Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Nat Commun ; 10(1): 2589, 2019 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-31197138

RESUMO

X-ray free electron lasers (XFELs) create new possibilities for structural studies of biological objects that extend beyond what is possible with synchrotron radiation. Serial femtosecond crystallography has allowed high-resolution structures to be determined from micro-meter sized crystals, whereas single particle coherent X-ray imaging requires development to extend the resolution beyond a few tens of nanometers. Here we describe an intermediate approach: the XFEL imaging of biological assemblies with helical symmetry. We collected X-ray scattering images from samples of microtubules injected across an XFEL beam using a liquid microjet, sorted these images into class averages, merged these data into a diffraction pattern extending to 2 nm resolution, and reconstructed these data into a projection image of the microtubule. Details such as the 4 nm tubulin monomer became visible in this reconstruction. These results illustrate the potential of single-molecule X-ray imaging of biological assembles with helical symmetry at room temperature.


Assuntos
Elétrons , Lasers , Microtúbulos/ultraestrutura , Imagem Molecular/métodos , Tubulina (Proteína)/ultraestrutura , Algoritmos , Cristalografia por Raios X/instrumentação , Cristalografia por Raios X/métodos , Processamento de Imagem Assistida por Computador , Imagem Molecular/instrumentação , Espalhamento de Radiação , Síncrotrons , Raios X
3.
Sci Data ; 5: 180201, 2018 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-30277481

RESUMO

Fluctuation X-ray scattering (FXS) is an emerging experimental technique in which solution scattering data are collected using X-ray exposures below rotational diffusion times, resulting in angularly anisotropic X-ray snapshots that provide several orders of magnitude more information than traditional solution scattering data. Such experiments can be performed using the ultrashort X-ray pulses provided by a free-electron laser source, allowing one to collect a large number of diffraction patterns in a relatively short time. Here, we describe a test data set for FXS, obtained at the Linac Coherent Light Source, consisting of close to 100 000 multi-particle diffraction patterns originating from approximately 50 to 200 Paramecium Bursaria Chlorella virus particles per snapshot. In addition to the raw data, a selection of high-quality pre-processed diffraction patterns and a reference SAXS profile are provided.


Assuntos
Phycodnaviridae , Espalhamento a Baixo Ângulo , Difração de Raios X
4.
IUCrJ ; 5(Pt 5): 531-541, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30224956

RESUMO

Diffraction before destruction using X-ray free-electron lasers (XFELs) has the potential to determine radiation-damage-free structures without the need for crystallization. This article presents the three-dimensional reconstruction of the Melbournevirus from single-particle X-ray diffraction patterns collected at the LINAC Coherent Light Source (LCLS) as well as reconstructions from simulated data exploring the consequences of different kinds of experimental sources of noise. The reconstruction from experimental data suffers from a strong artifact in the center of the particle. This could be reproduced with simulated data by adding experimental background to the diffraction patterns. In those simulations, the relative density of the artifact increases linearly with background strength. This suggests that the artifact originates from the Fourier transform of the relatively flat background, concentrating all power in a central feature of limited extent. We support these findings by significantly reducing the artifact through background removal before the phase-retrieval step. Large amounts of blurring in the diffraction patterns were also found to introduce diffuse artifacts, which could easily be mistaken as biologically relevant features. Other sources of noise such as sample heterogeneity and variation of pulse energy did not significantly degrade the quality of the reconstructions. Larger data volumes, made possible by the recent inauguration of high repetition-rate XFELs, allow for increased signal-to-background ratio and provide a way to minimize these artifacts. The anticipated development of three-dimensional Fourier-volume-assembly algorithms which are background aware is an alternative and complementary solution, which maximizes the use of data.

5.
Cytoskeleton (Hoboken) ; 74(12): 472-481, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28574190

RESUMO

A major goal for X-ray free-electron laser (XFEL) based science is to elucidate structures of biological molecules without the need for crystals. Filament systems may provide some of the first single macromolecular structures elucidated by XFEL radiation, since they contain one-dimensional translational symmetry and thereby occupy the diffraction intensity region between the extremes of crystals and single molecules. Here, we demonstrate flow alignment of as few as 100 filaments (Escherichia coli pili, F-actin, and amyloid fibrils), which when intersected by femtosecond X-ray pulses result in diffraction patterns similar to those obtained from classical fiber diffraction studies. We also determine that F-actin can be flow-aligned to a disorientation of approximately 5 degrees. Using this XFEL-based technique, we determine that gelsolin amyloids are comprised of stacked ß-strands running perpendicular to the filament axis, and that a range of order from fibrillar to crystalline is discernable for individual α-synuclein amyloids.


Assuntos
Actinas/química , Amiloide/química , Escherichia coli/química , Fímbrias Bacterianas/química , Lasers , Raios X , Amiloide/ultraestrutura , Fímbrias Bacterianas/ultraestrutura
6.
Sci Data ; 4: 170079, 2017 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-28654088

RESUMO

Single-particle diffraction from X-ray Free Electron Lasers offers the potential for molecular structure determination without the need for crystallization. In an effort to further develop the technique, we present a dataset of coherent soft X-ray diffraction images of Coliphage PR772 virus, collected at the Atomic Molecular Optics (AMO) beamline with pnCCD detectors in the LAMP instrument at the Linac Coherent Light Source. The diameter of PR772 ranges from 65-70 nm, which is considerably smaller than the previously reported ~600 nm diameter Mimivirus. This reflects continued progress in XFEL-based single-particle imaging towards the single molecular imaging regime. The data set contains significantly more single particle hits than collected in previous experiments, enabling the development of improved statistical analysis, reconstruction algorithms, and quantitative metrics to determine resolution and self-consistency.


Assuntos
Colífagos , Algoritmos , Estrutura Molecular , Difração de Raios X
7.
IUCrJ ; 2(Pt 4): 409-20, 2015 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-26175901

RESUMO

Membrane proteins are key players in biological systems, mediating signalling events and the specific transport of e.g. ions and metabolites. Consequently, membrane proteins are targeted by a large number of currently approved drugs. Understanding their functions and molecular mechanisms is greatly dependent on structural information, not least on complexes with functionally or medically important ligands. Structure determination, however, is hampered by the difficulty of obtaining well diffracting, macroscopic crystals. Here, the feasibility of X-ray free-electron-laser-based serial femtosecond crystallography (SFX) for the structure determination of membrane protein-ligand complexes using microcrystals of various native-source and recombinant P-type ATPase complexes is demonstrated. The data reveal the binding sites of a variety of ligands, including lipids and inhibitors such as the hallmark P-type ATPase inhibitor orthovanadate. By analyzing the resolution dependence of ligand densities and overall model qualities, SFX data quality metrics as well as suitable refinement procedures are discussed. Even at relatively low resolution and multiplicity, the identification of ligands can be demonstrated. This makes SFX a useful tool for ligand screening and thus for unravelling the molecular mechanisms of biologically active proteins.

8.
Nature ; 513(7517): 261-5, 2014 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-25043005

RESUMO

Photosynthesis, a process catalysed by plants, algae and cyanobacteria converts sunlight to energy thus sustaining all higher life on Earth. Two large membrane protein complexes, photosystem I and II (PSI and PSII), act in series to catalyse the light-driven reactions in photosynthesis. PSII catalyses the light-driven water splitting process, which maintains the Earth's oxygenic atmosphere. In this process, the oxygen-evolving complex (OEC) of PSII cycles through five states, S0 to S4, in which four electrons are sequentially extracted from the OEC in four light-driven charge-separation events. Here we describe time resolved experiments on PSII nano/microcrystals from Thermosynechococcus elongatus performed with the recently developed technique of serial femtosecond crystallography. Structures have been determined from PSII in the dark S1 state and after double laser excitation (putative S3 state) at 5 and 5.5 Å resolution, respectively. The results provide evidence that PSII undergoes significant conformational changes at the electron acceptor side and at the Mn4CaO5 core of the OEC. These include an elongation of the metal cluster, accompanied by changes in the protein environment, which could allow for binding of the second substrate water molecule between the more distant protruding Mn (referred to as the 'dangler' Mn) and the Mn3CaOx cubane in the S2 to S3 transition, as predicted by spectroscopic and computational studies. This work shows the great potential for time-resolved serial femtosecond crystallography for investigation of catalytic processes in biomolecules.


Assuntos
Cristalografia por Raios X , Cianobactérias/química , Modelos Moleculares , Complexo de Proteína do Fotossistema II/química , Estrutura Terciária de Proteína
9.
Opt Express ; 19(17): 16542-9, 2011 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-21935018

RESUMO

Single-particle experiments using X-ray Free Electron Lasers produce more than 10(5) snapshots per hour, consisting of an admixture of blank shots (no particle intercepted), and exposures of one or more particles. Experimental data sets also often contain unintentional contamination with different species. We present an unsupervised method able to sort experimental snapshots without recourse to templates, specific noise models, or user-directed learning. The results show 90% agreement with manual classification.

10.
Acta Crystallogr D Biol Crystallogr ; 63(Pt 2): 270-4, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17242521

RESUMO

The fact that protein structures are dynamic by nature and that structure models determined by X-ray crystallography, electron microscopy (EM) and nuclear magnetic resonance (NMR) spectroscopy have limited accuracy limits the precision with which derived properties can be reported. Here, the issue of the precision of calculated solvent-accessible surface areas (ASAs) is addressed. A number of protein structures of different sizes were selected and the effect of random shifts applied to the atomic coordinates on ASA values was investigated. Standard deviations of the ASA calculations were found to range from approximately 10 to approximately 80 A2. Similar values are obtained for a handful of cases in the Protein Data Bank (PDB) where ;ensembles' of crystal structures were refined against the same data set. The ASA values for 69 hen egg-white lysozyme structures were calculated and a standard deviation of the ASA of 81 A2 was obtained (the average ASA value was 6571 A2). The calculated ASA values do not show any correlation with factors such as resolution or overall temperature factors. A molecular-dynamics (MD) trajectory of lysozyme was also analysed. The ASA values during the simulation covered a range of more than 800 A2. If different programs are used, the ASA values obtained for one small protein show a spread of almost 600 A2. These results suggest that in most cases reporting ASA values with a precision better than 10 A2 is probably not realistic and a precision of 50-100 A2 would seem prudent. The precision of buried surface-area calculations for complexes is also discussed.


Assuntos
Modelos Moleculares , Muramidase/química , Solventes/química , Simulação por Computador , Proteínas do Ovo/química , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...