Resultados 1 - 20 de 43
Filtrar
1.
Saudi Dent J ; 36(2): 291-295, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38419982

RESUMO

Objective: To assess the performance of human observers and convolutional neural networks (CNNs) in detecting periodontal lesions in cone beam computed tomography (CBCT), a total of 38 datasets were examined. Three human readers and a CNN-based solution were employed to evaluate the presence of periodontal pathologies in these datasets. Materials and Methods: Datasets were acquired with a Veraview X800 L P (JMorita Mfg. Corp., Kyoto, Japan). Three general dentists, previously calibrated by a general principal investigator, read the datasets in 3D MPR mode using Horos(LGPL license at Horosproject.org and sponsored by Nimble Co LLC d/b/a Purview in Annapolis, MD, USA) as a DICOM reader. All pathological changes including vertical bone loss, furcation involvement, and periradicular osteolysis were detected. Furthermore, the same datasets were analyzed automatically by Diagnocat (Diagnocat LLC, Prague, Czech Republic), a deep CNN. Finally, the performance of the dentists and the CNN were compared and evaluated. Results: The CNN's performance was significantly lower compared to the human readers in the search for different types of lesions. The human observers achieved good to very good interobserver agreement, except for the evaluation of the vertical lesions, which resulted in a moderate agreement. Conclusion: The CNN used in this study was found to be ineffective in identifying periodontal lesions and was not adequately trained to offer significant assistance in the automated evaluation of periodontal lesions in CBCT datasets.

2.
Int J Comput Dent ; 0(0): 0, 2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37341386

RESUMO

AIM: Aim of this study comprised the software-supported evaluation of measurement accuracy between cone-beam computed tomography (CBCT) and panoramic radiographs in the assessment of the periodontal bone level in patients with periodontitis and comparison with clinical periodontal parameters. MATERIAL AND METHODS: Twenty patients with severe periodontitis (stage III-IV) were evaluated clinically and radiographically (panoramic and CBCT). Diagnostic interpretation comprised three blinded investigators with different levels of experience. Specific software-basing measurement procedure evaluated radiological distances for the mesial, central, and distal bone levels on the oral and vestibular sides of the teeth investigated and furcation upper and lower boundary. Jaw localization, anatomical region-of-interest, the number of roots and experience of the observers were evaluated. All measurements were carried out twice by the same observers within a 6-week interval. RESULTS: Slightly higher measurement deviations (SD) in the range of 0.47 (0.40) mm were found for CBCT evaluation compared to panoramic imaging. Pearson correlation analysis showed statistically strong positive correlation for the mesial and distal aspects, moderate positive correlation was found for the investigated furcations between both radiographic modalities. Compared to the clinical reference, the mean total error of measurement (SD) was larger for panoramic imaging (0.66 (0.48) mm) than CBCT (0.27 (0.08) mm) for all three observers. CONCLUSIONS: Software-supported CBCT analysis delivers better diagnostic information about the bony periodontal conditions of the patient compared to two-dimensional radiographs. However, it remains unclear if these additional information lead to better periodontal outcomes.

3.
Dentomaxillofac Radiol ; 48(2): 20180009, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30182744

RESUMO

OBJECTIVE:: To compare effective dose differences when acquiring (1) dose reduction mode and (2) manual mode in a MORITA R100 CBCT. METHODS:: 24 exposure protocols with different technique factors were performed in both the dose reduction mode and the manual mode in a Veraviewepocs 3D R100 cone beam CT device. 48 TLD were placed in a RANDO head phantom at 24 different sites. Effective doses were calculated according to the formalism published in the 103rd ICRP report. RESULTS:: Effective doses for the dose reduction mode protocols ranged from 14 to 156 µSv [mean = 57 µSv, standard deviation (SD) = 37 µSv], whereas effective doses for the manual mode protocols ranged from 22 to 267 µSv (mean = 94 µSv, SD = 65 µSv). Thus, across all protocols, the dose reduction mode leads to a drop of the effective dose by 38 % (SD = 6 %). CONCLUSIONS:: The estimated effective doses are significantly lower if dose reduction protocols are acquired.


Assuntos
Tomografia Computadorizada de Feixe Cônico Espiral , Dosimetria Termoluminescente , Tomografia Computadorizada de Feixe Cônico , Imagens de Fantasmas , Doses de Radiação
4.
Dentomaxillofac Radiol ; 47(3): 20160410, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29319336

RESUMO

OBJECTIVES: The present study aims at investigating different radiation protection issues and dose values while acquiring intraoral images with a handheld X-ray device. METHODS: An Aribex NOMAD Pro 2™, a RANDO® male head phantom, a consistency testing body, a PTW NOMEX® Multimeter, and a PTW Farmer® Ionization Chamber Type 30,010 were used to investigate: (1) dose area products; (2) the expansion of the control area (CA); (3) the scattering pattern and (4) the potential risk for operators of the X-ray device. RESULTS: Dose area products at different exposure times were distributed linearly with a high correlation factor (>0.9). At 4000 simulated exposures, the greatest extent of the CA was 42 cm (mean = 16.7 cm, SD = 10.8 cm). The highest occurrence of scattering radiation resulted between the RANDO® phantom and the X-ray device. No scattered radiation was measured at the dorsal part of the phantom or on the operator site of a virtual vertical plane through the focal spot of the X-ray. CONCLUSIONS: Through this study, we could demonstrate that the application of an Aribex NOMAD Pro 2 device for intraoral imaging does not increase the risk for the operator if the device is controlled according to the manufacturer's specifications. Furthermore, we were able to show that the CA was significantly smaller than specified by European and other international radiation protection standards.


Assuntos
Saúde Ocupacional , Proteção Radiológica , Radiografia Dentária/instrumentação , Desenho de Equipamento , Imagens de Fantasmas , Doses de Radiação
5.
Drug Test Anal ; 10(6): 938-946, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29278456

RESUMO

Mass spectrometry (MS) allows for monitoring growth hormone (GH) isoform compositions at high specificity. It is demonstrated that this capability can be used to reliably detect alterations as elicited by (putative) doping with 22 kDa-GH. Sample treatment consists of enzymatic protein cleavage, followed by 2-step liquid chromatography clean-up, prior to analysis by MS. The protocol does not depend on antibodies for analyte extraction at any stage. Therefore, MS opens an opportunity for independent confirmation, if combined with the antibody-based isoform differential test presently used in practice. To check the fitness-for-purpose of this concept, GH-free serum was spiked with pure 22 kDa- and 20 kDa-GH covering a representative range of concentrations (0.5-9.4 µg/L), while the 22kDa fraction was within a range of  80%-85%, or at 100%, the latter simulating an administration of 22 kDa-GH. Mean deviation of 22 kDa-fractions found was within less than 3% for samples with total GH>= 1 µg/L . Beyond this, results by antibody-free isoform-differential MS, as described, were in line with those of the World Anti-Doping Agency-approved antibody-based test for 18 native sera and 3 positive controls. In this context, relating 22 kDa-GH to total-GH rather than 22 kDa+20 kDa was considered as an alternative strategy to earlier approaches. However, 20 kDa-GH as an additional measurand, next to 22 kDa- and total-GH, provides useful extra information, as it directly indicates the presence or absence of a non-22 kDa-GH form.


Assuntos
Hormônio do Crescimento/sangue , Isoformas de Proteínas/sangue , Detecção do Abuso de Substâncias/métodos , Cromatografia Líquida , Feminino , Humanos , Imunoensaio , Masculino , Espectrometria de Massas em Tandem
6.
Int J Prosthodont ; 30(2): 147-149, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28267823

RESUMO

PURPOSE: The aim of this study was to evaluate the feasibility and accuracy of using an intraoral scanner to digitize edentulous maxillectomy defects. MATERIALS AND METHODS: A total of 20 maxillectomy models with two defect types were digitized using cone beam computed tomography. Conventional and digital impressions were made using silicone impression material and a laboratory optical scanner as well as a chairside intraoral scanner. The 3D datasets were analyzed using 3D evaluation software. RESULTS: Two-way analysis of variance revealed no interaction between defect types and impression methods, and the accuracy of the impression methods was significantly different (P = .0374). CONCLUSION: Digitizing edentulous maxillectomy defect models using a chairside intraoral scanner appears to be feasible and accurate.


Assuntos
Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Técnica de Moldagem Odontológica , Arcada Edêntula/diagnóstico por imagem , Maxila/diagnóstico por imagem , Maxila/cirurgia , Obturadores Palatinos , Estudos de Viabilidade , Humanos , Imageamento Tridimensional , Modelos Dentários , Software
7.
Int J Comput Assist Radiol Surg ; 12(12): 2119-2128, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28083804

RESUMO

INTRODUCTION: The ATI SPG microstimulator is designed to be fixed on the posterior maxilla, with the integrated lead extending into the pterygopalatine fossa to electrically stimulate the sphenopalatine ganglion (SPG) as a treatment for cluster headache. Preoperative surgical planning to ensure the placement of the microstimulator in close proximity (within 5 mm) to the SPG is critical for treatment efficacy. The aim of this study was to improve the surgical procedure by navigating the initial dissection prior to implantation using a passive optical navigation system and to match the post-operative CBCT images with the preoperative treatment plan to verify the accuracy of the intraoperative placement of the microstimulator. METHODS: Custom methods and software were used that result in a 3D rotatable digitally reconstructed fluoroscopic image illustrating the patient-specific placement with the ATI SPG microstimulator. Those software tools were preoperatively integrated with the planning software of the navigation system to be used intraoperatively for navigated placement. Intraoperatively, the SPG microstimulator was implanted by completing the initial dissection with CT navigation, while the final position of the stimulator was verified by 3D CBCT. Those reconstructed images were then immediately matched with the preoperative CT scans with the digitally inserted SPG microstimulator. This method allowed for visual comparison of both CT scans and verified correct positioning of the SPG microstimulator. RESULTS: Twenty-four surgeries were performed using this new method of CT navigated assistance during SPG microstimulator implantation. Those results were compared to results of 21 patients previously implanted without the assistance of CT navigation. Using CT navigation during the initial dissection, an average distance reduction of 1.2 mm between the target point and electrode tip of the SPG microstimulator was achieved. Using the navigation software for navigated implantation and matching the preoperative planned scans with those performed post-operatively, the average distance was 2.17 mm with navigation, compared to 3.37 mm in the 28 surgeries without navigation. CONCLUSION: Results from this new procedure showed a significant reduction (p = 0.009) in the average distance from the SPG microstimulator to the desired target point. Therefore, a distinct improvement could be achieved in positioning of the SPG microstimulator through the use of intraoperative navigation during the initial dissection and by post-operative matching of pre- and post-operatively performed CBCT scans.


Assuntos
Cefaleia Histamínica/cirurgia , Terapia por Estimulação Elétrica/instrumentação , Eletrodos Implantados , Gânglios Parassimpáticos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Doença Crônica , Cefaleia Histamínica/diagnóstico , Feminino , Humanos , Período Intraoperatório , Masculino , Resultado do Tratamento
8.
Radiat Prot Dosimetry ; 175(1): 110-117, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27664428

RESUMO

The aim of the present work was to investigate absorbed and to calculate effective doses (EDs) in cone-beam computed tomography (CBCT). The study was conducted using examination protocols with and without lead apron shielding. A full-body male RANDO® phantom was loaded with 110 GR200A thermoluminescence dosemeter chips at 55 different sites and set up in two different CBCT systems (CS 9500®, ProMax® 3D). Two different protocols were performed: the phantom was set up (1) with and (2) without a lead apron. No statistically significant differences in organ and absorbed doses from regions outside the primary beam could be found when comparing results from exposures with and without lead apron shielding. Consequently, calculating the ED showed no significant differences between the examination protocols with and without lead apron shielding. For the ProMax® 3D with shielding, the ED was 149 µSv, and for the examination protocol without shielding 148 µSv (SD = 0.31 µSv). For the CS 9500®, the ED was 88 and 86 µSv (SD = 0.95 µSv), respectively, with and without lead apron shielding. The results revealed no statistically significant differences in the absorbed doses between examination with and without lead apron shielding, especially in organs outside the primary beam.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Doses de Radiação , Proteção Radiológica , Humanos , Masculino , Imagens de Fantasmas , Dosimetria Termoluminescente
9.
Dentomaxillofac Radiol ; 45(4): 20150436, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26959644

RESUMO

OBJECTIVES: Conventional panoramic radiography (cPR) underlines procedure-related limitations in the display of objects. CBCT is presumed to overcome these constraints. To virtualize a cPR view, reformatted panoramic images (rPIs) can be generated. This study evaluated the rPI with regard to its susceptibility to sterical object deposition in comparison with cPR. METHODS: A specially developed implant model with dental implants each of 4.0-mm diameter and 11.0-mm length was depositioned by shift, rotation and tilt of 5.00 mm (±0.01 mm) of horizontal shift and 5.0° (±0.167°), respectively, on a highly precise goniometer rotation table, and cPRs and rPIs were generated. Automated evaluation of the cPRs was carried out using a specially developed software. rPIs were processed and analyzed by a semi-automated image analysis. RESULTS: Object deposition lead to distortive effects in the rPI analogue to cPR, but they appear in display only. Objects illustrated in the rPI were dimensionally correct, but sterical relations are elusive. Results are obtained for the horizontal shift, declination and reclination, lateral tilt and rotation. CONCLUSIONS: Distortions within the rPI represent the illustration of the hyperbolic-shaped layer out of the three-dimensional data set. With this study, we demonstrated these procedure-related inherent but practically underestimated consequences. Effects of sterical object malpositioning must be compensated by the observer by adequate virtual adjustment of the processed layer. Accurate virtual adjustment leads to vertical dimensions. Sterical relations, e.g. angulation of two objects, are irretraceable unless precisely referenced.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Radiografia Panorâmica/métodos , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Implantes Dentários , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/estatística & dados numéricos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Panorâmica/estatística & dados numéricos , Reprodutibilidade dos Testes , Rotação , Interface Usuário-Computador
10.
Dentomaxillofac Radiol ; 45(1): 20150177, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26371075

RESUMO

OBJECTIVES: The purpose of this study was to design, build and test a multielement receive coil array and position system, which is optimized for three-dimensional (3D) high-resolution dental and maxillomandibular MRI with high patient comfort. METHODS: A 14 + 1 coil array and positioning system, allowing easy handling by the technologists, reproducible positioning of the patients and high patient comfort, was tested with three healthy volunteers using a 3.0-T MRI machine (Siemens Skyra; Siemens Medical Solutions, Erlangen, Germany). High-resolution 3D T1 weighted, water excitation T1 weighted and fat-saturated T2 weighted imaging sequences were scanned, and 3D image data were reformatted in different orientations and curvatures to aid diagnosis. RESULTS: The high number of receiving coils and the comfortable positioning of the coil array close to the patient's face provided a high signal-to-noise ratio and allowed high quality, high resolution, 3D image data to be acquired within reasonable scan times owing to the possibility of parallel image acquisition acceleration. Reformatting the isotropic 3D image data in different views is helpful for diagnosis, e.g. panoramic reconstruction. The visibility of soft tissues such as the mandibular canal, nutritive canals and periodontal ligaments was exquisite. CONCLUSIONS: The optimized MRI receive coil array and positioning system for dental and oral-maxillofacial imaging provides a valuable tool for detecting and diagnosing pathologies in dental and oral-maxillofacial structures while avoiding radiation dose. The high patient comfort, as achieved by our design, is very crucial, since image artefacts due to movement or failing to complete the examination jeopardize the diagnostic value of MRI examinations.


Assuntos
Aumento da Imagem/instrumentação , Imageamento Tridimensional/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Mandíbula/anatomia & histologia , Maxila/anatomia & histologia , Dente/anatomia & histologia , Artefatos , Desenho de Equipamento , Ósteon/anatomia & histologia , Humanos , Posicionamento do Paciente , Ligamento Periodontal/anatomia & histologia , Processamento de Sinais Assistido por Computador/instrumentação , Fatores de Tempo
11.
J Oral Sci ; 57(4): 389-92, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26666865

RESUMO

We describe a rare case of osteochondroma of the coronoid process of mandible accompanied by severe trismus in a 14-year-old Japanese boy. The patient had initially been diagnosed as having internal derangement of the temporomandibular joint (TMJ), and conservative treatment had failed to improve the symptoms. Despite extremely limited TMJ movement, panoramic radiography revealed no abnormality, but magnetic resonance imaging suggested internal derangement of the left TMJ. Five months later, the trismus worsened and computed tomography revealed a bone-like mass confluent with the coronoid process, which was finally diagnosed as osteochondroma. The patient then underwent intra-oral coronoidectomy.


Assuntos
Neoplasias Mandibulares/diagnóstico , Osteocondroma/diagnóstico , Adolescente , Humanos , Imageamento por Ressonância Magnética , Masculino , Neoplasias Mandibulares/complicações , Neoplasias Mandibulares/diagnóstico por imagem , Neoplasias Mandibulares/patologia , Osteocondroma/complicações , Osteocondroma/diagnóstico por imagem , Osteocondroma/patologia , Radiografia Panorâmica , Tomografia Computadorizada por Raios X , Trismo/complicações
12.
J Appl Clin Med Phys ; 16(4): 266­278, 2015 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-26219008

RESUMO

The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k = 2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low-dose limit. The sensitivity was 3.09 ± 0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was -8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD-comparable low-dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in vivo measurements (<1.7 mGy) the sensitivity is too low.


Assuntos
Antropometria , Anormalidades Maxilofaciais/radioterapia , Imagens de Fantasmas , Fótons , Semicondutores , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos , Cabeça/diagnóstico por imagem , Humanos , Doses de Radiação , Radiografia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
13.
J Craniomaxillofac Surg ; 43(7): 1088-93, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26165761

RESUMO

OBJECTIVES: More than 50% of all children suffer a traumatic dental injury (TDI) during childhood. In many cases, dentists apply root canal treatment (RCT), which is performed on an average of 7-10 days after replantation. Our aim was to evaluate whether RCT is necessary in many cases, and whether revitalization of affected teeth is possible and measurable by visualization using 3T magnetic resonance imaging (MRI). MATERIAL AND METHODS: Seven healthy children with TDI were treated by repositioning of the affected teeth and reduction of alveolar process fractures followed by splinting. Two weeks after initial treatment, splints were removed. After 6 weeks, all children received 3-Tesla (3T), three-dimensional, high-resolution MRI with a 20-channel standard head and neck coil. The mean age of the children (male/female = 5:2) was 10.8 years (range, 8-17 years). In addition, all children received conventional dental examination for tooth vitality and dental sensitivity to cold and tenderness on percussion. RESULTS: 3T MRI provided excellent images that allowed fine discrimination between dental pulp and adjacent tooth. Using four in-house optimized, non-contrast-enhanced sequences, including panoramic reconstruction, the assessment and analysis of the dental pulp was sufficiently feasible. We could demonstrate reperfusion and thus vitality of the affected teeth in 11 sites. In one child, MRI was able to detect nonreperfusion after TDI of the affected tooth. MRI results were confirmed by clinical examination in all cases. As a consequence of this expectant management and proof of reperfusion and tooth vitality by 3T MRI, only one child had to be treated by RCT. CONCLUSION: 3T MRI is a very promising tool for visualization and detection in the field of dental and oromaxillofacial diseases. By using new 3T MRI sequences in children with TDI, we could demonstrate that RCT are not necessary in every case, and thus could prevent unnecessary treatment of children in the future. Larger studies should follow to confirm the potential benefit in clinical practice.


Assuntos
Necrose da Polpa Dentária/diagnóstico por imagem , Polpa Dentária/fisiologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Traumatismos Dentários/complicações , Adolescente , Processo Alveolar/lesões , Anatomia Transversal/métodos , Criança , Polpa Dentária/irrigação sanguínea , Polpa Dentária/diagnóstico por imagem , Diagnóstico Precoce , Feminino , Seguimentos , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Fraturas Maxilares/terapia , Tratamento do Canal Radicular , Contenções , Avulsão Dentária/terapia , Traumatismos Dentários/terapia , Reimplante Dentário/métodos
14.
Swiss Dent J ; 125(3): 293-311, 2015.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-26168687

RESUMO

An adequate portrayal of the root canal anatomy by diagnostic imaging is a prerequisite for a successful diagnosis and therapy in endodontics. The introduction of dental cone beam computed tomography (CBCT) has considerably expanded the scope of imaging diagnostics. The aim of the following study was to evaluate the imaging of endodontic structures with CBCT. One hundred and twenty teeth were examined with a CBCT device (ProMax 3D). Subsequently, the findings of the three-dimensional images were evaluated and compared to those of dental radiographs and tangential section preparations of the examined teeth. Results with high prevalence, such as existing roots and root canals, as well as results with low prevalence, e.g., extremely fine anatomical structures of the endodontic tissue, could be visualized precisely by dental CBCT; side canals, ramifications, communications, pulp stones, and obliterations could also be detected. Additionally, the length of curved root canals could be determined accurately. Likewise, root fractures were visualized reliably with CBCT. However, carious lesions could not be diagnosed adequately, and the evaluation of fillings and prosthetic restorations was complicated due to scattered X-ray artifacts. CBCT datasets qualify to visualize and diagnose small anatomical structures of the endodontic tissue.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Cavidade Pulpar/diagnóstico por imagem , Imageamento Tridimensional , Radiografia Dentária , Tratamento do Canal Radicular , Cavidade Pulpar/anormalidades , Humanos , Sensibilidade e Especificidade
15.
Clin Oral Investig ; 19(4): 781-90, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25074723

RESUMO

OBJECTIVES: The widely used panoramic radiography as a special kind of tomography underlies intrinsic procedural restrictions such as poor definition, inconsistent magnification, geometric distortion and spatial depositioning of objects situated outside the focal trough. This results in a non-anatomic display of the radiographed anatomic structures. Individual mandibular angle and width of the jaws, adjustment of the focal trough, jaw incongruence as well as patient positioning increase the inconsistency in display of the radiographed objects. This study precisely evaluated the quantitative impact of object malpositioning on the display in panoramic radiography. MATERIALS AND METHODS: A special dental implant model was highly accurate three dimensionally malpositioned and panoramic radiographs were taken. Automated image analysis was performed to exclude subjective assessment error. RESULTS: Precise and retraceable object deposition of up to 5 mm or 5° resulted in relevant deposition of objects and significant changes in object size and inter-object distances in the panoramic image. Unidirectional malpositioning lead to multiple errors in display. CONCLUSIONS: The extent of malpositioning-related display errors additionally to the known physicotechnical insufficiencies of the panoramic radiography demonstrates its limitations in precisely interpreting spatial relationships. CLINICAL RELEVANCE: Measurements within the panoramic radiography must not claim reliability. For a single object securely positioned in the focal trough and perpendicular to the central X-ray beam, measurements may be trustworthy on clinical scale. Once sterical relationships to other structures are evaluated, reliability must be questioned.


Assuntos
Implantes Dentários , Ampliação Radiográfica/normas , Desenho de Equipamento , Humanos , Radiografia Panorâmica/normas , Reprodutibilidade dos Testes
16.
Anal Chem ; 86(13): 6525-32, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24856175

RESUMO

To manage and inform diagnostic or therapeutic decisions, measurement results which are accurate, specific, and comparable between laboratories are required. Two challenges associated with this are the definition of the measurand and the commutability of the reference standard used. Once the measurand is defined, the next step in improving standardization is developing traceable quantification methods for proteins in biological fluids. A novel reference method for the quantification of recombinant human growth hormone (rhGH) in serum has been developed using multistep sample cleanup at the protein level, tryptic digestion, and isotope dilution mass spectrometry (IDMS). Critical considerations for using isotopically labeled rhGH as the internal standard are described. A bulk serum sample was prepared at the clinically relevant level of 10 ng/g and quantified using the method described to give results traceable to the International System of Units (SI) with a total measurement uncertainty of <20%. Results compared favorably with an orthogonal traceable method using total tryptic digestion, peptide separation, and isotope dilution mass spectrometry.


Assuntos
Hormônio do Crescimento Humano/sangue , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Cromatografia Líquida , Hormônio do Crescimento Humano/análise , Humanos , Marcação por Isótopo , Isótopos/análise , Isótopos/sangue , Limite de Detecção , Dados de Sequência Molecular , Proteínas Recombinantes/análise , Proteínas Recombinantes/sangue , Padrões de Referência , Espectrometria de Massas em Tandem/normas
17.
Clin Oral Investig ; 17(2): 389-96, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22431146

RESUMO

OBJECTIVES: The objective of this study is to develop a new approach for radiographically measuring circumferential periodontal bone level using cone beam CT (CBCT) data. Accuracy and precision were assessed using direct probe measurements on a human skull as a reference. MATERIALS AND METHODS: Digital quantification of circumferential periodontal bone levels was conducted considering bone level measurements, infrabony crater, and furcation detection. For this purpose, a human bony cadaver skull with a restoration free dentition was used, showing periodontal bony defects of teeth 15-17,25-27,35-37,45-47 (FDI classification). Image datasets were acquired using a Promax 3D CBCT device (Planmeca Oy, Helsinki, Finland) at 80 kV and 8 mA, 160 µm voxel size. Circumferential radiographic measurements between cemento-enamel junction and the alveolar crest for the mesial, central, and distal bone levels on the oral and vestibular sides of the examined teeth were carried out based on a prototype of specifically developed software. The measurements were performed by an expert panel of three independent, calibrated, and blinded observers. Manual probe measurements of the periodontal bone loss served as reference standard. RESULTS: The adopted software allowed the quantification of periodontal bone loss at all examined teeth. Overall deviation between radiographic and manual measurements of the observers ranged between 0.36 and 0.69 mm; hereby, 83 % of all results were <0.5 mm. Comparing overall accuracy between the ten turns of radiological measurements, accuracy for all observers ranged from 0.29 to 0.46 mm. The present study design showed a 100 % detection of furcation involvement for radiographic evaluation. CONCLUSIONS: The adoption of a special measurement procedure in terms of a 3D coordinate system, which is placed through and perpendicular to the long axis of the tooth, allows consistent measurement positions of the mesial, central, and distal bone levels both for the oral and vestibular sides of the alveolar crest. In this way, reliable and reproducible quantification of circumferential periodontal bone loss using CBCT data with standardized resolution of 160 µm can be performed in all three dimensions. CLINICAL RELEVANCE: This new approach of radiographically assessing circumferential periodontal bone level using CBCT data shows a first promising attempt of accurate detection of periodontal bony defects. Yet, possible negative impact of further clinical parameters in terms of artifact occurrence will have to be furthermore carefully investigated.


Assuntos
Perda do Osso Alveolar/diagnóstico por imagem , Processo Alveolar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Defeitos da Furca/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Pontos de Referência Anatômicos/diagnóstico por imagem , Cadáver , Cefalometria/estatística & dados numéricos , Humanos , Imageamento Tridimensional/estatística & dados numéricos , Variações Dependentes do Observador , Periodontia/instrumentação , Software/estatística & dados numéricos , Colo do Dente/diagnóstico por imagem
18.
J Mass Spectrom ; 47(12): 1554-60, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23280743

RESUMO

Amphiphilic peptide conjugation affords a significant increase in sensitivity with protein quantification by electrospray-ionization mass spectrometry. This has been demonstrated for human growth hormone (GH) in serum using N-(3-iodopropyl)-N,N,N-dimethyloctylammonium iodide as derivatizing reagent. The signal enhancement achieved is up to a factor of 5-6 and enables extension of the applicable concentration range down to the very low concentrations (≤ 1.0 µg/L) as encountered with clinical glucose suppression tests for patients with acromegaly. The method has been validated using a set of serum samples spiked with known amounts of recombinant 22 kDa GH in the range of 0.48 to 7.65 µg/L. The coefficient of variation (CV) calculated based on the deviation of results from the expected concentrations was 3.5%. The limit of detection (LoD) was determined as 0.1 µg/L and the limit of quantification (LoQ) as 0.4 µg/L. The potential of the method as a tool in clinical practice has been demonstrated with patient samples of about 1 µg/L.


Assuntos
Hormônio do Crescimento Humano/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida , Humanos , Proteômica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
J Oral Maxillofac Surg ; 69(11): 2763-70, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21703745

RESUMO

PURPOSE: The aim of this study was to investigate bone mass using different cone-beam computed tomographies (CBCTs) combined with image analysis and to determine whether bone quantity or quality was detected. MATERIALS AND METHODS: Different measurements recorded on mandible bones of pigs in the retromolar region were evaluated on ProMax 3D (Planmeca Oy, Finland) and the ILUMA™CT (IMTEC™ Imaging, Ardmore, OK) to calculate a calibration curve. The spatial relationships of pig mandible halves relative to adjacent defined anatomical structures were assessed by means of 3D visualization software. In addition to the screenshot, their bone quality was evaluated in accordance with the Lenkholm and Zarb classification. RESULTS: The CBCT calibration curves based on the measurements taken from the ProMax and ILUMA CT showed linear correlation. Huge Hounsfield units intervals were found between the 2 CBCTs and there was no correlation with the computed tomography. Exact information on the micromorphology of the bone cylinders was not available. A subjective correlation according to Lenkholm and Zarb showed overlapping in all groups. CONCLUSIONS: CBCT is a good choice for analyzing bone mass. However, it does not provide any information on bone quality. To obtain information on the microarchitecture of the spongiosa, it is necessary to use a computed tomography with finite element analysis.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Mandíbula/diagnóstico por imagem , Animais , Densidade Óssea/fisiologia , Calibragem , Tomografia Computadorizada de Feixe Cônico/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Sistemas de Informação em Radiologia , Software , Suínos
20.
Eur J Radiol ; 79(2): 277-82, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20185261

RESUMO

AIMS: To investigate the diagnostic quality of different quality, individually calibrated ink-jet printers for the very challenging dental radiographic task of approximal carious lesion detection. MATERIALS AND METHODS: A test-pattern evaluating resolution, contrast and homogeneity of the ink-jet prints was developed. 50 standardized dental radiographs each showing two neighbouring teeth in natural contact were printed on glossy paper with calibrated, randomly selected ink-jet printers (Canon S520 and iP4500, Epson Stylus Photo R2400). Printing size equalled the viewing size on a 17″ cathode-ray-tube monitor daily quality-tested according to German regulations. The true caries status was determined from serial sectioning and microscopic evaluation. 16 experienced observers evaluated the radiographs on a five-point confidence scale on all prints plus the viewing monitor with respect to the visibility of a carious lesion. A non-parametric Receiver-Operating Characteristics (ROC-) analysis was performed explicitly designed for the evaluation of readings stemming from identical samples but different modality. Significant differences are expressed by a critical ratio z exceeding ±2. Diagnostic accuracy was determined by the area (Az) underneath the ROC-curves. RESULTS: Average Az-values ranged between 0.62 (S520 and R2400) and 0.64 (monitor, iP4500), with no significant difference between modalities (P=0.172). Neither significant (range mean z: -0.40 (S520) and -0.11 (iP4500)) nor clinically relevant differences were found between printers and viewing monitor. CONCLUSIONS: Our results for a challenging task in dental radiography indicate that calibrated, off-the-shelf ink-jet printers are able to reproduce (dental) radiographs at quality levels sufficient for radiographic diagnosis in a typical dental working environment.


Assuntos
Periféricos de Computador , Cárie Dentária/diagnóstico por imagem , Impressão/instrumentação , Radiografia Dentária Digital , Humanos , Tinta , Papel , Curva ROC , Reprodutibilidade dos Testes