Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Oral Health ; 24(1): 389, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532413

RESUMO

BACKGROUND: While the concept of angled screw channels has gained popularity, there remains a scarcity of research concerning the torque loss and fracture strength of monolithic zirconia restorations with various screw channel angulations when exposed to thermomechanical cycling. This in-vitro study aimed to evaluate the reverse torque value and fracture resistance of one-piece screw-retained hybrid monolithic zirconia restorations with angulated screw channels after thermomechanical cycling. METHODS: One-piece monolithic zirconia restorations, with angulated screw channels set at 0°, 15°, and 25° (n = 6 per angulation) were fabricated and bonded to titanium inserts using a dual-cure adhesive resin cement. These assemblies were then screwed to implant fixtures embedded in acrylic resin using an omnigrip screwdriver, and reverse torque values were recorded before and after thermomechanical cycles. Additionally, fracture modes were assessed subsequent to the application of compressive load. One-way ANOVA and Bonferroni post hoc test were used to compare the groups (α = 0.05). RESULTS: The study groups were significantly different regarding the fracture resistance (P = 0.0015), but only insignificantly different in the mean percentage torque loss (P = 0.4400). Specifically, the fracture resistance of the 15° group was insignificantly higher compared to the 0° group (P = 0.9037), but significantly higher compared to the 25° group (P = 0.0051). Furthermore, the fracture resistance of the 0° group was significantly higher than that of the 25° group (P = 0.0114). CONCLUSIONS: One-piece hybrid monolithic zirconia restorations with angulated screw channels can be considered an acceptable choice for angulated implants in esthetic areas, providing satisfactory fracture strength and torque loss.


Assuntos
Coroas , Cimentos Dentários , Zircônio , Humanos , Torque , Teste de Materiais , Dente Suporte , Titânio , Parafusos Ósseos , Análise do Estresse Dentário , Falha de Restauração Dentária
2.
J Med Life ; 16(5): 736-742, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37520485

RESUMO

This study aimed to examine the effect of inter-dental abutment distance on the accuracy of digital and conventional impression methods. Five maxillary and mandibular models were prepared with different inter-dental abutment distances. Digital scans were obtained using an extraoral laboratory scanner as reference data. Each group was scanned 8 times using the intra-oral scanner for the digital method. For the conventional impression method, 8 additional silicone impression material was used to generate the stone casts from each group. Then casts were scanned. In the next step, stereolithography (STL) data was exported from the scans. The STL files were super-imposed on the reference scans using 3shape dental designer software to make the measurement. Kolmogorov-Smirnoff was used to determine if the data were normally distributed. In the digital impression method, as the abutment distance increased, the accuracy decreased. Various inter-dental abutment distances in digital groups showed significant differences (p=0.016) in impression accuracy, while the difference among conventional groups was not statistically significant (p=0.822). In the digital method, the mean inter-dental abutment between the 4-5 and 3-7 groups, 4-6 and 3-7 groups had a significant difference (p<0.05). However, the conventional method revealed no significant differences (p>0.05) between groups. In conclusion, when the inter-dental abutment distance exists and is surrounded by soft tissue, the possibility of error in the digital impression method is higher than in the conventional impression method.


Assuntos
Dente Suporte , Modelos Dentários , Humanos , Desenho Assistido por Computador , Mandíbula , Maxila/diagnóstico por imagem , Imageamento Tridimensional , Técnica de Moldagem Odontológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...