Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Arch Prev Riesgos Labor ; 25(1): 8-17, 2022 01 17.
Artigo em Espanhol | MEDLINE | ID: mdl-35037746

RESUMO

Al igual que ya sucedió en 2020, 2021 ha estado dominado por la pandemia de COVID-19. Si hace un año escribíamos esta Nota Editorial con gran preocupación por la evolución de la situación de la infección originada por el SARS-CoV-2 y, a su vez, con grandes esperanzas puestas en las vacunas como estrategia preventiva, la actual viene marcada por la incertidumbre generada por la irrupción de la nueva variante de preocupación: Omicrón….


Assuntos
COVID-19 , Pneumologia , Bibliometria , Humanos , Pandemias/prevenção & controle , SARS-CoV-2
5.
J Clin Epidemiol ; 68(6): 662-73, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25744132

RESUMO

OBJECTIVES: To design and validate a questionnaire to measure visual symptoms related to exposure to computers in the workplace. STUDY DESIGN AND SETTING: Our computer vision syndrome questionnaire (CVS-Q) was based on a literature review and validated through discussion with experts and performance of a pretest, pilot test, and retest. Content validity was evaluated by occupational health, optometry, and ophthalmology experts. Rasch analysis was used in the psychometric evaluation of the questionnaire. Criterion validity was determined by calculating the sensitivity and specificity, receiver operator characteristic curve, and cutoff point. Test-retest repeatability was tested using the intraclass correlation coefficient (ICC) and concordance by Cohen's kappa (κ). RESULTS: The CVS-Q was developed with wide consensus among experts and was well accepted by the target group. It assesses the frequency and intensity of 16 symptoms using a single rating scale (symptom severity) that fits the Rasch rating scale model well. The questionnaire has sensitivity and specificity over 70% and achieved good test-retest repeatability both for the scores obtained [ICC = 0.802; 95% confidence interval (CI): 0.673, 0.884] and CVS classification (κ = 0.612; 95% CI: 0.384, 0.839). CONCLUSION: The CVS-Q has acceptable psychometric properties, making it a valid and reliable tool to control the visual health of computer workers, and can potentially be used in clinical trials and outcome research.


Assuntos
Astenopia/diagnóstico , Astenopia/epidemiologia , Monitoramento Ambiental/normas , Inquéritos Epidemiológicos/normas , Doenças Profissionais/diagnóstico , Doenças Profissionais/epidemiologia , Inquéritos e Questionários/normas , Terminais de Computador , Intervalos de Confiança , Humanos , Projetos Piloto , Curva ROC , Sensibilidade e Especificidade , Síndrome
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...