Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pharm Nanotechnol ; 9(5): 372-382, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34951377

RESUMO

BACKGROUND: The desirable levels of lipids, especially in patients with coronary artery disease, might not be achievable with a single lipid-lowering drug; thus, combination therapy using atorvastatin and gemfibrozil seems to be a promising approach. However, the potential for drugdrug interaction needs to be taken into consideration, and the combination (atorvastatin and gemfibrozil) is recommended only when other options for reducing lipids have been exhausted. OBJECTIVES: Many studies are conducted for the determination of atorvastatin or gemfibrozil in biological fluids and tablets; however, the simultaneous determination of the two drugs in complex biological matrices is limited. Consequently, the development of a sensitive method for simultaneous determination of atorvastatin and gemfibrozil in urine samples is urgently needed to make sure that the doses of both medications are given to patients correctly to prevent the risk of side effects outcomes associated with the adverse drug-drug interaction. METHODS: A synthesized nanocomposite sorbent, dioctyl phthalate coated on the surface of magnetite (DOP@Fe3O4), was reinforced and immobilized into the pores of 2.5 cm segment hollow fiber microtube via ultrasonication, and the lumen of the microtube was filled with 1-octanol as an organic solvent with two ends heat-sealed. The prepared (DOP@Fe3O4-HF-SLPME) device was directly immersed into 10 mL of a sample solution containing atorvastatin and gemfibrozil with agitation. Subsequently, the microextraction device was transferred to HPLC-micro-vial containing an appropriate solvent, and the selected analytes were desorbed under ultrasonication prior to HPLCDAD analysis. The main factors influencing the adsorption and desorption process of the selected drugs have been optimized. RESULTS: The DOP@Fe3O4-HF-SLPME combined with the HPLC-DAD method was analytically evaluated for the simultaneous determination of atorvastatin and gemfibrozil in human urine samples using the optimized conditions. In spiked urine samples, the method showed a good linearity R2˃ 0.998, RSD from 1.41- 5.33%, and the limits of detection/ quantification (LOD/ LOQ) were 0.11/ 0.36 and 0.73/ 2.42 µg L-1 for atorvastatin and gemfibrozil, respectively. The enrichment factors of atorvastatin and gemfibrozil were 83.4 and 101.2, with extraction recoveries of 80.9% and 99.0%, respectively. The developed method demonstrated comparable results against referenced methods and a satisfactory result for determining the selected drugs in the patient's urine samples. CONCLUSION: The DOP@Fe3O4-HF-SLPME followed by HPLC-DAD was proved to be an efficient, sensitive, and cost-effective biopharmaceutical analysis method for trace levels of atorvastatin and gemfibrozil in the biological fluid matrix.


Assuntos
Dietilexilftalato , Microextração em Fase Líquida , Nanocompostos , Atorvastatina , Cromatografia Líquida de Alta Pressão , Genfibrozila , Humanos
2.
Biomed Chromatogr ; 33(2): e4410, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30315647

RESUMO

A new cetyl-alcohol-reinforced hollow fiber solid/liquid-phase microextraction (CA-HF-SLPME) followed by high-performance liquid chromatography-diode array detection (HPLC-DAD) method was developed for simultaneous determination of ezetimibe and simvastatin in human plasma and urine samples. To prepare the CA-HF-SLPME device, the cetyl-alcohol was immobilized into the pores of a 2.5 cm hollow fiber micro-tube and the lumen of the micro-tube was filled with 1-octanol with the two ends sealed. Afterwards, the prepared device was introduced into 10 mL of the sample solution containing the analytes with agitation. Under optimized conditions, calibration curves plotted in spiked plasma and urine samples were linear in the ranges of 0.363-25/0.49-25 µg L-1 for ezetimibe/simvastatin and 0.193-25/0.312-25 µg L-1 for ezetimibe/simvastatin in plasma and urine samples, respectively. The limit of detection was 0.109/0.174 µg L-1 for ezetimibe/simvastatin in plasma and 0.058/0.093 µg L-1 for ezetimibe/simvastatin in urine. As a potential application, the proposed method was applied to determine the concentration of selected analytes in patient plasma and urine samples after medication and satisfactory results were achieved. In comparison with reference methods, the CA-HF-SLPME-HPLC-DAD method demonstrates considerable potential in the biopharmaceutical analysis of selected drugs.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Ezetimiba/sangue , Ezetimiba/urina , Microextração em Fase Líquida/métodos , Sinvastatina/sangue , Sinvastatina/urina , Ezetimiba/isolamento & purificação , Álcoois Graxos , Feminino , Humanos , Limite de Detecção , Modelos Lineares , Masculino , Reprodutibilidade dos Testes , Sinvastatina/isolamento & purificação , Microextração em Fase Sólida/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...