1.
J Arthroplasty ; 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38697321

RESUMO

BACKGROUND: The purpose of this study was to evaluate the impact of direct anterior approach (DAA) or posterior approach (PA) on step and stair counts after total hip arthroplasty using a remotely monitored mobile application with a smartwatch while controlling for baseline characteristics. METHODS: This is a secondary data analysis from a prospective cohort study of patients utilizing a smartphone-based care management platform. The primary outcomes were step and stair counts and changes from baseline through one year. Step and stair counts were available for 1,501 and 847 patients, respectively. Longitudinal regression models were created to control for baseline characteristics. RESULTS: Patients in the DAA group had significantly lower body mass index (P = .049) and comorbidities (P = .028), but there were no significant differences in age (P = .225) or sex (P = .315). The DAA patients had a higher average and improvement from baseline in step count at 2 and 3 weeks postoperatively after controlling for patient characteristics (P = .028 and P = .044, respectively). The average stair counts were higher for DAA patients at one month postoperatively (P = .035), but this difference was not significant after controlling for patient demographics. Average stair ascending speeds and changes from baseline were not different between DAA and PA patients. Descending stair speed was higher at 2 weeks postoperatively for DAA patients, but was no longer higher after controlling for baseline demographics. CONCLUSIONS: After controlling for baseline characteristics, DAA patients demonstrate earlier improvement in step count than PA patients after total hip arthroplasty. However, patient selection and surgeon training may continue to influence outcomes through a surgical approach.

2.
Knee Surg Sports Traumatol Arthrosc ; 30(8): 2759-2767, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34120210

RESUMO

PURPOSE: Alignment errors in medial unicompartmental knee arthroplasty (UKA) predispose to premature implant loosening and polyethylene wear. The purpose of this study was to determine whether a novel CT-free robotic surgical assistant improves the accuracy and reproducibility of bone resections in UKA compared to conventional manual instrumentation. METHODS: Sixty matched cadaveric limbs received medial UKA with either the ROSA® Partial Knee System or conventional instrumentation. Fifteen board-certified orthopaedic surgeons with no prior experience with this robotic application performed the procedures with the same implant system. Bone resection angles in the coronal, sagittal and transverse planes were determined using optical navigation while resection depth was obtained using calliper measurements. Group comparison was performed using Student's t test (mean absolute error), F test (variance) and Fisher's exact test (% within a value), with significance at p < 0.05. RESULTS: Compared to conventional instrumentation, the accuracy of bone resections with CT-free robotic assistance was significantly improved for all bone resection parameters (p < 0.05), other than distal femoral resection depth, which did not differ significantly. Moreover, the variance was significantly lower (i.e. fewer chances of outliers) for five of seven parameters in the robotic group (p < 0.05). All values in the robotic group had a higher percentage of cases within 2° and 3° of the intraoperative plan. No re-cuts of the proximal tibia were required in the robotic group compared with 40% of cases in the conventional group. CONCLUSION: The ROSA® Partial Knee System was significantly more accurate, with fewer outliers, compared to conventional instrumentation. The data reported in our current study are comparable to other semiautonomous robotic devices and support the use of this robotic technology for medial UKA. LEVEL OF EVIDENCE: Cadaveric study, Level V.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Artroplastia do Joelho/métodos , Cadáver , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Reprodutibilidade dos Testes , Procedimentos Cirúrgicos Robóticos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...