Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Biol Eng Comput ; 56(8): 1499-1514, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29392547

RESUMO

Vibroarthrography is a radiation-free and inexpensive method of assessing the condition of knee cartilage damage during extension-flexion movements. Acoustic sensors were placed on the patella and medial tibial plateau (two accelerometers) as well as on the lateral tibial plateau (a piezoelectric disk) to measure the structure-borne noise in 59 asymptomatic knees and 40 knees with osteoarthritis. After semi-automatic segmentation of the acoustic signals, frequency features were generated for the extension as well as the flexion phase. We propose simple and robust features based on relative high-frequency components. The normalized nature of these frequency features makes them insusceptible to influences on the signal gain, such as attenuation by fat tissue and variance in acoustic coupling. We analyzed their ability to serve as classification features for detection of knee osteoarthritis, including the effect of normalization and the effect of combining frequency features of all three sensors. The features permitted a distinction between asymptomatic and non-healthy knees. Using machine learning with a linear support vector machine, a classification specificity of approximately 0.8 at a sensitivity of 0.75 could be achieved. This classification performance is comparable to existing diagnostic tests and hence qualifies vibroarthrography as an additional diagnostic tool. Graphical Abstract Acoustic frequency features were used to detect knee osteoarthritis at 80% specificity and 75% sensitivity.


Assuntos
Artrografia , Osteoartrite do Joelho/diagnóstico , Vibração , Adulto , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Probabilidade , Curva ROC , Processamento de Sinais Assistido por Computador , Máquina de Vetores de Suporte
2.
Artigo em Inglês | MEDLINE | ID: mdl-28790104

RESUMO

BACKGROUND: Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) imaging can be used to evaluate characteristics of atrial fibrosis. The novel noninvasive epicardial and endocardial electrophysiology system (NEEES) allows for the identification of sources with rotor activity. This study describes a new technique to examine the relationship between rotors and LGE signal intensity in patients with persistent atrial fibrillation (PERS) scheduled for ablation. METHODS AND RESULTS: Ten consecutive patients underwent pulmonary vein isolation for persistent atrial fibrillation. LGE CMR of both atria was performed, and NEEES-based analysis was conducted to identify rotors. For each mapping point, the intracardiac locations were transferred onto an individual CMR-derived 3-dimensional shell. This allowed the LGE signal intensity to be projected onto the anatomy from the NEEES analysis. NEEES analysis identified a total number of 410 electric rotors, 47.8% were located in the left atrium and 52.2% in the right atrium. Magnetic resonance imaging analysis was performed from 10 right atria and 10 left atria data sets, including 86 axial LGE CMR planes per atrium. The mean LGE burden for left atrium and right atrium was 23.9±1.6% and 15.9±1.8%, respectively. Statistical analysis demonstrated a lack of regional association between the extent of LGE signal intensity and the presence of rotors. CONCLUSIONS: This is the first study demonstrating that the presence of rotors based on NEEES analysis is not directly associated with the extent and anatomic location of LGE signal intensity from CMR. Further studies evaluating the relationship between rotors and fibrosis in patients with persistent atrial fibrillation are mandatory and may inform strategies to improve ablation outcome.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Meios de Contraste/farmacologia , Técnicas Eletrofisiológicas Cardíacas , Gadolínio/farmacologia , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Idoso , Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia
3.
Comput Math Methods Med ; 2017: 9295029, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28373893

RESUMO

The most important ECG marker for the diagnosis of ischemia or infarction is a change in the ST segment. Baseline wander is a typical artifact that corrupts the recorded ECG and can hinder the correct diagnosis of such diseases. For the purpose of finding the best suited filter for the removal of baseline wander, the ground truth about the ST change prior to the corrupting artifact and the subsequent filtering process is needed. In order to create the desired reference, we used a large simulation study that allowed us to represent the ischemic heart at a multiscale level from the cardiac myocyte to the surface ECG. We also created a realistic model of baseline wander to evaluate five filtering techniques commonly used in literature. In the simulation study, we included a total of 5.5 million signals coming from 765 electrophysiological setups. We found that the best performing method was the wavelet-based baseline cancellation. However, for medical applications, the Butterworth high-pass filter is the better choice because it is computationally cheap and almost as accurate. Even though all methods modify the ST segment up to some extent, they were all proved to be better than leaving baseline wander unfiltered.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia/métodos , Processamento de Sinais Assistido por Computador , Artefatos , Simulação por Computador , Humanos
4.
Med Biol Eng Comput ; 55(6): 979-990, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27651061

RESUMO

ECG imaging is an emerging technology for the reconstruction of cardiac electric activity from non-invasively measured body surface potential maps. In this case report, we present the first evaluation of transmurally imaged activation times against endocardially reconstructed isochrones for a case of sustained monomorphic ventricular tachycardia (VT). Computer models of the thorax and whole heart were produced from MR images. A recently published approach was applied to facilitate electrode localization in the catheter laboratory, which allows for the acquisition of body surface potential maps while performing non-contact mapping for the reconstruction of local activation times. ECG imaging was then realized using Tikhonov regularization with spatio-temporal smoothing as proposed by Huiskamp and Greensite and further with the spline-based approach by Erem et al. Activation times were computed from transmurally reconstructed transmembrane voltages. The results showed good qualitative agreement between the non-invasively and invasively reconstructed activation times. Also, low amplitudes in the imaged transmembrane voltages were found to correlate with volumes of scar and grey zone in delayed gadolinium enhancement cardiac MR. The study underlines the ability of ECG imaging to produce activation times of ventricular electric activity-and to represent effects of scar tissue in the imaged transmembrane voltages.


Assuntos
Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Ventrículos do Coração/fisiopatologia , Humanos , Imageamento por Ressonância Magnética/métodos , Tórax/fisiologia
5.
Biomed Res Int ; 2015: 530352, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26587538

RESUMO

In case of chest pain, immediate diagnosis of myocardial ischemia is required to respond with an appropriate treatment. The diagnostic capability of the electrocardiogram (ECG), however, is strongly limited for ischemic events that do not lead to ST elevation. This computational study investigates the potential of different electrode setups in detecting early ischemia at 10 minutes after onset: standard 3-channel and 12-lead ECG as well as body surface potential maps (BSPMs). Further, it was assessed if an additional ECG electrode with optimized position or the right-sided Wilson leads can improve sensitivity of the standard 12-lead ECG. To this end, a simulation study was performed for 765 different locations and sizes of ischemia in the left ventricle. Improvements by adding a single, subject specifically optimized electrode were similar to those of the BSPM: 2-11% increased detection rate depending on the desired specificity. Adding right-sided Wilson leads had negligible effect. Absence of ST deviation could not be related to specific locations of the ischemic region or its transmurality. As alternative to the ST time integral as a feature of ST deviation, the K point deviation was introduced: the baseline deviation at the minimum of the ST-segment envelope signal, which increased 12-lead detection rate by 7% for a reasonable threshold.


Assuntos
Simulação por Computador , Eletrocardiografia/métodos , Modelos Cardiovasculares , Isquemia Miocárdica/fisiopatologia , Eletrodos , Humanos
6.
Biomed Tech (Berl) ; 59(6): 515-28, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25229412

RESUMO

Electrocardiographic imaging (ECG imaging) is a method to depict electrophysiological processes in the heart. It is an emerging technology with the potential of making the therapy of cardiac arrhythmia less invasive, less expensive, and more precise. A major challenge for integrating the method into clinical workflow is the seamless and correct identification and localization of electrodes on the thorax and their assignment to recorded channels. This work proposes a camera-based system, which can localize all electrode positions at once and to an accuracy of approximately 1 ± 1 mm. A system for automatic identification of individual electrodes is implemented that overcomes the need of manual annotation. For this purpose, a system of markers is suggested, which facilitates a precise localization to subpixel accuracy and robust identification using an error-correcting code. The accuracy of the presented system in identifying and localizing electrodes is validated in a phantom study. Its overall capability is demonstrated in a clinical scenario.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Eletrocardiografia/métodos , Eletrodos , Fotogrametria/métodos , Tórax/anatomia & histologia , Algoritmos , Mapeamento Potencial de Superfície Corporal/instrumentação , Eletrocardiografia/instrumentação , Marcadores Fiduciais , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Med Biol Eng Comput ; 52(9): 717-28, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25008005

RESUMO

The goal of ECG-imaging (ECGI) is to reconstruct heart electrical activity from body surface potential maps. The problem is ill-posed, which means that it is extremely sensitive to measurement and modeling errors. The most commonly used method to tackle this obstacle is Tikhonov regularization, which consists in converting the original problem into a well-posed one by adding a penalty term. The method, despite all its practical advantages, has however a serious drawback: The obtained solution is often over-smoothed, which can hinder precise clinical diagnosis and treatment planning. In this paper, we apply a binary optimization approach to the transmembrane voltage (TMV)-based problem. For this, we assume the TMV to take two possible values according to a heart abnormality under consideration. In this work, we investigate the localization of simulated ischemic areas and ectopic foci and one clinical infarction case. This affects only the choice of the binary values, while the core of the algorithms remains the same, making the approximation easily adjustable to the application needs. Two methods, a hybrid metaheuristic approach and the difference of convex functions (DC), algorithm were tested. For this purpose, we performed realistic heart simulations for a complex thorax model and applied the proposed techniques to the obtained ECG signals. Both methods enabled localization of the areas of interest, hence showing their potential for application in ECGI. For the metaheuristic algorithm, it was necessary to subdivide the heart into regions in order to obtain a stable solution unsusceptible to the errors, while the analytical DC scheme can be efficiently applied for higher dimensional problems. With the DC method, we also successfully reconstructed the activation pattern and origin of a simulated extrasystole. In addition, the DC algorithm enables iterative adjustment of binary values ensuring robust performance.


Assuntos
Eletrocardiografia/métodos , Modelos Cardiovasculares , Adulto , Algoritmos , Mapeamento Potencial de Superfície Corporal , Simulação por Computador , Coração , Humanos , Processamento de Imagem Assistida por Computador , Masculino
8.
Med Biol Eng Comput ; 51(11): 1251-60, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23070728

RESUMO

Computational atrial models aid the understanding of pathological mechanisms and therapeutic measures in basic research. The use of biophysical models in a clinical environment requires methods to personalize the anatomy and electrophysiology (EP). Strategies for the automation of model generation and for evaluation are needed. In this manuscript, the current efforts of clinical atrial modeling in the euHeart project are summarized within the context of recent publications in this field. Model-based segmentation methods allow for the automatic generation of ready-to-simulate patient-specific anatomical models. EP models can be adapted to patient groups based on a-priori knowledge and to the individual without significant further data acquisition. ECG and intracardiac data build the basis for excitation personalization. Information from late enhancement (LE) MRI can be used to evaluate the success of radio-frequency ablation (RFA) procedures and interactive virtual atria pave the way for RFA planning. Atrial modeling is currently in a transition from the sole use in basic research to future clinical applications. The proposed methods build the framework for model-based diagnosis and therapy evaluation and planning. Complex models allow to understand biophysical mechanisms and enable the development of simplified models for clinical applications.


Assuntos
Função Atrial/fisiologia , Coração/anatomia & histologia , Modelos Cardiovasculares , Medicina de Precisão/métodos , Fibrilação Atrial/patologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Ablação por Cateter , Simulação por Computador , Eletrocardiografia , Átrios do Coração/anatomia & histologia , Humanos , Imageamento por Ressonância Magnética
9.
Interface Focus ; 1(3): 349-64, 2011 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-22670205

RESUMO

The loss of cardiac pump function accounts for a significant increase in both mortality and morbidity in Western society, where there is currently a one in four lifetime risk, and costs associated with acute and long-term hospital treatments are accelerating. The significance of cardiac disease has motivated the application of state-of-the-art clinical imaging techniques and functional signal analysis to aid diagnosis and clinical planning. Measurements of cardiac function currently provide high-resolution datasets for characterizing cardiac patients. However, the clinical practice of using population-based metrics derived from separate image or signal-based datasets often indicates contradictory treatments plans owing to inter-individual variability in pathophysiology. To address this issue, the goal of our work, demonstrated in this study through four specific clinical applications, is to integrate multiple types of functional data into a consistent framework using multi-scale computational modelling.

10.
Artigo em Inglês | MEDLINE | ID: mdl-22255296

RESUMO

A framework for step-by-step personalization of a computational model of human atria is presented. Beginning with anatomical modeling based on CT or MRI data, next fiber structure is superimposed using a rule-based method. If available, late-enhancement-MRI images can be considered in order to mark fibrotic tissue. A first estimate of individual electrophysiology is gained from BSPM data solving the inverse problem of ECG. A final adjustment of electrophysiology is realized using intracardiac measurements. The framework is applied using several patient data. First clinical application will be computer assisted planning of RF-ablation for treatment of atrial flutter and atrial fibrillation.


Assuntos
Simulação por Computador , Átrios do Coração/anatomia & histologia , Modelos Anatômicos , Eletrocardiografia , Humanos , Imageamento por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...