Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Surgeon ; 20(5): e288-e295, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35144899

RESUMO

BACKGROUND: Surgical resection, where appropriate, remains one of the best treatment options for hepatocellular carcinoma (HCC), however outcomes can be compromised by the development of liver failure. We reviewed our experience of liver resection for HCC patients to identify factors that may predict the development of post-hepatectomy liver failure (PHLF) and survival. METHODS: A single centre retrospective cohort study. Data was collected between 1999 and 2017 from all patients undergoing HCC resection in a tertiary university hospital from electronic medical records. PHLF was defined as per the International Study Group for Liver Surgery criteria. Variables with p < 0.15 on univariate analysis were included in a multivariate binary logistic regression model. Kaplan-Meier analyses were used to determine correlations with overall survival (OS) and disease-free survival (DFS), and variables with p < 0.15 on univariate analysis selected for a step-down Cox proportional hazard regression model. RESULTS: Overall, 120 patients underwent liver resection within the study period, of which 22 (18%) developed PHLF. Patients with normal INR ≤1.20 at day 2 did not develop PHLF whereas patients with INR >1.60 were at significant risk. Resection of multiple tumours (odds ratio 21.63, p = 0.002) and deranged postoperative day 2 INR>1.6 (odds ratio 21.05, p < 0.0001) were identified as independent prognostic markers of PHLF. CONCLUSION: The use of INR measurement at day 2 predicts PHLF and may enable us to objectively identify and stratify patients who may be eligible for enhanced recovery programs from those who will merit close monitoring in high dependency areas.


Assuntos
Carcinoma Hepatocelular , Falência Hepática , Neoplasias Hepáticas , Hepatectomia/efeitos adversos , Humanos , Coeficiente Internacional Normatizado , Falência Hepática/etiologia , Falência Hepática/cirurgia , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos
3.
Clin Radiol ; 75(5): 398.e9-398.e18, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31005269

RESUMO

Acute biliary conditions include cholangitis, obstruction, and biliary leakage. All these conditions may lead to severe biliary sepsis, which can be life threatening. Infected obstructed cholangitis is a medical emergency that requires active medical therapy and early biliary decompression is recommended. This article provides an overview of the clinical presentations and management of biliary sepsis. The technique, clinical applications, and outcomes of percutaneous transhepatic biliary drainage and those related to gall bladder drainage are highlighted. Future alternatives to conventional biliary drainage are discussed.


Assuntos
Colangite/diagnóstico por imagem , Colangite/terapia , Doença Aguda , Antibacterianos/uso terapêutico , Biomarcadores/análise , Colangite/complicações , Descompressão Cirúrgica , Drenagem , Hidratação , Humanos , Radiografia Intervencionista , Stents
4.
Clin Radiol ; 74(6): 429-434, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30846190

RESUMO

AIM: To provide an update of current practice in iliac artery intervention in the UK. MATERIALS AND METHODS: Ninety-nine interventional units across the UK completed online submission forms for iliac angioplasty and stent procedures between 2011 and 2014 (inclusive) for the British Iliac Angioplasty and Stenting (BIAS) IV registry. RESULTS: Data for 8,294 procedures were submitted during the study period. A total of 12,253 iliac segments were treated in 10,311 legs. The commonest indication was claudication (n=5219, 64.4%). Of the cases performed, 6,582 (80.8%) were performed electively with 3,548 (44.8%) of the procedures performed as a day-case and 6,586 (54%) of the lesions were treated with stents. Successful endovascular intervention (residual stenosis ≤49%) was achieved in 11,847 (97%) of treated segments, with residual stenosis in 1.5%. One point five percent of lesions could not be crossed with a wire. Limb complications were recorded in 366 (3.5%), resulting in 141 patients undergoing an unplanned intervention and 173 (2.2%) patients had a systemic complication. There were 84 deaths prior to discharge, of which 13 (15%) were procedure related. Both systemic and limb complication rates were higher in patients undergoing treatment for critical ischaemia. CONCLUSION: Iliac stenting and angioplasty are associated with high technical success with a low complication rate. These data provide up-to-date statistics for patient information and future audit and benchmarking purposes.


Assuntos
Angioplastia/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/terapia , Artéria Ilíaca/diagnóstico por imagem , Radiologia Intervencionista/métodos , Sistema de Registros , Stents , Humanos , Resultado do Tratamento , Reino Unido
5.
Clin Oncol (R Coll Radiol) ; 31(1): 58-66, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30297164

RESUMO

AIMS: Patients with chemotherapy-refractory colorectal cancer liver metastases have limited therapeutic options. Selective internal radiation therapy (SIRT) delivers yttrium 90 microspheres as a minimally invasive procedure. This prospective, single-arm, observational, service-evaluation study was part of National Health Service England Commissioning through Evaluation. METHODS: Patients eligible for treatment had histologically confirmed carcinoma with liver-only/liver-dominant metastases with clinical progression during or following oxaliplatin-based and irinotecan-based chemotherapy. All patients received SIRT plus standard of care. The primary outcome was overall survival; secondary outcomes included safety, progression-free survival (PFS) and liver-specific PFS (LPFS). RESULTS: Between December 2013 and March 2017, 399 patients were treated in 10 centres with a median follow-up of 14.3 months (95% confidence interval 9.2-19.4). The median overall survival was 7.6 months (95% confidence interval 6.9-8.3). The median PFS and LPFS were 3.0 months (95% confidence interval 2.8-3.1) and 3.7 months (95% confidence interval 3.2-4.3), respectively. During the follow-up period, 143 patients experienced an adverse event and 8% of the events were grade 3. CONCLUSION: Survival estimates from this pragmatic study show clinical outcomes attainable in the National Health Service comparable with previously published data. This study shows the value of a registry-based commissioning model to aid national commissioning decisions for highly specialist cancer treatments.


Assuntos
Neoplasias Colorretais/complicações , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
6.
J Magn Reson Imaging ; 45(6): 1846-1853, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27902859

RESUMO

PURPOSE: To evaluate the diagnostic performance of velocity- and acceleration-sensitized noncontrast-enhanced magnetic resonance angiography (NCE-MRA) of the infrageniculate arteries using contrast-enhanced MRA (CE-MRA) as a reference standard. MATERIALS AND METHODS: Twenty-four patients with symptoms of peripheral arterial disease were recruited. Each patient's infrageniculate arterial tree was examined using a velocity-dependent flow-sensitized dephasing (VEL-FSD) technique, an acceleration-dependent (ACC-FSD) technique, and our conventional CE-MRA technique performed at 1.5T. The images were independently reviewed by two experienced vascular radiologists, who evaluated each vessel segment to assess visibility, diagnostic confidence, venous contamination, and detection of pathology. RESULTS: In all, 432 segments were evaluated by each of the three techniques by each reader in total. Overall diagnostic confidence was rated as moderate or high in 98.5% of segments with CE-MRA, 92.1% with VEL-FSD, and 79.9% with ACC-FSD. No venous contamination was seen in 96% of segments with CE-MRA, 72.2% with VEL-FSD, and 85.8% with ACC-FSD. Per-segment, per-limb, and per-patient sensitivities for detecting significant stenotic disease were 63.4%, 73%, and 92%, respectively, for ACC-FSD, and 65.3%, 87.2%, and 96% for VEL-FSD, and as such no significant statistical change was detected using McNemar's chi-squared test with P-values of 1.00, 0.13, and 0.77 obtained, respectively. CONCLUSION: Flow-dependent NCE-MRA techniques may have a role to play in evaluation of patients with peripheral vascular disease. Increased sensitivity of a velocity-based technique compared to an acceleration-based technique comes at the expense of greater venous contamination. LEVEL OF EVIDENCE: 2J. Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;45:1846-1853.


Assuntos
Aumento da Imagem/métodos , Perna (Membro)/irrigação sanguínea , Perna (Membro)/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Doença Arterial Periférica/diagnóstico por imagem , Processamento de Sinais Assistido por Computador , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Perna (Membro)/patologia , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Clin Radiol ; 71(7): 716.e1-6, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27107673

RESUMO

AIM: To assess the utilisation of an interventional radiology day unit (RDU), the rates of on-time discharges, the financial performance of the unit, and finally, the patient satisfaction rates. MATERIALS AND METHODS: Data regarding the unit utilisation, discharge times, and complications were retrospectively collected for the first 2 years of operation of the unit (1 April 2013 to 1 January 2015). In addition, monitoring the activity going through the RDU and applying a contribution margin to the freed-up beds measured the financial performance. The data were provided by the finance department of the hospital. Satisfaction survey questionnaires were sent randomly by post to 100 patients who had been previously admitted to the RDU. RESULTS: During the study period, 3019 patients were admitted to the RDU, comprising 1426 during the first year and 1513 during the second. On average, 5.6 patients were discharged from the RDU on every working day during the first year and 7.1 patients during the second (21% increase in the discharge rate). Given the 8-hour working time configuration of the unit, a realistic 80% utilisation rate of the RDU's seven beds could free a total of 1400 inpatient bed days over a full year. The cost of delivering these episodes of care was reduced by approximately 50%. From the financial data, it was estimated that the RDU managed to achieve a total of £393,000 in savings for the Trust for the financial year 2013-2014. The return rate of the patient satisfaction survey was 40%. All patients were satisfied with their overall RDU experience. CONCLUSION: The RDU has brought significant benefits for patients and the Trust without compromises in safety or quality.


Assuntos
Custos de Cuidados de Saúde/estatística & dados numéricos , Alta do Paciente/economia , Satisfação do Paciente/estatística & dados numéricos , Radiografia Intervencionista/economia , Radiografia Intervencionista/estatística & dados numéricos , Revisão da Utilização de Recursos de Saúde , Eficiência Organizacional/economia , Humanos , Tempo de Internação/economia , Estudos Longitudinais , Alta do Paciente/estatística & dados numéricos , Reino Unido/epidemiologia
8.
Anaesthesia ; 69(12): 1322-30, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25040430

RESUMO

Peripherally inserted central catheters are often positioned blindly in the central circulation, and this may result in high malposition rates, especially in critically ill patients. Recently, a new technology has been introduced (Sherlock 3CG Tip Positioning System) that uses an electro-magnetic system to guide positioning in the superior vena cava, and then intra-cavity ECG to guide positioning at the cavo-atrial junction. In this observational study, we investigated how the Sherlock 3CG Tip Positioning System would affect peripherally inserted central catheter malposition rates, defined using a post-insertion chest radiograph, in critically ill patients. A total of 239 catheters positioned using the Sherlock 3CG Tip Positioning System were analysed. When an adequate position was defined as low superior vena cava or cavo-atrial junction, 134 catheters (56.1%; 95% CI 50-62%) were malpositioned. When an adequate position was defined as mid/low superior vena cava, cavo-atrial junction or high right atrium (≤ 2 cm from cavo-atrial junction), 49 (20.5%; 95% CI 16-26%) catheters were malpositioned. These malposition rates are significantly lower than our own historical data, which used a 'blind' anthropometric technique to guide peripherally inserted central catheter insertion.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateterismo Venoso Central/métodos , Cateterismo Periférico/métodos , Cateteres Venosos Centrais , Cateterismo Periférico/efeitos adversos , Humanos , Estudos Retrospectivos
9.
Clin Radiol ; 68(10): 983-91, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23743363

RESUMO

This review will describe the indications for the various small bowel containing transplants. The importance of early referral will be highlighted. Radiologists play a central role in assessing these complex patients prior to transplantation. Furthermore, in the postoperative period, radiologists play an important part in diagnosing and treating complications.


Assuntos
Diagnóstico por Imagem , Gastroenteropatias/diagnóstico , Gastroenteropatias/cirurgia , Intestino Delgado/transplante , Vísceras/transplante , Humanos
10.
Anaesthesia ; 68(5): 484-91, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23488895

RESUMO

Peripherally inserted central catheters are increasingly used to provide access to the central venous circulation. They are commonly positioned 'blind' using a variety of anthropometric techniques and operator experience to direct insertion length. Malposition rates are poorly defined because of differing insertion techniques, difficulties defining anatomical tip position on chest radiographs, controversy over what constitutes an adequate catheter position and possible differences between patient groups. We have developed a reproducible method to define catheter positions on chest radiograph and have applied this in a retrospective analysis of 256 ICU and 243 non-ICU catheter insertions over a 6-month period. Two different definitions were used for adequate position. 'Blind' positioning of peripherally inserted central catheters was associated with a definition-dependent malposition rate of 42-76%. Malposition rates were significantly higher in ICU patients. Emerging technologies may assist in reducing these high rates.


Assuntos
Cateterismo Venoso Central/métodos , Cateterismo Periférico/métodos , Catéteres , Radiografia Torácica/métodos , Antropometria , Cuidados Críticos , Fluoroscopia , Humanos , Unidades de Terapia Intensiva , Erros Médicos , Estudos Retrospectivos , Veias/anatomia & histologia
11.
Clin Radiol ; 67(5): 461-7, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22176725

RESUMO

AIM: To evaluate whether virtual unenhanced (VU) computed tomography (CT) images generated of the aorta were of sufficient quality to replace the conventional unenhanced (CU) images. MATERIALS AND METHODS: Forty-nine patients undergoing examination of the thoracic or abdominal aorta were examined using a dual-energy protocol. VU images were generated from the arterial phase images and compared to the CU images. Objective analysis was performed by drawing paired regions of interest (ROIs) within the thoracic and abdominal aorta and measuring the radiodensity in Hounsfield units attenuation within the ROIs. Subjective analysis was performed by two experienced readers evaluating the VU images in terms of noise, quality, calcium loss, and overall acceptability. RESULTS: The attenuation was significantly higher in the VU images compared to the CU images within the thoracic aorta (p < 0.01) but not within the abdominal aorta (p = 0.15). Overall the VU images of the abdominal aorta were deemed acceptable as replacements for the CU images in 93% of cases. For the thoracic aorta, the VU images were deemed acceptable in only 12% of cases, primarily due to pulsation artefact. CONCLUSION: VU images of the abdominal aorta are acceptable as replacements for the CU images in the vast majority of cases; however, they are not suitable as replacements for the CU images of the thoracic aorta.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aorta Torácica/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Trombose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
12.
BMJ Case Rep ; 20112011 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-22696750

RESUMO

Almost half the patients with colorectal cancer will develop liver metastasis at some stage during their disease. Potentially curative surgical resection is possible in some of these patients. In those patients unsuitable for surgery, treatment with systemic chemotherapy and external radiation therapy is relatively ineffective. Many studies have described the successful use of selective internal radiation therapy (SIRT) with 90Y-SIR-Spheres microspheres in patients with inoperable liver metastasis. The authors report on a patient who has been in complete remission for 1 year after treatment with SIRT.


Assuntos
Adenocarcinoma/radioterapia , Adenocarcinoma/secundário , Braquiterapia/métodos , Neoplasias Colorretais/patologia , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Microesferas , Idoso , Braquiterapia/instrumentação , Feminino , Humanos
14.
Clin Radiol ; 63(11): 1254-64, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18929043

RESUMO

Pseudoaneurysms are uncommon and their aetiology is varied. They occur in numerous anatomical locations and present with a multitude of clinical presentations sometimes life-threatening. This review describes the causes, sites, and presentations of uncommon pseudoaneurysms, as well as illustrating their diagnostic appearances and endovascular management.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Artérias/lesões , Embolização Terapêutica , Humanos , Abuso de Substâncias por Via Intravenosa/complicações , Tomografia Computadorizada por Raios X
15.
J Med Imaging Radiat Oncol ; 52(2): 140-7, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18373805

RESUMO

Acute appendicitis is a diagnosis that can be made on clinical symptoms and signs but can often be extremely challenging. Difficulties arise particularly when the presentation is atypical, and this can lead to untoward sequelae. In this review, we present the range of presentations of atypical appendicitis, the variety of management options and the potential value of CT.


Assuntos
Apendicite/diagnóstico , Apêndice/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Apendicite/terapia , Doença Crônica , Diagnóstico Diferencial , Feminino , Humanos , Masculino
16.
Eur J Vasc Endovasc Surg ; 35(4): 436-8, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18226566

RESUMO

To demonstrate the use of a commercially available branch stent graft system, designed to preserve the internal iliac artery (IIA) in common iliac artery (CIA) aneurysms (CIAA) in two patients, who had undergone previous abdominal aortic aneurysm (AAA) surgery.


Assuntos
Angioplastia/instrumentação , Implante de Prótese Vascular/instrumentação , Aneurisma Ilíaco/cirurgia , Stents , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/cirurgia , Humanos , Aneurisma Ilíaco/complicações , Masculino
19.
Br J Radiol ; 77(919): 620-2, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15238412

RESUMO

Pulmonary arteriovenous malformations (PAVMs) are rare. We discuss a case of an 81-year-old female who attended hospital with a haemothorax. Ultrasound not only demonstrated an echogenic effusion in the right pleural space, but also identified an associated tubular structure. Doppler was applied to this structure, which exhibited pulsatile flow. This raised the possibility of a PAVM, which was subsequently confirmed on CT and angiography. Although, PAVM is a rare cause of haemothorax, the diagnosis should still be considered and transpleural ultrasound can detect these malformations non-invasively by the bedside.


Assuntos
Malformações Arteriovenosas/diagnóstico por imagem , Artéria Pulmonar/anormalidades , Veias Pulmonares/anormalidades , Idoso , Idoso de 80 Anos ou mais , Malformações Arteriovenosas/complicações , Feminino , Hemotórax/etiologia , Humanos , Artéria Pulmonar/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Ultrassonografia
20.
Br J Radiol ; 75(897): 775-81, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12200249

RESUMO

Acute appendicitis has extremely varied clinical presentations. A delayed or missed diagnosis may result in severe adverse consequences. Helical CT is evolving as an important diagnostic aid, but the CT signs can be varied and can easily be overlooked by the unwary. This pictorial review illustrates the spectrum of radiological signs and appearances of appendicitis on helical CT.


Assuntos
Apendicite/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Adolescente , Adulto , Idoso , Apendicite/fisiopatologia , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...