Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 63(10): 2694-2703, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38568554

RESUMO

Accurate assessment of corneal curvatures using frequency domain optical coherence tomography (OCT) with galvanometer scanners remains challenging due to the well-known scan field distortion. This paper presents an algorithm and software for correcting the distortion using only two simple measurements in which a readily available standard sphere is positioned in different depths in front of the OCT scanner. This offers a highly accessible and easily reproducible method for the field distortion correction (FDC). The correction was validated by measuring different spherical phantoms and conducting corneal curvature measurements of ex vivo porcine corneas using a commercial spectral-domain OCT system and a clinically approved swept-source OCT as a reference instrument. Thus, the error in radius measurements of spherical phantoms was reduced by >90% and astigmatism by >80% using FDC. In explanted porcine eyes, the error in astigmatism measurements with the Telesto was reduced by 75% for power and 70% for angle. The best fitting sphere radius was determined up to a deviation of 0.4% from the Anterion. This paper describes a correction algorithm for OCT immanent distortion that is applicable to any scanning OCT setup and enables precise corneal curvature measurements. The MATLAB software for the FDC is publicly available on GitHub.


Assuntos
Astigmatismo , Tomografia de Coerência Óptica , Animais , Suínos , Algoritmos , Software , Córnea/diagnóstico por imagem
2.
Opt Express ; 32(4): 5809-5825, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38439298

RESUMO

Circumferential scanning in endoscopic imaging is crucial across various disciplines, and optical coherence tomography (OCT) is often the preferred choice due to its high-speed, high-resolution, and micron-scale imaging capabilities. Moreover, real-time and high-speed 3D endoscopy is a pivotal technology for medical screening and precise surgical guidance, among other applications. However, challenges such as image jitter and non-uniform rotational distortion (NURD) are persistent obstacles that hinder real-time visualization during high-speed OCT procedures. To address this issue, we developed an innovative, low-cost endoscope that employs a brushless DC motor for scanning, and a sensorless technique for triggering and synchronizing OCT imaging with the scanning motor. This sensorless approach uses the motor's electrical feedback (back electromotive force, BEMF) as a virtual Hall sensor to initiate OCT image acquisition and synchronize it with a Fourier Domain Mode-Locked (FDML)-based Megahertz OCT system. Notably, the implementation of BEMF-triggered OCT has led to a substantial reduction in image jitter and NURD (<4 mrad), thereby opening up a new window for real-time visualization capabilities. This approach suggests potential benefits across various applications, aiming to provide a more accurate, deployable, and cost-effective solution. Subsequent studies can explore the adaptability of this system to specific clinical scenarios and its performance under practical endoscopic conditions.

3.
Am J Physiol Lung Cell Mol Physiol ; 323(4): L423-L430, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35997279

RESUMO

Asthma is one of the most common chronic diseases. Mucus overproduction is consistently linked to asthma morbidity and mortality. Despite the knowledge of the importance of mucus, little data exist on how mucus is transported in asthma and the immediate effects of therapeutic intervention. We therefore used microscopic optical coherence tomography (mOCT) to study spontaneous and induced mucus transport in an interleukin-13 (IL-13)-induced asthma mouse model and examined the effects of isotonic (0.9% NaCl) and hypertonic saline (7% NaCl), which are used to induce mucus transport in cystic fibrosis. Without intervention, no bulk mucus transport was observed by mOCT and no intraluminal mucus was detectable in the intrapulmonary airways by histology. Administration of ATP-γ-S induced mucus secretion into the airway lumen, but it did not result in bulk mucus transport in the trachea. Intraluminal-secreted immobile mucus could be mobilized by administration of isotonic or hypertonic saline but hypertonic saline mobilized mucus more reliably than isotonic saline. Irrespective of saline concentration, the mucus was transported in mucus chunks. In contrast to isotonic saline solution, hypertonic saline solution alone was able to induce mucus secretion. In conclusion, mOCT is suitable to examine the effects of mucus-mobilizing therapies in vivo. Although hypertonic saline was more efficient in inducing mucus transport, it induced mucus secretion, which might explain its limited benefit in patients with asthma.


Assuntos
Asma , Interleucina-13 , Trifosfato de Adenosina , Animais , Asma/diagnóstico por imagem , Asma/tratamento farmacológico , Microscopia Intravital , Camundongos , Muco , Solução Salina , Solução Salina Hipertônica/farmacologia , Solução Salina Hipertônica/uso terapêutico , Cloreto de Sódio , Tomografia de Coerência Óptica
4.
Biomed Opt Express ; 13(6): 3211-3223, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35781952

RESUMO

In the imaging of airway tissue, optical coherence tomography (OCT) provides cross-sectional images of tissue structures, shows cilia movement and mucus secretion, but does not provide sufficient contrast to differentiate individual cells. By using fast sequences of microscopic resolution OCT (mOCT) images, OCT can use small signal fluctuations to overcome lack in contrast and speckle noise. In this way, OCT visualizes airway morphology on a cellular level and allows the tracking of the dynamic behavior of immune cells, as well as mucus transport and secretion. Here, we demonstrate that mOCT, by using temporal tissue fluctuation as contrast (dynamic mOCT), provides the possibility to study physiological and pathological tissue processes in vivo.

5.
Transl Vis Sci Technol ; 11(5): 28, 2022 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-35622381

RESUMO

Purpose: Microscopic optical coherence tomography (mOCT) has an imaging resolution of 1 µm in all voxel dimensions, but individual epithelial cells are difficult to resolve due to lack of scattering contrast. Adding dynamic contrast processing to mOCT (dmOCT) results in color images that enable visualization of individual cells and possibly give information on cellular function via the calculation of a motility coefficient. We propose this technique as a novel method of evaluating the ocular surface after exposure to a toxic chemical, benzalkonium chloride (BAK). Methods: Ex vivo cross-section images were acquired with a custom-built, frequency-domain mOCT system. Eyes were explanted from healthy adult C57BL/6 mice and imaged every 30 minutes with five sets of dmOCT scans at each imaging time. Total epithelium and stroma thicknesses were measured from a single mOCT B-scan, and measures of color changes (hue) and the motility coefficient were acquired from dmOCT scans. Results: After 30-minute exposures to 0.005% BAK, local motility decreased and total epithelium thickness increased compared to controls. For basal epithelium cells, local motility decreased after 60-minute exposures, and the hue shifted red after 90-minute exposures. Stroma thickness did not significantly swell until 150-minute exposures to BAK. Conclusions: dmOCT allows us to view the behavior of the cornea epithelium under toxic stress due to BAK, revealing parallel swelling of the extracellular matrix and changes in local subcellular motion. Translational Relevance: The evaluation of the cornea epithelium using dmOCT is helpful to our understanding of the toxic effects of BAK.


Assuntos
Epitélio Corneano , Animais , Compostos de Benzalcônio , Epitélio Corneano/diagnóstico por imagem , Camundongos , Camundongos Endogâmicos C57BL , Tomografia de Coerência Óptica/métodos
6.
J Vasc Interv Radiol ; 33(4): 384-391.e7, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34958860

RESUMO

PURPOSE: To evaluate the feasibility and accuracy of a radiation-free implantation of a thoracic aortic stent graft employing fiberoptic and electromagnetic tracking in an anthropomorphic phantom. MATERIALS AND METHODS: An anthropomorphic phantom was manufactured based on computed tomography (CT) angiography data from a patient. An aortic stent graft application system was equipped with a fiber Bragg gratings and 3 electromagnetic sensors. The stent graft was navigated in the phantom by 3 interventionalists using the tracking data generated by both technologies. One implantation procedure was performed. The technical success of the procedure was evaluated using digital subtraction angiography and CT angiography (before and after the intervention). Tracking accuracy was determined at various anatomical landmarks based on separately acquired fluoroscopic images. The mean/maximum errors were measured for the stent graft application system and the tip/end of the stent graft. RESULTS: The procedure resulted in technical success with a mean error below 3 mm for the entire application system and <2 mm for the position of the tip of the stent graft. Navigation/implantation and handling of the device were rated sufficiently accurate and on par with comparable, routinely used stent graft application systems. CONCLUSIONS: The study demonstrates successful stent graft implantation during a thoracic endovascular aortic repair procedure employing advanced guidance techniques and avoiding fluoroscopic imaging. This is an essential step in facilitating the implantation of stent grafts and reducing the health risks associated with ionizing radiation during endovascular procedures.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Fenômenos Eletromagnéticos , Humanos , Imageamento Tridimensional , Stents , Resultado do Tratamento
7.
Biomed Opt Express ; 12(10): 6024-6039, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34745719

RESUMO

Volumetric imaging of dynamic processes with microscopic resolution holds a huge potential in biomedical research and clinical diagnosis. Using supercontinuum light sources and high numerical aperture (NA) objectives, optical coherence tomography (OCT) achieves microscopic resolution and is well suited for imaging cellular and subcellular structures of biological tissues. Currently, the imaging speed of microscopic OCT (mOCT) is limited by the line-scan rate of the spectrometer camera and ranges from 30 to 250 kHz. This is not fast enough for volumetric imaging of dynamic processes in vivo and limits endoscopic application. Using a novel CMOS camera, we demonstrate fast 3-dimensional OCT imaging with 600,000 A-scans/s at 1.8 µm axial and 1.1 µm lateral resolution. The improved speed is used for imaging of ciliary motion and particle transport in ex vivo mouse trachea. Furthermore, we demonstrate dynamic contrast OCT by evaluating the recorded volumes rather than en face planes or B-scans. High-speed volumetric mOCT will enable the correction of global tissue motion and is a prerequisite for applying dynamic contrast mOCT in vivo. With further increase in imaging speed and integration in flexible endoscopes, volumetric mOCT may be used to complement or partly replace biopsies.

8.
Int J Med Robot ; 17(6): e2327, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34480406

RESUMO

BACKGROUND: In endovascular aneuysm repair (EVAR) procedures, medical instruments are currently navigated with a two-dimensional imaging based guidance requiring X-rays and contrast agent. METHODS: Novel approaches for obtaining the three-dimensional instrument positions are introduced. Firstly, a method based on fibre optical shape sensing, one electromagnetic sensor and a preoperative computed tomography (CT) scan is described. Secondly, an approach based on image processing using one 2D fluoroscopic image and a preoperative CT scan is introduced. RESULTS: For the tracking based method, average errors from 1.81 to 3.13 mm and maximum errors from 3.21 to 5.46 mm were measured. For the image-based approach, average errors from 3.07 to 6.02 mm and maximum errors from 8.05 to 15.75 mm were measured. CONCLUSION: The tracking based method is promising for usage in EVAR procedures. For the image-based approach are applications in smaller vessels more suitable, since its errors increase with the vessel diameter.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Fluoroscopia , Humanos , Imageamento Tridimensional
9.
Ophthalmol Sci ; 1(4): 100085, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36246942

RESUMO

Purpose: To assess the efficacy of an instrument-integrated OCT (iiOCT)-based distance sensor during robotic vitreoretinal surgery using the Preceyes Surgical System (PSS; Preceyes B.V.). Design: Single-center interventional study. Participants: Patients requiring vitreoretinal surgery. Methods: Five patients were enrolled. Standard preoperative OCT images were obtained. After vitrectomy, a predefined set of actions was performed using the iiOCT-based sensor. Images then were processed to assess the signal-to-noise ratio (SNR) at various angles to the retina and at different distances between the instrument tip and the retinal surface. Preoperative and intraoperative OCT images were compared qualitatively and quantitatively. Main Outcomes Measures: The feasibility in performing surgical tasks using the iiOCT-based sensor during vitreoretinal surgery, the SNR when imaging the retina, differences among intraoperative and preoperative OCT images, and characteristics of intraoperative retinal movements detected with the iiOCT-based probe. Results: Surgeons were able to perform all the tasks but one. The PSS was able to maintain a fixed distance. The SNR of the iiOCT-based sensor signal was adequate to determine the distance to the retina and to control the PSS. Analysis of iiOCT-based sensor A-scans identified 3 clearly distinguishable retinal layers, including the inner retinal boundary and the interface at the retinal pigment epithelium-Bruch's membrane. Thickness values differed by less than 5% from that measured by preoperative OCT, indicating its accuracy. The Fourier analysis of iiOCT-based sensor recordings identified anteroposterior retinal movements attributed to heartbeat and respiration. Conclusions: This iiOCT-based sensor was tested successfully and promises reliable use during robot-assisted surgery. An iiOCT-based sensor is a promising step toward OCT-guided robotic retinal surgery.

10.
J Clin Med ; 9(10)2020 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33053724

RESUMO

Caries, the world's most common chronic disease, remains a major cause of invasive restorative dental treatment. To take advantage of the diagnostic potential of optical coherence tomography (OCT) in contemporary dental prevention and treatment, an intraorally applicable spectral-domain OCT probe has been developed based on an OCT hand-held scanner equipped with a rigid 90°-optics endoscope. The probe was verified in vitro. In vivo, all tooth surfaces could be imaged with the OCT probe, except the vestibular surfaces of third molars and the proximal surface sections of molars within a "blind spot" at a distance greater than 2.5 mm from the tooth surface. Proximal surfaces of 64 posterior teeth of four volunteers were assessed by intraoral OCT, visual-tactile inspection, bitewing radiography and fiber-optic transillumination. The agreement in detecting healthy and carious surfaces varied greatly between OCT and established methods (18.2-94.7%), whereby the established methods could always be supplemented by OCT. Direct and indirect composite and ceramic restorations with inherent imperfections and failures of the tooth-restoration bond were imaged and qualitatively evaluated. The intraoral OCT probe proved to be a powerful technological approach for the non-invasive imaging of healthy and carious hard tooth tissues and gingiva as well as tooth-colored restorations.

11.
Opt Lett ; 45(17): 4766-4769, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32870852

RESUMO

While optical coherence tomography (OCT) provides a resolution down to 1 µm, it has difficulties in visualizing cellular structures due to a lack of scattering contrast. By evaluating signal fluctuations, a significant contrast enhancement was demonstrated using time-domain full-field OCT (FF-OCT), which makes cellular and subcellular structures visible. The putative cause of the dynamic OCT signal is the site-dependent active motion of cellular structures in a sub-micrometer range, which provides histology-like contrast. Here we demonstrate dynamic contrast with a scanning frequency-domain OCT (FD-OCT), which we believe has crucial advantages. Given the inherent sectional imaging geometry, scanning FD-OCT provides depth-resolved images across tissue layers, a perspective known from histopathology, much faster and more efficiently than FF-OCT. Both shorter acquisition times and tomographic depth-sectioning reduce the sensitivity of dynamic contrast for bulk tissue motion artifacts and simplify their correction in post-processing. Dynamic contrast makes microscopic FD-OCT a promising tool for the histological analysis of unstained tissues.

12.
J Refract Surg ; 36(6): 406-413, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32521029

RESUMO

PURPOSE: To evaluate a new non-ablative and adjustable procedure for laser ablative refractive corneal surgery in hyperopia using the injection of a biocompatible liquid filler material into a stromal pocket. METHODS: A total of 120 stromal pockets were created using a clinical femtosecond laser system in 96 rabbit corneoscleral discs and 24 whole globes. Pockets were cut at a depth of 120 or 250 µm below the epithelial surface. Hyaluronic acid was injected manually into the pocket. To determine the refractive changes, three-dimensional optical coherence tomography images and a specifically developed picture recognition Matlab (The Mathworks) routine were used. RESULTS: After injection, a steepening of the anterior and flattening of the posterior corneal surface was observed, which led to hyperopic correction. The two main factors determining the amount of correction were the pocket depth and the injected volume. After the pocket was homogeneously filled, an initial refractive increase was observed, followed by a linear relation between the injected volume and the refraction increase. CONCLUSIONS: This possible clinical protocol for controlled refraction correction of hyperopia suggests a potential readjustable clinical application. [J Refract Surg. 2020;36(6):406-414.].


Assuntos
Substância Própria/efeitos dos fármacos , Ácido Hialurônico/administração & dosagem , Hiperopia/tratamento farmacológico , Viscossuplementos/administração & dosagem , Animais , Materiais Biocompatíveis/administração & dosagem , Substância Própria/diagnóstico por imagem , Topografia da Córnea , Hiperopia/diagnóstico por imagem , Hiperopia/fisiopatologia , Injeções Intraoculares , Coelhos , Refração Ocular/fisiologia , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia
13.
Int J Comput Assist Radiol Surg ; 15(6): 1033-1042, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32383105

RESUMO

PURPOSE: During endovascular aneurysm repair (EVAR) procedures, medical instruments are guided with two-dimensional (2D) fluoroscopy and conventional digital subtraction angiography. However, this requires X-ray exposure and contrast agent is used, and the depth information is missing. To overcome these drawbacks, a three-dimensional (3D) guidance approach based on tracking systems is introduced and evaluated. METHODS: A multicore fiber with fiber Bragg gratings for shape sensing and three electromagnetic (EM) sensors for locating the shape were integrated into a stentgraft system. A model for obtaining the located shape of the first 38 cm of the stentgraft system with two EM sensors is introduced and compared with a method based on three EM sensors. Both methods were evaluated with a vessel phantom containing a 3D-printed vessel made of silicone and agar-agar simulating the surrounding tissue. RESULTS: The evaluation of the guidance methods resulted in average errors from 1.35 to 2.43 mm and maximum errors from 3.04 to 6.30 mm using three EM sensors, and average errors from 1.57 to 2.64 mm and maximum errors from 2.79 to 6.27 mm using two EM sensors. Moreover, the videos made from the continuous measurements showed that a real-time guidance is possible with both approaches. CONCLUSION: The results showed that an accurate real-time guidance with two and three EM sensors is possible and that two EM sensors are already sufficient. Thus, the introduced 3D guidance method is promising to use it as navigation tool in EVAR procedures. Future work will focus on developing a method with less EM sensors and a detailed latency evaluation of the guidance method.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/instrumentação , Imageamento Tridimensional/métodos , Angiografia Digital , Procedimentos Endovasculares/métodos , Fluoroscopia , Humanos , Imagens de Fantasmas
14.
Cytometry A ; 97(5): 515-527, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32293804

RESUMO

Two-photon microscopy (2PM) has brought unique insight into the mechanisms underlying immune system dynamics and function since it enables monitoring of cellular motility and communication in complex systems within their genuine environment-the living organism. However, use of 2PM in clinical settings is limited. In contrast, optical coherence tomography (OCT), a noninvasive label-free diagnostic imaging method, which allows monitoring morphologic changes of large tissue regions in vivo, has found broad application in the clinic. Here we developed a combined multimodal technology to achieve near-instantaneous coregistered OCT, 2PM, and second harmonic generation (SHG) imaging over large volumes (up to 1,000 × 1,000 × 300 µm3 ) of tendons and other tissue compartments in mouse paws, as well as in mouse lymph nodes, spleens, and femurs. Using our multimodal imaging approach, we found differences in macrophage cell shape and motility behavior depending on whether they are located in tendons or in the surrounding tissue compartments of the mouse paw. The cellular shape of tissue-resident macrophages, indicative for their role in tissue, correlated with the supramolecular organization of collagen as revealed by SHG and OCT. Hence, the here-presented approach of coregistered OCT and 2PM has the potential to link specific cellular phenotypes and functions (as revealed by 2PM) to tissue morphology (as highlighted by OCT) and thus, to build a bridge between basic research knowledge and clinical observations. © 2020 The Authors. Cytometry Part A published by Wiley Periodicals, Inc. on behalf of International Society for Advancement of Cytometry.


Assuntos
Microscopia , Tomografia de Coerência Óptica , Animais , Movimento Celular , Colágeno , Camundongos , Fótons
15.
Am J Physiol Lung Cell Mol Physiol ; 318(3): L518-L524, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31994896

RESUMO

Airway mucus obstruction is a hallmark of chronic lung diseases such as cystic fibrosis, asthma, and COPD, and the development of more effective mucus-mobilizing therapies remains an important unmet need for patients with these muco-obstructive lung diseases. However, methods for sensitive visualization and quantitative assessment of immediate effects of therapeutic interventions on mucus clearance in vivo are lacking. In this study, we determined whether newly developed high-speed microscopic optical coherence tomography (mOCT) is sensitive to detect and compare in vivo effects of inhaled isotonic saline, hypertonic saline, and bicarbonate on mucus mobilization and clearance in Scnn1b-transgenic mice with muco-obstructive lung disease. In vivo mOCT imaging showed that inhaled isotonic saline-induced rapid mobilization of mucus that was mainly transported as chunks from the lower airways of Scnn1b-transgenic mice. Hypertonic saline mobilized a significantly greater amount of mucus that showed a more uniform distribution compared with isotonic saline. The addition of bicarbonate-to-isotonic saline had no effect on mucus mobilization, but also led to a more uniform mucus layer compared with treatment with isotonic saline alone. mOCT can detect differences in response to mucus-mobilizing interventions in vivo, and may thus support the development of more effective therapies for patients with muco-obstructive lung diseases.


Assuntos
Modelos Animais de Doenças , Canais Epiteliais de Sódio/fisiologia , Microscopia Intravital/métodos , Pneumopatias Obstrutivas/diagnóstico por imagem , Depuração Mucociliar , Muco/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Animais , Humanos , Pneumopatias Obstrutivas/patologia , Pneumopatias Obstrutivas/terapia , Camundongos , Camundongos Transgênicos , Muco/fisiologia
16.
Int J Comput Assist Radiol Surg ; 14(12): 2137-2145, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31493113

RESUMO

PURPOSE: Endovascular aortic repair procedures are currently conducted with 2D fluoroscopy imaging. Tracking systems based on fiber Bragg gratings are an emerging technology for the navigation of minimally invasive instruments which can reduce the X-ray exposure and the used contrast agent. Shape sensing of flexible structures is challenging and includes many calculations steps which are prone to different errors. To reduce this errors, we present an optimized shape sensing model. METHODS: We analyzed for every step of the shape sensing process, which errors can occur, how the error affects the shape and how it can be compensated or minimized. Experiments were done with one multicore fiber system with 38 cm sensing length, and the effects of different methods and parameters were analyzed. Furthermore, we compared 3D shape reconstructions with the segmented shape of the corresponding CT scans of the fiber to evaluate the accuracy of our optimized shape sensing model. Finally, we tested our model in a realistic endovascular scenario by using a 3D printed vessel system created from patient data. RESULTS: Depending on the complexity of the shape, we reached an average error of 0.35-1.15 mm and maximal error of 0.75-7.53 mm over the whole 38 cm sensing length. In the endovascular scenario, we obtained an average and maximal error of 1.13 mm and 2.11 mm, respectively. CONCLUSION: The accuracies of the 3D shape sensing model are promising, and we plan to combine the shape sensing based on fiber Bragg gratings with the position and orientation of an electromagnetic tracking to obtain the located catheter shape.


Assuntos
Procedimentos Endovasculares/instrumentação , Tecnologia de Fibra Óptica , Tomografia Computadorizada por Raios X , Procedimentos Endovasculares/métodos , Humanos , Modelos Teóricos
17.
J Biomed Opt ; 24(4): 1-11, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-31041858

RESUMO

Optical coherence tomography angiography (OCTA) provides in-vivo images of microvascular perfusion in high resolution. For its application to basic and clinical research, an automatic and robust quantification of the capillary architecture is mandatory. Only this makes it possible to reliably analyze large amounts of image data, to establish biomarkers, and to monitor disease developments. However, due to its optical properties, OCTA images of skin often suffer from a poor signal-to-noise ratio and contain imaging artifacts. Previous work on automatic vessel segmentation in OCTA mostly focuses on retinal and cerebral vasculature. Its applicability to skin and, furthermore, its robustness against imaging artifacts had not been systematically evaluated. We propose a segmentation method that improves the quality of vascular quantification in OCTA images even if corrupted by imaging artifacts. Both the combination of image processing methods and the choice of their parameters are systematically optimized to match the manual labeling of an expert for OCTA images of skin. The efficacy of this optimization-based vessel segmentation is further demonstrated on sample images as well as by a reduced error of derived quantitative vascular network characteristics.


Assuntos
Angiografia/métodos , Capilares/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Pele/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Algoritmos , Artefatos , Humanos , Pele/irrigação sanguínea
18.
Opt Lett ; 43(18): 4386-4389, 2018 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-30211870

RESUMO

We present a forward-viewing fiber scanning endoscope (FSE) for high-speed volumetric optical coherence tomography (OCT). The reduction in size of the probe was achieved by substituting the focusing optics by an all-fiber-based imaging system which consists of a combination of scanning single-mode fibers, a glass spacer, made from a step-index multi-mode fiber, and a gradient-index fiber. A lateral resolution of 11 µm was achieved at a working distance of 1.2 mm. The newly designed piezo-based FSE has an outer diameter of 1.6 mm and a rigid length of 13.5 mm. By moving the whole imaging optic in spirals for scanning the sample, the beam quality remains constant over the entire field of view with a diameter of 0.8 mm. The scanning frequency was adjusted to 1.22 kHz for use with a 3.28 MHz Fourier domain mode locked OCT system. Densely sampled volumes have been imaged at a rate of 6 volumes per second.

19.
Biomed Opt Express ; 9(2): 636-647, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29552400

RESUMO

Intravital microscopy (IVM) offers the opportunity to visualize static and dynamic changes of tissue on a cellular level. It is a valuable tool in research and may considerably improve clinical diagnosis. In contrast to confocal and non-linear microscopy, optical coherence tomography (OCT) with microscopic resolution (mOCT) provides intrinsically cross-sectional imaging. Changing focus position is not needed, which simplifies especially endoscopic imaging. For in-vivo imaging, here we are presenting endo-microscopic OCT (emOCT). A graded-index-lens (GRIN) based 2.75 mm outer diameter rigid endoscope is providing 1.5 - 2 µm nearly isotropic resolution over an extended field of depth. Spherical and chromatic aberrations are used to elongate the focus length. Simulation of the OCT image formation, suggests a better overall image quality in this range compared to a focused Gaussian beam. Total imaging depth at a reduced sensitivity and lateral resolution is more than 200 µm. Using a frame rate of 80 Hz cross-sectional images of concha nasalis were demonstrated in humans, which could resolve cilial motion, cellular structures of the epithelium, vessels and blood cells. Mucus transport velocity was successfully determined. The endoscope may be used for diagnosis and treatment control of different lung diseases like cystic fibrosis or primary ciliary dyskinesia, which manifest already at the nasal mucosa.

20.
Invest Ophthalmol Vis Sci ; 58(13): 5880-5886, 2017 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29149239

RESUMO

Purpose: Corneal neovascularization, in particular lymphangiogenesis, is a limiting factor in corneal transplant survival. Novel treatment approaches focus on (selective) inhibition and regression of lymphatic vessels. Imaging clinically invisible corneal lymphatic vessels is a prerequisite for these strategies. Using a murine model, this study investigates whether corneal lymphatic vessels can be imaged using microscopic optical coherence tomography (mOCT). Methods: Corneal neovascularization was induced by intrastromal placement of 11.0 nylon sutures in one eye of BALB/c mice. After 2 weeks, cross-sectional images and volumes of the corneas with a 0.5 mm lateral and axial field of view were acquired using a custom-built mOCT system enabling a resolution of 1 µm at a B-scan rate of 165/s. Three of the six animals received an additional intrastromal injection of India ink 24 hours before the measurement to stain the corneal lymphatic system in vivo. Immunohistochemistry using CD31 and LYVE-1 was used to validate the mOCT findings. Results: Using mOCT, lymphatic vessels were visible as dark vessel-like structures with the lumen lacking a hyperreflective wall and mostly lacking cells. However, individual, slowly moving particles, which most likely are immune cells, occasionally could be observed inside the lumen. In lymphatic vessels of ink-stained corneas, hyperreflection and shadowing underneath was observed. Ink-filled lymphatic vessels were colocalized in consecutive corneal flat mounts of the same specimen. Conclusions: Corneal lymphatic vessels can be imaged using mOCT. This novel approach opens new options for noninvasive clinical imaging of corneal lymphatic vessels for diagnostic and therapeutic indications.


Assuntos
Neovascularização da Córnea/diagnóstico por imagem , Modelos Animais de Doenças , Vasos Linfáticos/diagnóstico por imagem , Tomografia de Coerência Óptica , Animais , Neovascularização da Córnea/metabolismo , Feminino , Técnica Indireta de Fluorescência para Anticorpo , Glicoproteínas/metabolismo , Vasos Linfáticos/metabolismo , Proteínas de Membrana Transportadoras , Camundongos , Camundongos Endogâmicos BALB C , Microscopia Confocal , Molécula-1 de Adesão Celular Endotelial a Plaquetas/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...