Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38658269

RESUMO

OBJECTIVES: We sought to investigate the impact of sex on myocardial perfusion changes following chronic total coronary occlusion (CTO) percutaneous coronary intervention (PCI) as measured by [15O]H2O positron-emission tomography (PET) perfusion imaging. BACKGROUND: CTO PCI has been associated with an increase in myocardial perfusion, yet females are less likely to undergo revascularization. As such, data on the impact of sex on myocardial perfusion following CTO PCI is scarce. METHODS: A total of 212 patients were prospectively enrolled and underwent CTO PCI combined with [15O]H2O PET perfusion imaging prior to and 3 months after PCI. Hyperemic myocardial blood flow (hMBF, mL·min-1·g-1) and coronary flow reserve (CFR) allocated to the CTO territory were quantitatively assessed. RESULTS: This study comprised 34 (16 %) females and 178 (84 %) males. HMBF at baseline did not differ between sexes. Females showed a higher increase in hMBF than males (Δ1.34 ± 0.67 vs. Δ1.06 ± 0.74, p = 0.044), whereas post-PCI hMBF was comparable (2.59 ± 0.85 in females vs. 2.28 ± 0.84 in males, p = 0.052). Female sex was independently associated with a higher increase in hMBF after correction for clinical covariates. CFR increase after revascularization was similar in females and males (Δ1.47 ± 0.99 vs. Δ1.30 ± 1.14, p = 0.711). CONCLUSIONS: The present study demonstrates a greater recovery of stress perfusion in females compared to males as measured by serial [15O]H2O PET imaging. In addition, a comparable increase in CFR was found in females and males. These results emphasize the benefit of performing CTO PCI in both sexes. CLINICAL PERSPECTIVE: What is new? What are the clinical implications?

2.
Sci Rep ; 14(1): 915, 2024 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-38195696

RESUMO

Fungus-resistant grapevine cultivars, so called PIWIs, are characterized by increased resistance to powdery mildew and downy mildew. However, in order to maintain the durability of resistance in these new grape cultivars, targeted fungicide treatments are recommended. For ideal schedule of these treatments, it is necessary to recognize the most sensitive organs of the grape. This study introduces a method for phenotypic evaluation of Plasmopara viticola resistance in grape clusters under controlled and standardized conditions during phenological development over the entire season. The approach was validated with the traditional cultivar Pinot Noir and the PIWIs Cabernet Cortis (Rpv3.3, Rpv10), Solaris (Rpv3.3, Rpv10) and Souvignier Gris (Rpv3.2). All cultivars were susceptible during the early stages of development up to flowering, and resistance levels increased as phenological development progressed. Cabernet Cortis and Solaris clusters were susceptible until fruit development (BBCH 71-73) when they became almost completely resistant. No differences between Souvignier Gris and Pinot Noir were detected until berries were pea-sized (BBCH 75) when P. viticola resistance of Souvignier Gris clusters increased significantly. Ontogenetic resistance in Pinot Noir was detected at berry touch (BBCH 77-79) and clusters of this cultivar were almost completely resistant at the beginning of ripening (BBCH 81-83). These results indicate that the approach presented is suitable for determining the resistance of grape cultivars at different stages of development. Consequently, in the future, fungicide applications can be adjusted more precisely to the resistance level of a grape cultivar during the growing season.


Assuntos
Fungicidas Industriais , Fungicidas Industriais/farmacologia , Erysiphe , Frutas , Reprodução , Estações do Ano
3.
J Am Chem Soc ; 146(7): 4542-4548, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38295022

RESUMO

The control and active manipulation of spin-orbit coupling (SOC) in photonic systems are fundamental in the development of modern spin optics and topological photonic devices. Here, we demonstrate the control of an artificial Rashba-Dresselhaus (RD) SOC mediated by photochemical reactions in a microcavity filled with an organic single crystal of photochromic phase-change character. Splitting of the circular polarization components of the optical modes induced by photonic RD SOC is observed experimentally in momentum space. By applying an ultraviolet light beam, we control the spatial molecular orientation through a photochemical reaction, and with that we control the energies of the photonic modes. This way, we realize a reversible conversion of spin splitting of the optical modes with different energies, leading to an optically controlled switching between circularly and linearly polarized optical modes in our device. Our strategy of in situ and reversible engineering of SOC induced by a light field provides a promising approach to actively design and manipulate synthetic gauge fields toward future on-chip integration in photonics and topological photonic devices.

4.
Phys Chem Chem Phys ; 26(5): 4194-4199, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38230526

RESUMO

N-type electronic doping of organic semiconductors (OSCs) by using superbase compounds shows high doping efficiency (H. Wei, Z. Cheng, T. Wu, Y. Liu, J. Guo, P.-A. Chen, J. Xia, H. Xie, X. Qiu, T. Liu, B. Zhang, J. Hui, Z. Zeng, Y. Bai and Y. Hu, Adv. Mater. 2023, 35, 2300084). While a deprotonation reaction is believed to trigger the doping process, the detailed mechanism therein is not yet fully understood. In the present work we theoretically study the electronic structure of the deprotonated Phenyl-C61-butyric acid methyl ester (PCBM) molecule, as well as the charge transfer (CT) between PCBM and its deprotonated species. We find that deprotonated PCBM without formation of a new bond between the deprotonated side chain and fullerene induces electronic structure with broken spin symmetry, where an in-gap state is singly occupied by an unpaired electron. A second scenario that we find to be possible is the formation of a new bond between the deprotonated side chain and a fullerene. This leads to a spin symmetric electronic structure with partially localized in-gap state, which is expected to contribute less to the effective doping. These results show that the deprotonated PCBM species without new bond formation predominantly accounts for the effective n-type doping of PCBM, an insight that will be useful for optimization of this recently discovered doping method.

5.
J Nucl Med ; 65(2): 279-286, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38176722

RESUMO

In patients evaluated for obstructive coronary artery disease (CAD), guidelines recommend using either fractional flow reserve (FFR) or instantaneous wave-free ratio (iFR) to guide coronary revascularization decision-making. The hemodynamic significance of lesions with discordant FFR and iFR measurements is debated. This study compared [15O]H2O PET-derived absolute myocardial perfusion between vessels with concordant and discordant FFR and iFR measurements. Methods: We included 197 patients suspected of obstructive CAD who had undergone [15O]H2O PET perfusion imaging and combined FFR/iFR interrogation in 468 vessels. Resting myocardial blood flow (MBF), hyperemic MBF, and coronary flow reserve (CFR) were compared among 4 groups: FFR low/iFR low (n = 79), FFR high/iFR low (n = 22), FFR low/iFR high (n = 22), and FFR high/iFR high (n = 345). Predefined [15O]H2O PET thresholds for ischemia were 2.3 mL·min-1·g-1 or less for hyperemic MBF and 2.5 or less for CFR. Results: Hyperemic MBF was lower in the concordant low (2.09 ± 0.67 mL·min-1·g-1), FFR high/iFR low (2.41 ± 0.80 mL·min-1·g-1), and FFR low/iFR high (2.40 ± 0.69 mL·min-1·g-1) groups compared with the concordant high group (2.91 ± 0.84 mL·min-1·g-1) (P < 0.001, P = 0.004, and P < 0.001, respectively). A lower CFR was observed in the concordant low (2.37 ± 0.76) and FFR high/iFR low (2.64 ± 0.84) groups compared with the concordant high group (3.35 ± 1.07, P < 0.01 for both). However, for vessels with either low FFR or low iFR, quantitative hyperemic MBF and CFR values exceeded the ischemic threshold in 38% and 49%, respectively. In addition, resting MBF exhibited a negative correlation with iFR (P < 0.001) and was associated with FFR low/iFR high discordance compared with concordant low FFR/low iFR measurements, independent of clinical and angiographic characteristics, as well as hyperemic MBF (odds ratio [OR], 0.41; 95% CI, 0.26-0.65; P < 0.001). Conclusion: We found reduced myocardial perfusion in vessels with concordant low and discordant FFR/iFR measurements. However, FFR/iFR combinations often inaccurately classified vessels as either ischemic or nonischemic when compared with hyperemic MBF and CFR. Furthermore, a lower resting MBF was associated with a higher iFR and the occurrence of FFR low/iFR high discordance. Our study showed that although combined FFR/iFR assessment can be useful to estimate the hemodynamic significance of coronary lesions, these pressure-derived indices provide a limited approximation of [15O]H2O PET-derived quantitative myocardial perfusion as the physiologic standard of CAD severity.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Hemodinâmica , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Vasos Coronários
6.
Phys Rev Lett ; 131(13): 136901, 2023 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-37831991

RESUMO

Manipulating bosonic condensates with electric fields is very challenging as the electric fields do not directly interact with the neutral particles of the condensate. Here we demonstrate a simple electric method to tune the vorticity of exciton-polariton condensates in a strong coupling liquid crystal (LC) microcavity with CsPbBr_{3} microplates as active material at room temperature. In such a microcavity, the LC molecular director can be electrically modulated giving control over the polariton condensation in different modes. For isotropic nonresonant optical pumping we demonstrate the spontaneous formation of vortices with topological charges of +1, +2, -2, and -1. The topological vortex charge is controlled by a voltage in the range of 1 to 10 V applied to the microcavity sample. This control is achieved by the interplay of a built-in potential gradient, the anisotropy of the optically active perovskite microplates, and the electrically controllable LC molecular director in our system with intentionally broken rotational symmetry. Besides the fundamental interest in the achieved electric polariton vortex control at room temperature, our work paves the way to micron-sized emitters with electric control over the emitted light's phase profile and quantized orbital angular momentum for information processing and integration into photonic circuits.

7.
Circ Cardiovasc Imaging ; 16(9): e014845, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37725672

RESUMO

BACKGROUND: Coronary flow capacity (CFC) is a measure that integrates hyperemic myocardial blood flow and coronary flow reserve to quantify the pathophysiological impact of coronary artery disease on vasodilator capacity. This study explores the prognostic value of modified CFC derived from [15O]H2O positron emission tomography perfusion imaging. METHODS: Quantitative rest/stress perfusion measurements were obtained from 1300 patients with known or suspected coronary artery disease. Patients were classified as having myocardial steal (n=38), severely reduced CFC (n=141), moderately reduced CFC (n=394), minimally reduced CFC (n=245), or normal flow (n=482) using previously defined thresholds. The end point was a composite of death and nonfatal myocardial infarction. RESULTS: During a median follow-up of 5.5 (interquartile range, 3.7-7.8) years, the end point occurred in 153 (12%) patients. Myocardial steal (hazard ratio [HR], 6.70 [95% CI, 3.21-13.99]; P<0.001), severely reduced CFC (HR, 2.35 [95% CI, 1.16-4.78]; P=0.018), and moderately reduced CFC (HR, 1.95 [95% CI, 1.11-3.41]; P=0.020) were associated with worse prognosis compared with normal flow, after adjusting for clinical characteristics. Similarly, in the overall population, increased resting myocardial blood flow (HR, 3.05 [95% CI, 1.68-5.54]; P<0.001), decreased hyperemic myocardial blood flow (HR, 0.68 [95% CI, 0.52-0.90]; P=0.007) and decreased coronary flow reserve (HR, 0.55 [95% CI, 0.42-0.71]; P<0.001) were independently associated with adverse outcome. In a model adjusted for the combined use of perfusion metrics, modified CFC demonstrated independent prognostic value (overall P=0.017). CONCLUSIONS: [15O]H2O positron emission tomography-derived resting myocardial blood flow, hyperemic myocardial blood flow, coronary flow reserve, and CFC are prognostic factors for death and nonfatal myocardial infarction in patients with known or suspected coronary artery disease. Importantly, after adjustment for clinical characteristics and the combined use of [15O]H2O positron emission tomography perfusion metrics, modified CFC remained independently associated with adverse outcome.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Prognóstico , Perfusão , Tomografia por Emissão de Pósitrons , Imagem de Perfusão
8.
Catheter Cardiovasc Interv ; 102(5): 844-856, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37671770

RESUMO

BACKGROUND: The Japanese Channel (J-Channel) score was introduced to aid in retrograde percutaneous coronary intervention (PCI) of chronic total coronary occlusions (CTOs). The predictive value of the J-Channel score has not been compared with established collateral grading systems such as the Rentrop classification and Werner grade. AIMS: To investigate the predictive value of the J-Channel score, Rentrop classification and Werner grade for successful collateral channel (CC) guidewire crossing and technical CTO PCI success. METHODS: A total of 600 prospectively recruited patients underwent CTO PCI. All grading systems were assessed under dual catheter injection. CC guidewire crossing was considered successful if the guidewire reached the distal segment of the CTO vessel through a retrograde approach. Technical CTO PCI success was defined as thrombolysis in myocardial infarction flow grade 3 and residual stenosis <30%. RESULTS: Of 600 patients, 257 (43%) underwent CTO PCI through a retrograde approach. Successful CC guidewire crossing was achieved in 208 (81%) patients. The predictive value of the J-Channel score for CC guidewire crossing (area under curve 0.743) was comparable with the Rentrop classification (0.699, p = 0.094) and superior to the Werner grade (0.663, p = 0.002). Technical CTO PCI success was reported in 232 (90%) patients. The Rentrop classification exhibited a numerically higher discriminatory ability (0.676) compared to the J-Channel score (0.664) and Werner grade (0.589). CONCLUSIONS: The J-channel score might aid in strategic collateral channel selection during retrograde CTO PCI. However, the J-Channel score, Rentrop classification, and Werner grade have limited value in predicting technical CTO PCI success.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Angiografia Coronária , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Fatores de Risco , Sistema de Registros
9.
Eur Heart J Cardiovasc Imaging ; 25(1): 116-126, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-37578007

RESUMO

AIMS: In chronic coronary syndrome (CCS) patients with documented coronary artery disease (CAD), ischaemia detection by myocardial perfusion imaging (MPI) and an invasive approach are viable diagnostic strategies. We compared the diagnostic performance of quantitative flow ratio (QFR) with single-photon emission computed tomography (SPECT), positron emission tomography (PET), and cardiac magnetic resonance imaging (CMR) in patients with prior CAD [previous percutaneous coronary intervention (PCI) and/or myocardial infarction (MI)]. METHODS AND RESULTS: This PACIFIC-2 sub-study evaluated 189 CCS patients with prior CAD for inclusion. Patients underwent SPECT, PET, and CMR followed by invasive coronary angiography with fractional flow reserve (FFR) measurements of all major coronary arteries (N = 567), except for vessels with a sub-total or chronic total occlusion. Quantitative flow ratio computation was attempted in 488 (86%) vessels with measured FFR available (FFR ≤0.80 defined haemodynamically significant CAD). Quantitative flow ratio analysis was successful in 334 (68%) vessels among 166 patients and demonstrated a higher accuracy (84%) and sensitivity (72%) compared with SPECT (66%, P < 0.001 and 46%, P = 0.001), PET (65%, P < 0.001 and 58%, P = 0.032), and CMR (72%, P < 0.001 and 33%, P < 0.001). The specificity of QFR (87%) was similar to that of CMR (83%, P = 0.123) but higher than that of SPECT (71%, P < 0.001) and PET (67%, P < 0.001). Lastly, QFR exhibited a higher area under the receiver operating characteristic curve (0.89) than SPECT (0.57, P < 0.001), PET (0.66, P < 0.001), and CMR (0.60, P < 0.001). CONCLUSION: QFR correlated better with FFR in patients with prior CAD than MPI, as reflected in the higher diagnostic performance measures for detecting FFR-defined, vessel-specific, significant CAD.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Angiografia Coronária/métodos , Imagem de Perfusão do Miocárdio/métodos , Valor Preditivo dos Testes
10.
Atherosclerosis ; 381: 117174, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37400307

RESUMO

BACKGROUND AND AIMS: Myocardial perfusion imaging (MPI) and anatomical imaging with coronary computed tomography angiography (CCTA) can play an important role in the preprocedural planning of a chronic total occlusion (CTO) percutaneous coronary intervention (PCI). We aimed to establish the feasibility of a novel dynamic computed tomography perfusion (CTP) analysis for the assessment of myocardial perfusion before and after a successful recanalization of CTO in patients undergoing CCTA as part of a standard preprocedural workup. METHODS: In a prospective observational study symptomatic patients underwent dynamic CTP on a dual-source CT scanner both before and 3 months after successful CTO PCI. RESULTS: Twenty-seven patients completed the study (63 ± 8 years old, 78% male). Following successful CTO PCI, there was a significant reduction in the ischemic burden (5 [5-7] versus 1 [0-2] segments, p < 0.001), and improvement in myocardial blood flow (85.3 [71.7-94.1] versus 134.6 [123.8-156.9] mL/min, p < 0.001) resulting in an increase in the relative flow reserve (0.49 [0.41-0.57] versus 0.88 [0.74-0.95], p < 0.001). CONCLUSIONS: CTP emerges as a robust and safe method for MPI in CTO patients. The single imaging session assessment of both coronary anatomy and perfusion with CT lends itself to precise disease phenotyping in the challenging population of CTO patients.


Assuntos
Oclusão Coronária , Imagem de Perfusão do Miocárdio , Intervenção Coronária Percutânea , Doenças Vasculares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Angiografia Coronária/métodos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Doença Crônica , Imagem de Perfusão do Miocárdio/métodos , Resultado do Tratamento
11.
Phys Rev Lett ; 130(11): 113601, 2023 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-37001069

RESUMO

Long-term quantum coherence constitutes one of the main challenges when engineering quantum devices. However, easily accessible means to quantify complex decoherence mechanisms are not readily available, nor are sufficiently stable systems. We harness novel phase-space methods-expressed through non-Gaussian convolutions of highly singular Glauber-Sudarshan quasiprobabilities-to dynamically monitor quantum coherence in polariton condensates with significantly enhanced coherence times. Via intensity- and time-resolved reconstructions of such phase-space functions from homodyne detection data, we probe the systems' resourcefulness for quantum information processing up to the nanosecond regime. Our experimental findings are confirmed through numerical simulations, for which we develop an approach that renders established algorithms compatible with our methodology. In contrast to commonly applied phase-space functions, our distributions can be directly sampled from measured data, including uncertainties, and yield a simple operational measure of quantum coherence via the distribution's variance in phase. Therefore, we present a broadly applicable framework and a platform to explore time-dependent quantum phenomena and resources.

12.
ACS Nano ; 17(5): 4230-4238, 2023 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-36812007

RESUMO

Two-dimensional (2D) layered materials provide an ideal platform for engineering electronic and optical properties through strain control because of their extremely high mechanical elasticity and sensitive dependence of material properties on mechanical strain. In this paper, a combined experimental and theoretical effort is made to investigate the effects of mechanical strain on various spectral features of bilayer MoTe2 photoluminescence (PL). We found that bilayer MoTe2 can be converted from an indirect to a direct bandgap material through strain engineering, resulting in a photoluminescence enhancement by a factor of 2.24. Over 90% of the PL comes from photons emitted by the direct excitons at the maximum strain applied. Importantly, we show that strain effects lead to a reduction of the overall linewidth of PL by as much as 36.6%. We attribute the dramatic decrease of linewidth to a strain-induced complex interplay among various excitonic varieties such as direct bright excitons, trions, and indirect excitons. Our experimental results on direct and indirect exciton emission features are explained by theoretical exciton energies that are based on first-principles electronic band structure calculations. The consistent theory-experimental trend shows that the enhancement of PL and the reduction of linewidth are the consequences of the increasing direct exciton contribution with the increase of strain. Our results demonstrate that strain engineering can lead to a PL quality of the bilayer MoTe2 comparable to that of the monolayer counterpart. The additional benefit of a longer emission wavelength makes the bilayer MoTe2 more suitable for silicon-photonics integration due to the reduced silicon absorption.

13.
J Am Chem Soc ; 145(3): 1557-1563, 2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36630440

RESUMO

Integrated electro-optical switches are essential as one of the fundamental elements in the development of modern optoelectronics. As an architecture for photonic systems exciton polaritons, hybrid bosonic quasiparticles that possess unique properties derived from both excitons and photons, have shown much promise. For this system, we demonstrate a significant improvement of emitted intensity and condensation threshold by applying an electric field to a microcavity filled with an organic microbelt. Our theoretical investigations indicate that the electric field makes the excitons dipolar and induces an enhancement of the exciton-polariton interaction and of the polariton lifetime. Based on these electric field-induced changes, a sub-nanosecond electrical field-enhanced polariton condensate switch is realized at room temperature, providing the basis for developing an on-chip integrated photonic device in the strong light-matter coupling regime.

14.
Nat Commun ; 14(1): 31, 2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36596798

RESUMO

Circularly polarized (CP) electroluminescence from organic light-emitting diodes (OLEDs) has aroused considerable attention for their potential in future display and photonic technologies. The development of CP-OLEDs relies largely on chiral-emitters, which not only remain rare owing to difficulties in design and synthesis but also limit the performance of electroluminescence. When the polarization (pseudospin) degrees of freedom of a photon interact with its orbital angular momentum, photonic spin-orbit interaction (SOI) emerges such as Rashba-Dresselhaus (RD) effect. Here, we demonstrate a chiral-emitter-free microcavity CP-OLED with a high dissymmetry factor (gEL) and high luminance by embedding a thin two-dimensional organic single crystal (2D-OSC) between two silver layers which serve as two metallic mirrors forming a microcavity and meanwhile also as two electrodes in an OLED architecture. In the presence of the RD effect, the SOIs in the birefringent 2D-OSC microcavity result in a controllable spin-splitting with CP dispersions. Thanks to the high emission efficiency and high carrier mobility of the OSC, chiral-emitter-free CP-OLEDs have been demonstrated exhibiting a high gEL of 1.1 and a maximum luminance of about 60000 cd/m2, which places our device among the best performing CP-OLEDs. This strategy opens an avenue for practical applications towards on-chip microcavity CP-OLEDs.

15.
Am Heart J ; 257: 20-29, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36410442

RESUMO

BACKGROUND: Patients with prior coronary artery bypass grafting (CABG) frequently require repeat percutaneous revascularization due to advanced age, progressive coronary artery disease and bypass graft failure. Percutaneous coronary intervention (PCI) of either the bypass graft or the native coronary artery may be performed. Randomized trials comparing native vessel PCI with bypass graft PCI are lacking and long-term outcomes have not been reported. METHODS: PROCTOR (NCT03805048) is a prospective, multicenter, randomized controlled trial, that will include 584 patients presenting with saphenous vein graft (SVG) failure and a clinical indication for revascularization, as determined by the local Heart Team. The trial is designed to compare the clinical and angiographic outcomes in patients randomly allocated in a 1:1 fashion to either a strategy of native vessel PCI or SVG PCI. The primary study endpoint is a 3-year composite of major adverse cardiac events (MACE: all-cause mortality, non-fatal target coronary territory myocardial infarction [MI], or clinically driven target coronary territory revascularization). At 3-years, after evaluation of the primary endpoint, follow-up invasive coronary angiography will be performed. Secondary endpoints comprise individual components of MACE at 1, 3 and 5 years follow-up, PCI-related MI, MI >48 hours after index PCI, target vessel failure, target lesion revascularization, renal failure requiring renal-replacement therapy, angiographic outcomes at 3-years and quality of life (delta Seattle Angina Questionnaire, Canadian Cardiovascular Society Grading Scale and Rose Dyspnea Scale). CONCLUSION: PROCTOR is the first randomized trial comparing an invasive strategy of native coronary artery PCI with SVG PCI in post-CABG patients presenting with SVG failure.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Estudos Prospectivos , Intervenção Coronária Percutânea/efeitos adversos , Veia Safena/transplante , Qualidade de Vida , Resultado do Tratamento , Stents Farmacológicos/efeitos adversos , Canadá , Ponte de Artéria Coronária/efeitos adversos , Infarto do Miocárdio/etiologia
16.
Adv Sci (Weinh) ; 9(29): e2203588, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35989095

RESUMO

Topological photonics provides an important platform for the development of photonic devices with robust disorder-immune light transport and controllable helicity. Mixing photons with excitons (or polaritons) gives rise to nontrivial polaritonic bands with chiral modes, allowing the manipulation of helical lasers in strongly coupled light-matter systems. In this work, helical polariton lasing from topological valleys of an organic anisotropic microcrystalline cavity based on tailored local nontrivial band geometry is demonstrated. This polariton laser emits light of different helicity along different angular directions. The significantly enhanced chiral characteristics are achieved by the nonlinear relaxation process. Helical topological polariton lasers may provide a perfect platform for the exploration of novel topological phenomena that involve light-matter interaction and the development of polariton-based spintronic devices.

17.
Curr Cardiol Rep ; 24(10): 1309-1325, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35925511

RESUMO

PURPOSE OF REVIEW: This review will outline the current evidence on the anatomical, functional, and physiological tools that may be applied in the evaluation of patients with late recurrent angina after coronary artery bypass grafting (CABG). Furthermore, we discuss management strategies and propose an algorithm to guide decision-making for this complex patient population. RECENT FINDINGS: Patients with prior CABG often present with late recurrent angina as a result of bypass graft failure and progression of native coronary artery disease (CAD). These patients are generally older, have a higher prevalence of comorbidities, and more complex atherosclerotic lesion morphology compared to CABG-naïve patients. In addition, guideline recommendations are based on studies in which post-CABG patients have been largely excluded. Several invasive and non-invasive diagnostic tools are currently available to assess graft patency, the hemodynamic significance of native CAD progression, left ventricular function, and myocardial viability. Such tools, in particular the latest generation coronary computed tomography angiography, are part of a systematic diagnostic work-up to guide optimal repeat revascularization strategy in patients presenting with late recurrent angina after CABG.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana , Angina Pectoris/diagnóstico , Angina Pectoris/etiologia , Angina Pectoris/terapia , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Humanos , Reoperação , Resultado do Tratamento
18.
Opt Lett ; 47(13): 3235-3238, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35776594

RESUMO

Vortices carrying quantized topological charges have potential applications in information processing. In this work, we investigate vortex carriers and waveguides in microcavity polariton condensates, nonresonantly excited by a homogeneous pump with intensity grooves. An intensity groove with a ring shape in the pump gives rise to dark-ring states of the condensate with a π-phase jump, akin to dark solitons. The dark-ring states can be destroyed by a stronger density of the surrounding condensate and reduce into vortex-antivortex pairs. Multiple vortex-pair states are found to be stable in the same dark ring of the pump. When the pump ring is broader, higher-order dark states with multiple π-phase jumps can be obtained, and interestingly they can be used to construct vortex waveguides. If a single vortex is imprinted in such waveguides, it can travel in a particular direction, showing one-way transportation. In other words, an imprinted vortex with a certain charge in a specifically designed higher-order dark state is only allowed to propagate unidirectionally.

19.
Gesundheitswesen ; 84(7): 566-574, 2022 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-35835094

RESUMO

The relevance of aerosols for the transmission of the Severe Acute Respiratory Syndrome Coronavirus Type 2 (SARS-CoV-2) is still debated. However, over time, in addition to distancing and hygiene rules, aerosol physics-based measures such as wearing face masks and ventilating indoor spaces were found to be efficient in reducing infections. In an interdisciplinary workshop "Aerosol & SARS-CoV-2" of the Association for Aerosol Research (GAeF) in cooperation with the German Society for Pneumology and Respiratory Medicine (DGP), the Professional Association of General Air Technology of the VDMA, the German Society for Virology (GfV), the Health Technology Society (GG) and the International Society for Aerosols in Medicine (ISAM) under the auspices of the Robert Koch Institute (RKI) in March 2021, the need for research and coordination on this topic was addressed. Fundamental findings from the various disciplines as well as interdisciplinary perspectives on aerosol transmission of SARS-CoV-2 and infection mitigation measures are summarized here. Finally, open research questions and needs are presented.


Assuntos
COVID-19 , Aerossóis , COVID-19/prevenção & controle , Alemanha , Humanos , Máscaras , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...