Water Sci Technol ; 81(8): 1597-1605, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32644953

RESUMO

There is a strongly growing interest for wastewater heat recovery (WWHR) in Sweden and elsewhere, but a lack of adequate tools to determine downstream impacts due to the associated temperature drop. The heat recovery potential and associated temperature drop after heat recovery on a building level is modelled for a case study in Linköping, Sweden. The maximum temperature drop reaches 4.2 °C, with an annual recovered heat of 0.65 kWh · person-1 · day-1. Wastewater temperature out from the heat exchanger was 18.0 °C in winter at the lowest. The drinking water source type can be an important factor when considering wastewater heat recovery.


Assuntos
Temperatura Alta , Águas Residuárias , Estações do Ano , Suécia , Temperatura