1.
Nanomedicine (Lond) ; 14(10): 1231-1246, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31124759

RESUMO

Aim: Nanomaterials and nanomedicinal products tend to interfere with various commonly used assays, including regulatory required endotoxin detection methods for medicines. We developed a method to quantify endotoxin levels that is compatible with nanomaterials and nanomedicinal products. Materials & methods: The method is based on measuring endotoxin indirectly via 3-hydroxylated fatty acids of lipid-A, using Ultra High Performance Liquid Chromatography coupled with mass spectrometry. The outcome was related to results of the commonly used Limulus Amebocyte Lysate method. Results: The ultra high performance liquid chromatography coupled with mass spectrometry method has clear advantages compared with other endotoxin determination assays; particularly the absence of nanospecific interference. Conclusion: The method is sensitive, straightforward and accurate in determining and quantifying endotoxin in nanomedicinal product samples.


Assuntos
Lipopolissacarídeos/análise , Nanoestruturas/química , Bioensaio , Cério/química , Cromatografia Líquida de Alta Pressão , Dendrímeros/química , Ácidos Graxos/análise , Compostos Férricos/química , Lipossomos/química , Proteínas de Membrana/química , Nanomedicina , Tamanho da Partícula , Espectrometria de Massas em Tandem , Titânio/química