Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ir J Med Sci ; 189(3): 941, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32026269

RESUMO

In the original version of this article, the author list contained a number of errors, namely a missing author name, and author names that had been merged incorrectly.

2.
Ir J Med Sci ; 189(3): 895-905, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31981072

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) has been shown to reduce mortality and morbidity in symptomatic patients with reduced left ventricular systolic function < 35%, a left bundle branch block (LBBB) and a widened QRS complex. This paper compares Irish national CRT practices with the European data that was gathered in the same multi-centre CRT Survey II. METHODS: Each recruiting centre completed an internet-based facilitating collection of information relating to health care resource utilization by each centre. A second form was completed for consecutive patients undergoing CRT implantation, to provide information on patient demographics, pre-implantation clinical evaluation and investigations, indication for implantation and the procedure as well as short-term complications and adverse events. RESULTS: A total of 85 patients from 2 centres were representative of the current Irish practice and compared with data obtained. This was 26.6% of all CRT implantations in Ireland during this period (total number 319, 88 CRT-P, 231 CRT-D). Of those receiving CRT device, mean age was 73 years, 74.1% were male, with predominantly NYHA class III symptoms, and left ventricular ejection fraction < 35%. NT-pro-BNP level was substantially elevated in most patients. 56% were in sinus rhythm, 31% in atrial fibrillation with overall mean QRS duration of 166 ms. CONCLUSIONS: Within Ireland, the majority of CRT implantation are adherent with ESC guidelines. It has also highlighted problems that are noted in other ESC member countries such as the underutilization of device therapy in women, lack of referrals from peripheral centres and further need for optimization of medical therapy before device implantation.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/normas , Terapia de Ressincronização Cardíaca/métodos , Idoso , Europa (Continente) , Feminino , Humanos , Irlanda , Masculino , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...