Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
1.
Int J Cardiol ; 405: 131939, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38458388

RESUMO

BACKGROUND: Advances in imaging have led to procedural optimization of left atrial appendage closure (LAAC). Contrast-free approaches, guided merely by echocardiography, have been established, however data on this topic remains scarce. In this analysis, we assessed contrast-free procedural results with the LAMBRE LAAC device. METHODS: The multicenter retrospective BoBoMa (Bonn/Bordeaux/Mainz)-Registry included a total of 118 patients that underwent LAAC with LAMBRE devices omitting contrast-dye. Baseline and echocardiographic characteristics as well as intra- and postprocedural complications and outcomes were assessed. RESULTS: Patients were at a mean age of 77.5 ± 7.5 years with high thromboembolic and bleeding risk (CHADS-VASc-score 4.6 ± 1.4, HAS-BLED-score 3.7 ± 1.0, respectively). Renal function was impaired with a mean glomerular filtration rate (GFR) of 50 ± 22 ml/min. Mean procedural time was 47.2 ± 37.5  minutes with a mean radiation dose of 4.75 ± 5.25 Gy*cm2. Device success, defined as proper deployment in a correct position, was achieved in 97.5% (115/118) of cases with repositioning of the occluder in 7.6% (9/118) and resizing in 3.4% (4/118) of cases. No relevant peri-device leakage (>3 mm) was observed with 42% of occluders being implanted in an ostial position. Periprocedural complications occurred in 6.8% (8/118) of cases, including two cases of device embolization and one case of clinically-relevant pericardial effusion requiring surgical intervention. Other complications included pericardial effusion (2.5%, 3/118) and vascular access site complications (1.7%, 2/118). CONCLUSION: Echocardiography-guided contrast-free LAAC using the LAMBRE device is safe and feasible. Further prospective studies including the direct comparison of devices as well as imaging techniques are warranted in contrast-free LAAC.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Humanos , Apêndice Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Masculino , Feminino , Idoso , Estudos Retrospectivos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Idoso de 80 Anos ou mais , Sistema de Registros , Resultado do Tratamento , Ecocardiografia Transesofagiana/métodos , Meios de Contraste/administração & dosagem , Seguimentos
2.
Clin Res Cardiol ; 113(1): 107-115, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37524838

RESUMO

BACKGROUND: Many patients in need for transcatheter aortic valve implantation (TAVI) present with an aortic annulus size larger than recommended by the manufacturer's instructions for use (IFU). AIMS: To investigate procedural and short-term safety and efficacy of TAVI in patients with extra-large annuli (ELA). METHODS: 30-day clinical outcome and valve performance as defined by VARC 3 of 144 patients with an aortic annulus size exceeding the permitted range were compared to a propensity-score matched control cohort of patients with an aortic annulus size consistent with the IFU. RESULTS: Area and perimeter was 730.4 ± 53.9 mm2 and 96.7 ± 6.5 mm in the ELA group. Technical (96.5% vs. 94.4%) and device success (82.3% vs. 84.5%) were comparable in patients with ELA (annulus area 730.4 ± 53.9 mm2) and matched controls (annulus area 586.0 ± 48.2 mm2). There was no significant difference in 30-day mortality rate, major intraprocedural complications, type 3 or 4 bleedings, major vascular complications, or stroke. Moderate paravalvular leakage (PVL) occurred more frequent in the ELA group (8.9% vs 2.2%; p = 0.02). The rate of new pacemaker implantation was 7.0% in the ELA cohort and 15.0% in the control cohort, respectively (p = 0.05). CONCLUSION: Treatment of ELA patients with third-generation TAVI prostheses is feasible and safe, providing similar device success and complication rates as in matched controls with regular-sized aortic annulus. Post-interventional pacemaker implantation rates were low compared to the control group, yet incidence of moderate PVL remains problematic in ELA patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Desenho de Prótese , Resultado do Tratamento
3.
Echocardiography ; 40(11): 1227-1236, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37788148

RESUMO

OBJECTIVE: To evaluate the role of the CT-derived angle between the intra-atrial septum (IAS) and the left atrial appendage (LAA) on procedural complexity and clinical outcomes in left atrial appendage occlusion (LAAO) procedures. BACKGROUND: Given the broad variations in anatomy, LAAO remains one of the most challenging interventional procedures in structural heart disease. In recent years, preprocedural cardiac tomography (CT) has evolved as a valuable tool; however, prediction of procedural complexity remains cumbersome. METHODS: We retrospectively analyzed 47 patients that underwent LAAO at our center in whom pre-procedural cardiac CT-scans were available. Among other baseline parameters, we measured the angle between the LAA ostium and the preferred transseptal puncture site at the IAS. We compared patients with an angle above and below the median regarding procedural characteristics and procedural outcome. RESULTS: The median angle between the LAA and the IAS was 127.3° (IQR: 120.9-141.3). LAAO took longer in patients with a measured angle below the median (55.0 ± 22.7 min vs. 41.3 ± 17.5 min; p = .04), resulting in longer radiation times (13.0 ± 5.3 min vs. 9.8 ± 5.7 min; p = .04) and more contrast use (61.1 ± 47.5 mL vs. 33.6 ± 24.7 mL; p = .05). Moreover, the necessity for a sheath exchange was significantly higher (30.4% vs. 4.2%, p = .02) and device repositioning or device resizing trended to be more frequent (26.1% vs. 8.3%; p = .1 and 21.7% vs. 8.3%; p = .2). There were no differences in procedural outcome, device-position and peri-device leak (PDL). CONCLUSIONS: The angle between the transseptal puncture site and the LAA ostium may serve as a predictor for more demanding LAAO interventions. In our study a steeper angle led to a prolonged procedure resulting in higher doses of contrast and radiation, but was not associated with a worse procedural outcome.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Resultado do Tratamento , Ecocardiografia Transesofagiana/métodos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Estudos Retrospectivos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Tomografia , Tomografia Computadorizada por Raios X
4.
Sci Rep ; 13(1): 14181, 2023 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-37648792

RESUMO

Cerebral embolization is a known complication of transcatheter aortic valve implantation (TAVI) but the effect of the procedure on the ocular perfusion is currently unclear. Thus, we investigated post-procedural morphologic and perfusion changes of the retina and choroid, using optical coherence tomography angiography (OCTA) and color fundus photography (CFP) in a prospective cohort study. Ophthalmic examinations were conducted pre- and post-TAVI. OCTA images were analyzed quantitatively based on vessel density and skeleton density of the superficial and deep retinal plexus as well as the signal intensity and flow deficits in the choriocapillaris. CFP images were assessed for presence of acute retinal ischemia, optic nerve swelling, vessel emboli, hemorrhages and cotton wool spots. Data was analyzed using linear mixed models. Twenty patients (9 women; 11 men) at a mean age of 81 ± 6 years were included. Pre- and post-interventional ocular imaging data were available for 32 eyes. The analysis revealed a significant impairment of the choriocapillaris perfusion after TAVI with an increased proportion of flow deficits (p = 0.044). When controlling for blood pressure, the average size of choriocapillaris flow voids was significantly increased (systolic and diastolic, p = 0.039 and 0.029). Qualitatively, focal areas of retinal ischemia were detected on OCTA in 33% of participants. Silent emboli or cotton wool spots were identified on CFP in 21%. Our findings indicate a reduced choroidal perfusion as well as areas of retinal ischemia and embolization in a considerable proportion of patients following TAVI. Pending confirmation in a larger sample, these complications merit monitoring as well as inclusion in consent procedures for TAVI.


Assuntos
Papiledema , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Face , Retina , Isquemia
5.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial
6.
Clin Res Cardiol ; 112(12): 1790-1799, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37294311

RESUMO

BACKGROUND: Device-related thrombus (DRT) after left atrial appendage closure (LAAC) is associated with adverse outcomes, i.e. ischemic stroke or systemic embolism (SE). Data on predictors of stroke/SE in the context of DRT are limited. AIMS: This study aimed to identify predisposing factors for stroke/SE in DRT patients. In addition, the temporal connection of stroke/SE to DRT diagnosis was analyzed. METHODS: The EUROC-DRT registry included 176 patients, in whom DRT after LAAC were diagnosed. Patients with symptomatic DRT, defined as stroke/SE in the context of DRT diagnosis, were compared against patients with non-symptomatic DRT. Baseline characteristics, anti-thrombotic regimens, device position, and timing of stroke/SE were compared. RESULTS: Stroke/SE occurred in 25/176 (14.2%) patients diagnosed with DRT (symptomatic DRT). Stroke/SE occurred after a median of 198 days (IQR 37-558) after LAAC. In 45.8% stroke/SE occurred within one month before/after DRT diagnosis (DRT-related stroke). Patients with symptomatic DRT had lower left ventricular ejection fractions (50.0 ± 9.1% vs. 54.2 ± 11.0%, p = 0.03) and higher rates of non-paroxysmal atrial fibrillation (84.0% vs. 64.9%, p = 0.06). Other baseline parameters and device positions were not different. Most ischemic events occurred among patients with single antiplatelet therapy (50%), however, stroke/SE was also observed under dual antiplatelet therapy (25%) or oral anticoagulation (20%). CONCLUSION: Stroke/SE are documented in 14.2% and occur both in close temporal relation to the DRT finding and chronologically independently therefrom. Identification of risk factors remains cumbersome, putting all DRT patients at substantial risk for stroke/SE. Further studies are necessary to minimize the risk of DRT and ischemic events.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Trombose , Humanos , Resultado do Tratamento , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Trombose/diagnóstico , Trombose/epidemiologia , Trombose/etiologia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Sistema de Registros , Apêndice Atrial/diagnóstico por imagem
7.
Eur Heart J Digit Health ; 4(3): 207-215, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37265862

RESUMO

Aims: Coronary artery disease (CAD) remains the leading cause of death worldwide. 'Stable' CAD is a chronic progressive condition, which recent European guidelines recommend referring to as 'chronic coronary syndrome' (CCS). Despite therapeutic advances, morbidity and mortality among patients with CCS remain high. Optimal secondary prevention in patients with CCS includes optimization of modifiable risk factors with behavioural changes and pharmacological therapy. The CHANGE study aims to provide evidence for optimization of secondary prevention in CCS patients by using a smartphone application (app). Methods and results: The CHANGE study is designed as a prospective, randomized, controlled trial with a 1:1 allocation ratio, which is currently performed in nine centres in Germany in a parallel group design. 210 patients with CCS will be randomly allocated either to the control group (standard-of-care) or to the intervention group, who will be provided the VantisTherapy* app in addition to standard-of-care to incorporate secondary prevention into their daily life. The study will be performed in an open design. Outcomes will be assessed using objective data from three in-person visits (0, 12, and 24 weeks). Primary outcomes will involve adherence to secondary prevention recommendations and quality of life (QoL). The recruitment process started in July 2022. Conclusion: The CHANGE study will investigate whether a smartphone-guided secondary prevention app, combined with a monitor function compared with standard-of-care, has beneficial effects on overall adherence to secondary prevention guidelines and QoL in patients with CCS. Trial registration: The study is listed at the German study registry (DRKS) under the registered number DRKS00028081.

8.
Clin Res Cardiol ; 2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37291248

RESUMO

BACKGROUND: Device-related thrombus (DRT) after left atrial appendage occlusion (LAAO) is potentially linked to adverse events. Although clinical reports suggest an effect of the device type and position on the DRT risk, in-depth studies of its mechanistic basis are needed. This in silico study aimed to assess the impact of the position of non-pacifier (Watchman) and pacifier (Amulet) LAAO devices on surrogate markers of DRT risk. METHODS: The LAAO devices were modeled with precise geometry and virtually implanted in different positions into a patient-specific left atrium. Using computational fluid dynamics, the following values were quantified: residual blood, wall shear stress (WSS) and endothelial cell activation potential (ECAP). RESULTS: In comparison to an ostium-fitted device position, deep implantation led to more residual blood, lower average WSS and higher ECAP surrounding the device, especially on the device's atrial surface and the surrounding tissue, suggesting increased risk for potential thrombus. For the non-pacifier device, an off-axis device orientation resulted in even more residual blood, higher ECAP and similar average WSS as compared to an ostium-fitted device position. Overall, the pacifier device showed less residual blood, higher average WSS and lower ECAP, compared to the non-pacifier device. CONCLUSIONS: In this in silico study, both LAAO device type and implant position showed an impact on potential markers of DRT in terms of blood stasis, platelet adhesion and endothelial dysfunction. Our results present a mechanistic basis for clinically observed risk factors of DRT and the proposed in silico model may aid in the optimization of device development and procedural aspects.

9.
Int J Cardiol Heart Vasc ; 46: 101205, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37122629

RESUMO

Background: Vascular injury and bleeding complications remain frequent after transcatheter aortic valve replacement (TAVR). Whether the access-site of preprocedural coronary angiography (CAG) affects TAVR-related complications is not known. The aim of this study was to evaluate the impact of transradial (TRA) versus transfemoral access (TFA) for preprocedural CAG on outcomes in patients undergoing subsequent TAVR. Methods: The study cohort included 1002 patients undergoing transfemoral TAVR, of whom 39.4% (395/1002) had undergone radial and 60.6% (607/1002) femoral access for pre-TAVR CAG. The primary endpoint was a composite of 30-day mortality and major vascular complications after TAVR. Key secondary endpoints included VARC-3-defined complications. Results: The primary endpoint occurred less frequently in patients with prior TRA (3.3%) as compared to patients with prior TFA (6.3%, p = 0.04), which was mainly driven by significantly lower rates of major vascular complications (0.8% vs 2.5%, p = 0.05). Moreover, incidences of periprocedural access-related vascular injury and unplanned endovascular interventions were lower in TRA patients (13.2% vs 18.0%, p = 0.05). The rate of major bleeding tended to be lower in the TRA (1.5%) as compared to the TFA group (3.5%) but was not significantly different (p = 0.07). Moreover, the rate of life-threatening bleeding was comparable between both groups (0.5% vs 0.8%, p = 0.71). Conclusion: Transradial access for preprocedural CAG was associated with significantly lower rates of vascular complications following subsequent TAVR as compared to transfemoral access. However, despite the tendency to lower major bleedings with transradial access, no significant association was detectable between the access-site of coronary angiography and TAVR-related bleeding complications.

10.
Hellenic J Cardiol ; 74: 1-7, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37119968

RESUMO

OBJECTIVES: Left ventricular reverse remodeling (LVRR) is associated with improved outcome in patients with heart failure. Factors associated with and predictive of LVRR in patients with low-flow low-gradient aortic stenosis (LFLG AS) after transcatheter aortic valve implantation (TAVI) and its impact on outcome were assessed. METHODS: Pre- and postprocedural left ventricular (LV) function and volume were investigated in 219 patients with LFLG. LVRR was defined as an absolute increase of ≥10% in LV ejection fraction (LVEF) and reduction of ≥15% in LV end-systolic volume (LVESV). The primary endpoint was the combination of all-cause mortality and rehospitalization for heart failure. RESULTS: The mean LVEF was 35.0 ± 10.0%, with a stroke volume index (SVI) of 25.9 ± 6.0 mL/m2 and LVESV of 94.04 ± 46.0 mL. At a median of 5.2 months (interquartile range, 2.7-8.1 months), 77.2% (n = 169) of the patients showed echocardiographic evidence of LVRR. A multivariate model revealed three independent factors for LVRR after TAVI: SVI of <25 mL/m2 (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.08-3.58; p < 0.01), LVEF of <30% (HR, 2.76; 95% CI, 1.53-2.91; p < 0.01), and valvulo-arterial impedance (Zva) of <5 mmHg/mL/m2 (HR, 5.36; 95% CI, 1.80-15.98; p < 0.01). Patients without evidence of LVRR showed a significantly higher incidence of the 1-year combined endpoint (32 [64.0%] vs. 75 [44.4%], p < 0.01). CONCLUSIONS: The majority of patients with LFLG AS show LVRR after TAVI, which is associated with favorable outcomes. An SVI of <25 mL/m2, LVEF of <30%, and Zva < 5mmHg/mL/m2 represent predictors of LVRR.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Função Ventricular Esquerda , Volume Sistólico , Insuficiência Cardíaca/complicações , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Remodelação Ventricular , Índice de Gravidade de Doença
11.
Circ Cardiovasc Interv ; 16(1): e012538, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36649387

RESUMO

BACKGROUND: In recent years, transcatheter aortic valve replacement (TAVR) techniques and technology have continuously improved. Data regarding the impact of these advancements on outcomes in large real-world settings are still limited. The aim of this study was to investigate temporal trends and assess contemporary outcomes after TAVR with Evolut PRO/PRO+ supra-annular self-expanding valves. METHODS: This study included patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries who underwent transfemoral TAVR with Evolut PRO/PRO+. Procedural dates (August 2017 through November 2021) were stratified in quartiles (Q) and used to investigate temporal trends in TAVR outcomes. Predischarge, 30-day Valve Academic Research Consortium-3 defined, and 1-year outcomes were evaluated. RESULTS: In total, 1616 patients from 28 centers were included. Over time, patients had lower Society of Thoracic Surgeon-Predicted Risk of Mortality score (Q1-4, 4.1% [2.8-6.3%], 3.7% [2.6-5.3%], 3.3% [2.4-4.9%], 2.9% [2.2-4.3%]; P<0.001) and more moderate or heavy valve calcification (Q1-4, 80%, 80%, 82%, 88%; P=0.038). Overall Valve Academic Research Consortium-3 technical success was 94.1%, with 30-day and 1-year all-cause mortality of 2.4% and 10%, respectively. Throughout the study period, procedures were associated with higher rates of 30-day device success (Q1-4, 81.2%, 82.2%, 82.0%, 88.0%; Cochran-Armitage P=0.023) and early safety (Q1-4, 66.8%, 67.5%, 74.0%, 77.6%; Cochran-Armitage P<0.001), with fewer permanent pacemaker implantations (Q1-4: 15.3%, 20.0%, 12.1%, 11.6%; Cochran-Armitage P=0.023) and residual mild or greater paravalvular leaks (Q1-4, 50.4%, 42.1%, 36.5%, 35.8%; Cochran-Armitage P<0.001). CONCLUSIONS: TAVR with Evolut PRO/PRO+ self-expanding valve is safe and effective. Despite the treatment of heavier calcified anatomies, procedural outcomes are improving over time with less need for pacemaker implantation and less significant paravalvular leaks.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Tempo , Resultado do Tratamento , Sistema de Registros , Desenho de Prótese , Fatores de Risco
12.
Hellenic J Cardiol ; 70: 1-9, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36538975

RESUMO

OBJECTIVE: Several supra-annular self-expanding transcatheter systems are commercially available for transcatheter aortic valve implantation (TAVI). Comparative data in large-scale multicenter studies are scant. METHODS: This study included a total of 5175 patients with severe aortic stenosis undergoing TAVI with the ACURATE neo (n = 1095), Evolut R (n = 3365), or Evolut PRO (n = 715) by a transfemoral approach at five high-volume centers. Propensity score matching resulted in 654 triplets. Outcomes are reported according to the Valve Academic Research Consortium-3 (VARC-3) consensus. RESULTS: Moderate or severe paravalvular regurgitation (PVR) occurred significantly more often in the ACURATE neo group (5.2%) than in the Evolut R (1.8%) and Evolut PRO (3.3%) groups (p = 0.003). The rates of major vascular-/access-related complications (4.6%, 3.8%, and 5.0%; p = 0.56), type 3 or 4 bleeding (3.2%, 2.1%, and 4.1%; p = 0.12), and 30-day mortality (2.4%, 2.6%, and 3.7%; p = 0.40) were comparable. The rate of new permanent pacemaker implantation (PPI) was significantly lower in the ACURATE neo group (9.5%, 17.6%, and 16.8%; p < 0.001). Independent predictors for 2-year survival were a Society of Thoracic Surgeons (STS) risk score ≥5%, diabetes mellitus, a glomerular filtration rate <30 ml/min, baseline mean transvalvular gradient ≤ 30 mm Hg, treating center, and relevant PVR. CONCLUSION: In this multicenter study, TAVI with the ACURATE neo, Evolut R, or Evolut PRO was feasible and safe. The rate of relevant PVR was more frequent after the ACURATE neo implantation, with, however, lower rates of PPI. Two-year survival was mainly driven by baseline comorbidities.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Pontuação de Propensão , Desenho de Prótese , Resultado do Tratamento
13.
Heart Vessels ; 38(2): 274-283, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36251050

RESUMO

In this prospective observational study, we investigated the impact of geriatric syndromes and frailty on mortality and evaluated the prognostic value of different frailty, nutritional, and geriatric assessment tools in high-risk patients with severe mitral valve regurgitation (MR) who were evaluated for mitral valve therapies including surgical, interventional, and conservative treatment options. We prospectively assessed multiple parameters including the CONUT Score, the Katz Index of independence in activities of daily living (ADL), the Fried Frailty Phenotype (FFP), and the Essential Frailty Toolset (EFT) Score in 127 patients with severe symptomatic MR requiring surgical/interventional treatment versus conservative monitoring. We compared their predictive value on mortality including multivariate regression analysis to identify the most suitable tool to predict outcomes in these patient groups. The frailty syndrome as assessed with the CONUT Score, Katz Index, EFT Score, and FFP was associated with higher rates of comorbidities, significantly higher risk scores such as logistic EuroSCORE, EuroSCORE II, and STS-PROM, and significantly higher mortality rates. The EFT Score and FFP were independent predictors of one-year all-cause mortality in our study cohort (EFT Score: HR 1.9, 95% CI 1.2 to 3.2; p = 0.01; FFP: HR 1.8, 95% CI 1.1 to 3.1; p = 0.015). Geriatric syndromes and frailty are associated with increased mortality in high-risk patients with symptomatic severe MR. The EFT Score and the FFP were independent predictors of one-year all-cause mortality.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Insuficiência da Valva Mitral , Humanos , Idoso , Fragilidade/complicações , Fragilidade/diagnóstico , Idoso Fragilizado , Atividades Cotidianas , Insuficiência da Valva Mitral/cirurgia , Síndrome , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Avaliação Geriátrica
14.
Clin Cardiol ; 46(1): 67-75, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36259730

RESUMO

BACKGROUND: Despite major advances, transcatheter aortic valve replacement (TAVR) is still associated with procedure-specific complications. Although previous studies reported lower bleeding rates in patients receiving protamine for heparin reversal, the optimal protamine-to-heparin dosing ratio is unknown. HYPOTHESIS: The aim of this study was a comparison of two different heparin antagonization regimens for the prevention of bleeding complications after TAVR. METHODS: The study included 1446 patients undergoing TAVR, of whom 623 received partial and 823 full heparin antagonization. The primary endpoint was a composite of 30-day mortality, life-threatening, and major bleeding. Safety endpoints included stroke and myocardial infarction at 30 days. RESULTS: Full antagonization of heparin resulted in lower rates of the primary endpoint as compared to partial heparin reversal (5.6% vs. 10.4%, p < .01), which was mainly driven by lower rates of life-threatening (0.5% vs. 1.6%, p = .05) and major bleeding (3.2% vs. 7.5%, p < .01). Moreover, the incidence of major vascular complications was significantly lower in patients with full heparin reversal (3.5% vs. 7.5%, p < .01). The need for red-blood-cell transfusion was lower in patients receiving full as compared to partial heparin antagonization (10.4% vs. 15.9%, p < .01). No differences were observed in the incidence of stroke and myocardial infarction between patients with full and partial heparin reversal (2.2% vs. 2.6%, p = .73 and 0.2% vs. 0.4%, p = .64, respectively). CONCLUSIONS: Full heparin antagonization resulted in significantly lower rates of life-threatening and major bleeding after TAVR as compared to partial heparin reversal. The occurrence of stroke and myocardial infarction was low and comparable between both groups.


Assuntos
Estenose da Valva Aórtica , Infarto do Miocárdio , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Heparina/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Protaminas/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/induzido quimicamente , Infarto do Miocárdio/prevenção & controle , Infarto do Miocárdio/complicações , Valva Aórtica/cirurgia
15.
Cell Stress Chaperones ; 27(5): 561-572, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36029373

RESUMO

Pulmonary arterial hypertension (PAH) is driven by vascular remodelling due to inflammation and cellular stress, including endoplasmic reticulum stress (ER stress). The main ER-stress chaperone, glucose-regulated protein 78 kDa (GRP78), is known to have protective effects in inflammatory diseases through extracellular signalling. The aim of this study is to investigate its significance in PAH. Human pulmonary arterial smooth muscle cells (PASMC) were stimulated with compounds that induce ER stress, after which the secretion of GRP78 into the cell medium was analysed by western blot. We found that when ER stress was induced in PASMC, there was also a time-dependent secretion of GRP78. Next, naïve PASMC were treated with conditioned medium (CM) from the ER-stressed donor PASMC. Incubation with CM from ER-stressed PASMC reduced the viability, oxidative stress, and expression of inflammatory and ER-stress markers in target cells. These effects were abrogated when the donor cells were co-treated with Brefeldin A to inhibit active secretion of GRP78. Direct treatment of PASMC with recombinant GRP78 modulated the expression of key inflammatory markers. Additionally, we measured GRP78 plasma levels in 19 PAH patients (Nice Group I) and correlated the levels to risk stratification according to ESC guidelines. Here, elevated plasma levels of GRP78 were associated with a favourable risk stratification. In conclusion, GRP78 is secreted by PASMC under ER stress and exhibits protective effects from the hallmarks of PAH in vitro. Circulating GRP78 may serve as biomarker for risk adjudication of patients with PAH. Proposed mechanism of ER-stress-induced GRP78 secretion by PASMC. Extracellular GRP78 can be measured as a circulating biomarker and is correlated with favourable clinical characteristics. Conditioned medium from ER-stressed PASMC reduces extensive viability, ROS formation, inflammation, and ER stress in target cells. These effects can be abolished by blocking protein secretion in donor cells by using Brefeldin A.


Assuntos
Hipertensão Pulmonar , Artéria Pulmonar , Brefeldina A/metabolismo , Brefeldina A/farmacologia , Brefeldina A/uso terapêutico , Proliferação de Células , Células Cultivadas , Meios de Cultivo Condicionados/farmacologia , Glucose/metabolismo , Humanos , Hipertensão Pulmonar/tratamento farmacológico , Hipertensão Pulmonar/metabolismo , Inflamação/metabolismo , Músculo Liso Vascular/metabolismo , Miócitos de Músculo Liso/metabolismo , Artéria Pulmonar/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Remodelação Vascular
16.
Catheter Cardiovasc Interv ; 100(5): 850-859, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35989489

RESUMO

BACKGROUND: A significant number of patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) suffer from extra-aortic cardiac damage. Few studies have investigated strategies to quantify cardiac damage and stratify patients accordingly in different risk groups. The aim of this retrospective multicenter study was to provide a user-friendly simplified staging system based on the proposed classification system of Généreux et al. as a tool to evaluate the prognosis of patients undergoing TAVR more easily. Moreover, we analyzed changes in cardiac damage after TAVR. METHODS: We assessed cardiac damage in patients, who underwent TAVR at the Heart Center Bonn or Düsseldorf, using pre- and postprocedural transthoracic echocardiography. Patients were assigned to the staging system proposed by Généreux et al. according to the severity of their baseline cardiac damage. Based on the established system, we created a simplified staging system to facilitate improved applicability. Finally, we compared clinical outcomes between the groups and evaluated changes in cardiac damage after TAVR. RESULTS: A total of 933 TAVR patients were included in the study. We found a significant association between cardiac damage and 1-year all-cause mortality (stage 0: 0% vs. stage 1: 3% vs. stage 2: 6.6%; p < 0.009). In multivariate analysis, cardiac damage was an independent predictor of 1-year all-cause mortality (hazard ratio: 2.0, 95% confidence interval: 1.1-3.8; p = 0.03). CONCLUSIONS: In patients undergoing TAVR, cardiac damage is associated with enhanced mortality. A simplified staging system can help identify patients at high risk for an adverse outcome.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Fatores de Risco , Estudos Retrospectivos , Índice de Gravidade de Doença
17.
Clin Res Cardiol ; 111(11): 1276-1285, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35849156

RESUMO

BACKGROUND: Data on Device-related Thrombus (DRT) after left atrial appendage closure (LAAC) remain scarce. This study aimed to investigate risk factors for DRT from centers reporting to the EUROC-DRT registry. METHODS: We included 537 patients (112 with DRT and 425 without DRT) who had undergone LAAC between 12/2008 and 04/2019. Baseline and implantation characteristics, anti-thrombotic treatment and clinical outcomes were compared between both groups in uni- and multivariate analyses. Additional propensity-score matching (PSM) was conducted to focus on the role of implantation characteristics. RESULTS: Patients with DRT showed higher rates of previous stroke/transient ischemic attack (TIA) (49.1% vs. 34.7%, p < 0.01), spontaneous echocardiographic contrast (SEC) (44.9% vs. 27.7%, p < 0.01) and lower left atrial appendage (LAA) peak emptying velocity (35.4 ± 18.5 vs. 42.4 ± 18.0 cm/s, p = 0.02). Occluders implanted in DRT patients were larger (25.5 ± 3.8 vs. 24.6 ± 3.5 mm, p = 0.03) and implanted deeper in the LAA (mean depth: 7.6 ± 4.7 vs. 5.7 ± 4.7 mm, p < 0.01). Coverage of the appendage ostium was achieved less often in DRT patients (69.5% vs. 81.5%, p < 0.01), while DRT patients were less frequently on oral anticoagulation (7.1% vs. 16.7%, p < 0.01). Multivariate analysis identified age, prior stroke/TIA and SEC as independent risk factors for DRT. After PSM, implantation depth was found to be predictive. Rates of stroke/TIA were higher in DRT patients (13.5% vs. 3.8%, Hazard Ratio: 4.21 [95%-confidence interval: 1.88-9.49], p < 0.01). CONCLUSIONS: DRT after LAAC is associated with adverse outcome and appears to be of multifactorial origin, depending on patient characteristics, anticoagulation regimen and device position.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Trombose , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Trombose/diagnóstico , Trombose/epidemiologia , Trombose/etiologia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Risco , Ecocardiografia , Sistema de Registros , Anticoagulantes/uso terapêutico
18.
J Pers Med ; 12(7)2022 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-35887554

RESUMO

Background: Data to support the routine use of embolic protection devices for stroke prevention during transcatheter aortic valve replacement (TAVR) are controversial. Identifying patients at high risk for peri-procedural cerebrovascular events may facilitate effective patient selection for embolic protection devices during TAVR. Aim: To generate a risk score model for stratifying TAVR patients according to peri-procedural cerebrovascular events risk. Methods and results: A total of 8779 TAVR patients from 12 centers worldwide were included. Peri-procedural cerebrovascular events were defined as an ischemic stroke or a transient ischemic attack occurring ≤24 h from TAVR. The peri-procedural cerebrovascular events rate was 1.4% (n = 127), which was independently associated with 1-year mortality (hazards ratio (HR) 1.78, 95% confidence interval (CI) 1.06−2.98, p < 0.028). The TASK risk score parameters were history of stroke, use of a non-balloon expandable valve, chronic kidney disease, and peripheral vascular disease, and each parameter was assigned one point. Each one-point increment was associated with a significant increase in peri-procedural cerebrovascular events risk (OR 1.96, 95% CI 1.56−2.45, p < 0.001). The TASK score was dichotomized into very-low, low, intermediate, and high (0, 1, 2, 3−4 points, respectively). The high-risk TASK score group (OR 5.4, 95% CI 2.06−14.16, p = 0.001) was associated with a significantly higher risk of peri-procedural cerebrovascular events compared with the low TASK score group. Conclusions: The proposed novel TASK risk score may assist in the pre-procedural risk stratification of TAVR patients for peri-procedural cerebrovascular events.

19.
Circulation ; 146(24): 1836-1854, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-35862223

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a well-established treatment option for high- and intermediate-risk patients with severe symptomatic aortic valve stenosis. A majority of patients exhibit improvements in left ventricular ejection fraction (LVEF) after TAVR in response to TAVR-associated afterload reduction. However, a specific role for circulating microRNAs (miRNAs) in the improvement of cardiac function for patients after TAVR has not yet been investigated. Here, we profiled the differential expression of miRNAs in circulating extracellular vesicles (EVs) in patients after TAVR and, in particular, the novel role of circulating miR-122-5p in cardiomyocytes. METHODS: Circulating EV-associated miRNAs were investigated by use of an unbiased Taqman-based human miRNA array. Several EV miRNAs (miR-122-5p, miR-26a, miR-192, miR-483-5p, miR-720, miR-885-5p, and miR-1274) were significantly deregulated in patients with aortic valve stenosis at day 7 after TAVR compared with the preprocedural levels in patients without LVEF improvement. The higher levels of miR-122-5p were negatively correlated with LVEF improvement at both day 7 (r=-0.264 and P=0.015) and 6 months (r=-0.328 and P=0.0018) after TAVR. RESULTS: Using of patient-derived samples and a murine aortic valve stenosis model, we observed that the expression of miR-122-5p correlates negatively with cardiac function, which is associated with LVEF. Mice with graded wire injury-induced aortic valve stenosis demonstrated a higher level of miR-122-5p, which was related to cardiomyocyte dysfunction. Murine ex vivo experiments revealed that miR-122-5p is highly enriched in endothelial cells compared with cardiomyocytes. Coculture experiments, copy-number analysis, and fluorescence microscopy with Cy3-labeled miR-122-5p demonstrated that miR-122-5p can be shuttled through large EVs from endothelial cells into cardiomyocytes. Gain- and loss-of-function experiments suggested that EV-mediated shuttling of miR-122-5p increases the level of miR-122-5p in recipient cardiomyocytes. Mechanistically, mass spectrometry, miRNA pulldown, electrophoretic mobility shift assay, and RNA immunoprecipitation experiments confirmed that miR-122-5p interacts with the RNA-binding protein hnRNPU (heterogeneous nuclear ribonucleoprotein U) in a sequence-specific manner to encapsulate miR-122-5p into large EVs. On shuttling, miR-122-5p reduces the expression of the antiapoptotic gene BCL2 by binding to its 3' untranslated region to inhibit its translation, thereby decreasing the viability of target cardiomyocytes. CONCLUSIONS: Increased levels of circulating proapoptotic EV-incorporated miR-122-5p are associated with reduced LVEF after TAVR. EV shuttling of miR-122-5p regulates the viability and apoptosis of cardiomyocytes in a BCL2-dependent manner.


Assuntos
Estenose da Valva Aórtica , MicroRNA Circulante , Vesículas Extracelulares , MicroRNAs , Substituição da Valva Aórtica Transcateter , Humanos , Camundongos , Animais , Substituição da Valva Aórtica Transcateter/métodos , Função Ventricular Esquerda/fisiologia , Volume Sistólico/fisiologia , Células Endoteliais , Estenose da Valva Aórtica/cirurgia , MicroRNAs/genética , Proteínas Proto-Oncogênicas c-bcl-2 , Valva Aórtica/cirurgia , Resultado do Tratamento
20.
Clin Res Cardiol ; 111(12): 1367-1376, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35852581

RESUMO

BACKGROUND: Liver dysfunction is associated with an increased risk of mortality after cardiac interventions. The Fibrosis-4 (FIB-4 index), a marker of hepatic fibrosis, has been associated with a worse prognosis in heart failure. The prognostic relevance of the index in patients undergoing transcatheter aortic valve replacement (TAVR) is unknown. The aim of this study was to evaluate the clinical implications associated with the FIB-4 index in patients undergoing TAVR. METHODS: Between May 2012 and June 2019, 941 patients undergoing TAVR were stratified into a low or high FIB-4 index group, based on a cutoff value that was determined according to a receiver operating characteristic curve predicting 1-year all-cause mortality. RESULTS: Patients with a high FIB-4 index (n = 480), based on the cutoff value of 1.82, showed higher rates of pulmonary hypertension (43.8% vs. 31.8%, p < 0.01), right-ventricular systolic dysfunction (29.5% vs. 19.2%, p < 0.01) and larger inferior vena cava diameter (1.6 ± 0.6 cm vs. 1.3 ± 0.6 cm, p < 0.01) than patients with a low FIB-4 index (n = 461). Furthermore, a high FIB-4 index was associated with a significantly higher cumulative 1-year all-cause mortality (17.5% vs. 10.2%, p < 0.01) and non-cardiovascular mortality (12.1% vs. 2.5%, p < 0.01), compared to a low FIB-4 index. Multivariable analysis revealed that a high FIB-4 index was independently associated with all-cause mortality (HR: 1.75 [95% CI: 1.18-2.59], p < 0.01). CONCLUSIONS: A high FIB-4 index is associated with right-sided heart overload and an increased risk of mortality in patients undergoing TAVR. The FIB-4 index may be useful as an additional predictor of outcomes in these patients.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Prognóstico , Índice de Gravidade de Doença , Fibrose , Valva Aórtica/cirurgia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...