Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38747243

RESUMO

STUDY DESIGN: Retrospective cohort study. OBJECTIVE: The purpose of this study was to investigate the rate of cervical total disc replacement (TDR) device removal or revision. SUMMARY OF BACKGROUND DATA: Cervical TDR has gained acceptance as an alternative to anterior cervical discectomy and fusion (ACDF) in appropriately selected patients. There have been concerns over device safety, one measure of which is subsequent surgery related to device problems. METHODS: A consecutive series of 1,626 cervical TDR patients from 2003 to June 2021 were included, consisting of TDRs up to 3 levels and hybrids (TDR and fusion). TDR removal or revision surgeries and reasons for these surgeries, procedures performed, and duration from index procedure were recorded. Data were analyzed to determine removal/revision rate and factors possibly related to these events. RESULTS: There were 24 removals/revisions (1.48%) in the 1,626 patients. Removal was performed in 23 cases (1.41%) and revision in 1 (0.06%). Among removal cases, ACDF was performed in 18 and TDR was replaced with another TDR in 5. Removals with fusion included 5 cases of osteolysis with/without C. acnes, 4 device displacement/migration, 4 posterior spinal pathology, and one for each of the following: metal allergy, approach-related complications, malpositioning, subsidence, and hypermobility. The revision involved TDR repositioning 3 days after index surgery. There were 66 patients for whom minimum of 10year follow-up was confirmed, and none had removal/revision surgery 10 or more years after index surgery. There was no relationship between occurrence of removal/revision and age, gender, body mass index, or physician experience (learning curve). The removal/revision rate was significantly higher in FDA trials vs. post-approval (4.1% vs. 1.3%, P<0.05). CONCLUSION: In this large consecutive series of patients, 1.48% of cervical TDRs were removed/revised. The low rate of removals/revisions over a long period of time provides support for the devices' safety.

2.
Spine (Phila Pa 1976) ; 49(10): 671-676, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38282440

RESUMO

STUDY DESIGN: This was a retrospective study with prospective patient contact attempted to collect current data. OBJECTIVE: The purpose was to investigate the incidence and reasons for lumbar total disk replacement (TDR) removal or revision. SUMMARY OF BACKGROUND DATA: A concern regarding lumbar TDR was safety, particularly the need for device removal or revision. This may be particularly important considering removal/revision requires repeat anterior exposure with an increased risk of vascular injury. METHODS: Data were collected for a series of 2141 lumbar TDR patients, beginning with the first case experience in 2000. The mean follow-up was 78.6 months. For each case of device removal/revision, the reason, duration from index surgery, and procedure performed were recorded. RESULTS: Of 2141 patients, 27 (1.26%) underwent TDR removal or revision. Device removal was performed in 24 patients (1.12%), while three patients underwent revision (0.14%). Of the 24 removals, 12 were due to migration and/or loosening, three developed problems post-trauma, two developed lymphocytic reaction to device materials, two had ongoing pain, and there was one case of each: TDR was too large, vertebral body fracture (osteoporosis), lytic lesion, device subsidence and facet arthrosis, and infection seeded from a chest infection 146 months post-TDR. The three revisions were for Core repositioning (technique error), device repositioning after displacement, and core replacement due to wear/failure. With respect to timing, 37.0% of removals/revisions occurred within one-month postimplantation. Of note, 40.7% of removals/revisions occurred in the first 25 TDR cases performed by individual surgeons. There was one significant vascular complication occurring in a patient whose TDR was removed due to trauma. This was also the only patient among 258 with ≥15-year follow-up who underwent removal/revision. CONCLUSION: In this large consecutive series, 1.26% of TDRs were removed/revised. The low rate over a 20 year period supports the safety of these devices.


Assuntos
Remoção de Dispositivo , Vértebras Lombares , Reoperação , Substituição Total de Disco , Humanos , Substituição Total de Disco/efeitos adversos , Substituição Total de Disco/instrumentação , Substituição Total de Disco/métodos , Masculino , Vértebras Lombares/cirurgia , Feminino , Reoperação/estatística & dados numéricos , Pessoa de Meia-Idade , Adulto , Estudos Retrospectivos , Idoso , Seguimentos , Resultado do Tratamento
4.
Int J Spine Surg ; 17(1): 1-5, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35940637

RESUMO

BACKGROUND: Anterior lumbar interbody fusion (ALIF) has been performed for many years. Often, posterior supplemental fixation has been used to provide additional stability to the operated segment. Interbody implants have evolved to incorporate unique designs, polyetheretherketone, integrated screws, and surface texture. With these changes, the need for supplemental posterior fixation has been debated. The purpose of this study was to evaluate the clinical outcome of stand-alone ALIF. METHODS: A surgery log was reviewed to identify the consecutive series of 58 patients undergoing ALIF using a STALIF stand-alone cage from March 2011 (first case) to December 2018 (minimum 24 months postoperative) with a mean follow-up of 30.6 months. All patients were treated for symptomatic degenerative conditions. Charts were reviewed to collect general patient information, operative data, and patient-reported outcomes, including the Oswestry Disability Index (ODI), visual analog scales (VAS) separately assessing back pain and leg pain, and re-operations. For patients who were not seen recently in clinic for follow-up, current outcome data were collected through mailings. RESULTS: The mean operative blood loss was 52.1 mL. There was a statistically significant improvement in mean ODI scores from 41.7 preoperatively to 21.0 at follow-up (P < 0.01). There was also significant improvement (P < 0.01) in VAS back pain (6.0-2.5) and leg pain (4.1-1.3). Subsequent surgery was performed on 9 patients. Reasons for re-operation were pseudoarthrosis (n = 3), progressive cage subsidence (n = 1), foraminal stenosis at the index level (n = 1), metal allergy reaction (n = 2), adjacent segment degeneration (n = 1), and ongoing pain (n = 1). There were no cases of device failure, vertebral body fracture, or screws backing out of the implant. DISCUSSION: Stand-alone ALIF was associated with statistically significant improvements in ODI scores, back pain, and leg pain. The re-operation rate for clear pseudoarthrosis or cage subsidence was 6.8%. These results support that stand-alone ALIF produces good outcomes in patients treated for symptomatic disc degeneration while avoiding the use of posterior fixation and its complication risk and cost. CLINICAL RELEVANCE: The results of this study support that stand-alone ALIF is a viable procedure for the treatment of symptomatic disc degeneration unresponsive in patients who have failed nonoperative care and who do not have specific indications for supplemental posterior instrumentation.

5.
Eur Spine J ; 31(10): 2607-2611, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35922636

RESUMO

PURPOSE: The purpose of this study was to investigate reasons and their frequency for why spine surgeons subspecializing in total disc replacement (TDR) performed lumbar fusion rather than TDR. METHODS: The study was based on a consecutive series of 515 patients undergoing lumbar TDR or fusion during a 5-year period by three surgeons specializing in TDR. For each fusion patient, the reason for not performing TDR was recorded. RESULTS: TDR was performed in 65.4% (n = 337) of patients and the remaining 34.6% (n = 178) underwent anterior lumbar interbody fusion (ALIF ± posterior instrumentation). Of the 178 fusion patients, the most common reason for fusion was combined factors related to severe degenerative changes (n = 59, 11.5% of the study population). The second most common reason was > Grade 1 spondylolisthesis (n = 32, 6.2%), followed by insurance non-coverage (n = 24, 4.7%), and osteopenia/osteoporosis (n = 13, 2.5%). Fusion patients were significantly older than TDR patients (52.5 vs. 41.6 years; p < 0.01). There was no significant difference with respect to gender (41.2% female vs. 43.8% female, p > 0.05) or the percentage of patients with single-level surgery (61.2% vs. 56.7%, p > 0.05). CONCLUSION: The most common reason for not performing lumbar TDR was related to anatomic factors that may compromise stability of the operated segment and/or TDR functionality. The older age of fusion patients may be related to these factors. This study found that many patients are appropriate candidates for lumbar TDR. However, even among TDR subspecialists, fusion is preferred when there are factors that cannot be addressed with TDR and/or may compromise implant functionality.


Assuntos
Degeneração do Disco Intervertebral , Fusão Vertebral , Cirurgiões , Substituição Total de Disco , Feminino , Humanos , Degeneração do Disco Intervertebral/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Masculino , Fusão Vertebral/métodos , Substituição Total de Disco/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...