Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
J Endocrinol Invest ; 41(7): 831-837, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29288439

RESUMO

PURPOSE: Hyperhomocysteinemia is a known cardiovascular risk factor and a key player in the inflammatory activation of autoimmune diseases. Hashimoto's thyroiditis (HT) is the leading cause of hypothyroidism which, in itself, has been associated with a significant raise of homocysteine (Hcy) levels and increased cardiovascular risk. Our aim was to assess the impact of HT on Hcy levels in patients with acute hypothyroidism. METHODS: We prospectively enrolled 121 patients (mean age: 46 years, F/M = 102/19) with acute post-surgical hypothyroidism. Based on the presence of anti-thyroid antibodies and the histological description of an inflammatory infiltrate, 26 and 95 patients were classified as HT and non-HT, respectively. Several parameters including thyroid-stimulating hormone (TSH), levels of serum free T3 and free T4, weight, glucose levels, total cholesterol, creatinine, vitamin B12, ferritin and erythrocyte sedimentation rate were obtained from all patients and correlated with Hcy levels. RESULTS: Median Hcy level in the whole cohort was 16.8 µmol/L (normal values: < 12 µmol/l). Among all parameters analysed, only Hcy levels were significantly different between HT and non-HT patients (median Hcy = 19.7 vs 16.2 µmol/L, respectively; p = 0.018, Mann-Whitney U test). Analysis of covariance showed the presence of HT to be the strongest predictor of Hcy levels (coefficient = 0.25534, p = 0.001). Serum TSH was not significantly associated with Hcy levels (p = 0.943). CONCLUSION: In patients with iatrogenic hypothyroidism, those with HT have significantly higher Hcy levels than those without HT. The increase of Hcy levels appears to be mainly determined by the HT-related immune-inflammatory condition.


Assuntos
Autoimunidade , Hiper-Homocisteinemia/etiologia , Hipotireoidismo/complicações , Glândula Tireoide/imunologia , Doença Aguda , Adulto , Feminino , Doença de Hashimoto/complicações , Doença de Hashimoto/epidemiologia , Doença de Hashimoto/imunologia , Doença de Hashimoto/cirurgia , Humanos , Hiper-Homocisteinemia/epidemiologia , Hiper-Homocisteinemia/imunologia , Hipotireoidismo/epidemiologia , Hipotireoidismo/imunologia , Doença Iatrogênica/epidemiologia , Radioisótopos do Iodo/uso terapêutico , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Glândula Tireoide/efeitos da radiação
3.
Ann Oncol ; 23(2): 415-20, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21536660

RESUMO

BACKGROUND: A prospective, single-arm, open-label, multicenter, nonrandomised phase II trial to evaluate efficacy and safety of short fludarabine, mitoxantrone, and rituximab (FMR) induction followed by radioimmunotherapy, in untreated, intermediate/high-risk follicular non-Hodgkin's lymphoma (NHL) patients. PATIENTS AND METHODS: Fifty-five patients were treated using a sequential treatment schedule of four induction cycles of FMR chemoimmunotherapy, and a subsequent consolidating single administration of (90)Y-ibritumomab tiuxetan ((90)Y-IT), 8-14 weeks later. Patients were eligible for radioimmunotherapy if at least in partial response (PR) after induction, with normal platelet and granulocyte counts and a bone marrow infiltration ≤ 25%. Primary study end points were response rate and hematologic toxic effects; secondary end points were overall survival (OS) and progression-free survival (PFS). RESULTS: All the 55 patients received four induction cycles with an overall response rate of 96% (38 complete responses [CR] and 15 PR). Fifty-one patients (38 in CR and 13 in PR) received (90)Y-IT. By the end of the treatment, 49/55 patients achieved a CR. With a median follow-up of 21 months, the estimated 3-year PFS was 81% and the 3-year OS 100%. CONCLUSIONS: This study has established feasibility, tolerability, and efficacy of a regimen composed by short FMR induction with (90)Y-IT consolidation in untreated intermediate/high-risk follicular NHL patients.


Assuntos
Anticorpos Monoclonais/administração & dosagem , Protocolos de Quimioterapia Combinada Antineoplásica/administração & dosagem , Linfoma Folicular/tratamento farmacológico , Linfoma Folicular/radioterapia , Radioisótopos de Ítrio/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais Murinos/administração & dosagem , Feminino , Humanos , Quimioterapia de Indução , Masculino , Pessoa de Meia-Idade , Mitoxantrona/administração & dosagem , Estudos Prospectivos , Radioimunoterapia , Rituximab , Resultado do Tratamento , Vidarabina/administração & dosagem , Vidarabina/análogos & derivados
4.
Q J Nucl Med Mol Imaging ; 56(1): 90-8, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21068709

RESUMO

The aim of this study was to define, retrospectively, the utility to perform (99m)Tc-EDDA/HYNIC-Tyr3-octreotide ((99m)Tc-EDDA/HYNIC-TOC) scan in patients with NET. We studied 50 consecutive patients affected by different types of NET and divided in two groups. Group 1: 34 patients with known lesions in which (99m)Tc-EDDA/HYNIC-TOC was performed for staging, characterisation or to choose the appropriate treatment. Group 2: 16 patients suspected of having NET or in follow up after surgery. Patients were injected with 370 MBq of (99m)Tc-EDDA/HYNIC-Tyr3-octreotide and whole-body and SPET images acquired 2-3 hours after injection. Overall, 29 patients (58%) had a positive scan, with a sensitivity, specificity and accuracy of 70.3%, 76.9% and 72%, respectively (78.1%, 50% and 76.5%, in group 1 and 20%, 81.2%, 62.5% in group 2). In patients from group 1 (99m)Tc-HYNIC-TOC scintigraphy showed a concordance of 68% with another imaging procedure and in 9 patients revealed a greater number of lesions. In the second group, false negative results were especially found in patients with medullary thyroid cancer with negative radiological findings and elevated calcitonin. In conclusion, (99m)Tc-EDDA/HYNIC-TOC is highly indicated for in vivo histological characterization of known NET lesions, previously identified by other imaging modalities or biopsy, to plan appropriate therapy especially for patients with inoperable disease. In patients with only biochemical suspicion of NET and in those with negative markers, this scintigraphy does not significantly modify the clinical management.


Assuntos
Tumores Neuroendócrinos/diagnóstico por imagem , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Receptores de Somatostatina/análise , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tumores Neuroendócrinos/metabolismo , Sensibilidade e Especificidade
5.
Mol Imaging Biol ; 14(5): 637-46, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22127469

RESUMO

PURPOSE: The rationale of the present study was to radiolabel rituximab with 99m-technetium and to image B lymphocytes infiltration in the affected tissues of patients with chronic inflammatory autoimmune diseases, in particular, the candidates to be treated with unlabelled rituximab, in order to provide a rationale for 'evidence-based' therapy. PROCEDURES: Rituximab was labelled with (99m)Tc via 2-ME reduction method. In vitro quality controls of (99m)Tc-rituximab included stability assay, cysteine challenge, SDS-PAGE, immunoreactive fraction assay and competitive binding assay on CD20+ve Burkitt lymphoma-derived cells. For the human pilot study, 350-370 MBq (100 µg) of (99m)Tc-rituximab were injected in 20 patients with different chronic inflammatory autoimmune diseases. Whole body anteroposterior planar scintigraphic images were acquired 6 and 20 h p.i. RESULTS: Rituximab was labelled to a high labelling efficiency (>98%) and specific activity (3515-3700 MBq/mg) with retained biochemical integrity, stability and biological activity. Scintigraphy with (99m)Tc-rituximab in patients showed a rapid and persistent spleen uptake, and the kidney appeared to be a prominent source for the excretion of radioactivity. Inflamed joints showed a variable degree of uptake at 6 h p.i. in patients with rheumatoid arthritis indicating patient variability; similarly, the salivary and lacrimal glands showed variable uptake in patients with Sjögren's syndrome, Behçet's disease and sarcoidosis. Inflammatory disease with particular characteristics showed specific uptake in inflammatory lesions, such as, dermatopolymyositis patients showed moderate to high skin uptake, a sarcoidosis patient showed moderate lung uptake, a Behçet's disease patient showed high oral mucosa uptake and a polychondritis patient showed moderate uptake in neck cartilages. In one patient with systemic lupus erythematosus, we did not find any non-physiological uptake. CONCLUSION: Rituximab can be efficiently labelled with (99m)Tc with high labelling efficiency. The results suggest that this technique might be used to assess B lymphocyte infiltration in affected organs in patients with autoimmune diseases; this may provide a rationale for anti-CD20 therapies.


Assuntos
Anticorpos Monoclonais Murinos , Doenças Autoimunes/diagnóstico por imagem , Linfócitos B/diagnóstico por imagem , Linfócitos B/patologia , Diagnóstico por Imagem/métodos , Inflamação/diagnóstico por imagem , Marcação por Isótopo , Compostos de Organotecnécio , Anticorpos Monoclonais Murinos/sangue , Doenças Autoimunes/complicações , Doenças Autoimunes/patologia , Ligação Competitiva , Estabilidade de Medicamentos , Eletroforese em Gel de Poliacrilamida , Feminino , Humanos , Inflamação/complicações , Masculino , Pessoa de Meia-Idade , Compostos de Organotecnécio/sangue , Cintilografia , Rituximab
6.
Eur J Nucl Med Mol Imaging ; 37(2): 386-98, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19777175

RESUMO

The closing of the last century opened a wide variety of approaches for inflammation imaging and treatment of patients with rheumatoid arthritis (RA). The introduction of biological therapies for the management of RA started a revolution in the therapeutic armamentarium with the development of several novel monoclonal antibodies (mAbs), which can be murine, chimeric, humanised and fully human antibodies. Monoclonal antibodies specifically bind to their target, which could be adhesion molecules, activation markers, antigens or receptors, to interfere with specific inflammation pathways at the molecular level, leading to immune-modulation of the underlying pathogenic process. These new generation of mAbs can also be radiolabelled by using direct or indirect method, with a variety of nuclides, depending upon the specific diagnostic application. For studying rheumatoid arthritis patients, several monoclonal antibodies and their fragments, including anti-TNF-alpha, anti-CD20, anti-CD3, anti-CD4 and anti-E-selectin antibody, have been radiolabelled mainly with (99m)Tc or (111)In. Scintigraphy with these radiolabelled antibodies may offer an exciting possibility for the study of RA patients and holds two types of information: (1) it allows better staging of the disease and diagnosis of the state of activity by early detection of inflamed joints that might be difficult to assess; (2) it might provide a possibility to perform 'evidence-based biological therapy' of arthritis with a view to assessing whether an antibody will localise in an inflamed joint before using the same unlabelled antibody therapeutically. This might prove particularly important for the selection of patients to be treated since biological therapies can be associated with severe side-effects and are considerably expensive. This article reviews the use of radiolabelled mAbs in the study of RA with particular emphasis on the use of different radiolabelled monoclonal antibodies for therapy decision-making and follow-up.


Assuntos
Anticorpos Monoclonais , Artrite Reumatoide/diagnóstico por imagem , Técnicas de Sonda Molecular/tendências , Tomografia por Emissão de Pósitrons/tendências , Radioimunodetecção/tendências , Radioisótopos , Anticorpos Monoclonais/química , Artrite Reumatoide/radioterapia , Humanos , Marcação por Isótopo/tendências , Prognóstico , Radioisótopos/química , Radioisótopos/uso terapêutico , Compostos Radiofarmacêuticos/química , Compostos Radiofarmacêuticos/uso terapêutico
7.
Q J Nucl Med Mol Imaging ; 51(2): 204-10, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17420719

RESUMO

AIM: The aims of this study were: 1) to perform brain single photon emission computed tomography (SPECT) in anesthetized rats with high resolution cameras (HRC) equipped with parallel hole collimation resolution of about 1 mm (HRC1) and 2 mm (HRC2); 2) to assess when and with which radio-tracer HRC1 SPECT shows advantages over HRC2. METHODS: We used two multicrystal HRCs with parallel square hole collimators, whose pure tungsten septa closely fit the crystals, in turn matched with a 4 inch2 position sensitive photomultiplier. HRC1 showed 1.1 mm and HCR2 2.1 mm resolution at collimator contact. HRCs performed 180 degrees semi-circular orbits around the head of rats: image reconstruction occurred with ordered subsets expectation maximization algorithms. Resolution of SPECT was measured with a Derenzo Phantom, resulting 1.4 mm for HRC1 and 2.3 mm for HRC2. Three rats were studied with [(99m)Tc]HMPAO, 3 rats with [(99m)Tc]bombesin (BN) and 48 h later with [(123)I]ioflupane (DaTSCAN). SPECT studies were reviewed by two experienced operators. RESULTS: Technetium-99m-HMPAO SPECT showed similar images with HRC1 and HRC2. The uptake of BN by amygdale, hippocampus and olfactory tract was detected by both cameras. DaTSCAN SPECT with HRC1 showed detailed image of the tail of the caudatus: this image was not obtained with HRC2. DaTSCAN and BN SPECT showed amygdale with both HRCs. However, only the central nucleus of amygdale takes up DaTSCAN, whereas central, lateral and basolateral amygdaloid nuclei express BN receptors. Only HRC1 SPECT showed amygdale larger with BN than with DaTSCAN. CONCLUSION: Spatial resolution of 1.4 mm is appropriate to detect selected subcerebral structures.


Assuntos
Bombesina/análogos & derivados , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Nortropanos/farmacocinética , Compostos de Organotecnécio/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único/veterinária , Animais , Bombesina/farmacocinética , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/instrumentação , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos
8.
Q J Nucl Med Mol Imaging ; 51(4): 334-42, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17464276

RESUMO

AIM: Crohn's disease (CD) is a chronic inflammatory bowel disease characterized by a cellular-mediated immune response driven by cytokines secreted mainly by T helper 1 cells (Th1). In active phases of the disease, an increased production and release of tumor necrosis factor a (TNFalpha) by macrophages and monocytes of the lamina propria has been described. The aim of this study was to detect the presence of TNFalpha within the gut mucosa in patients with active CD by using (99m)Tc-labelled chimeric human/mouse monoclonal antibody anti-TNFalpha (Infliximab, Remicade). METHODS: Infliximab has been labeled with (99m)Tc after reduction of disulfide bound by 2-ME method. In vitro binding assay and biodistribution in animal of [(99m)Tc]Infliximab has been performed to evaluate the retention of its biological activity. Ten patients with active CD refractory to conventional medical therapies were studied. Images of the abdomen were acquired at 6 to 20 h after i.v. injection of about 10 mCi of [(99m)Tc]Infliximab and a week later, all patients were also studied with [(99m)Tc]HMPAO-labeled autologous white blood cells (WBC). RESULTS: A product with high labeling efficiency (>95%) and stability has been obtained. In vitro tests with stimulated T-cells expressing TNFalphalpha indicated that [(99m)Tc] Infliximab retains its binding activity to cell bound TNFalpha as compared to unlabelled Infliximab. The degree of [(99m)Tc]Infliximab uptake by the inflamed bowel evaluated at 20 h postinjection was much less than that seen with labeled WBC and with a different distribution. Three of these patients received anti-TNFalpha (Infliximab) for therapeutic purposes with good clinical results despite the scintigraphy with (99m)Tc-Infliximab was negative in 2 of them. CONCLUSION: Scintigraphy with [(99m)Tc]Infliximab shows the presence of little TNFalpha in the affected bowel of patients with active CD. Therefore, the clinical benefit that patients have from Infliximab therapy is unlikely the consequence of a local a reduction of TNFalpha and the mechanism of action of Infliximab, in therapeutic doses, deserves further investigations.


Assuntos
Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/uso terapêutico , Doença de Crohn/imunologia , Doença de Crohn/radioterapia , Tecnécio/imunologia , Tecnécio/uso terapêutico , Fator de Necrose Tumoral alfa/imunologia , Animais , Células Cultivadas , Humanos , Linfócitos/imunologia , Camundongos , Especificidade de Órgãos , Compostos Radiofarmacêuticos/farmacocinética , Distribuição Tecidual
9.
In Vivo ; 19(6): 1071-6, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16277024

RESUMO

In human blood, breakdown of gastrin-releasing peptide and other bombesin-related peptides occurs in less than 15 min. This quick enzymatic cleavage might impair the diagnostic use of labelled bombesin (BN). 99mTc-labelled bombesin (99mTc BN1) was injected intravenously and dynamic uptake data were acquired for diagnosing 26 cancers of different origin: 15 breast, 3 prostate, 5 colo-rectal, 1 pancreas, 2 small cell lung cancers and 1 gastrinoma. Background subtracted tumour uptake data were plotted against time and fitted with known mathematical functions. Twenty-three out of 26 cancers showed rapid increase of radioactivity followed by a radioactivity plateau, with some oscillations around the average plateau value. The time to 80% of max activity (T80) was the reference parameter to measure and to compare the uptake speeds. The slowest T80 was 7 min in one T1b breast cancer, gastrinoma reached T80 in 5 min and node-positive prostate cancers in 2 min. N+ breast cancers showed T80 at 3.62 +/- 0.75 min, N- breast cancers at 5.5 +/- 0.88 min (p < 0.02). When all the tumours were considered, N+ tumours showed T80 at 2.68 +/- 1.03 min and N- cancers at 5.5 +/- 0.82 min. In all the cancer types, the uptake of 99mTc BN was faster than 10 min. This result shows the ability of 99mTc BN to image tumours. The faster uptake by N+ versus N- cancers probably depends on the higher blood flow in N+ cancers.


Assuntos
Bombesina/análogos & derivados , Neoplasias/diagnóstico por imagem , Neoplasias/metabolismo , Compostos de Organotecnécio , Neoplasias da Mama/irrigação sanguínea , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/metabolismo , Carcinoma de Células Pequenas/irrigação sanguínea , Carcinoma de Células Pequenas/diagnóstico por imagem , Carcinoma de Células Pequenas/metabolismo , Neoplasias do Colo/irrigação sanguínea , Neoplasias do Colo/diagnóstico por imagem , Neoplasias do Colo/metabolismo , Feminino , Gastrinoma/irrigação sanguínea , Gastrinoma/diagnóstico por imagem , Gastrinoma/metabolismo , Humanos , Cinética , Neoplasias Pulmonares/irrigação sanguínea , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/metabolismo , Masculino , Estadiamento de Neoplasias , Neoplasias/irrigação sanguínea , Neoplasias Pancreáticas/irrigação sanguínea , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/metabolismo , Neoplasias da Próstata/irrigação sanguínea , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/metabolismo , Cintilografia , Compostos Radiofarmacêuticos , Receptores da Bombesina/metabolismo , Neoplasias Retais/irrigação sanguínea , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/metabolismo , Fluxo Sanguíneo Regional
11.
Anticancer Res ; 23(3A): 2139-42, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12894588

RESUMO

UNLABELLED: A pilot study has been carried out in order to verify the feasibility of scintigraphic driving for breast biopsy. A new high resolution (HR) gamma ray detector, the imaging probe (IP), and 99mTc [13Leu] Bombesin (99mTc BN), have been used to drive a mammotome biopsy needle after having fused radioisotope with digital X-ray images. IP is a mobile, high resolution, miniaturised gamma camera, whose field of view is one inch and whose spatial resolution is 2 mm. 99mTc BN is a new radiotracer derived from the well-known peptide, that has already shown very high sensitivity in detecting breast cancer. PATIENTS AND METHODS: Five patients very suspicious for breast cancer were studied. 185 MBq of 99mTc BN were i.v. injected and dynamic prone scintimammography was performed for 20 minutes with a conventional large field of view gamma camera. IP was matched with the biopsy system and digital X-ray device of a mammotome system, in order to fuse images and to use the mammotome pointer indifferently on X-ray, scintigraphic and fused images. Biopsy samples were counted and weighed: uptake was expressed as counts sec-1 gr-1. Samples were classified into high, intermediate and low uptake. Conventional histological assessment was blindly performed on the samples. RESULTS: All of the patients showed cancer. The T categorisation was T1a for two cancers and T1b for 3. Dynamic prone scintimammography with conventional gamma camera, as well as HR scintigraphy with IP showed spots of 99mTc BN uptake. Maximal mismatch between X-ray lesions and of hot spots imaged with IP before mammotome scintigraphy was 3.4 mm. All the high uptake samples and all but two of the intermediate uptake samples showed cancer, whereas histology found malignant tissue in only 2 out of the 8 low uptake samples. CONCLUSION: 99mTc BN confirms its high sensitivity in detecting breast cancer. IP is able to drive or co-drive breast biopsy when used with appropriate radiopharmaceuticals.


Assuntos
Biópsia/métodos , Bombesina , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Tecnécio , Idoso , Bombesina/análogos & derivados , Feminino , Câmaras gama , Humanos , Mamografia/métodos , Pessoa de Meia-Idade , Projetos Piloto , Cintilografia
12.
Appl Radiat Isot ; 58(4): 501-8, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12672631

RESUMO

The results of studies conducted with a small field of view tomographic gamma camera based on a Position Sensitive Photomultiplier Tube are reported. The system has been used for the evaluation of radiopharmaceuticals in small animals. Phantom studies have shown a spatial resolution of 2mm in planar and 2-3mm in tomographic imaging. Imaging studies in mice have been carried out both in 2D and 3D. Conventional radiopharmaceuticals have been used and the results have been compared with images from a clinically used system.


Assuntos
Bombesina/farmacocinética , Neoplasias Experimentais/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Tecnécio/farmacocinética , Algoritmos , Animais , Câmaras gama , Processamento de Imagem Assistida por Computador/instrumentação , Rim/diagnóstico por imagem , Camundongos , Camundongos Nus , Cintilografia , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador/instrumentação , Tecnécio/química
13.
Ann Oncol ; 14(4): 586-91, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12649106

RESUMO

BACKGROUND: In patients with digestive endocrine tumours, complete pre-operative staging is essential in planning proper management and evaluating treatment efficacy. To date, somatostatin receptor scintigraphy (SRS) is considered the 'gold standard' imaging procedure, and very few data are available concerning the use of helical computed tomography (hCT). This study aimed to determine the diagnostic accuracy and the ability to modify the surgical management of hCT, alone or combined with SRS. PATIENTS AND METHODS: Sixty patients were staged before surgery by hCT, SRS and tumour markers, and included in group 1 if suitable for radical surgery, otherwise in group 2. All patients underwent laparotomy followed by subsequent re-staging. RESULTS: SRS sensitivity was 77%, 48% and 67% for primary, lymph-node and liver lesions, respectively. hCT sensitivity was 94%, 69% and 94% for primary, lymph-node and liver lesions, respectively (P = 0.02 versus SRS, for liver lesions). During pre-operative evaluation, hCT correctly staged 92% and SRS 75% of patients (P = 0.02). hCT provided additional information in 17% of patients. CONCLUSIONS: Since hCT has been shown to be extremely accurate, providing essential information for the planning of surgical treatment compared with that of SRS, both techniques should be used in the pre-operative work-up of digestive endocrine tumours.


Assuntos
Neoplasias das Glândulas Endócrinas/diagnóstico por imagem , Neoplasias das Glândulas Endócrinas/patologia , Neoplasias Gastrointestinais/diagnóstico por imagem , Neoplasias Gastrointestinais/patologia , Estadiamento de Neoplasias/métodos , Receptores de Somatostatina/análise , Tomografia Computadorizada Espiral , Adolescente , Adulto , Idoso , Biomarcadores Tumorais/análise , Neoplasias das Glândulas Endócrinas/cirurgia , Feminino , Neoplasias Gastrointestinais/cirurgia , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Planejamento de Assistência ao Paciente , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Cintilografia/métodos , Sensibilidade e Especificidade
14.
Q J Nucl Med ; 47(4): 256-69, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14973418

RESUMO

Chronic inflammatory diseases usually lead to fibrosis of the target organ and consequent hypo function. They are often relapsing, invalidating and require life-long treatment. In this class of patients it is very important to try and achieve specific immune suppression to extinguish the immune process with the aim of preventing the disease, preventing or delaying complications and avoiding disease relapse, often requiring surgical intervention. It is important that, while attempting to improve the quality of life of these patients by means of anti-inflammatory drugs, side effects are reduced to a minimum via the use of specific immune therapies that block as selectively as possible the pathologic mechanism responsible for the disease. New therapeutic options are being developed for specific targeted therapies. Several trials are being performed to assess the efficacy and safety of this approach. All of them, however, rely on the clinical assessment of the patients to evaluate the effect of treatment. It would be important to use an objective and reliable method to highlight directly the immune process underlying the individual disease. This manuscript reviews the radiopharmaceuticals available or recently developed for imaging chronic inflammatory diseases and their use for therapy decision making and follow-up.


Assuntos
Anti-Inflamatórios/uso terapêutico , Citocinas , Inflamação/diagnóstico por imagem , Inflamação/tratamento farmacológico , Peptídeos , Radioimunodetecção/métodos , Compostos Radiofarmacêuticos , Animais , Doença Crônica , Humanos , Inflamação/fisiopatologia
15.
Tumori ; 88(3): S24-5, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12365376

RESUMO

AIMS: To assess the utility of 99mTc tetrofosmin (TF) scintigraphy as a diagnostic modality in lymphomas. METHODS: Seventeen patients (14 with Hodgkin's disease and three with non-Hodgkin's lymphomas; age range, 10-59 years) were investigated. Planar and SPECT images of the supradiaphragmatic region (including neck and chest) were obtained. All patients were untreated at the time of the first scintigraphy. Follow-up scans after therapy were acquired in six patients (in five twice), so a total of 28 scintigraphic studies were performed. Mediastinal, pulmonary, cervical, supraclavicular and axillary activity was evaluated and results were compared in a blinded fashion with those of CT. RESULTS: TF imaging demonstrated pathological focal uptake at 38 sites (16 in the mediastinum, eight in the lungs, four in the axillae, eight in the supraclavicular region and two in the cervical region) in 16 of 17 untreated patients. CT identified 24 lesions (16 in the mediastinum, two in the lungs, two in the axillae, two in the supraclavicular and two in the cervical region) in 17 patients. Scintigraphy detected 22 of the 24 lesions demonstrated by CT and revealed 16 unknown tumor sites in 10 patients. The only negative pre-treatment scintigraphy result was found in a patient with axillary lymph node involvement. On the first post-treatment scintigrams there was a reduction in the number of visualized pathological sites (seven vs 16) in five of the six patients examined. The second follow-up study demonstrated only two lesions in two of the five patients examined. CONCLUSIONS: Our preliminary results indicate that TF imaging is effective in depicting supradiaphragmatic lymphoma lesions in untreated patients and suggest that serial scintigraphic studies may be suitable for monitoring response to treatment. However, larger series are needed to better define the possible role of TF scintigraphy in the follow-up of the response to therapy.


Assuntos
Doença de Hodgkin/diagnóstico por imagem , Linfoma não Hodgkin/diagnóstico por imagem , Compostos Organofosforados , Compostos de Organotecnécio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
16.
Tumori ; 88(3): S28-30, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12365378

RESUMO

AIMS AND BACKGROUND: Bombesin-like neuropeptides work as neurotransmitters and growth factors at the same time. Several human cancers show overexpression of three receptors for mammalian counterparts of amphibia bombesins (ABNs), ie gastrin-releasing peptide (GRP), neuromedin B (NMB) and possibly another peptide. ABNs in turn are able to bind to mammalian and human receptors in vitro, and it is therefore interesting to study radioisotope-labeled bombesin (BN) and BN-like peptides as cancer seeking agents. METHODS AND STUDY DESIGN: Starting from the amino acid sequence of [Leu13] ABN, the Demokritos Institute has synthesized and labeled with technetium a new BN-like peptide that has the same biological characteristics as the amphibian peptide; changes were made only in the N-terminal part of the tetradecapeptide. After having obtained satisfactory results with 99mTc BN in a preclinical study, we started a phase I trial involving cancer patients as well as normal volunteers in Tomsk. Three normal volunteers, one patient with small cell lung cancer and one patient with primary prostate cancer were studied after iv injection of 185 MBq, corresponding to 0.7 micrograms of 99mTc BN. Dynamic images of the tumors were acquired for 20 mins, followed by SPET. Total body images were acquired in patients and normal volunteers 1 and 3 h after 99mTc BN acquisition. In addition, 99mTc sestamibi scintigraphy was performed in the patient with small cell lung carcinoma. RESULTS: No relevant side effects were observed. Both tumors were well visualized on early 1-2 mins images with planar as well as tomographic imaging. Total body images showed radioactivity in the liver, kidneys and thyroid gland. The stomach and spleen were ever imaged. Radioactivity was found in the urinary bladder 4 mins after injection in the patient with prostate cancer. Three-hour total body scans showed radioactivity in the duodenum. In the patient in whom also 99mTc sestamibi scintigraphy was performed, thyroid uptake was much higher with sestamibi than with 99mTc BN, whereas the uptake of small cell lung carcinoma was higher with 99mTc BN than with sestamibi. CONCLUSIONS: 99mTc BN is able to clearly image tumors with BN receptor overexpression. Our first impression is that in the future this radiopharmaceutical may serve as a cancer seeking agent and, due to its high tumoral uptake, also as a radiotracer for radioisotope-guided surgery.


Assuntos
Bombesina/metabolismo , Neoplasias/diagnóstico por imagem , Neoplasias/metabolismo , Receptores da Bombesina/metabolismo , Compostos de Tecnécio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Carcinoma de Células Pequenas/diagnóstico por imagem , Carcinoma de Células Pequenas/metabolismo , Humanos , Leucina , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/metabolismo , Masculino , Neoplasias/cirurgia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/metabolismo , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi
17.
Tumori ; 88(3): S25-8, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12365377

RESUMO

BACKGROUND: Several tumors including lung, prostate, ovarian, colon, and exocrine pancreatic cancer show receptors for the amphibian neurotransmitter and growth factor bombesin (BN) and its mammalian counterparts gastrin-releasing peptide and neuromedin B. Also breast cancer has been reported to show such receptors: the presence of BN receptors in primary breast cancer has been demonstrated on cultured cells and by autoradiography on breast tissue samples. Authors who have studied BN receptors in breast cancer do not agree on their frequency in primary cancer, but indicate that 100% of metastatic breast cancers show such receptors. METHODS: We examined three primary breast cancer patients with 99mTc BN and 99mTc sestamibi one week before surgery. One of them showed axillary node invasion. The same acquisition technique was used for breast and chest imaging with both radiopharmaceuticals, whereas total body images were acquired only with 99mTc BN. Also the administered radioactivity was different: 20 mCi of 99mTc sestamibi and 5-8 mCi of 99mTc BN. Dynamic images were acquired for 20 mins after iv injection with the patient in ventral decubitus and the gamma camera positioned in a lateral view, as is generally done in Khakhali's prone scintimammography. Anterior chest images were acquired for 30 mins. Prone scintimammography was performed one hour after administration of both tracers. ROIs were drawn on tumors and surrounding breast with the same technique in order to calculate the tumor to breast ratio (T/B). In addition, total body scan was performed one hour and three hours after 99mTc BN administration. All three patients underwent breast conserving surgery with lymphadenectomy. Postoperative pathologic assessment showed the following T and N stages in the three patients: T1bN0, T1c-N0, and T1cN1. RESULTS: All three cancers were imaged with both tracers. The T/B of 99mTc BN was always higher than that of 99mTc sestamibi. Chest uptake was always much higher with 99mTc sestamibi than with 99mTc BN. Comparison between 99mTc BN and 99mTc sestamibi images gave other intriguing results: in the N1 patient both tracers clearly imaged the invaded node, but on the 99mTc BM image the primary tumor was larger than on the 99mTc sestamibi image and the node was smaller. It is known that 99mTc BN is not taken up by vessels and inflammatory tissue. The time activity curves of the two tracers were significantly different in all patients, with an increase in 99mTc BN uptake in the first three to five minutes, followed by a less sharp uprise of the curve, quite similar to a plateau. CONCLUSIONS: Our first impression is that 99mTc BN is a useful breast cancer seeking agent and very promising for lymph node staging.


Assuntos
Bombesina/metabolismo , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/metabolismo , Receptores da Bombesina/metabolismo , Idoso , Feminino , Regulação Neoplásica da Expressão Gênica , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Cintilografia , Compostos Radiofarmacêuticos , Compostos de Tecnécio , Tecnécio Tc 99m Sestamibi , Regulação para Cima
18.
Tumori ; 88(3): S35-7, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12365382

RESUMO

AIMS: Portable cameras allow easy transfer of the detector, and thus of radioisotope imaging, to the operating room. In this paper we describe our preliminary experience in radionuclide imaging of breast cancer with a 22.8 x 22.8 mm(2) field-of-view minicamera called "Imaging Probe" (IP). METHODS: Breast cancer detection by IP was performed to guide biopsy, in particular open biopsy, or help fine-needle or core-needle positioning when the main guidance method was ultrasonography or digital radiography. 99mTc Sestamibi (MIBI) was injected 1 h before imaging and biopsy to 14 patients with suspected or known breast cancer. Scintigraphic images were acquired before and after biopsy in each patient. The surgeon was allowed to take into account scintigraphic images as well as previously performed mammograms and ultrasonography. RESULTS: High-resolution IP images were able to guide biopsy toward cancer or toward washout zones of cancer which are thought to be chemoresistant in seven patients out of 10. Four patients in whom IP and MIBI were unable to guide biopsy were found not to have cancer. CONCLUSIONS: Our study confirms the ability of IP to guide breast biopsy even when our minicamera has to be handled manually by trained physicians during surgery.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Biópsia de Linfonodo Sentinela/instrumentação , Feminino , Humanos , Metástase Linfática , Cintilografia , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi
19.
Tumori ; 88(3): S37-9, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12365383

RESUMO

AIMS AND BACKGROUND: The "Imaging Probe" (IP) is a small, portable, high-resolution gamma camera to be used in radioguided surgery. The present work discusses a special prototype designed for guiding biopsies. The IP was mounted to a Fischer digital X-ray stereotactic core biopsy system in such a way that biopsy could be guided simultaneously by X-ray stereotaxis and 99mTc-Sestamibi (MIBI) images from IP. METHODS: The IP field of view was 22.8 x 22.8 mm(2), with a spatial resolution of approx. 2.5 mm. We used off-line software for image fusion on a dedicated Pentium III portable PC. It was matched with a Fischer digital X-ray stereotactic biopsy system dedicated to direct the mammotome towards breast opacities. The operator was allowed to slightly correct the direction of the mammotome needle taking into account stereotactic X-ray, scintigraphic and fused images. Biopsy samples were counted by IP before they were sent to the pathologist. RESULTS: High-resolution IP scintigraphy showed substantial, though not exact, matching between MIBI hot spots and X-ray opacities. More than one hot spot was detected even in the smallest (0.6 cm) lesion. Post-biopsy scintigraphy showed absence of significant hot spots in two patients, whereas in the third patient one of the three hot spots was still partially present. All lesions showed cancer on histological examination. CONCLUSIONS: Measurement of radioactivity in biopsy specimens confirmed the heterogeneous distribution of radioactivity within cancers that IP had detected before biopsy.


Assuntos
Biópsia por Agulha/métodos , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Feminino , Humanos , Valor Preditivo dos Testes , Radiografia , Cintilografia , Compostos Radiofarmacêuticos , Técnicas Estereotáxicas , Tecnécio Tc 99m Sestamibi
20.
Tumori ; 88(3): S30-2, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12365380

RESUMO

AIMS AND BACKGROUND: When removal of osteoid osteoma is performed with open biopsy, the surgeon can be guided by radioactivity of 99mTc-MDP (methylene D- phosphonate) acquired by a probe. MATERIAL AND METHODS: We compared the performance of a commercially available ZnCdTe probe (Neoprobe 2000) and a one-square-inch-field-of-view imaging probe (IP) on two patients undergoing open biopsy for osteoid osteoma. Triphasic bone scintigraphy was performed before operation and Neoprobe as well as IP were used in the operating room by two nuclear physicians. When the surgeon asked for guidance, each nuclear physician had to indicate a precise direction. RESULTS: The surgeon asked for guidance once in the first operation, on a patient with osteoid osteoma of the femur, and four times in the second operation, for osteoid osteoma of the acetabulum. The indications provided by IP were correct 5/5 times, whereas the commercial probe was correct 3/5 times. Both devices were able to assess the surgical radicality. After biopsy, bone samples were divided into high-count and low-count samples. Pathological examination confirmed the presence of osteoid osteoma in high-count samples. CONCLUSIONS: IP has already been used to guide biopsy, but only in breast disease. The present work confirmed its good performance also in orthopedics as a portable mini gamma camera that can be used in the operating room.


Assuntos
Biópsia/métodos , Neoplasias Ósseas/diagnóstico por imagem , Osteoma/diagnóstico por imagem , Medronato de Tecnécio Tc 99m/análogos & derivados , Humanos , Imageamento por Ressonância Magnética , Valor Preditivo dos Testes , Cintilografia , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA