1.
Int Angiol ; 33(4): 309-15, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25056162

RESUMO

AIM: Carotid endarterectomy (CEA) is well recognized procedure in the treatment of patients with significant symptomatic internal carotid artery (ICA) stenosis. Operation reconstitutes physiologic blood flow in the ICA. The influence of CEA on cerebral perfusion (CP) is not well established. Some data suggest increased CP after stenosis correction however evidence in post-endarterectomy patients is scarce. Our aim was to investigate the influence of CEA in patients with symptomatic carotid stenosis on CP parameters by means of perfusion computed tomography (PCT). METHODS: Thirty-four patients with symptomatic severe carotid stenosis qualified for CEA were included. The baseline PCT of the brain according to standardized protocol was performed within 3 weeks prior to surgical procedure. The follow-up PCT was performed between 30-60th day postop. The following perfusion parameters were analyzed: cerebral blood flow (CBF), cerebral blood volume (CBV), peak enhancement intensity (PEI) and time to peak (TTP). Pre- and postoperative average values of these parameters were compared. RESULTS: No death/stroke occurred in the investigated group. Mean preoperative total CBF was 66.2 mL/100 g/min and was not dependent on the degree of the carotid stenosis or the presence of contralateral carotid artery stenosis. Mean postoperative total CBF was significantly lower (61.8 mL/100g/min, P<0.05). No significant changes in PEI, TTP and CBV were observed CONCLUSION: PCT of the brain reveals that CEA in patients with symptomatic carotid stenosis decreased total CBF especially in the contralateral hemisphere.


Assuntos
Artéria Carótida Interna/cirurgia , Estenose das Carótidas/cirurgia , Angiografia Cerebral/métodos , Circulação Cerebrovascular , Endarterectomia das Carótidas , Imagem de Perfusão/métodos , Tomografia Computadorizada por Raios X , Velocidade do Fluxo Sanguíneo , Volume Sanguíneo , Artéria Carótida Interna/fisiopatologia , Artéria Carótida Interna/ultraestrutura , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/fisiopatologia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla
2.
Acta Radiol ; 50(3): 288-95, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19241190

RESUMO

BACKGROUND: Coronary heart disease patients and end-stage renal disease patients have been documented to have an increased amount of coronary artery calcifications (CAC). PURPOSE: To evaluate the distribution of CAC and its influence on interscan variability of measurement in end-stage renal disease and coronary heart disease patients, proven to have calcifications. MATERIAL AND METHODS: 69 patients having CAC, including 34 with coronary heart disease and 35 with end-stage renal disease, were scanned twice with multidetector-row computed tomography (MDCT). Amount of CAC was determined as the number of calcified lesions (CN), total calcium score (CS), calcium volume (CV), and calcium mass (CM). Distribution of CAC was evaluated on a per-patient basis as the median CS and CM of a single lesion. Density of the calcifications was calculated as the patient's CM divided by CV. RESULTS: The overall median CS was 457.2, and the median CM was 75.6 mg. There were no significant differences in the number of calcified lesions, CS, or CM between the two groups. Both CS and CM of a single lesion, as well as the mean calcium density were lower in renal disease patients (P<0.05) than in coronary heart disease subjects. The relative interscan variability of coronary calcium measurement was higher in the renal disease group (P<0.05). There was a negative correlation between the calcium concentration and the relative interscan variability. CONCLUSION: The results indicate that the coronary calcium distribution influences the measurement interscan reproducibility, and the distribution may differ between end-stage renal disease patients and coronary heart disease patients, reflecting the dissimilar nature of coronary calcifications in those groups.


Assuntos
Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Falência Renal Crônica/diagnóstico por imagem , Tomografia Computadorizada Espiral/estatística & dados numéricos , Adulto , Análise de Variância , Cálcio/metabolismo , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Software
3.
Acta Radiol ; 50(2): 226-32, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19096955

RESUMO

BACKGROUND: Perfusion computed tomography (PCT) determination is a minimally invasive and widely available technique for brain blood flow assessment, but its application may be restricted by large variation of results. PURPOSE: To determine the intraobserver, interobserver, and interexamination variability of brain PCT absolute measurements in patients with significant carotid artery stenosis (CAS), and to evaluate the effect of the use of relative perfusion values on PCT reproducibility. MATERIAL AND METHODS: PCT imaging was completed in 61 patients before endarterectomy, and in 38 of these within 4 weeks after treatment. Cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), and peak enhancement intensity (PEI) were calculated with the maximum slope method. Interexamination variability was evaluated based on perfusion of hemisphere contralateral to the treated CAS, from repeated examinations. Interobserver and intraobserver variability were established for the untreated side, based on pretreatment examination. RESULTS: Interobserver and intraobserver variability were highest for CBF measurement (28.8% and 32.5%, respectively), and interexamination variability was the highest for CBV (24.1%). Intraobserver and interobserver variability were higher for absolute perfusion values compared with their respective ratios for CBF and TTP. The only statistically significant difference between perfusion values measured by two observers was for CBF (mean 78.3 vs. 67.5 ml/100 g/min). The interexamination variability of TTP (12.1%) was significantly lower than the variability of other absolute perfusion measures, and the interexamination variability of ratios was significantly lower than absolute values for all the parameters. CONCLUSION: In longitudinal studies of patients with chronic cerebral ischemia, PCT ratios and either TTP or CBV are more suitable measures than absolute CBF values, because of their considerably lower inter- and intraobserver variability. Differences in CBF between two examinations as high as 30% may be considered as significant in such patients.


Assuntos
Estenose das Carótidas/diagnóstico por imagem , Circulação Cerebrovascular , Tomografia Computadorizada por Raios X/métodos , Volume Sanguíneo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estatísticas não Paramétricas
4.
Acta Radiol ; 49(9): 1007-15, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18720083

RESUMO

BACKGROUND: Coronary artery calcium scoring is used as a method for cardiovascular risk stratification and monitoring of coronary heart disease. Automatic software-based calcium mass calculation has been proposed to improve the performance of the procedure. PURPOSE: To compare two algorithms of calcium mass measurement, automatic and phantom calibrated, with respect to correlation, measurement error, and accuracy in vitro and in vivo. MATERIAL AND METHODS: A cardiac phantom with calcium cylinder inserts was scanned with sequential non-overlapping collimation 4 x 2.5 mm, at 120 kV and 165 mAs. Fifty adults (37 men; mean age 46.2 years) were examined with the same settings using prospective electrocardiographic triggering to detect and quantify coronary artery calcifications. Calculations were performed with two methods: software-based automatic calcium mass measurement (ACM) and phantom-calibrated calcium mass measurement (CCM). RESULTS: The total phantom calcium masses measured with ACM and CCM were 175.0+/-13.8 mg and 163.0+/-4.4 mg, respectively (P<0.0001), and ACM produced a higher mean error (4.5 vs. 3.2; P<0.05). Results of ACM and CCM were strongly correlated to each other (R=0.73-0.96; P<0.0001). Mean image noise in the patient study was 8.72+/-1.68 HU. Results of patient calcium scoring with ACM and CCM were significantly different (median 70.3 mg and 59.7 mg, respectively; P<0.0001), with a mean systematic error of 17.5% (limit of agreement between 14.6% and 20.4%). The use of ACM resulted in an altered quartile classification for 14% of patients, as compared to CCM; all of these patients were classified into a higher category. CONCLUSION: Our data indicate that multidetector-row computed tomography coronary calcium mass determination based on dedicated phantom calibration shows lower measurement error than an automatic software-based calculation method. The tested automatic software does not yet seem to be a reliable option for calcium mass measurement.


Assuntos
Cálcio/análise , Vasos Coronários/anatomia & histologia , Tomografia Computadorizada por Raios X/métodos , Vasos Coronários/química , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas