Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur Radiol ; 14(2): 326-33, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14666376

RESUMO

The aim of this study was to evaluate a software tool for non-invasive preoperative volumetric assessment of potential donors in living donated liver transplantation (LDLT). Biphasic helical CT was performed in 56 potential donors. Data sets were post-processed using a non-commercial software tool for segmentation, volumetric analysis and visualisation of liver segments. Semi-automatic definition of liver margins allowed the segmentation of parenchyma. Hepatic vessels were delineated using a region-growing algorithm with automatically determined thresholds. Volumes and shapes of liver segments were calculated automatically based on individual portal-venous branches. Results were visualised three-dimensionally and statistically compared with conventional volumetry and the intraoperative findings in 27 transplanted cases. Image processing was easy to perform within 23 min. Of the 56 potential donors, 27 were excluded from LDLT because of inappropriate liver parenchyma or vascular architecture. Two recipients were not transplanted due to poor clinical conditions. In the 27 transplanted cases, preoperatively visualised vessels were confirmed, and only one undetected accessory hepatic vein was revealed. Calculated graft volumes were 1110 +/- 180 ml for right lobes, 820 ml for the left lobe and 270 +/- 30 ml for segments II+III. The calculated volumes and intraoperatively measured graft volumes correlated significantly. No significant differences between the presented automatic volumetry and the conventional volumetry were observed. A novel image processing technique was evaluated which allows a semi-automatic volume calculation and 3D visualisation of the different liver segments.


Assuntos
Imageamento Tridimensional , Transplante de Fígado , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Doadores Vivos , Intensificação de Imagem Radiográfica , Tomografia Computadorizada Espiral , Adulto , Aorta Abdominal/diagnóstico por imagem , Artéria Celíaca/diagnóstico por imagem , Feminino , Artéria Hepática/diagnóstico por imagem , Humanos , Masculino , Computação Matemática , Artéria Mesentérica Superior/diagnóstico por imagem , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Sensibilidade e Especificidade , Estatística como Assunto
2.
IEEE Trans Med Imaging ; 21(11): 1344-57, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12575871

RESUMO

For liver surgical planning, the structure and morphology of the hepatic vessels and their relationship to tumors are of major interest. To achieve a fast and robust assistance with optimal quantitative and visual information, we present methods for a geometrical and structural analysis of vessel systems. Starting from the raw image data a sequence of image processing steps has to be carried out until a three-dimensional representation of the relevant anatomic and pathologic structures is generated. Based on computed tomography (CT) scans, the following steps are performed. 1) The volume data is preprocessed and the vessels are segmented. 2) The skeleton of the vessels is determined and transformed into a graph enabling a geometrical and structural shape analysis. Using this information the different intrahepatic vessel systems are identified automatically. 3) Based on the structural analysis of the branches of the portal vein, their vascular territories are approximated with different methods. These methods are compared and validated anatomically by means of corrosion casts of human livers. 4) Vessels are visualized with graphics primitives fitted to the skeleton to provide smooth visualizations without aliasing artifacts. The image analysis techniques have been evaluated in the clinical environment and have been used in more than 170 cases so far to plan interventions and transplantations.


Assuntos
Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Imageamento Tridimensional/métodos , Fígado/irrigação sanguínea , Fígado/cirurgia , Cirurgia Assistida por Computador/métodos , Interface Usuário-Computador , Algoritmos , Angiografia/métodos , Cadáver , Artéria Hepática/diagnóstico por imagem , Veias Hepáticas/diagnóstico por imagem , Humanos , Imageamento Tridimensional/instrumentação , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Transplante de Fígado/diagnóstico por imagem , Transplante de Fígado/métodos , Reconhecimento Automatizado de Padrão , Imagens de Fantasmas , Veia Porta/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA