Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 65(3): 345-9, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17098433

RESUMO

Cross-sections for the production of (181)Re, (182m)Re, (182g)Re, (183)Re, (184)Re, and (186)Re from proton bombardment of natural tungsten have been measured using the stacked foil technique for proton energies up to 17.6 MeV. Results are compared with the theoretical excitation functions as calculated by the EMPIRE II code (version 2.19) and experimental literature values. Results are in strong agreement with some of the previously reported literature as well at theoretical calculations for multiple reactions providing for more reliable estimates for the (186)W(p,n)(186)Re reaction.


Assuntos
Prótons , Radioisótopos , Rênio , Tungstênio/efeitos da radiação , Radioimunoterapia
2.
J Comput Assist Tomogr ; 20(3): 423-8, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8626905

RESUMO

PURPOSE: Our goal was to assess the utility of MR-PET image coregistration to quantify dopamine D2 receptors in striatum. METHOD: Twenty-nine normal subjects were investigated with PET and [11C]raclopride and with MRI. D2 receptors were quantified using the ratio of the distribution volume in striatum to that in cerebellum. Measures obtained using regions selected directly from the PET images were compared with those obtained from MR images and then projected to coregistered PET images. RESULTS: There were no differences between measures selected from the PET images (3.9 +/- 0.5) and those from the MR images (3.9 +/- 0.65). The values for these two measures were significantly correlated and corresponded to r = 0.9, p < 0.0001. CONCLUSION: Regions of interest selected directly from PET images, where there is a large contrast between the region of interest and background, as for the case of dopamine D2 ligands, are almost identical to those obtained from coregistered MR images.


Assuntos
Corpo Estriado/metabolismo , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Receptores de Dopamina D2/análise , Tomografia Computadorizada de Emissão , Adulto , Idoso , Idoso de 80 Anos ou mais , Corpo Estriado/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
3.
Synapse ; 18(2): 86-93, 1994 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-7839316

RESUMO

L-Deprenyl (Selegeline) is an enzyme-activated irreversible inhibitor of monoamine oxidase B (MAO B; EC 1.4.3.4). It is used to treat Parkinson's disease at a dose of 5 mg twice a day. Since enzyme inhibition is irreversible, the recovery of functional enzyme activity after withdrawal from L-deprenyl requires the synthesis of new enzyme. We have measured a 40 day half-time for brain MAO B synthesis in Parkinson's disease and in normal subjects after withdrawal from L-deprenyl. This is the first measurement of the synthesis rate of a specific protein in the living human brain. L-Deprenyl is currently used by 50,000 patients with Parkinson's disease in the United States and its use is expected to increase with reports that it may be beneficial in Alzheimer's disease. The slow turnover of brain MAO B suggests that the current clinical dose of L-deprenyl may be excessive and that the clinical efficacy of reduced dosing should be evaluated. Such an evaluation may have mechanistic importance as well as an impact on reducing the side effects and the costs arising from excessive drug use.


Assuntos
Encéfalo/enzimologia , Monoaminoxidase/biossíntese , Selegilina/efeitos adversos , Síndrome de Abstinência a Substâncias/enzimologia , Idoso , Encéfalo/efeitos dos fármacos , Feminino , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Doença de Parkinson/tratamento farmacológico , Selegilina/uso terapêutico , Tomografia Computadorizada de Emissão
4.
Int J Rad Appl Instrum A ; 43(6): 741-5, 1992 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-1319420

RESUMO

The effect of the foil material on the recovery of Xe-123 from the irradiation cell used for the measurement of the production of I-123 from the proton reaction on xenon-124 has been studied. The metal used for the foil can have a significant effect on the amount of Xe-123 which can be cryogenically pumped out of the irradiation cell at 30 min after the end of irradiation. Foils made from several metals and alloys were tested. Of these, the effect is most pronounced with "Havar" alloy foil where only 58% of the theoretically available activity was recovered. This effect should be considered and tested in the measurement of reaction cross-sections in irradiation cells and targets which have metal foils.


Assuntos
Radioisótopos do Iodo , Ligas , Metais , Medicina Nuclear , Isótopos de Xenônio
5.
Int J Rad Appl Instrum A ; 42(11): 1049-53, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1667311

RESUMO

An improved procedure for producing [18F]fluoromethane ([18F]FM) in batches of several hundred mCi is reported. 18F prepared by the 18O (p, n) 18F reaction in a H2(18)O target is trapped on a small column of Dowex 1 (x 10) resin to allow recovery of H2(18)O. One new feature is elution of 18F- from the column with 3 mL of CH3CN containing 67 microL 1.5 M aqueous (Bu)4N+ OH-, after residual H2(18)O has been removed with dry CH3CN. This 18F- solution reacts with CH3I in the presence of Ag2O directly to give [18F]FM, which is swept out of the reaction vessel with a stream of air, from which CH3I and other vapors are removed with a C18 SEP-PAK at room temperature. Another new technique is trapping of [18F]FM on a second SEP-PAK cooled in ethanol/dry ice. After warming the SEP-PAK to room temperature, the trapped [18F]FM can be recovered with either H2O or air. The improvements speed the preparation and minimize hands-on operations. The product has no detectable radiochemical impurities, and a specific activity of greater than 1 Ci/mumol. Non-radioactive CH3CN, CH3I and CH3OH are present at less than 0.2 mumol per batch.


Assuntos
Radioisótopos de Flúor/química , Hidrocarbonetos Fluorados/síntese química , Marcação por Isótopo/métodos , Cromatografia , Hidrocarbonetos Fluorados/isolamento & purificação , Cinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA