Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Environ Technol ; 42(17): 2690-2699, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31884889

RESUMO

In this study, reinforced hollow fibre membranes were fabricated using different molecular weights of polyvinylidene prolidone (PVP Mw: 10, 40 and 360 kDa) and different take-up speeds (1, 2, 2.6 and 3.5 m/min). Prepared reinforced hollow fibre membranes were characterized in terms of permeability; surface morphology and hydrophilicity; pore size distribution; bovine serum albumin (BSA) rejection and flux recovery ratio. Optimum permeability and BSA rejection were obtained when PVP molecular weight was 40 kDa. After PVP molecular weight determination, advancing speed was changed and it was seen that increasing advancing speed ended up with decreased membrane wall thickness; however, decreased wall thickness increased the probability of irreversible fouling.


Assuntos
Membranas Artificiais , Ultrafiltração , Polímeros , Sulfonas
3.
J Colloid Interface Sci ; 581(Pt B): 884-894, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32877879

RESUMO

HYPOTHESIS: Drying-induced decrease in lip balm surface energy enhances virus adhesion due to the emergence of strong hydrophobic colloid-surface interactions. EXPERIMENTS: A protocol was developed for preparing lip balm coatings to enable physicochemical characterization and adhesion studies. Surface charge and hydrophobicity of four brands of lip balm (dry and hydrated) and human adenovirus 5 (HAdV5) were measured and used to calculate the extended Derjaguin-Landau-Verwey-Overbeek (XDLVO) energy of interactions between lip balm coatings and HAdV5 as well as four other colloids: HAdV40, MS2 and P22 bacteriophages, and SiO2. Quartz crystal microbalance with dissipation monitoring (QCM-D) tests employed SiO2 colloids, HAdV5 and hydrated lip balms. FINDINGS: Drying of lip balms results in a dramatic decrease of their surface energy (δΔGsws≥ 83.0 mJ/m2) making the surfaces highly hydrophobic. For dry lip balms, the interaction of the balm surface with all five colloids is attractive. For lip balms hydrated in 150 mM NaCl (ionic strength of human saliva), XDLVO calculations predict that hydrophilic colloids (MS2, P22, SiO2) may attach into shallow secondary minima. Due to the relative hydrophobicity of human adenoviruses, primary maxima in XDLVO profiles are low or non-existent making irreversible deposition into primary energy minima possible. Preliminary QCM-D tests with SiO2 colloids and HAdV5 confirm deposition on hydrated lip balms.


Assuntos
Dióxido de Silício , Ligação Viral , Coloides , Humanos , Interações Hidrofóbicas e Hidrofílicas , Lábio , Propriedades de Superfície
4.
Environ Technol ; 41(17): 2229-2239, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30574839

RESUMO

We report on the fabrication of AqpZ immobilized flat sheet membranes. The effects of interfacial polymerization conditions as well as proteoliposome concentration were evaluated. Commercial AqpZ were used as positive control for cloned AqpZ. Specific permeate flux of membranes at higher proteoliposome concentrations increased up to 25 times higher than thin film composite membranes; however; MgSO4 rejection is lowered almost to 1.5%. FTIR and SEM confirm immobilization of proteoliposomes. Thermal analysis showed that increasing proteoliposome concentration has no positive effect on the incorporation of proteoliposomes into polyamide structures. On the contrary, at lower proteoliposome concentrations, incorporation of proteoliposomes was found better. When combined membrane performances were compared in terms of specific permeate flux; MgSO4 and humic rejection and flux recovery after humic acid filtration, the performance of cloned AqpZ incorporated membranes (having 0.1 mg/mL proteoliposome concentration and polyamide formed with 2 min piperazine reaction time) improved 1.7 times regarding TFC membranes. According to the results, increasing proteoliposome concentration did not improve nanofiltration membrane performance. On the contrary, lower proteoliposome concentrations were found to be more effective in increasing membrane performance.


Assuntos
Aquaporinas , Membranas Artificiais , Filtração , Proteolipídeos
5.
Environ Technol ; 39(10): 1226-1237, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28463036

RESUMO

Multi-walled carbon nanotubes (MWCNTs) can be used for the fabrication of mixed matrix polymeric membranes that can enhance filtration perfomances of the membranes by modifying membrane surface properties. In this study, detailed characterization and filtration performances of MWCNTs functionalized with COOH group, blended into polymeric flat-sheet membranes were investigated using different polymer types. Morphological characterization was carried out using atomic force microscopy, scanning electron microscopy and contact angle measurements. For filtration performance tests, protein, dextran, E. coli suspension, Xanthan Gum and real activated sludge solutions were used. Experimental data and analyses revealed that Polyethersulfone (PES) + MWCNT-COOH mixed matrix membranes have superior performance abilities compared to other tested membranes.


Assuntos
Nanotubos de Carbono , Polímeros , Purificação da Água , Escherichia coli , Filtração , Membranas Artificiais
6.
ScientificWorldJournal ; 2015: 850530, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26137593

RESUMO

Komurcuoda leachate treatment plant, Istanbul, which consists of membrane bioreactor (MBR) and nanofiltration (NF) system, faced rapid flux decline in membranes after 3-year successful operation. To compensate rapid flux decline in membranes, the fouled membranes were renewed but replacement of the membranes did not solve the problem. To find the reasons and make a comprehensive analysis, membrane autopsy was performed. Visual and physical inspection of the modules and some instrumental analysis were conducted for membrane autopsy. Membranes were found severely fouled with organic and inorganic foulants. Main foulant was iron which was deposited on surface. The main reason was found to be the changing of aerator type of MBR. When surface aerators were exchanged with bottom diffusers which led to increasing of dissolved oxygen (DO) level of the basin, iron particles were oxidized and they converted into particulate insoluble form. It was thought that probably this insoluble form of the iron particles was the main cause of decreased membrane performance. After the diagnosis, a new pretreatment alternative including a new iron antiscalant was suggested and system performance has been recovered.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...