicone compared to the silver cannulas. Both chemical and mechanical decontamination showed sufficient results. CONCLUSION: A workflow for development and manufacturing of a customized short tracheal cannula from digital data could be established. The cannula is compatible to standard equipment and routine cleaning procedures. Clinical studies are required to evaluate the potential benefit for patients.


Assuntos
Catéteres , Traqueostomia/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Traqueia/patologia
18.
Biomed Res Int ; 2014: 934848, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25162036

RESUMO

Wound healing of soft tissue and bone defects is a complex process in which cellular differentiation and adaption are regulated by internal and external factors, among them are many different proteins. In contrast to insights into the significance of various single proteins based on model systems, the knowledge about the processes at the actual site of wound healing is still limited. This is caused by a general lack of methods that allow sampling of extracellular factors, metabolites, and proteins in situ. Sampling of wound fluids in combination with proteomics and metabolomics is one of the promising approaches to gain comprehensive and time resolved data on effector molecules. Here, we describe an approach to sample metabolites by microdialysis and to extract proteins simultaneously by adsorption. With this approach it is possible (i) to collect, enrich, and purify proteins for a comprehensive proteome analysis; (ii) to detect more than 600 proteins in different defects including more than 100 secreted proteins, of which many proteins have previously been demonstrated to have diagnostic or predictive power for the wound healing state; and (iii) to combine continuous sampling of cytokines and metabolites and discontinuous sampling of larger proteins to gain complementary information of the same defect.


Assuntos
Metabolômica , Biossíntese de Proteínas , Proteômica , Cicatrização/genética , Animais , Regeneração Óssea/genética , Catéteres , Regulação da Expressão Gênica , Humanos , Microdiálise , Biossíntese de Proteínas/genética , Ratos
19.
J Mater Sci Mater Med ; 25(1): 247-58, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24113890

RESUMO

Dental implants are an established therapy for oral rehabilitation. High success rates are achieved in healthy bone, however, these rates decrease in compromised host bone. Coating of dental implants with components of the extracellular matrix is a promising approach to enhance osseointegration in compromised peri-implant bone. Dental titanium implants were coated with an artificial extracellular matrix (aECM) consisting of collagen type I and either one of two regioselectively low sulfated hyaluronan (sHA) derivatives (coll/sHA1Δ6s and coll/sHA1) and compared to commercial pure titanium implants (control). After extraction of the premolar teeth, 36 implants were inserted into the maxilla of 6 miniature pigs (6 implants per maxilla). The healing periods were 4 and 8 weeks, respectively. After animal sacrifice, the samples were evaluated histomorphologically and histomorphometrically. All surface states led to a sufficient implant osseointegration after 4 and 8 weeks. Inflammatory or foreign body reactions could not be observed. After 4 weeks of healing, implants coated with coll/sHA1Δ6s showed the highest bone implant contact (BIC; coll/sHA1Δ6s: 45.4%; coll/sHA1: 42.2%; control: 42.3%). After 8 weeks, a decrease of BIC could be observed for coll/sHA1Δ6s and controls (coll/sHA1Δ6s: 37.3%; control: 31.7 %). For implants coated with coll/sHA1, the bone implant contact increased (coll/sHA1: 50.8%). Statistically significant differences could not be observed. Within the limits of the current study, aECM coatings containing low sHA increase peri-implant bone formation around dental implants in maxillary bone compared to controls in the early healing period.


Assuntos
Materiais Revestidos Biocompatíveis/química , Colágeno/química , Implantes Dentários , Ácido Hialurônico/análogos & derivados , Osseointegração , Animais , Feminino , Humanos , Ácido Hialurônico/química , Teste de Materiais , Maxila/anatomia & histologia , Maxila/cirurgia , Modelos Animais , Suínos , Porco Miniatura , Titânio/química
20.
J Craniomaxillofac Surg ; 42(6): 790-5, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24342731

RESUMO

OBJECTIVES: The reconstruction of mandibular continuity defects by bridging plates often leads to complications. Customized mandibular implants might be an alternative option. In the present study, the stability at the bone-implant-interface of customized two-piece implants was compared to one-piece implants. METHODS: Thirty pig mandibles were randomly divided into three groups. One group (A) was left untreated and served as reference. In groups B and C, a continuity defect was created in the left mandibular side. The defects were reconstructed by customized pure titanium implants, manufactured using the LaserCUSING(®) technology. Group B received a one-piece implant; in group C a two-piece implant was inserted to reconstruct the continuity defect. The bonding strength was examined statically and dynamically under standardized conditions. Digital Image Correlation was used for distortion measurement. Different dynamic measurements were performed for orientation purposes. RESULTS: The highest bonding strength was measured for the reference group. The two-piece implant showed an increased bonding strength when compared to the one-piece design. In all pig mandibles treated with individual implants a fracture occurred on the non-operated side. This indicates a high primary stability of the bone-implant-interface. CONCLUSION: The two-piece individual mandibular implant manufactured by LaserCUSING(®) technology should be further analyzed in future studies.


Assuntos
Placas Ósseas , Reconstrução Mandibular/instrumentação , Desenho de Prótese , Animais , Materiais Biocompatíveis/química , Desenho Assistido por Computador , Análise do Estresse Dentário/instrumentação , Imageamento Tridimensional/métodos , Fraturas Mandibulares/fisiopatologia , Osseointegração/fisiologia , Distribuição Aleatória , Estresse Mecânico , Suínos , Titânio/química , Tomografia Computadorizada por Raios X/métodos , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...