Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cancers (Basel) ; 15(20)2023 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-37894469

RESUMO

PURPOSE: The study evaluates the efficacy of cone-beam computed tomography (CBCT)-based synthetic CTs (sCT) as a potential alternative to verification CT (vCT) for enhanced treatment monitoring and early adaptation in proton therapy. METHODS: Seven common treatment sites were studied. Two sets of sCT per case were generated: direct-deformed (DD) sCT and image-correction (IC) sCT. The image qualities and dosimetric impact of the sCT were compared to the same-day vCT. RESULTS: The sCT agreed with vCT in regions of homogeneous tissues such as the brain and breast; however, notable discrepancies were observed in the thorax and abdomen. The sCT outliers existed for DD sCT when there was an anatomy change and for IC sCT in low-density regions. The target coverage exhibited less than a 5% variance in most DD and IC sCT cases when compared to vCT. The Dmax of serial organ-at-risk (OAR) in sCT plans shows greater deviation from vCT than small-volume dose metrics (D0.1cc). The parallel OAR volumetric and mean doses remained consistent, with average deviations below 1.5%. CONCLUSION: The use of sCT enables precise treatment and prompt early adaptation for proton therapy. The quality assurance of sCT is mandatory in the early stage of clinical implementation.

2.
BMC Med Inform Decis Mak ; 23(1): 238, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37880712

RESUMO

BACKGROUND: Online questionnaires are commonly used to collect information from participants in epidemiological studies. This requires building questionnaires using machine-readable formats that can be delivered to study participants using web-based technologies such as progressive web applications. However, the paucity of open-source markup standards with support for complex logic make collaborative development of web-based questionnaire modules difficult. This often prevents interoperability and reusability of questionnaire modules across epidemiological studies. RESULTS: We developed an open-source markup language for presentation of questionnaire content and logic, Quest, within a real-time renderer that enables the user to test logic (e.g., skip patterns) and view the structure of data collection. We provide the Quest markup language, an in-browser markup rendering tool, questionnaire development tool and an example web application that embeds the renderer, developed for The Connect for Cancer Prevention Study. CONCLUSION: A markup language can specify both the content and logic of a questionnaire as plain text. Questionnaire markup, such as Quest, can become a standard format for storing questionnaires or sharing questionnaires across the web. Quest is a step towards generation of FAIR data in epidemiological studies by facilitating reusability of questionnaires and data interoperability using open-source tools.


Assuntos
Software , Humanos , Inquéritos e Questionários , Estudos Epidemiológicos
3.
Med Phys ; 50(7): 4623-4636, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36932693

RESUMO

BACKGROUND: The potential reduction of normal tissue toxicities during FLASH radiotherapy (FLASH-RT) has inspired many efforts to investigate its underlying mechanism and to translate it into the clinic. Such investigations require experimental platforms of FLASH-RT capabilities. PURPOSE: To commission and characterize a 250 MeV proton research beamline with a saturated nozzle monitor ionization chamber for proton FLASH-RT small animal experiments. METHODS: A 2D strip ionization chamber array (SICA) with high spatiotemporal resolution was used to measure spot dwell times under various beam currents and to quantify dose rates for various field sizes. An Advanced Markus chamber and a Faraday cup were irradiated with spot-scanned uniform fields and nozzle currents from 50 to 215 nA to investigate dose scaling relations. The SICA detector was set up upstream to establish a correlation between SICA signal and delivered dose at isocenter to serve as an in vivo dosimeter and monitor the delivered dose rate. Two off-the-shelf brass blocks were used as apertures to shape the dose laterally. Dose profiles in 2D were measured with an amorphous silicon detector array at a low current of 2 nA and validated with Gafchromic films EBT-XD at high currents of up to 215 nA. RESULTS: Spot dwell times become asymptotically constant as a function of the requested beam current at the nozzle of greater than 30 nA due to the saturation of monitor ionization chamber (MIC). With a saturated nozzle MIC, the delivered dose is always greater than the planned dose, but the desired dose can be achieved by scaling the MU of the field. The delivered doses exhibit excellent linearity with R 2 > 0.99 ${R^2} > 0.99$ with respect to MU, beam current, and the product of MU and beam current. If the total number of spots is less than 100 at a nozzle current of 215 nA, a field-averaged dose rate greater than 40 Gy/s can be achieved. The SICA-based in vivo dosimetry system achieved excellent estimates of the delivered dose with an average (maximum) deviation of 0.02 Gy (0.05 Gy) over a range of delivered doses from 3 to 44 Gy. Using brass aperture blocks reduced the 80%-20% penumbra by 64% from 7.55 to 2.75 mm. The 2D dose profiles measured by the Phoenix detector at 2 nA and the EBT-XD film at 215 nA showed great agreement, with a gamma passing rate of 95.99% using 1 mm/2% criterion. CONCLUSION: A 250 MeV proton research beamline was successfully commissioned and characterized. Challenges due to the saturated monitor ionization chamber were mitigated by scaling MU and using an in vivo dosimetry system. A simple aperture system was designed and validated to provide sharp dose fall-off for small animal experiments. This experience can serve as a foundation for other centers interested in implementing FLASH radiotherapy preclinical research, especially those equipped with a similar saturated MIC.


Assuntos
Terapia com Prótons , Prótons , Dosagem Radioterapêutica , Terapia com Prótons/métodos , Síncrotrons , Radiometria
4.
Sci Rep ; 8(1): 11549, 2018 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30068925

RESUMO

We have developed a proof of concept electrode design to covalently graft poly(methyl methacrylate) brushes directly to silicon thin film electrodes via surface-initiated atom transfer radical polymerization. This polymer layer acts as a stable artificial solid electrolyte interface that enables surface passivation despite large volume changes during cycling. Thin polymer layers (75 nm) improve average first cycle coulombic efficiency from 62.4% in bare silicon electrodes to 76.3%. Average first cycle reversible capacity was improved from 3157 to 3935 mAh g-1, and average irreversible capacity was reduced from 2011 to 1020 mAh g-1. Electrochemical impedance spectroscopy performed on silicon electrodes showed that resistance from solid electrolyte interface formation increased from 79 to 1508 Ω in untreated silicon thin films over 26 cycles, while resistance growth was lower - from 98 to 498 Ω - in silicon films functionalized with PMMA brushes. The lower increase suggests enhanced surface passivation and lower electrolyte degradation. This work provides a pathway to develop artificial solid electrolyte interfaces synthesized under controlled reaction conditions.

5.
ACS Appl Mater Interfaces ; 10(11): 9424-9434, 2018 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-29499109

RESUMO

We present a method to prepare shear thickening electrolytes consisting of silica nanoparticles in conventional liquid electrolytes with limited flocculation. These electrolytes rapidly and reversibly stiffen to solidlike behaviors in the presence of external shear or high impact, which is promising for improved lithium ion battery safety, especially in electric vehicles. However, in initial chemistries the silica nanoparticles aggregate and/or sediment in solution over time. Here, we demonstrate steric stabilization of silica colloids in conventional liquid electrolyte via surface-tethered PMMA brushes, synthesized via surface-initiated atom transfer radical polymerization. The PMMA increases the magnitude of the shear thickening response, compared to the uncoated particles, from 0.311 to 2.25 Pa s. Ultrasmall-angle neutron scattering revealed a reduction in aggregation of PMMA-coated silica nanoparticles compared to bare silica nanoparticles in solution under shear and at rest, suggesting good stabilization. Conductivity tests of shear thickening electrolytes (30 wt % solids in electrolyte) at rest were performed with interdigitated electrodes positioned near the meniscus of electrolytes over the course of 24 h to track supernatant formation. Conductivity of electrolytes with bare silica increased from 10.1 to 11.6 mS cm-1 over 24 h due to flocculation. In contrast, conductivity of electrolytes with PMMA-coated silica remained stable at 6.1 mS cm-1 over the same time period, suggesting good colloid stability.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...