Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Orthod Sci ; 11: 7, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35754415

RESUMO

This systematic review was aimed to test the null hypothesis that coating of orthodontic wires with nanoparticles does not affect the frictional properties at bracket--wire interface. Electronic database searches were performed up to September 2020. In vitro studies were considered for reviewing process. Study selection, data extraction, risk of bias assessment was performed during reviewing process. Only qualitative analyses of included literature were done due to the presence of heterogeneity among the studies. Out of 1,068 retrieved records, nine studies satisfied the inclusion criteria and included in this review. Studies were assessed at low risk to high risk of bias according to certain parameters. Wide variety of nanoparticles were used for surface coating of orthodontic wires of variable sizes, shapes, and materials like stainless steel, NiTi, and TMA and placed into the slots of different types of orthodontic brackets to evaluate the alteration in frictional and other mechanical properties. Most of the studies clearly indicate that coating with nanoparticles decreases the friction between wire and bracket interface under specified in vitro conditions. Furthermore, among the nine included studies, only two considered evaluation of effect of coated brackets on frictional and other mechanical properties and results were heterogeneous. The null hypothesis is rejected and it is concluded that the wires coated with nanoparticles might offer a novel opportunity to substantially reduce frictional resistance at bracket--wire interface during tooth movement. Further studies are necessary to strengthen the evidence regarding effect of coated brackets on frictional properties.

3.
J Oral Biol Craniofac Res ; 11(2): 344-353, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33786298

RESUMO

OBJECTIVE: This systematic review was aimed to find out possible predictive variables measured on panoramic radiographs to predict spontaneous eruption of palatally displaced canine (PDC) after interceptive extraction in late mixed dentition. MATERIALS AND METHODS: Electronic database searches were performed in MEDLINE, Cochrane's CENTRAL, Scopus, and in other sources up to June 2020. Randomized and nonrandomized controlled trials, and pre-post prospective studies without control groups were considered for review. Study selection, data extraction, risk of bias assessment (by RoB 2.0, ROBINS-I, and NHLBI score), and the certainty of evidence evaluation (GRADE approach) were performed during reviewing process. Only qualitative analyses of included literature were done due to presence of between study heterogeneity. RESULTS: Out of 970 retrieved records, 3 controlled trials and 3 prospective before and after studies without control fulfilled the eligibility criteria and were included in the review. Studies were assessed at low risk to high risk of bias. Overall certainty was moderate to very low. Results shows that PDCs in distal sectors, lower alpha angle, younger subjects, PDCs with less advanced developed root were significantly benefited from interceptive extraction. However, Vertical distance had insignificant roll on eruption prediction. CONCLUSIONS: Interceptive extraction at younger age, mesial canine crown position (sectors), and mesial inclination of PDC (alpha angulation) are the most important variables predicting the spontaneous eruption of palatally displaced canine. Findings of this review can be utilized to make evidence-based decisions for managing PDCs with diverse sectors and mesial inclinations. However, well designed clinical trials are recommended to strengthen the evidence.

4.
Ann Pediatr Cardiol ; 13(1): 31-37, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32030033

RESUMO

BACKGROUND: The past two decades have seen rapid development of new surgical techniques for repair as well as palliation of complex congenital heart diseases. For a better patient outcome, minimal postoperative ventilation remains one of the most important endpoints of an effectual perioperative management. AIMS AND OBJECTIVES: The aim of this randomized open-label trial was to compare postoperative extubation time and intensive care unit (ICU) stay when two different anesthetic regimens, comprising of induction with ketamine and low-dose fentanyl versus high-dose fentanyl, are used, in pediatric patients undergoing corrective/palliative surgery. MATERIALS AND METHODS: Patients with congenital cardiac defects, under 14 years of age undergoing cardiac surgery under cardiopulmonary bypass (CPB) and epidural analgesia, were enrolled into two groups - Group K (ketamine with low-dose fentanyl) and Group F (high-dose fentanyl) - over a period of 10 months, starting from January 2018. The effect of both these drugs on postoperative extubation time and ICU stay was compared using Mann-Whitney U-test. RESULTS: A total of 70 patients were assessed with equal distribution in both the groups. In Group K, 32 of 35 patients were extubated in the operation room, whereas extubation time in Group F was18.1 ± 11 h. Total ICU stay in Group K and Group F was 45.2 ± 30.1 and 60.1 ± 24.5 h, respectively (P = 0.02). Systolic blood pressure was significantly higher in Group K. CONCLUSION: Ketamine along with low-dose fentanyl, when used for anesthetic induction, in comparison to high-dose fentanyl, reduces postoperative extubation time and ICU stay, in pediatric patients undergoing corrective/palliative surgery under CPB and epidural analgesia for congenital cardiac defects.

5.
Ann Thorac Surg ; 106(1): e27-e28, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29580780

RESUMO

Calcified amorphous tumors (CATs) of the heart are rare, nonneoplastic, intracavitary lesions, previously thought of as pseudotumors, hamartomas, or calcified thrombi, only reported in few adults in the available literature. This report describes a case of a pedunculated oscillating CAT arising from the left atrial appendage that prolapses through the mitral valve and causes severe mitral regurgitation in a newborn. This is the only case of cardiac CAT described in a neonate.


Assuntos
Calcinose/congênito , Cardiopatias Congênitas/complicações , Insuficiência da Valva Mitral/congênito , Apêndice Atrial/patologia , Apêndice Atrial/cirurgia , Biomarcadores , Calcinose/complicações , Calcinose/diagnóstico por imagem , Diagnóstico Diferencial , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/patologia , Neoplasias Cardíacas/diagnóstico , Humanos , Recém-Nascido , Masculino , Insuficiência da Valva Mitral/etiologia , Mixoma/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...