J Card Surg ; 20(3): 281-3, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15854096

RESUMO

Following percutaneous multivessel coronary stent implantation with full anticoagulation, a 65-year-old man suffered tamponade and cardiac arrest. After successful resuscitation, he underwent repeat coronary angiography which demonstrated extravasation of contrast from a distal circumflex subbranch. Thereafter, he was transferred to the cardiothoracic surgery unit where the leaking vessel was oversewn using the Medtronic Octopus Retractor for stabilization. This report illustrates the growing wider use of "off-pump" techniques beyond coronary artery bypass grafting. In this case, the patient was exposed to a much shorter procedure with less morbidity than could have been expected had cardiopulmonary bypass been used.


Assuntos
Angina Instável/terapia , Angioplastia Coronária com Balão/efeitos adversos , Anticoagulantes/efeitos adversos , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Vasos Coronários , Hemorragia/cirurgia , Idoso , Angina Instável/diagnóstico por imagem , Angioplastia Coronária com Balão/métodos , Anticoagulantes/uso terapêutico , Reanimação Cardiopulmonar/métodos , Angiografia Coronária , Ecocardiografia Doppler , Seguimentos , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Hemorragia/diagnóstico , Humanos , Masculino , Medição de Risco , Índice de Gravidade de Doença , Stents , Resultado do Tratamento