Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diabetol Int ; 15(2): 290-296, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38524924

RESUMO

Lipodystrophy is a rare disease characterized by various metabolic complications resulting from the complete or partial loss of adipose tissues and abnormal fat accumulation. Acquired lipodystrophy may occur due to certain drugs, autoimmunity or for unknown reasons. Recently, cases of acquired lipodystrophy after hematopoietic stem cell transplantation (HSCT) have been reported. Leptin administration, used recently to treat generalized lipodystrophy, effectively controlled metabolic complications; however, few reports demonstrated the effectiveness of leptin for acquired partial lipodystrophy. In this report, we present the case of a 17-year-old woman who developed insulin resistance, hypertriglyceridemia, and fatty liver after HSCT. Due to her thin gluteal fat and low blood adiponectin levels, her metabolic abnormalities were attributed to partial lipodystrophy. While both leptin and pemafibrate administration partially attenuated metabolic abnormalities, its effects were relatively limited, probably because the serum leptin levels were maintained, which is not likely in generalized lipodystrophy. Nevertheless, after she developed adjustment disorder and experienced weight loss, along with decreased food intake, her metabolic markers significantly improved. This case suggests the modest effect of leptin and permafibrate in partial lipodystrophy after HSCT, highlighting the importance of diet therapy in metreleptin treatment for acquired partial lipodystrophy.

2.
Neuro Endocrinol Lett ; 43(3): 161-166, 2022 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-36179727

RESUMO

This report details the case of a 41-year-old woman who was diagnosed with insulinoma. As the patient developed severe life-threatening hypoglycemia, we introduced Dexcom G4 Platinum (DG4P), a modern continuous glucose-monitoring system (CGM). The algorithm of the sensor glucose (SG) values of CGM is based on patients with diabThis report details the case of a 41-year-old woman who was diagnosed with insulinoma. As the patient developed severe life-threatening hypoglycemia, we introduced Dexcom G4 Platinum (DG4P), a modern continuous glucose-monitoring system (CGM). The algorithm of the sensor glucose (SG) values of CGM is based on patients with diabetes; therefore, we evaluated the accuracy of DG4P in this patient. The mean absolute relative differences and absolute differences between SG of DG4P and self-monitoring of blood sugar values were 10.8%±8.3% and 6.8±5.7 mg/dL, respectively, in the hypoglycemic region, which verifies DG4P's accuracy. DG4P was found to be useful for monitoring hypoglycemia not only in patients with diabetes but also in those with insulinoma.etes; therefore, we evaluated the accuracy of DG4P in this patient. The mean absolute relative differences and absolute differences between SG of DG4P and self-monitoring of blood sugar values were 10.8%±8.3% and 6.8±5.7 mg/dL, respectively, in the hypoglycemic region, which verifies DG4P's accuracy. DG4P was found to be useful for monitoring hypoglycemia not only in patients with diabetes but also in those with insulinoma.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Insulinoma , Neoplasias Pancreáticas , Feminino , Humanos , Adulto , Glicemia , Platina , Insulinoma/complicações , Automonitorização da Glicemia , Hipoglicemia/etiologia , Hipoglicemiantes , Neoplasias Pancreáticas/complicações , Neoplasias Pancreáticas/tratamento farmacológico
3.
Endocr J ; 68(11): 1367-1372, 2021 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-34719527

RESUMO

Only a few studies of continuous glucose monitoring (CGM) in patients with steroid diabetes have been published. Therefore, we investigated all patients with type 2 diabetes (n = 121) and steroid diabetes (n = 40) who used the FreeStyle Libre Pro® device (Abbott Japan) at Gunma University Hospital between 2017 and 2019. Glycated hemoglobin (HbA1c), mean sensor glucose (SG), and glucose management indicator values were similar in both groups. However, the indices for glycemic variabilities, expressed as standard deviations and percent coefficients of variation, were higher in patients with steroid diabetes than in those with type 2 diabetes. The associations between HbA1c, mean SG, and time in range (TIR) when glucose values were 70-180, <70, or >180 mg/dL were assessed using Pearson's product-moment correlation coefficient, which demonstrated good correlations in both patient groups. However, patients with steroid diabetes had a higher SG and lower TIR than did counterparts with type 2 diabetes who had similar HbA1c levels. To examine the effect of prednisolone on CGM data, we divided patients with steroid diabetes into 2 subgroups according to prednisolone dose (≤5 and >5 mg), and found that the dose of this steroid impacted the associations between HbA1c and CGM data, mean SG, and TIR. In summary, our data highlight the importance of cautiously interpreting CGM data and the optimal HbA1c level in patients with steroid diabetes to prevent diabetes-related complications. Further analyses using other CGM devices are necessary to further validate our findings.


Assuntos
Automonitorização da Glicemia , Glicemia/análise , Diabetes Mellitus/sangue , Glucocorticoides/efeitos adversos , Resistência à Insulina/fisiologia , Idoso , Diabetes Mellitus/induzido quimicamente , Feminino , Hemoglobinas Glicadas/análise , Humanos , Masculino , Pessoa de Meia-Idade
4.
Tohoku J Exp Med ; 255(3): 221-227, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34759118

RESUMO

Achieving the optimal glucose level time in range (TIR), as recently proposed by the "International Consensus on Time in Range," is challenging. We retrospectively analyzed data from 192 patients, including 58 with type 1 diabetes, using the FreeStyle Libre Pro system. This device was used by physicians for continuous glucose monitoring (CGM) and for making therapeutic decisions based on unbiased data, as the patients were blinded to their blood glucose levels during monitoring. The desired 70% TIR among patients with type 2 diabetes corresponded to an HbA1c of 7.7%. Importantly, however, a 70% TIR for patients with type 1 diabetes corresponded to an HbA1c of 6.9%, which diverged markedly from the HbA1c of 7.9% that corresponded to the desired 4% time below range (TBR). Moreover, these dissociations were observed more in patients with type 1 diabetes with a higher % coefficient of variation (> 36%). Hence, while the TIR is strongly correlated with HbA1c, it is difficult to coordinate with the TBR in Japanese patients with type 1 diabetes. As these metrics (which are critical indicators in clinical practice) are rapidly gaining popularity globally, including in Japan, our data strongly support the cautious use of new CGM metrics such as TIR and TBR/time above range, and emphasize the importance of individualized treatment in achieving the optimal TIR and TBR, especially in patients with type 1 diabetes.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Glicemia , Automonitorização da Glicemia , Humanos , Estudos Retrospectivos
5.
World J Clin Cases ; 9(1): 163-169, 2021 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-33511180

RESUMO

BACKGROUND: Hypoglycemia due to non-insulin-producing tumors is referred to as non-islet cell tumor hypoglycemia (NICTH). As NICTH is a rare lesion, the natural course of NICTH is not well understood. We report a case of NICTH that was observed 30 years before the onset of hypoglycemia. CASE SUMMARY: A 50-year-old man was diagnosed with an abnormal right chest shadow during a routine X-ray examination, but no further examination was undertaken because the lesion appeared benign. Thirty years after the tumor discovery, the patient was admitted to the hospital with symptoms of severe hypoglycemia, which was diagnosed as NICTH based on a complete examination. The tumor was resected and found to be a solitary fibrous mass (15.6 cm × 13.7 cm × 10.4 cm); thereafter, the patient's blood glucose levels normalized and he completely recovered. CONCLUSION: NICTH can have an acute onset, even if the tumor has been present and asymptomatic over a long time period.

6.
Chemistry ; 19(44): 15004-11, 2013 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-24105695

RESUMO

Metal-free oxidative C-C coupling by using polyalkoxybenzene-derived diaryliodonium(III) salts as both the oxidant and aryl source has been developed. These salts can induce single-electron-transfer (SET) oxidation to yield electron-rich arenes and subsequently transfer the polyalkoxyphenyl group into in situ generated aromatic radical cations to produce biaryl products. The reaction is promoted by a Lewis acid that activates the iodonium salts. It has been revealed that the reactivity of the salts under acidic conditions is quite different to their known behavior under basic conditions. The reactivity preference of a series of iodonium salts in the SET oxidation and their ligand transfer abilities have been systematically investigated and the results are summarized in this report.


Assuntos
Derivados de Benzeno/química , Oniocompostos/química , Catálise , Transporte de Elétrons , Elétrons , Ligantes , Acoplamento Oxidativo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...