1.
Rev Sci Instrum ; 89(9): 094708, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30278723

RESUMO

A new, previously unused combination of the high magnetic field side probing and the lower extraordinary mode cutoff was used in the T-10 tokamak for the electron density profile measurements by using a frequency modulation continuous wave reflectometer. This scheme has a significant advantage for large fusion machines where flat electron density profiles and high electron temperatures are expected. The reflectometer design is based on a common scheme with voltage controlled oscillators, active multipliers, and in-phase/quadrature signal detection. Iterative procedures were applied to calibrate a microwave source frequency and compensate the dispersion of probing signals in the conventional rectangular waveguides used as the transmission lines. About 0.2% stability of the beating frequency was reached after the calibration procedure had been finished. An advanced finite-difference scheme was proposed for the reconstruction of the electron density profile to reduce errors and improve the overall performance of the algorithm. Reconstructed electron density profiles demonstrate good agreement with conventional T-10 diagnostic data. Some specific technical and physical aspects of the diagnostic were also discussed on the basis of T-10 operation experience.

2.
Anesteziol Reanimatol ; 62(1): 32-35, 2017 Jan.
Artigo em Inglês, Russo | MEDLINE | ID: mdl-29932577

RESUMO

Realising for thefirst time in Russia the transportation of a patient with critical respiratory failure in conditions of EC-MO-therapy, the authors have accumulated great experience of its application at the stage of inter-hospital evacuation. This category ofpatients previously considered non-transportable by the severity of their condition. Having conducted a retrospective analysis of clinical experience in the use of high-tech medical care method, the authors received a zero mortality and questioned the possible new criteria and recommendations in assessing risk of death in patients with life-threatening conditions at the stage of inter-hospital transportation.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Insuficiência Respiratória/terapia , Transporte de Pacientes/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Federação Russa , Adulto Jovem
3.
Voen Med Zh ; 336(4): 10-5, 2015 Apr.
Artigo em Russo | MEDLINE | ID: mdl-26454933

RESUMO

This publication is the first case report, in the Russian Federation aircraft evacuation of a patient with severe respiratory failure due to pneumonia of viral and bacterial etiology with the use of extracorporeal membrane oxygenation. The use of this method helped to stabilize the patient's condition and safely carry out transportation to a specialized medical institution for further treatment.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Militares , Pneumonia Bacteriana/terapia , Pneumonia Viral/terapia , Insuficiência Respiratória/terapia , Transporte de Pacientes/métodos , Resgate Aéreo , Humanos , Masculino , Pneumonia Bacteriana/complicações , Pneumonia Viral/complicações , Insuficiência Respiratória/diagnóstico , Insuficiência Respiratória/etiologia , Resultado do Tratamento , Adulto Jovem
5.
Vestn Khir Im I I Grek ; 167(1): 69-71, 2008.
Artigo em Russo | MEDLINE | ID: mdl-18411673

RESUMO

The article presents data of an analysis of anesthesiologic maintenance of 3410 cesarean sections under conditions of spinal and epidural anesthesia. A detailed examination of 378 women has shown that frequency of the development of postinjection syndrome depends on the area of the defect of dura mater and the volume of lost cerebrospinal fluid. Postinjection syndrome can be prevented by using special needles leaving a less defect in dura mater and by introduction of 10-15 ml of sterile isotonic solution of sodium chloride into the epidural space.