Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J Magn Reson Imaging ; 59(2): 661-672, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37259965

RESUMO

BACKGROUND: Sensitive detection and quantification of cerebral glucose is desired. PURPOSE: To quantify cerebral glucose by detecting the H1-α-glucose peak at 5.23 ppm in 1 H magnetic resonance spectroscopy at 7 T. STUDY TYPE: Prospective. SUBJECTS: Twenty-eight non-fasted healthy subjects (aged 20-28 years). FIELD STRENGTH/SEQUENCE: Short echo time stimulated echo acquisition mode (short-TE STEAM) and semi-localized by adiabatic selective refocusing (semi-LASER) at 7 T. ASSESSMENT: Single voxel spectra were obtained from the posterior cingulate cortex (27-mL) using a 32-channel head coil. The H1-α-glucose peak in the spectrum with retrospective removal of the residual water peak was fitted using LCModel with a glucose basis set of only the H1-α-glucose peak. Conventional spectral analysis was performed with a glucose basis set of a full spectral pattern of glucose, also. Fitting precision was evaluated with Cramér-Rao lower bounds (CRLBs). The repeatability of glucose quantification via the semi-LASER sequence was tested. STATISTICAL TESTS: Paired or Welch's t-test were used for normally distributed values. A P value of <0.05 was considered significant. The repeatability of measures was analyzed using coefficient of variation (CV). RESULTS: Removal of the residual water peak improved the flatness and stability of baselines around the H1-α-glucose peak and reduced CRLBs for fitting the H1-α-glucose peak. The semi-LASER sequence was superior to the short-TE STEAM in the higher signal-to-noise ratio of the H1-α-glucose peak (mean ± SD 7.9 ± 2.5, P < 0.001). The conventional analysis overfitted the H1-α-glucose peak. The individual CVs of glucose quantification by detecting the H1-α-glucose peak were smaller than the corresponding CRLBs. DATA CONCLUSION: Cerebral glucose concentration is quantitated to be 1.07 mM by detecting the H1-α-glucose peak in the semi-LASER spectra. Despite requiring long scan times, detecting the H1-α-glucose peak allows true glucose quantification free from the influence of overlapping taurine and macromolecule signals. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Encéfalo , Água , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Espectroscopia de Ressonância Magnética/métodos , Razão Sinal-Ruído , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo
2.
Heliyon ; 9(7): e18357, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37539101

RESUMO

Rationale and objectives: Macromolecules (MMs) affect the precision and accuracy of neurochemical quantification in magnetic resonance spectroscopy. A measured MM basis is increasingly used in LCModel analysis combined with a spline baseline, whose stiffness is controlled by a parameter named DKNTMN. The effects of measured MM basis and DKNTMN were investigated. Materials and methods: Twenty-six healthy subjects were prospectively enrolled and scanned twice using a short echo-time Stimulated Echo Acquisition Mode (STEAM) at 7-T. Using LCModel, analyses were conducted using the simulated MM basis (MMsim) with DKNTMN 0.15 and an MM basis measured inhouse (MMmeas) with DKNTMN of 0.15, 0.30, 0.60 and 1.00. Cramér-Rao lower bound (CRLB) and the concentrations of gamma-aminobutyric acid (GABA), glutamate and excitatory-inhibitory ratio (EIR), in addition to MMs were statistically analyzed. Measurement stability was evaluated using coefficient of variation (CV). Results: CRLBs of GABA were significantly lower when using MMsim than MMmeas; those of glutamate were 2-3. GABA concentrations were significantly higher in the analysis using MMsim than MMmeas where concentrations were significantly higher with DKNTMN of 0.15 or 0.30 than 0.60 or 1.00. Difference in glutamate concentration was not significant. EIRs showed the same difference as in GABA depending on the DKNTMN values. CVs between test-retest scans were relatively stable for glutamate but became larger as DKNTMN increased for GABA and EIR. Conclusion: Neurochemical quantification depends on the parameters of the basis sets used for fitting. Analysis using MMmeas with DKNTMN of 0.30 conformed best to previous studies and is recommended.

3.
Magn Reson Med ; 89(5): 2048-2061, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36576212

RESUMO

PURPOSE: The purpose of this study is to assess the intra- and interscan repeatability of free-breathing phase-resolved functional lung (PREFUL) MRI in stable pediatric cystic fibrosis (CF) lung disease in comparison to static breath-hold hyperpolarized 129-xenon MRI (Xe-MRI) and pulmonary function tests. METHODS: Free-breathing 1-hydrogen MRI and Xe-MRI were acquired from 15 stable pediatric CF patients and seven healthy age-matched participants on two visits, 1 month apart. Same-visit MRI scans were also performed on a subgroup of the CF patients. Following the PREFUL algorithm, regional ventilation (RVent) and regional flow volume loop cross-correlation maps were determined from the free-breathing data. Ventilation defect percentage (VDP) was determined from RVent maps (VDPRVent ), regional flow volume loop cross-correlation maps (VDPCC ), VDPRVent ∪ VDPCC , and multi-slice Xe-MRI. Repeatability was evaluated using Bland-Altman analysis, coefficient of repeatability (CR), and intraclass correlation. RESULTS: Minimal bias and no significant differences were reported for all PREFUL MRI and Xe-MRI VDP parameters between intra- and intervisits (all P > 0.05). Repeatability of VDPRVent , VDPCC , VDPRVent ∪ VDPCC , and multi-slice Xe-MRI were lower between the two-visit scans (CR = 14.81%, 15.36%, 16.19%, and 9.32%, respectively) in comparison to the same-day scans (CR = 3.38%, 2.90%, 1.90%, and 3.92%, respectively). pulmonary function tests showed high interscan repeatability relative to PREFUL MRI and Xe-MRI. CONCLUSION: PREFUL MRI, similar to Xe-MRI, showed high intravisit repeatability but moderate intervisit repeatability in CF, which may be due to inherent disease instability, even in stable patients. Thus, PREFUL MRI may be considered a suitable outcome measure for future treatment response studies.


Assuntos
Fibrose Cística , Humanos , Criança , Fibrose Cística/diagnóstico por imagem , Respiração , Pulmão/diagnóstico por imagem , Testes de Função Respiratória , Isótopos de Xenônio , Imageamento por Ressonância Magnética , Xenônio
4.
Eur Radiol ; 33(4): 2536-2547, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36460925

RESUMO

OBJECTIVE: To compare standard (STD-DWI) single-shot echo-planar imaging DWI and simultaneous multislice (SMS) DWI during whole-body positron emission tomography (PET)/MRI regarding acquisition time, image quality, and lesion detection. METHODS: Eighty-three adults (47 females, 57%), median age of 64 years (IQR 52-71), were prospectively enrolled from August 2018 to March 2020. Inclusion criteria were (a) abdominal or pelvic tumors and (b) PET/MRI referral from a clinician. Patients were excluded if whole-body acquisition of STD-DWI and SMS-DWI sequences was not completed. The evaluated sequences were axial STD-DWI at b-values 50-400-800 s/mm2 and the apparent diffusion coefficient (ADC), and axial SMS-DWI at b-values 50-300-800 s/mm2 and ADC, acquired with a 3-T PET/MRI scanner. Three radiologists rated each sequence's quality on a five-point scale. Lesion detection was quantified using the anatomic MRI sequences and PET as the reference standard. Regression models were constructed to quantify the association between all imaging outcomes/scores and sequence type. RESULTS: The median whole-body STD-DWI acquisition time was 14.8 min (IQR 14.1-16.0) versus 7.0 min (IQR 6.7-7.2) for whole-body SMS-DWI, p < 0.001. SMS-DWI image quality scores were higher than STD-DWI in the abdomen (OR 5.31, 95% CI 2.76-10.22, p < 0.001), but lower in the cervicothoracic junction (OR 0.21, 95% CI 0.10-0.43, p < 0.001). There was no significant difference in the chest, mediastinum, pelvis, and rectum. STD-DWI detected 276/352 (78%) lesions while SMS-DWI located 296/352 (84%, OR 1.46, 95% CI 1.02-2.07, p = 0.038). CONCLUSIONS: In cancer staging and restaging, SMS-DWI abbreviates acquisition while maintaining or improving the diagnostic yield in most anatomic regions. KEY POINTS: • Simultaneous multislice diffusion-weighted imaging enables faster whole-body image acquisition. • Simultaneous multislice diffusion-weighted imaging maintains or improves image quality when compared to single-shot echo-planar diffusion-weighted imaging in most anatomical regions. • Simultaneous multislice diffusion-weighted imaging leads to superior lesion detection.


Assuntos
Imagem de Difusão por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Imagem Corporal Total , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons/métodos , Reprodutibilidade dos Testes , Masculino , Imagem Corporal Total/métodos
5.
Magn Reson Med ; 88(4): 1818-1827, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35713379

RESUMO

PURPOSE: To evaluate multicenter repeatability and reproducibility of T1 and T2 maps generated using MR fingerprinting (MRF) in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom and in prostatic tissues. METHODS: MRF experiments were performed on 5 different 3 Tesla MRI scanners at 3 different institutions: University Hospitals Cleveland Medical Center (Cleveland, OH), Brigham and Women's Hospital (Boston, MA) in the United States, and Diagnosticos da America (Rio de Janeiro, RJ) in Brazil. Raw MRF data were reconstructed using a Gadgetron-based MRF online reconstruction pipeline to yield quantitative T1 and T2 maps. The repeatability of T1 and T2 values over 6 measurements in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology MRI system phantom was assessed to demonstrate intrascanner variation. The reproducibility between the 4 clinical scanners was assessed to demonstrate interscanner variation. The same-day test-retest normal prostate mean T1 and T2 values from peripheral zone and transitional zone were also compared using the intraclass correlation coefficient and Bland-Altman analysis. RESULTS: The intrascanner variation of values measured using MRF was less than 2% for T1 and 4.7% for T2 for relaxation values, within the range of 307.7 to 2360 ms for T1 and 19.1 to 248.5 ms for T2 . Interscanner measurements showed that the T1 variation was less than 4.9%, and T2 variation was less than 8.1% between multicenter scanners. Both T1 and T2 values in in vivo prostatic tissue demonstrated high test-retest reliability (intraclass correlation coefficient > 0.92) and strong linear correlation (R2  > 0.840). CONCLUSION: Prostate MRF measurements of T1 and T2 are repeatable and reproducible between MRI scanners at different centers on different continents for the above measurement ranges.


Assuntos
Imageamento por Ressonância Magnética , Próstata , Brasil , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Imagens de Fantasmas , Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes
6.
J Magn Reson Imaging ; 55(6): 1696-1707, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35312203

RESUMO

BACKGROUND: Evaluation of structural lung abnormalities with magnetic resonance imaging (MRI) has previously been shown to be predictive of clinical neonatal outcomes in preterm birth. MRI during free-breathing with phase-resolved functional lung (PREFUL) may allow for complimentary functional information without exogenous contrast. PURPOSE: To investigate the feasibility of structural and functional pulmonary MRI in a cohort of neonates and infants with no cardiorespiratory disease. Macrovascular pulmonary blood flows were also evaluated. STUDY TYPE: Prospective. POPULATION: Ten term infants with no clinically defined cardiorespiratory disease were imaged. Infants recruited from the general population and neonatal intensive care unit (NICU) were studied. FIELD STRENGTH/SEQUENCE: T1 -weighted VIBE, T2 -weighted BLADE uncorrected for motion. Ultrashort echo time (UTE) and 3D-flow data were acquired during free-breathing with self-navigation and retrospective reconstruction. Single slice 2D-gradient echo (GRE) images were acquired during free-breathing for PREFUL analysis. Imaging was performed at 3 T. ASSESSMENT: T1 , T2 , and UTE images were scored according to the modified Ochiai scheme by three pediatric body radiologists. Ventilation/perfusion-weighted maps were extracted from free-breathing GRE images using PREFUL analysis. Ventilation and perfusion defect percent (VDP, QDP) were calculated from the segmented ventilation and perfusion-weighted maps. Time-averaged cardiac blood velocities from three-dimensional-flow were evaluated in major pulmonary arteries and veins. STATISTICAL TEST: Intraclass correlation coefficient (ICC). RESULTS: The ICC of replicate structural scores was 0.81 (95% CI: 0.45-0.95) across three observers. Elevated Ochiai scores, VDP, and QDP were observed in two NICU participants. Excluding these participants, mean ± standard deviation structural scores were 1.2 ± 0.8, while VDP and QDP were 1.0% ± 1.1% and 0.4% ± 0.5%, respectively. Main pulmonary arterial blood flows normalized to body surface area were 3.15 ± 0.78 L/min/m2 . DATA CONCLUSION: Structural and functional pulmonary imaging is feasible using standard clinical MRI hardware (commercial whole-body 3 T scanner, table spine array, and flexible thoracic array) in free-breathing infants. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.


Assuntos
Nascimento Prematuro , Criança , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional , Recém-Nascido , Pulmão , Imageamento por Ressonância Magnética , Gravidez , Estudos Prospectivos , Estudos Retrospectivos
7.
IEEE ASME Trans Mechatron ; 27(1): 407-417, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35185321

RESUMO

Brachytherapy is a radiation based treatment that is implemented by precisely placing focused radiation sources into tumors. In advanced interstitial cervical cancer bracytherapy treatment, this is performed by placing a metallic rod ("stylet") inside a hollow cylindrical tube ("catheter") and advancing the pair to the desired target. The stylet is removed once the target is reached, followed by the insertion of radiation sources into the catheter. However, manually advancing an initially straight stylet into the tumor with millimeter spatial accuracy has been a long-standing challenge, which requires multiple insertions and retractions, due to the unforeseen stylet deflection caused by the stiff muscle tissue that is traversed. In this paper, we develop a novel tendon-actuated deflectable stylet equipped with MR active-tracking coils that may enhance brachytherapy treatment outcomes by allowing accurate stylet trajectory control. Herein we present the design concept and fabrication method, followed by the kinematic and mechanics models of the deflectable stylet. The hardware and theoretical models are extensively validated via benchtop and MRI-guided characterization. At insertion depths of 60 mm, benchtop phantom targeting tests provided a targeting error of 1. 23 ± 0. 47 mm, and porcine tissue targeting tests provided a targeting error of 1. 65 ± 0. 64 mm, after only a single insertion. MR-guided experiments indicate that the stylet can be safely and accurately located within the MRI environment.

8.
J Neuroimaging ; 32(3): 377-388, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35099832

RESUMO

Ultra-high-field 7.0 Tesla (T) MRI offers substantial gains in signal-to-noise ratio (SNR) over 3T and 1.5T, but for over two decades has remained a research tool, while 3T scanners have achieved widespread clinical use. This much slower translation of 7T relates to daunting technical challenges encountered in ultra-high-field human MR imaging. The recent introduction of United States Food and Drug Administration (FDA)-approved clinical 7T scanners promises to be a watershed for many 7T neuroimaging applications, including epilepsy imaging. The high SNR of 7T allows clinical imaging of fine neuroanatomic detail at unprecedented spatial resolution, helping with detection and differentiation of subtle, potentially treatable lesions undetectable or suboptimally assessed at 3T. The accompanying research paper reports our group's analysis of 7T MRI efficacy in epilepsy treatment planning. Here, we introduce the technical background and clinical approach we currently use, in order to assist clinical epileptologists and neuroimagers contemplating, creating, or referring patients to a clinical 7T epilepsy imaging service. We describe a tiered epilepsy imaging strategy and protocols designed to optimize 7T value and work around signal intensity variation and signal loss artifacts, which remain significant challenges to full exploitation of 7T clinical value. We describe FDA-approved techniques for mitigating these artifacts and briefly outline techniques currently under development, but not yet FDA approved. Finally, we discuss the major issues in 7T patient safety and toleration, outlining their physical causes and effects on workflow, and provide references to more comprehensive technical reviews for readers seeking greater technical detail.


Assuntos
Epilepsia , Imageamento por Ressonância Magnética , Epilepsia/diagnóstico por imagem , Epilepsia/terapia , Humanos , Imageamento por Ressonância Magnética/métodos , Neuroimagem , Seleção de Pacientes , Razão Sinal-Ruído
9.
ERJ Open Res ; 7(4)2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34760997

RESUMO

INTRODUCTION: Evidence suggests that abnormalities occur in the lung microvasculature in idiopathic pulmonary fibrosis (IPF). We hypothesised that dynamic contrast-enhanced (DCE)-magnetic resonance imaging (MRI) could detect alterations in permeability, perfusion and extracellular extravascular volume in IPF, thus providing in vivo regional functional information not otherwise available. METHODS: Healthy controls and IPF subjects underwent DCE-MRI of the thorax using a dynamic volumetric radial sampling sequence and administration of gadoterate meglumine at a dose of 0.1 mmol·kg-1 at 2 mL·s-1. Model-free analysis of signal intensity versus time curves in regions of interest from a lower, middle and upper axial plane, a posterior coronal plane and the whole lung yielded parameters reflective of perfusion and permeability (peak enhancement and rate of contrast arrival (kwashin)) and the extracellular extravascular space (rate of contrast clearance (kwashout)). These imaging parameters were compared between IPF and healthy control subjects, and between fast/slow IPF progressors. RESULTS: IPF subjects (n=16, 56% male, age (range) 67.5 (60-79) years) had significantly reduced peak enhancement and slower kwashin in all measured lung regions compared to the healthy volunteers (n=17, 65% male, age (range) 58 (51-63) years) on unadjusted analyses consistent with microvascular alterations. kwashout, as a measure of the extravascular extracellular space, was significantly slower in the lower lung and posterior coronal regions in the IPF subjects consistent with an increased extravascular extracellular space. All estimates were attenuated after adjusting for age. Similar trends were observed, but only the associations with kwashin in certain lung regions remained statistically significant. Among IPF subjects, kwashout rates nearly perfectly discriminated between those with rapidly progressive disease versus those with stable/slowly progressive disease. CONCLUSIONS: DCE-MRI detects changes in the microvasculature and extravascular extracellular space in IPF, thus providing in vivo regional functional information.

10.
Abdom Radiol (NY) ; 46(7): 3288-3300, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33666735

RESUMO

PURPOSE: To evaluate the feasibility of Quantitative Ultrashort-Time-to-Echo Contrast-Enhanced (QUTE-CE) MRA using ferumoxytol as a contrast agent for abdominal angiography in the kidney. METHODS: Four subjects underwent ferumoxytol-enhanced MRA with the 3D UTE Spiral VIBE WIP sequence at 3 T. Image quality metrics were quantified, specifically the blood Signal-to-Noise Ratio (SNR), blood-tissue Contrast-to-Noise Ratio (CNR) and Intraluminal Signal Heterogeneity (ISH) from both the aorta and inferior vena cava (IVC). Morphometric analysis of the vessels was performed using manual approach and semi-automatic approach using Vascular Modeling ToolKit (VMTK). Image quality and branching order were compared between QUTE-CE MRA and the Gadolinium (Gd) CEMRA reference image. RESULTS: QUTE-CE MRA provides a bright blood snapshot that delineates arteries and veins equally in the same scan. The maximum SNR and CNR values were 3,282 ± 1,218 and 1,295 ± 580, respectively - significantly higher than available literature values using other CEMRA techniques. QUTE-CE MRA had lower ISH and depicted higher vessel branching order (7th vs 3rd) within the kidney compared to a standard dynamic clinical Gd CEMRA scan. Morphometric analysis yielded quantitative results for the total kidney volume, total cyst volume and for diameters of the branching arterial network down to the 7th branch. Vessel curvature was significantly increased (p < 0.001) in the presence of a renal cyst compared to equivalent vessels in normal kidney regions. CONCLUSION: QUTE-CE MRA is feasible for kidney angiography, providing greater detail of kidney vasculature, enabling quantitative morphometric analysis of the abdominal and intra-renal vessels and yielding metrics relevant to vascular diseases while using a contrast agent ferumoxytol that is safe for CKD patients.


Assuntos
Óxido Ferroso-Férrico , Angiografia por Ressonância Magnética , Meios de Contraste , Gadolínio , Humanos , Rim/diagnóstico por imagem
11.
Quant Imaging Med Surg ; 11(1): 9-20, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33392007

RESUMO

BACKGROUND: Proton magnetic resonance spectroscopy (MRS) provides a unique opportunity for in vivo measurements of the brain's metabolic profile. Two methods of mainstream data acquisition are compared at 7 T, which provides certain advantages as well as challenges. The two representative methods have seldom been compared in terms of measured metabolite concentrations and different scan times. The current study investigated proton MRS of the posterior cingulate cortex using a semi-localized by adiabatic selective refocusing (sLASER) sequence and a short echo time (TE) stimulated echo acquisition mode (sSTEAM) sequence, and it compared their reliability and repeatability at 7 T using a 32-channel head coil. METHODS: Sixteen healthy subjects were prospectively enrolled and scanned twice with an off-bed interval between scans. The scan parameters for sLASER were a TR/TE of 6.5 s/32 ms and 32 and 48 averages (sLASER×32 and sLASER×48, respectively). The scan parameters for sSTEAM were a TR/TE of 4 s/5 ms and 32, 48, and 64 averages (sSTEAM4×32, sSTEAM4×48, and sSTEAM4×64, respectively) in addition to that with a TR/TE of 8 s/5 ms and 32 averages (sSTEAM8×32). Data were analyzed using LCModel. Metabolites quantified with Cramér-Rao lower bounds (CRLBs) >50% were classified as not detected, and metabolites quantified with mean or median CRLBs ≤20% were included for further analysis. The SNR, CRLBs, coefficient of variation (CV), and metabolite concentrations were statistically compared using the Shapiro-Wilk test, one-way ANOVA, or the Friedman test. RESULTS: The sLASER spectra for N-acetylaspartate + N-acetylaspartylglutamate (tNAA) and glutamate (Glu) had a comparable or higher SNR than sSTEAM spectra. Ten metabolites had lower CRLBs than prefixed thresholds: aspartate (Asp), γ-aminobutyric acid (GABA), glutamine (Gln), Glu, glutathione (GSH), myo-inositol (Ins), taurine (Tau), the total amount of phosphocholine + glycerophosphocholine (tCho), creatine + phosphocreatine (tCr), and tNAA. Performance of the two sequences was satisfactory except for GABA, for which sLASER yielded higher CRLBs (≥18%) than sSTEAM. Some significant differences in CRLBs were noted, but they were ≤2% except for GABA and Gln. Signal averaging significantly lowered CRLBs for some metabolites but only by a small amount. Measurement repeatability as indicated by median CVs was ≤10% for Gln, Glu, Ins, tCho, tCr, and tNAA in all scans, and that for Asp, GABA, GSH, and Tau was ≥10% under some scanning conditions. The CV for GABA according to sLASER was significantly higher than that according to sSTEAM, whereas the CV for Ins was higher according to sSTEAM. An increase in signal averaging contribute little to lower CVs except for Ins. CONCLUSIONS: Both sequences quantified brain metabolites with a high degree of precision and repeatability. They are comparable except for GABA, for which sSTEAM would be a better choice.

12.
Acad Radiol ; 28(8): e209-e218, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32532639

RESUMO

RATIONALE AND OBJECTIVES: Phase resolved functional lung (PREFUL) magnetic resonance imaging (MRI) is a free-breathing 1H-based technique that produces maps of fractional ventilation (FV). This study compared ventilation defect percent (VDP) calculated using PREFUL to hyperpolarized (HP) 129Xe MRI and pulmonary function tests in pediatric cystic fibrosis (CF). MATERIALS AND METHODS: 27 pediatric participants were recruited (mean age 13.0 ± 2.7), including 6 with clinically stable CF, 11 CF patients undergoing a pulmonary exacerbation (PEx), and 10 healthy controls. Spirometry was performed to measure forced expiratory volume in 1 second (FEV1), along with nitrogen multiple breath washout to measure lung clearance index (LCI). VDP was calculated from single central coronal slice PREFUL FV maps and the corresponding HP 129Xe slice. RESULTS: The stable CF group had a normal FEV1 (p = 0.41) and elevated LCI (p = 0.007). The CF PEx group had a decreased FEV1 (p < 0.0001) and elevated LCI (p < 0.0001). PREFUL and HP 129Xe VDP were significantly different between the CF PEx and healthy groups (p < 0.05). In the stable CF group, PREFUL and HP 129Xe VDP were not significantly different from the healthy group (p = 0.18 and 0.08, respectively). There was a correlation between PREFUL and HP 129Xe VDP (R2 = 0.31, p = 0.004), and both parameters were significantly correlated with FEV1 and LCI. CONCLUSION: PREFUL MRI is feasible in pediatric CF, distinguishes patients undergoing pulmonary exacerbations compared to healthy subjects, and correlates with HP 129Xe MRI as well as functional measures of disease severity. PREFUL MRI does not require breath-holds and is straight forward to implement on any MRI scanner.


Assuntos
Fibrose Cística , Adolescente , Criança , Fibrose Cística/diagnóstico por imagem , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Testes de Função Respiratória , Isótopos de Xenônio
14.
AJR Am J Roentgenol ; 215(1): 94-104, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32348181

RESUMO

OBJECTIVE. The purpose of this study was to develop a motion insensitive clinical dynamic contrast-enhanced MRI (DCE-MRI) protocol to assess the response of pleural tumors in clinical trials. MATERIALS AND METHODS. Thirty-two patients with pleura-based lesions were administered contrast material and imaged with gradient-recalled echo DCE-MRI sequence variants: either a traditional cartesian k-space acquisition (FLASH), a time-resolved imaging with stochastic trajectories acquisition (TWIST), or a radial stack-of-stars acquisition (radial) sequence in addition to other standard-of-care imaging sequences. Each image acquisition's sensitivity to motion was evaluated by comparing the motion of the thoracic border in 3D throughout the acquisition. One-way ANOVA was used to compare the image quality between different acquisitions. The 95% CIs were calculated for mean thoracic border displacement. The effects of motion on kinetic parameter estimation were explored with simulations according to clinically acquired data. RESULTS. Radial was the most motion-robust sequence with subvoxel mean displacement in the superior-inferior direction (0.4 ± 1.2 [SD] mm). FLASH showed intermediate displacement (4.6 ± 2.0 mm), whereas TWIST was most sensitive to motion (6.4 ± 3.4 mm). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the images acquired with the radial sequence were on par or better than the FLASH and TWIST sequences when reconstructed with an improved density compensation algorithm. Simulations showed that motion on scans showing pleural-based lesions can lead to markedly inaccurate kinetic parameter estimation and inappropriate kinetic model convergence within a nested model analysis. CONCLUSION. A practical radial k-space trajectory sequence that provides motion-insensitive pharmacokinetic parameters was incorporated as part of the DCE-MRI protocol of pleural tumors. Validation and usefulness in clinical trials assessing response to therapy is needed.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias Pleurais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Respiração , Sensibilidade e Especificidade , Razão Sinal-Ruído
15.
Magn Reson Imaging ; 69: 16-21, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32126265

RESUMO

PURPOSE: Computed tomography (CT) imaging is the standard to assess interstitial lung disease. Magnetic resonance (MR) is potentially advantageous due to superior tissue characterization and better assessment of blood flow dynamics. This study aimed to evaluate idiopathic pulmonary fibrosis (IPF) using prototype 4D Stack of Stars GRE (StarVIBE) MR and compare it to CT. METHOD: This IRB-approved prospective study included 13 patients [5F:8M; average age 66 ±â€¯8.1 years] with pulmonary fibrosis, and 12 healthy controls [3F:9M; average age 55 ±â€¯3.6 years]. MR of the chest included noncontrast steady-state free precession imaging (SSFP) and free-breathing 4D StarVIBE sequence with intravenous contrast administration up to 160 s. The images were assessed for quality and artifacts. The image resolution was evaluated based on the visibility of the smallest bronchi, vessels, lymph nodes, and pleural fissures. Independent assessment of reticulation, ground-glass opacity, and traction bronchiectasis was performed and compared to CT. RESULTS: The StarVIBE images had fewer artifacts and higher spatial resolution. The findings associated with IPF were significantly better seen with StarVIBE, with superior CT correlation. CONCLUSION: Contrast-enhanced free-breathing StarVIBE MR can generate high quality images with good correlation to CT in patients with IPF, and with high spatial and temporal resolution to generate rapid sequential dynamic images.


Assuntos
Doenças Pulmonares Intersticiais/diagnóstico por imagem , Imageamento por Ressonância Magnética , Fibrose Pulmonar/diagnóstico por imagem , Idoso , Artefatos , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Pulmão/patologia , Doenças Pulmonares Intersticiais/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fibrose Pulmonar/patologia , Respiração , Tomografia Computadorizada por Raios X
16.
Invest Radiol ; 55(5): 310-317, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31977600

RESUMO

PURPOSE: The aim of this study was to develop a method to delineate the lethally frozen-tissue region (temperature less than -40°C) arising from interventional cryoablation procedures using a short tau inversion-recovery ultrashort echo-time (STIR-UTE) magnetic resonance (MR) imaging sequence. This method could serve as an intraprocedural validation of the completion of tumor ablation, reducing the number of local recurrences after cryoablation procedures. MATERIALS AND METHODS: The method relies on the short T1 and T2* relaxation times of frozen soft tissue. Pointwise Encoding Time with Radial Acquisition, a 3-dimensional UTE sequence with TE = 70 microseconds, was optimized with STIR to null tissues with a T1 of approximately 271 milliseconds, the threshold T1. Because the T1 relaxation time of frozen tissue in the temperature range of -40°C < temperature < -8°C is shorter than the threshold T1 at the 3-tesla magnetic field, tissues in this range should appear hyperintense. The sequence was evaluated in ex vivo frozen tissue, where image intensity and actual tissue temperatures, measured by thermocouples, were correlated. Thereafter, the sequence was evaluated clinically in 12 MR-guided prostate cancer cryoablations, where MR-compatible cryoprobes were used to destroy cancerous tissue and preserve surrounding normal tissue. RESULTS: The ex vivo experiment using a bovine muscle demonstrated that STIR-UTE images showed regions approximately between -40°C and -8°C as hyperintense, with tissues at lower and higher temperatures appearing dark, making it possible to identify the region likely to be above the lethal temperature inside the frozen tissue. In the clinical cases, the STIR-UTE images showed a dark volume centered on the cryoprobe shaft, Vinner, where the temperature is likely below -40°C, surrounded by a doughnut-shaped hyperintense volume, where the temperature is likely between -40°C and -8°C. The hyperintense region was itself surrounded by a dark volume, where the temperature is likely above -8°C, permitting calculation of Vouter. The STIR-UTE frozen-tissue volumes, Vinner and Vouter, appeared significantly smaller than signal voids on turbo spin echo images (P < 1.0 × 10), which are currently used to quantify the frozen-tissue volume ("the iceball"). The ratios of the Vinner and Vouter volumes to the iceball were 0.92 ± 0.08 and 0.29 ± 0.07, respectively. In a single postablation follow-up case, a strong correlation was seen between Vinner and the necrotic volume. CONCLUSIONS: Short tau inversion-recovery ultrashort echo-time MR imaging successfully delineated the area approximately between -40°C and -8°C isotherms in the frozen tissue, demonstrating its potential to monitor the lethal ablation volume during MR-guided cryoablation.


Assuntos
Criocirurgia/métodos , Imageamento por Ressonância Magnética/métodos , Monitorização Intraoperatória/métodos , Neoplasias da Próstata/cirurgia , Animais , Bovinos , Humanos , Masculino , Neoplasias da Próstata/diagnóstico , Temperatura
17.
Radiol Cardiothorac Imaging ; 2(2): e190066, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33778549

RESUMO

PURPOSE: To evaluate the interobserver variability associated with quantitative and qualitative MRI assessments of malignant pleural mesothelioma (MPM). MATERIALS AND METHODS: Patients with MPM who underwent uniform-protocol preoperative MRI between 2009 and 2014 were included. The MRI-derived tumor volume was estimated. Unidimensional measurements of maximal pleural thickness (P max) and average pleural thickness (P avg) on axial MR images; maximal fissural thickness (F max); maximal diaphragmatic thickness (D max); and average diaphragmatic thickness (D avg) on sagittal reconstructed images were acquired. Interobserver agreement regarding the American Joint Committee on Cancer (AJCC) tumor stage at each criterion level was assessed by using Cohen κ statistics. Agreement between quantitative measurements was assessed by using Bland-Altman plots and intraclass correlation coefficients (ICCs). RESULTS: The study cohort included 349 patients (median age, 68 years [age range, 30-90 years), 273 (78%) of whom were men and 203 (58%) of whom had epithelioid-subtype tumors. Qualitative assessment performed by using the AJCC staging criteria (eighth edition) was concordant in 31% of cases and yielded considerable disagreement (κ = 0.177). Inspection of the Bland-Altman plots led to decisive agreement between the two reviewers regarding MRI-derived tumor volume (ICC, 0.979). There was also a good degree of agreement between the two reviewers regarding unidimensional measurements of D max (ICC, 0.807), D avg (ICC, 0.823), P max (ICC, 0.787), P avg (ICC, 0.787), and F max (ICC, 0.659). CONCLUSION: Quantitative assessment can enhance the clinical staging of MPM. Compared with qualitative assessment, quantitative assessment has low interobserver variability and could yield a tumor size criterion that is currently lacking in the AJCC clinical staging of MPM.Supplemental material is available for this article.© RSNA, 2020.

19.
Abdom Radiol (NY) ; 44(6): 2244-2253, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30838425

RESUMO

PURPOSE: To evaluate the impact of complex-averaging on image quality (IQ) and diagnostic accuracy of acquired and calculated high b value (aHBV, cHBV) images in diffusion-weighted prostate MRI. MATERIALS AND METHODS: This retrospective study included 84 patients who underwent multiparametric prostate MRI at 3 Tesla without endorectal coil. DWIs were acquired at three different b values which included two lower b values (b = 50,900 s/mm2) and one higher b value (aHBV at 2000 s/mm2). The acquired data were postprocessed to generate two different types of trace-weighted images-using conventional magnitude-averaging and complex-averaging. Using lower b values (b = 50,900 s/mm2) from both conventional and complex-averaged image sets, cHBV images (b = 2000 s/mm2) and ADC maps were derived. All image sets were reviewed by two radiologists in different reading sessions to assess image quality and PIRADS. The diagnostic accuracy of different image sets for the detection of prostate lesions was performed by correlating PIRADS and Gleason scores. RESULTS: Complex-averaging did not impact ADC values of the prostate lesions compared to magnitude-averaging (P = 0.08). Complex-averaging improved image quality of acquired high b value and calculated high b value images (P < 0.0001). Complex-averaging also improved the level of confidence (LOC) of the acquired high b value for both readers (P < 0.0001, P < 0.05), but only for reader A in calculated high b value (P < 0.0001). The image quality of calculated high b value images was not significantly different than acquired high b value images. The dataset combining complex-averaging and calculated high b value provided the highest diagnostic accuracy (but not statistically significant) for detection of the significant prostate lesion compared to the magnitude-averaged acquired high b value (79.55% vs. 72.73%; P = 0.317). The mean acquisition time for b = 2000 s/mm2 sequence (aHBV) was 6 min 30 s (± 1 min 16 s) out of a total of 28 min 31 s (± 4 min 26 s) for the entire mp-MRI protocol (approximately 25% of total scan time). CONCLUSION: Complex-averaging provides better image quality and level of confidence without significant impact on ADC values and diagnostic accuracy for detection of the significant prostate lesions . The calculated high b value images are also comparable to (and can substitute) the acquired high b value images which can help in reducing the imaging time.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Biópsia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Prostatectomia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...