Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Urology ; 77(1): 17-9, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21195820

RESUMO

OBJECTIVES: To test the effectiveness of the sterilization process of the transducer while applying the Food and Drug Administration recommendations on a routine basis in a high-volume clinical setup. In June 2006, the Food and Drug Administration issued a Public Health notification about reprocessing of the reusable ultrasound transducer assemblies used for transrectal biopsy of the prostate. METHODS: Transrectal ultrasound assembly components were systematically swabbed and cultured. The ultrasound gel and disinfectant fluid were also cultured. RESULTS: A total of 42 sets of cultures from 4 predetermined locations were obtained (n = 168). Bacterial growth was demonstrated in 2 sets of cultures, both from the transducer working channel (2 of 168, 1.19%): Streptococcus viridans from the distal orifice of the working channel and coagulase-negative staphylococcus from the proximal orifice. No bacterial growth was found in the gel samples or in the disinfectant fluid. No patient experienced a symptomatic urinary tract infection or sepsis, regardless of the culture results. CONCLUSIONS: Processing transrectal ultrasound biopsy transducer assemblies using the Food and Drug Administration recommendations achieved sterility in 98.8% of the cultures tested and in 95.2% of the consecutive cycles of equipment preparations.


Assuntos
Contaminação de Equipamentos , Próstata/patologia , Esterilização , Ultrassonografia de Intervenção/instrumentação , Biópsia por Agulha/métodos , Reutilização de Equipamento , Humanos , Masculino , Guias de Prática Clínica como Assunto , Próstata/diagnóstico por imagem , Estados Unidos , United States Food and Drug Administration
2.
Anaerobe ; 16(3): 201-5, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19781654

RESUMO

Conflicting data have accumulated in recent years regarding the incidence of anaerobic bacteraemias. The aim of this study was to determine the prevalence of bacteraemias due to anaerobic bacteria and evaluate the importance of anaerobic blood cultures in a university hospital in Israel. A retrospective survey which focused on anaerobic blood culture bottles was performed on blood cultures received in our laboratory during the decade from January 1998 to December 2007. Anaerobic-related bacteraemias decreased during that period, whereas a significant increase was observed in Bacteroides species isolated from the blood cultures (from 18% during 1998-2002 to 43% during 2003-2007). Comparison of the medical records of 54 patients with Bacteroides-related bacteraemia during the two end periods (1998-1999 and 2006-2007) revealed a marked increase in complex underlying diseases. Hypertension and diabetes mellitus type II were found in 29% of the patients in 1998-1999 and increased to 43-45% of the patients in 2006-2007. Ischemic heart disease also increased from 14% of the patients in 1998-1999 to 43% in 2006-2007. We conclude that although positive anaerobic blood cultures account for a small percentage of positive blood samples, the growing involvement of Bacteroides species-related bacteraemias together with an increase in complex underlying diseases in these patients emphasize the importance of anaerobic blood cultures, particularly in patients with co-morbidities.


Assuntos
Bacteriemia/epidemiologia , Bacteroides/classificação , Idoso , Bacteriemia/microbiologia , Bacteroides/isolamento & purificação , Comorbidade , Diabetes Mellitus Tipo 2/epidemiologia , Feminino , Hospitais Universitários , Humanos , Hipertensão/epidemiologia , Israel/epidemiologia , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/epidemiologia , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA